Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAD 178”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nuclear Data Sheets for A = 178

The present revision of the nuclear structure properties for the nuclides belonging to the A = 178 mass chain contains many improvements and additions to the material presented in the previous evaluation (1994Br18, Nucl. Data Sheets 72, 221 (1994)). Besides updating many values, and including supplementary data for already known levels, transitions and level schemes, the most noteworthy modifications with respect to the prior evaluation are extensive additions to the level schemes of {sup 178}Yb, {sup 178}Hf, {sup 178}Ta, {sup 178}W. {sup 178}Ir, {sup 178}Pt and {sup 178}Hg, based on HI reaction works performed after the last cutoff date (July 1993), and to {sup 178}Hf due to new data from recent Coulomb excitation experiments. Light ion ({sup 3}He, {alpha}) beam experiments have added many data for {sup 178}Ta. Beta decay studies have also provided significant data for {sup 178}W and {sup 178}Pt. Lastly the first report of the identification of {sup 178}Tl and {sup 178}Pb is included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FFTSF: Revisiting Sub-Seasonal Streamflow Forecasting with Simple Feedforward Network

Accurate short-to-subseasonal streamflow forecasts are vital for water management, including flood preparedness, drought mitigation, hydropower scheduling, and ecosystem protection. However, extending a forecast beyond a few days remains challenging due to complexity of hydrological processes. While recent self-attention based transformer architectures such as iTransformer have gained traction in time-series forecasting, these models suffer from several critical limitations: (1) significant computational overhead that scales quadratically with sequence length, (2) vulnerability to overfitting on limited hydrological datasets, (3) degraded performance on long-horizon forecasts due to attention decay, and (4) excessive architectural complexity that hampers interpretability and operational deployment. In this study, we propose a simple Feedforward Time Series Forecasting (FFTSF) network that directly addresses these limitations through its lightweight architecture and long-range forecasting capabilities. We evaluate FFTSF across 178 USGS stream gauges spanning diverse climate regimes by forecasting lead times of 1-, 7-, 14-, and 30-days. Our results demonstrate that FFTSF achieves competitive performance at short lead times (NSE of 0.778 for 1-day forecasts) while substantially outperforming complex baselines at longer forecast period, achieving the highest NSE (0.271) at 30-day forecasts with greater robustness and stability. For 30-day forecasts, FFTSF achieves a 71% improvement over NLinear, 57% improvement over DLinear and 12% improvement over the computationally intensive iTransformer while requiring fewer computational resources. Our findings reveal that architectural complexity is not necessary for hydrological forecasting, demonstrating that well-designed simple models can outperform attention mechanisms for subseasonal streamflow forecasting. The computational efficiency and consistent long-range performance of FFTSF make it suitable for water management applications where reliable extended forecasts are essential.

Krishnan Kutty Ambika, Anukesh [ORNL] (ORCID:00000↗

Estimating the energy requirement for hydrogen production in proton exchange membrane electrolysis cells using rapid operando hydrogen crossover analysis

Hydrogen (H 2 ) crossover in proton exchange membrane water electrolyzers refers to the process by which hydrogen produced at the cathode traverses the membrane and mixes with the oxygen produced at the anode. This phenomenon reduces efficiency and may pose flammability hazards. In this work we present a method for quantifying the H 2 content of the anode exhaust gas using a gas chromatograph that is capable of sampling data every 2 min. Subsequent theory is presented to calculate the crossover flux, overall H 2 efficiency, and H 2 energy requirements. Results the effects of membrane thickness using Nafion TM N117 (178 um) and Nafion TM NR212 (51 um) membranes. Furthermore, it was found that thinner membranes lead to improved VI performance but exhibit higher crossover rates. Despite their increased crossover, leading to decreased hydrogen efficiency, the calculated required energy for NR212 membrane-electrode assemblies (MEAs) was significantly lower than that of N117 MEAs.

