Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAD-ACID BATTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An averaging battery model for a lead-acid battery operating in an electric car

A battery model is developed based on time averaging the current or power, and is shown to be an effective means of predicting the performance of a lead acid battery. The effectiveness of this battery model was tested on battery discharge profiles expected during the operation of an electric vehicle following the various SAE J227a driving schedules. The averaging model predicts the performance of a battery that is periodically charged (regenerated) if the regeneration energy is assumed to be converted to retrievable electrochemical energy on a one-to-one basis.

Bozek, J. M.↗

A new lead-acid battery for high pulse power applications

The development of new electronically conductive materials which can withstand the environment of the positive plates has made possible the construction of a high pulse power sealed bipolar lead-acid battery. The new battery is described and its advantages over other electrochemical systems are outlined. Performance projections show that the peak specific power of the battery can be as high as 90 kW/kg, and that a specific power of 5 kW/kg can be sustained over several thousand pulses.

Rowlette, J. J.↗

Response of lead-acid batteries to chopper-controlled discharge: Preliminary results

The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses up to 25 percent compared to constant current discharges at the same average discharge current of 100 amperes. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-ampere pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

Cataldo, R. L.↗

Response of lead-acid batteries to chopper-controlled discharge

The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses at up to 25 percent compared to constant current discharges at the same average discharge current of 100 A. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-A pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

Cataldo, R. L.↗

Response of lead-acid batteries to chopper-controlled discharge

The results of tests on an electric vehicle battery, using a simulated electric vehicle chopper-speed controller, show energy output losses up to 25 percent compared to constant current discharges at the same average current of 100 A. However, an energy output increase of 22 percent is noticed at the 200 A average level and 44 percent increase at the 300 A level using pulse discharging. Because of these complex results, electric vehicle battery/speed controller interactions must be considered in vehicle design.

Cataldo, R. L.↗

Energy Storage Cost and Performance Database

In support of the U.S. Department of Energy’s Energy Storage Grand Challenge, Pacific Northwest National Laboratory is applying its rich history of battery research and development to provide the U.S. Department of Energy (DOE) and industry with a guide to current energy storage costs and performance metrics for various technologies. Cost and performance metrics for individual technologies track the following to provide an overall cost of ownership for each technology: cost to procure, install, and connect an energy storage system; associated operational and maintenance costs; and end-of-life costs. These metrics are intended to support DOE and industry stakeholders in making sound decisions about future R&D directions and priorities that move the United States closer to its goal of energy independence. The technologies currently being evaluated are lithium-ion [lithium iron phosphate (LFP) and nickel manganese cobalt (NMC)] batteries, vanadium redox flow batteries, lead-acid batteries, zinc-based batteries, hydrogen energy storage, pumped storage hydropower, gravitational energy storage, compressed air energy storage, and thermal energy storage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary power train design for a state-of-the-art electric vehicle

The state-of-the-art (SOTA) of electric vehicles built since 1965 was reviewed to establish a base for the preliminary design of a power train for a SOTA electric vehicle. The performance of existing electric vehicles were evaluated to establish preliminary specifications for a power train design using state-of-the-art technology and commercially available components. Power train components were evaluated and selected using a computer simulation of the SAE J227a Schedule D driving cycle. Predicted range was determined for a number of motor and controller combinations in conjunction with the mechanical elements of power trains and a battery pack of sixteen lead-acid batteries - 471.7 kg at 0.093 MJ/Kg (1040 lbs. at 11.7 Whr/lb). On the basis of maximum range and overall system efficiency using the Schedule D cycle, an induction motor and 3 phase inverter/controller was selected as the optimum combination when used with a two-speed transaxle and steel belted radial tires. The predicted Schedule D range is 90.4 km (56.2 mi). Four near term improvements to the SOTA were identified, evaluated, and predicted to increase range approximately 7%.

Ross, J. A.↗

Batteries for storage of wind-generated energy

Cost effectiveness characteristics of conventional-, metal gas-, and high energy alkali metal-batteries for wind generated energy storage are considered. A lead-acid battery with a power density of 20 to 30 watt/hours per pound is good for about 1500 charge-discharge cycles at a cost of about $80 per kilowatt hour. A zinc-chlorine battery that stores chlorine as solid chlorine hydrate at temperatures below 10 C eliminates the need to handle gaseous chlorine; its raw material cost are low and inexpensive carbon can be used for the chlorine electrode. This system has the best chance to replace lead-acid. Exotic alkali metal batteries are deemed too costly at the present stage of development.

Schwartz, H. J.↗

Power Sources Symposium, 27th, Atlantic City, N.J., June 21-24, 1976, Proceedings

A lithium-chlorine rechargeable battery is considered along with an FeS electrode development for a secondary Li5Si-FeS battery, the sodium-sulfur battery, nickel battery systems for electric vehicles, reactions in lithium thionyl chloride cells, progress in the development of lithium inorganic batteries, a stable electrolyte for Li/SO2 reserve cells, and rechargeable lithium transition metal sulfide batteries. Attention is also given to thermal runaway tests on nickel-cadmium aircraft batteries, the development of nickel-zinc batteries for aircraft, an evaluation of sealed lead acid batteries for aircraft applications, the charging of sealed lead-acid batteries, hydrogen recombination in sealed nickel-cadmium cells, the characteristics of nickel-hydrogen flight cells, the lithium-iodine cell, low power methanol fuel cells, and a nuclear battery hybrid configuration study.

