Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LANTHANUM BROMIDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Lanthanum Bromide Detectors for Safeguards Measurements

Lanthanum bromide has advantages over other popular inorganic scintillator detectors. Lanthanum bromide offers superior resolution, and good efficiency when compared to sodium iodide and lanthanum chloride. It is a good alternative to high purity germanium detectors for some safeguards applications. This paper offers an initial look at lanthanum bromide detectors. Resolution of lanthanum bromide will be compared lanthanum chloride and sodium-iodide detectors through check source measurements. Relative efficiency and angular dependence will be looked at. Nuclear material spectra, to include plutonium and highly enriched uranium, will be compared between detector types.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ba 11 La 4 Br 34 : a new barium lanthanum bromide

The structure of the title compound, barium lanthanum bromide (11/4/34), can be derived from the fluorite structure. The asymmetric unit contains two Ba sites (one with site symmetry 4/m..), one La site (site symmetry 4..), one mixed occupied Ba and La site (ratio 1:1, site symmetry m..) and six Br sites (one with site symmetry \=4.., one with 2.., one with m.., the latter being disordered over two positions with a 0.86:0.14 ratio). The fundamental building units of the structure are edge-sharing polyhedral clusters made up of Ba and La bromide clusters interconnected to BaBr8 square prisms and BaBr10 groups.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3 ) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235 U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lanthanum Bromide Detector System for Mu2e Stopping Target Monitor

The stopping target monitor (STM) in the Mu2e experiment is used to normalize the muon decay branching ratio in the Mu2e experiment, by estimating the number of muons that have been captured on the Mu2e nuclear target. The STM measures the distinctive muonic atomic transition lines and muonic nuclear excitations produced in the Aluminum Stopping Target of Mu2e. These signals must be disentangled in the presence of high rate Bremsstrahlung and other backgrounds produced in the target. An HPGe detector with fine energy resolution, ~0.1% will be employed but has limited count rate capability, ~20kcps. Time-to-Decision, that is the time to make an estimate of the experiments observed luminosity, is inversely proportional to the signal rate squared. For this reason the STM will also use a Lanthanum Bromide(LaBr3) detector, having ~2% energy resolution but capable of ~1 Mcps counting rate. This higher rate will allow not only an orthogonal verification of the HPGe luminosity measurements, but will also yield much finer luminosity measurements as a function of time because of its significantly higher counting rate capabilities. Geant4 simulations are presented comparing the performance of different sized, LaBr3 crystals. The results highly favor the use of the commercially available right circular cylindrical, 3x3-in. detector. Modifications to the STM design are discussed in order to take full advantage of the LaBr3 high rate and fast decision making capabilities. A preliminary design will be presented for a custom read-out system needed to fulfill these requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of a Lanthanum Bromide Detector and a New Conception Collimator for Radiopharmaceuticals Molecular Imaging in Oncology

We have realized and tested a new-design compact gamma camera for high resolution SPET (Single Photon Emission Tomography), and small animals' radio-pharmaceutical molecular imaging. The camera is based on a 'continuous' Lanthanum tri-Bromide crystal, and a new Low Energy (LE) collimator. The crystal is interfaced to a 2x2 array of Hamamatsu-H8500 position sensitive photo-multipliers. The lead collimator features parallel hexagonal 1.0 mm holes, 18 mm length, 0.2 mm septa and 10x10 cm{sup 2} detection area. It was newly designed to fully exploit the high spatial resolution a Lanthanum crystal may provide. To better evaluate its role, we have compared our camera to three other systems with similar crystals and photomultipliers, but employing traditional collimators, either pinhole or parallel. The new camera seems to be complementary to pinhole systems and shows a very attractive trade-off between spatial resolution and detection area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillators with potential to supersede lanthanum bromide