08 HYDROGEN↗

Asteroids seen by JWST-MIRI: Radiometric size, distance, and orbit constraints

Infrared measurements of asteroids are crucial for the determination of physical and thermal properties of individual objects, and for understanding the small-body populations in the solar system as a whole. However, standard radiometric methods can only be applied if the orbit of an object is known, hence its position at the time of the observation. With JWST-MIRI observations the situation will change and many unknown, often very small, solar system objects will be detected. Later orbit determinations are difficult due to the faintness of the objects and the lack of dedicated follow-up concepts. We present MIRI observations of the outer-belt asteroid (10920) 1998 BC1 and an unknown object, detected in all nine MIRI bands in close apparent proximity to (10920). We developed a new method called STM-ORBIT to interpret the multi-band measurements without knowing the object’s true location. The power of the new technique is that it determines the most-likely heliocentric and observer-centric distance and phase angle ranges, allowing us to make a radiometric size estimate. The application to the MIRI fluxes of (10920) was used to validate the method. It leads to a confirmation of the known radiometric size-albedo solution, and puts constraints on the asteroid’s location and orbit in agreement with its true orbit. To back up the validation of the method, we obtained additional ground-based light curve observations of (10920), combined with Gaia data, which indicate a very elongated object (a/b ≥ 1.5), with a spin-pole at (λ, β) ecl = (178°, +81°), with an estimated error of about 20°, and a rotation period of 4.861191 ± 0.000015 h. A thermophysical study of all available JWST-MIRI and WISE measurements leads to a size of 14.5–16.5 km (diameter of an equal-volume sphere), a geometric albedo pV between 0.05 and 0.10, and a thermal inertia in the range 9–35 (best value 15) J m -2 s -0.5 K -1 . For the newly discovered MIRI object, the STM-ORBIT method revealed a size of 100–230 m. The new asteroid must be on a low-inclination orbit (0.7° < i < 2.0°) and it was located in the inner main-belt region during JWST observations. A beaming parameter η larger than 1.0 would push the size even below 100 meters, a main-belt regime that has escaped IR detections so far. This kind of MIRI observations can therefore contribute to formation and evolution studies via classical size-frequency studies, which are currently limited to objects larger than about one kilometer in size. We estimate that MIRI frames with pointings close to the ecliptic and short integration times of only a few seconds will always include a few asteroids; most of them will be unknown objects.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray diffraction and equation of state of the C–S–H room-temperature superconductor

X-ray diffraction indicates that the structure of the recently discovered carbonaceous sulfur hydride (C–S–H) room-temperature superconductor is derived from previously established van der Waals compounds found in the H 2 S–H 2 and CH 4 –H 2 systems. Crystals of the superconducting phase were produced by a photochemical synthesis technique, leading to the superconducting critical temperature T c of 288 K at 267 GPa. X-ray diffraction patterns measured from 124 to 178 GPa, within the pressure range of the superconducting phase, are consistent with an orthorhombic structure derived from the Al 2 Cu-type determined for (H 2 S) 2 H 2 and (CH 4 ) 2 H 2 that differs from those predicted and observed for the S–H system at these pressures. The formation and stability of the C–S–H compound can be understood in terms of the close similarity in effective volumes of the H 2 S and CH 4 components, and denser carbon-bearing S–H phases may form at higher pressures. Furthermore, the results are crucial for understanding the very high superconducting T c found in the C–S–H system at megabar pressures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoporous separators for supercapacitor using activated carbon monolith electrode from oil palm empty fruit bunches

Activated porous carbon electrode prepared from fibres of oil palm empty fruit bunches was used for preparing the carbon based supercapacitor cells. The symmetrical supercapacitor cells were fabricated using carbon electrodes, stainless steel current collector, H{sub 2}SO{sub 4} electrolyte, and three types of nanoporous separators. Cells A, B and C were fabricated using polypropylene, eggshell membrane, and filter paper, respectively. Electrochemical characterizations data from Electrochemical Impedance Spectroscopy, Cyclic Voltammetry, and Galvanic Charge Discharge techniques showed that specific capacitance, specific power and specific energy for cell A were 122 F g{sup −1}, 177 W kg{sup −1}, 3.42 Wh kg{sup −1}, cell B; 125 F g{sup −1}, 179 W kg{sup −1}, and 3.64 Wh kg{sup −1}, and cell C; 180 F g{sup −1}, 178 W kg{sup −1}, 4.27 Wh kg{sup −1}. All the micrographs from Field Emission Scanning Electron Microscope showed that the different in nanoporous structure of the separators lead to a significant different in influencing the values of specific capacitance, power and energy of supercapacitors, which is associated with the mobility of ion into the pore network. These results indicated that the filter paper was superior than the eggshell membrane and polypropylene nanoporous separators. However, we found that in terms of acidic resistance, polypropylene was the best nanoporous separator for acidic medium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-P-15: Report On AAPM TG 178 Gamma Knife Dosimetry and Quality Assurance

Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers Conclusion: The full TG 178 report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics. Consultant to Elekta, Inc.