Source record↗

Lead-oxygen closed-loop battery system

Calculations show that battery can deliver up to 35 watt-hours per pound, conventional lead-acid batteries deliver 10 to 15 watt-hours per pound. Weight reduction is due to replacement of solid lead-peroxide electrodes with metal current-collector screen, catalyst, and Teflon membrane.

Britz, W. J.↗

Modeling the Nucleation and Growth of Lead Sulfate Particles on Lead Electrodes

Lead-acid batteries (LABs) play a pivotal role in the energy storage sector with applications spanning from starting-lighting-ignition batteries to grid energy storage. Passivation of lead negative electrodes by PbSO 4 particles is a fundamental mechanism limiting the performance of LAB. In this regard, an electrochemical model is developed that simulates the nucleation and growth (N&G) dynamics of PbSO 4 particles on a flat lead electrode, responsible for its passivation. The model considers the electrochemical reactions between lead electrode and sulfuric acid, N&G of PbSO 4 particles, passivation of the lead surface, and the ternary transport of PbSO 4 (aq), bisulfate, and protons in H 2 SO 4 electrolyte. The model is validated with a dataset of cyclic voltammetry (CV) responses collected at several scan rates and H 2 SO 4 concentrations. The model shows remarkable qualitative and quantitative agreement with the experimental data including CV peak features, discharge capacity, and particle size. The model was employed to explore key N&G quantities, such as supersaturation, nucleation rate, particle count, growth rate, particle size, and surface coverage, and to examine how their interactions influence electrode utilization. Parametric studies were also conducted to evaluate how scan rates and acid concentrations influence the previously mentioned N&G quantities and, subsequently, the utilization of the electrode.

25 ENERGY STORAGE↗

Research study on multi-KW-DC distribution system

A detailed definition of the HVDC test facility and the equipment required to implement the test program are provided. The basic elements of the test facility are illustrated, and consist of: the power source, conventional and digital supervision and control equipment, power distribution harness and simulated loads. The regulated dc power supplies provide steady-state power up to 36 KW at 120 VDC. Power for simulated line faults will be obtained from two banks of 90 ampere-hour lead-acid batteries. The relative merits of conventional and multiplexed power control will be demonstrated by the Supervision and Monitor Unit (SMU) and the Automatically Controlled Electrical Systems (ACES) hardware. The distribution harness is supported by a metal duct which is bonded to all component structures and functions as the system ground plane. The load banks contain passive resistance and reactance loads, solid state power controllers and active pulse width modulated loads. The HVDC test facility is designed to simulate a power distribution system for large aerospace vehicles.

Berkery, E. A.↗

Definition study for photovoltaic residential prototype system

A site evaluation was performed to assess the relative merits of different regions of the country in terms of the suitability for experimental photovoltaic powered residences. Eight sites were selected based on evaluation criteria which included population, photovoltaic systems performance and the cost of electrical energy. A parametric sensitivity analysis was performed for four selected site locations. Analytical models were developed for four different power system implementation approaches. Using the model which represents a direct (or float) charge system implementation the performance sensitivity to the following parameter variations is reported: (1) solar roof slope angle; (2) ratio of the number of series cells in the solar array to the number of series cells in the lead-acid battery; and (3) battery size. For a Cleveland site location, a system with no on site energy storage and with a maximum power tracking inverter which feeds back excess power to the utility was shown to have 19 percent greater net system output than the second place system. The experiment test plan is described. The load control and data acquisition system and the data display panel for the residence are discussed.

Shepard, N. F.↗

Baseline tests of the EPC Hummingbird electric passenger vehicle

The rear-mounted internal combustion engine in a four-passenger Volkswagen Thing was replaced with an electric motor made by modifying an aircraft generator and powered by 12 heavy-duty, lead-acid battery modules. Vehicle performance tests were conducted to measure vehicle maximum speed, range at constant speed, range over stop-and-go driving schedules, maximum acceleration, gradeability limit, road energy consumption, road power, indicated energy consumption, braking capability, battery charger efficiency, and battery characteristics. Test results are presented in tables and charts.

Slavik, R. J.↗

Results of baseline tests of the EVA Metro sedan, Citi-car, Jet Industries Electra-van, CDA town car, and Otis P-500 van

Five electric vehicles were tested at vehicle test tracks using the SAE. The tests provide range data at steady speeds and for several driving cycles. Most tests were conducted with lead-acid traction batteries. The Otis Van and the Copper Electric Town Car were also tested with lead-acid and nickel-zinc batteries. The tests showed a range increase of from 82 to 101 percent depending on vehicle, speed, and test cycle.

Stenger, F. J.↗

Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway

Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.

Lithium Ion Batteries↗

Electric Car

NASA's Lewis Research Center undertook research toward a practical, economical battery with higher energy density. Borrowing from space satellite battery technology, Lewis came up with a nickel-zinc battery that promises longer life and twice the range of the lead-acid counterpart. Lewis researchers fabricated a prototype battery and installed it in an Otis P-500 electric utility van, using only the battery space already available and allowing battery weight equal to that of the va's conventional lead-acid battery

Source record↗