New scintillators for high-resolution gamma ray spectroscopy have been identified, grown and characterized. Our development efforts have focused on two classes of high light yield materials: Europium-doped alkaline earth halides and Cerium-doped garnets. Of the halide single crystals we have grown by the Bridgman method - SrI{sub 2}, CaI{sub 2}, SrBr{sub 2}, BaI{sub 2} and BaBr{sub 2} - SrI{sub 2} is the most promising. SrI{sub 2}(Eu) emits into the Eu{sup 2+} band, centered at 435 nm, with a decay time of 1.2 {micro}s and a light yield of up to 115,000 photons/MeV. It offers energy resolution better than 3% FWHM at 662 keV, and exhibits excellent light yield proportionality. Transparent ceramics fabrication allows production of Gadolinium- and Terbium-based garnets which are not growable by melt techniques due to phase instabilities. While scintillation light yields of Cerium-doped ceramic garnets are high, light yield non-proportionality and slow decay components appear to limit their prospects for high energy resolution. We are developing an understanding of the mechanisms underlying energy dependent scintillation light yield non-proportionality and how it affects energy resolution. We have also identified aspects of optical design that can be optimized to enhance energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation into Nanostructured Lanthanum Halides and CeBr{sub 3} for Nuclear Radiation Detection

This slide-show presents work on radiation detection with nanostructured lanthanum halides and CeBr{sub 3}. The goal is to extend the gamma energy response on both low and high-energy regimes by demonstrating the ability to detect low-energy x-rays and relatively high-energy activation prompt gamma rays simultaneously using the nano-structured lanthanum bromide, lanthanum fluoride, cerium bromide, or other nanocrystal material. Homogeneous and nano structure cases are compared.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nanostructured LaF{sub 3}:Ce Quantum Dot Nuclear Radiation Detector

Many radioactive isotopes have low energy X-rays and high energy gamma rays of interest for detection. The goal of the work presented was to demonstrate the possibility of measuring both low-energy X-rays and relatively high-energy gamma rays simultaneously using the nano-structured lanthanum bromide, lanthanum fluoride, or cerium bromide. The key accomplishments of the project was the building and acquisition of the LaF3:Ce nanocomposite detectors. Nanocomposite detectors are sensitive to {gamma}’s as well as n’s and X-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational Removal of Lanthanum-Cerium Bromide Self-Activity

It has been reported that detectors made of lanthanum–cerium halides, such as LaBr3(Ce) and CeBr3 have superior energy resolution for gamma-radiation detection compared to that offered by conventional sodium iodide [NaI(T1)] detectors. However, it has also been observed that the lanthanum–cerium halides contain certain amount of self-activity caused by the radioactive isotope 138La. Additionally, LaBr3(Ce) and CeBr3 crystals have also been reported to be affected by β-contamination in the low-energy and α-contamination in the high-energy regions. This paper presents a computational approach to reduce self-activity and contamination for LaBr3(Ce) and CeBr3 detectors using a third reference NaI(T1) detector. This procedure can be implemented as an automatic self-calibration module for gamma-radiation detectors made of LaBr3(Ce) and/or CeBr3 crystals.

Lanthanum bromide, Cerium bromide, Linear separati↗

Preliminary Investigation of Lanthanum-Cerium Bromide Self-Activity Removal

It has been reported that detectors made of lanthanum-cerium halides (LaBr3:Ce and CeBr3) have superior energy resolution for gamma-radiation detection compared to what is offered by conventional sodium iodide (NaI:T1) detectors1–6. Although superior energy resolution may be observed, one major barrier that has hindered the rapid adaptation of lanthanum halides is their self-activity, due primarily to the presence of isotope 138La, and the α contamination, due to the trace amount of actinides6–8. It has also been observed that the lanthanum-cerium halides contain a substantial amount of self-activity caused by the radioactive isotope 138La. Additionally, LaBr3:Ce spectra are also affected by β contaminations in the low-energy region. To use either LaBr3:Ce or CeBr3 for high-sensitivity gamma detection, it may be necessary to have the self-activity as well as α and β contaminations removed or reduced. This paper describes a novel algorithmic approach for self-activity and contamination reduction for LaBr3:Ce and CeBr3 detectors using a third reference NaI:T1 detector. We present a computational procedure for separating self-activity from the gamma spectra obtained by LaBr3:Ce detectors. With the self-activity spectra precalculated, it is possible to perform real-time self-activity removal. This procedure can be implemented as an automatic self-activity subtraction module for gamma-radiation detectors made of LaBr3:Ce and/or CeBr3 crystals. With this approach, it is possible to develop a new generation of LaBr3:Ce detectors capable of producing spectra as clean as those obtained by conventional NaI:T1 detectors, but with much improved energy resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear structure analysis using the Orange Spectrometer