60 APPLIED LIFE SCIENCES↗

Direct conversion of CO 2 to meso/macro-porous frameworks of surface-microporous graphene for efficient asymmetrical supercapacitors

CO 2 conversion to useful materials is the most attractive approach to control its content in the atmosphere. An ideal electrode material for supercapacitors should possess suitable meso/macro-pores as electrolyte reservoirs and rich micro-pores as places for the adsorption of electrolyte ions. In this paper, we designed and synthesized such an ideal material, meso/macro-porous frameworks of surface-microporous graphene (MFSMG), from CO 2 via its one-step exothermic reaction with potassium. Furthermore, the MFSMG electrode exhibited a high gravimetric capacitance of 178 F g -1 at 0.2 A g -1 in 2 M KOH and retained 85% capacitance after increasing current density by 50 times. The combination of the MFSMG electrode and the activated carbon (AC) electrode constructed an asymmetrical AC//MFSMG capacitor, leading to a high capacitance of 242.4 F g -1 for MFSMG and 97.4 F g -1 for AC. With the extended potential, the asymmetrical capacitor achieved an improved energy density of 9.43 W h kg -1 and a power density of 3504 W kg -1 . Finally, this work provides a novel solution to solve the CO 2 issue and creates an efficient electrode material for supercapacitors.

36 MATERIALS SCIENCE↗

Avalanche boron fusion by laser picosecond block ignition with magnetic trapping for clean and economic reactor

Measured highly elevated gains of proton–boron (HB11) fusion (Picciotto et al. , Phys. Rev. X 4 , 031030 (2014)) confirmed the exceptional avalanche reaction process (Lalousis et al. , Laser Part. Beams 32 , 409 (2014); Hora et al. , Laser Part. Beams 33 , 607 (2015)) for the combination of the non-thermal block ignition using ultrahigh intensity laser pulses of picoseconds duration. The ultrahigh acceleration above $10^{20}~\text{cm}~\text{s}^{-2}$ for plasma blocks was theoretically and numerically predicted since 1978 (Hora, Physics of Laser Driven Plasmas (Wiley, 1981), pp. 178 and 179) and measured (Sauerbrey, Phys. Plasmas 3 , 4712 (1996)) in exact agreement (Hora et al. , Phys. Plasmas 14 , 072701 (2007)) when the dominating force was overcoming thermal processes. This is based on Maxwell’s stress tensor by the dielectric properties of plasma leading to the nonlinear (ponderomotive) force $f_{\text{NL}}$ resulting in ultra-fast expanding plasma blocks by a dielectric explosion. Combining this with measured ultrahigh magnetic fields and the avalanche process opens an option for an environmentally absolute clean and economic boron fusion power reactor. Finally, this is supported also by other experiments with very high HB11 reactions under different conditions (Labaune et al. , Nature Commun. 4 , 2506 (2013)).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recommended Nuclear Data for the Production of Selected Therapeutic Radionuclides

Increasing interest in the treatment of human disease by means of targeted radionuclide-based therapies requires an accurate understanding of achievable yields and quantification of realisable degrees of purity. Important studies within a more extensive Coordinated Research Project of the International Atomic Energy Agency (IAEA CRP) have included in-depth assessments and evaluations of all available measured cross-section data for ten nuclear reactions leading to the formation of 131 Cs, 131 Ba, 225 Ac, 225 Ra, 227 Th, 227 Ac, 230 U and 230 Pa for various on-going and proposed therapeutic applications in nuclear medicine. Equivalent studies were also undertaken of possible reactions to produce the 178W /low-spin 178m Ta generator system that has been clinically applied in diagnosis by means of SPECT - these particular cross-section studies and recommendations are included in this paper for completeness. All available measured data have been critically reviewed and assessed to produce statistically consistent datasets. Selected datasets have been fitted by a least-squares method with Padé approximations of variable order to evaluate the production cross sections and corresponding uncertainties. New measurements have been made in some instances, and reported data have been adjusted to accommodate new nuclear decay or monitor reaction data which altered the original reported quantities adversely. Insufficient measured data are available in many cases to permit a reliable evaluation of cross sections, and these instances are discussed. Finally, recommended therapeutic radionuclide production reaction data and their uncertainties are available on the Web page of the IAEA Nuclear Data Section at www-nds.iaea.org/radionuclides/ and also at the IAEA medical portal www-nds.iaea.org/medportal/.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Fundamental Insight into Zr Modification of Li- and Mn-Rich Cathodes: Combined Transmission Eelctron Microscopy and Electrochemical Impedance Spectroscopy Study