Recently, an Orange spectrometer, a focusing iron-free magnetic spectrometer, has been installed at a beam line of the 10 MV Tandem accelerator of the IKP of the University of Cologne. The high efficiency of 15% of 4{pi} for the detection of conversion electrons and the energy resolution of 1% makes the Orange spectrometer a powerful instrument. From the conversion electron spectrum, transition multipolarities can be determined using the so called K to L ratio. In combination with an array of germanium and lanthanum bromide detectors, e{sup -}-{gamma}-coincidences can be performed to investigate the level scheme. Moreover, the very fast lanthanum bromide scintillator with an energy resolution of 3% allows e{sup -}-{gamma} lifetime measurements down to 0.3 ns. A second Orange spectrometer can be added to build the Double Orange Spectrometer for e{sup -}-e{sup -}-coincidences. It is indispensable for lifetime measurements of low intensity or nearby lying transitions as often occur in odd-A and odd-odd nuclei. The capabilities are illustrated with several examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A comparative study of LaBr{sub 3}(Ce{sup 3+}) and CeBr{sub 3} based gamma-ray spectrometers for planetary remote sensing applications

The recent availability of large volume cerium bromide crystals raises the possibility of substantially improving gamma-ray spectrometer limiting flux sensitivities over current systems based on the lanthanum tri-halides, e.g., lanthanum bromide and lanthanum chloride, especially for remote sensing, low-level counting applications or any type of measurement characterized by poor signal to noise ratios. The Russian Space Research Institute has developed and manufactured a highly sensitive gamma-ray spectrometer for remote sensing observations of the planet Mercury from the Mercury Polar Orbiter (MPO), which forms part of ESA’s BepiColombo mission. The Flight Model (FM) gamma-ray spectrometer is based on a 3-in. single crystal of LaBr{sub 3}(Ce{sup 3+}) produced in a separate crystal development programme specifically for this mission. During the spectrometers development, manufacturing, and qualification phases, large crystals of CeBr{sub 3} became available in a subsequent phase of the same crystal development programme. Consequently, the Flight Spare Model (FSM) gamma-ray spectrometer was retrofitted with a 3-in. CeBr{sub 3} crystal and qualified for space. Except for the crystals, the two systems are essentially identical. In this paper, we report on a comparative assessment of the two systems, in terms of their respective spectral properties, as well as their suitability for use in planetary mission with respect to radiation tolerance and their propensity for activation. We also contrast their performance with a Ge detector representative of that flown on MESSENGER and show that: (a) both LaBr{sub 3}(Ce{sup 3+}) and CeBr{sub 3} provide superior detection systems over HPGe in the context of minimally resourced spacecraft and (b) CeBr{sub 3} is a more attractive system than LaBr{sub 3}(Ce{sup 3+}) in terms of sensitivities at lower gamma fluxes. Based on the tests, the FM has now been replaced by the FSM on the BepiColombo spacecraft. Thus, CeBr{sub 3} now forms the central gamma-ray detection element on the MPO spacecraft.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanostructured Lanthanum Halides and CeBr3 for Nuclear Radiation and Detection

Scintillator materials are used to detect, and in some cases identify, gamma rays. Higher performance scintillators are expensive, hard to manufacture, fragile, and sometimes require liquid nitrogen or cooling engines. But whereas lower-quality scintillators are cheap, easy to manufacture, and more rugged, their performance is lower. At issue: can the desirable qualities of high-and low-performance scintillators be combined to achieve better performance at lower cost? Preliminary experiments show that a LaF{sub 3}:Ce oleic acid-based nanocomposite exhibits a photopeak when exposed to {sup 137}Cs source gamma-radiation. The chemical synthesis of the cerium-doped lanthanum halide nanoparticles are scalable and large quantities of material can be produced at a time, unlike typical crystal growth processes such as the Bridgeman process. Using a polymer composite (Figure 1), produced by LANL, initial measurements of the unloaded and 8% LaF{sub 3}:Ce-loaded sample have been made using {sup 137}Cs sources. Figure 2 shows an energy spectrum acquired for CeF{sub 3}. The lighter plot is the measured polymer-only spectrum and the black plot is the spectrum from the nanocomposite scintillator. As the development of this material continues, the energy resolution is expected to improve and the photopeak-to-Compton ratio will become greater at higher loadings. These measurements show the expected Compton edge in the polymer-only sample, and the Compton edge and photo-peak expected in the nanophosphor composites that LANL has produced. Using a porous VYCORR with CdSe/ZnS core shell quantum dots, Letant has demonstrated that he has obtained signatures of the 241Am photopeak with energy resolution as good at NaI (Figure 3). We begin with the fact that CeBr{sub 3} crystals do not have a self-activity component as strong as the lanthanum halides. The radioactive 0.090% {sup 138}La component of lanthanum leads to significant self-activity, which will be a problem for very large detector volumes. Yet a significant strength of the nanostructure detector concept is the ability to create extremely large detector volumes by mixing nanoparticles into a transparent matrix. This would argue for use of nanoparticles other than lanthanum halides. Nanocomposites are easy to prepare; it is much less costly to use nanocomposites than to grow large whole crystals of these materials. The material can be fabricated at an industrial scale, further reducing cost. This material potentially offers the performance of $300/cc material (e.g., lanthanum bromide) at a cost of $1/cc. Because the material acts as a plastic, it is rugged and flexible, and can be made in large sheets, increasing the sensitivity of a detector using it. It would operate at ambient temperatures. Very large volumes of detector may be produced at greatly reduced cost, enhancing the non-proliferation posture of the nation for the same dollar value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isomer spectroscopy of neutron-rich 168 Tb 103

In-flight fission of a 345 MeV per nucleon 238U primary beam on a 2 mm thick 9Be target has been used to produce and study the decays of a range of neutron-rich nuclei centred around the doubly mid-shell nucleus 170Dy at the RIBF Facility, RIKEN, Japan. The produced secondary fragments of interest were identified event-by-event using the BigRIPS separator. The fragments were implanted into the WAS3ABI position sensitive silicon active stopper which allowed pixelated correlations between implants and their subsequent β-decay. Discrete γ-ray transitions emitted following decays from either metastable states or excited states populated following beta decay were identified using the 84 coaxial high-purity germanium (HPGe) detectors of the EURICA spectrometer, which was complemented by 18 additional cerium-doped lanthanum bromide (LaBr3) fast-timing scintillation detectors from the FATIMA collaboration. This paper presents the internal decay of a metastable isomeric excited state in the odd-odd nucleus 168Tb, which corresponds to a single proton-neutron hole configuration in the valence maximum nucleus 170Dy. These data represent the first information on excited states in this nucleus, which is the most neutron-rich odd-odd isotope of terbium (Z=65) studied to date. Nilsson configurations associated with an axially symmetric, prolate-deformed nucleus are proposed for the 168Tb ground state the observed isomeric state by comparison with Blocked BCS-Nilsson calculations.

Gamma-ray spectroscopy and nuclear isomerism↗

Comparison of CeBr3 with LaBr3:Ce, LaCl3:Ce, and NaI:Tl Detectors

Energy resolution and detection efficiency were compared between two sizes of cerium bromide (CeBr3) scintillators, three sizes of lanthanum bromide (LaBr3:Ce) scintillators, three sizes of sodium iodide (NaI:Tl) scintillators, and a lanthanum chloride (LaCl3:Ce) scintillator. Comparisons are made of key parameters such as energy resolution, detection efficiency, linearity, and self-activity of CeBr3, LaBr3:Ce, LaCl3:Ce, and NaI:Tl scintillator detectors. The scintillator detectors are tested by comparing the peak separation and identification in the energy range up to 3.0 MeV using 133Ba, 152Eu, and naturally occurring radioactive materials [1]. The study has shown that CeBr3 scintillator detectors provided by Saint-Gobain offer better resolution than NaI:Tl scintillator detectors. CeBr3 detectors could resolve some closely spaced peaks from 133Ba and 152Eu, which NaI:Tl could not. LaBr3:Ce has slightly better resolution, and a slightly higher efficiency than CeBr3. In this work, “self-activity” of each of these four detector types was measured by operating the detectors themselves. A comparison of the intrinsic activity for all of the detectors in this study is demonstrated. For CeBr3, the self-activity present may be reduced, or even eliminated in the future, through improved processes for growing the material. It will be discussed if, and under what conditions, CeBr3 may be better than LaBr3:Ce and LaCl3:Ce for detection of certain special nuclear material γ-rays [2]. An overall advantage of CeBr3 detectors over lanthanum halide and NaI:Tl detectors will be discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