Zr surface modification was performed on Li- and Mn-rich (LMR) cathode material (Li1.2Ni0.13Co0.13Mn0.54O2) to suppress the detrimental phase transformation upon cycling and enhance its electrochemical performance. Using a wet chemical method, a Zr-based rock-salt layer with a thickness of 1~2 nm was formed on the surface of the LMR. Controlled studies reveal that the Zr-based layers can effectively suppress the phase transformation, leading to an enhanced long-term cycling performance and rate capability. At C/3, the Zr-modified LMR material was found to deliver an initial discharge specific capacity of 211 mAh g-1, and maintain a capacity of 182 mAh g-1 after 100 cycles. Even at high rates of 1, 2 and 3C, it still displays high discharge capacities of 178, 156 and 143 mAh g-1, respectively. This work reports for the first time the detailed mechanisms at atomic scale of how Zr modification can be effectively used to tailor the surface microstructures of high energy cathode materials to improve their long-term stability and cycle life.

Li- and Mn-rich cathode, Li1.2Ni0.13Co0.13Mn0.54O2↗

TH-A-BRC-00: New Task Groups for External Beam QA: An Overview

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

TH-A-BRC-03: AAPM TG218: Measurement Methods and Tolerance Levels for Patient-Specific IMRT Verification QA

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗

Carbon Nanotube Supported Amorphous MoS 2 via Microwave Heating Synthesis for Enhanced Performance of Hydrogen Evolution Reaction

Amorphous molybdenum disulfide (MoS 2 ) is a promising electrochemical catalyst for hydrogen evolution reaction (HER) due to more active sites exposed on the surface compared to its crystalline counterpart. In this study, a novel fast three-minute one-pot method is proposed to prepare the single-wall carbon nanotube- (SWCNT-) supported amorphous MoS 2 via a microwave heating process. Compared to traditional hydro- or solvent thermal methods to prepare MoS 2 which usually consume more than 10 hours, it is more promising for fast production. An overpotential at 10 mA/cm 2 of amorphous MoS 2 @SWCNT is 178 mV, which is 99 mV and 22 mV lower than crystalline MoS 2 @SWCNT and pure amorphous MoS 2 , respectively. After running 1000 cycles of polarization, ~2% increase in overpotential is observed, indicating its good stability. The enhanced performance results from the beneficial combination of the SWCNT substrate and the amorphous microstructures. The introduction of SWCNT increases catalyst conductivity and prevents MoS 2 aggregation. The amorphous microstructures of MoS 2 prepared by a microwave heating method lead to more Mo edges or active sites exposed.

Tang, Wei↗

Structurally colored protease responsive nanoparticle hydrogels with degradation-directed assembly

A tunable protease responsive nanoparticle hydrogel (PRNH) that demonstrates large non-iridescent color changes due to a degradation-directed assembly of nanoparticles is reported. Structurally colored composites are fabricated with silica particles, 4-arm poly(ethylene glycol) norbornene (4PEGN), and a proteolytically degradable peptide. When placed in a protease solution, the peptide crosslinks degrade causing electrostatic binding and adsorption of the polymer to the particle surface which leads to the assembly of particles into compact amorphous arrays with structural color. The particle surface charge and size is investigated to probe their effect on the assembly mechanism. Interestingly, only PRNHs with highly negative particle surface charge exhibit color changes after degradation. Ultra-small angle X-ray scattering revealed that the particles become coated in polymer after degradation, producing a material with less order compared to the initial state. Altering the particle diameter modulates the composites’ color, and all sizes investigated (178–297 nm) undergo the degradation-directed assembly. Varying the amount of 4PEGN adjusts the swollen PRNH color and has no effect on the degradation-directed assembly. Finally, taken together, the effects of surface charge, particle size, and polymer concentration allow for the formulation of new design rules for fabricating tunable PRNHs that display vivid changes in structural color upon degradation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