Engineering PapersSearch

SEARCH · Engineering Papers

Results for “LABORATORY APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Airborne Laboratory Apparatus Draws Glass Fibers

Glass-fiber-drawing apparatus designed for studies of effect of gravitation on drawing process. Clear plastic housing surrounds fiber-drawing equipment and some of associated electronic instrumentation. External rack holds video monitor, personal computer, keyboard, videotape recorder, and power switch panel. Mounted in research aircraft, apparatus makes continuous video recordings of formation of fiber at effective gravitational accelerations ranging from 0.001 to 2 times normal Earth gravitational acceleration as aircraft dives, then pulls out of dives. Also records pertinent process data on video image.

Tucker, Dennis S.

Laboratory Apparatus Generates Dual-Species Cold Atomic Beam

A laser cooling apparatus that generates a cold beam of rubidium and cesium atoms at low pressure has been constructed as one of several intermediate products of a continuing program of research on laser cooling and atomic physics. Laser-cooled atomic beams, which can have temperatures as low as a microkelvin, have been used in diverse applications that include measurements of fundamental constants, atomic clocks that realize the international standard unit of time, atom-wave interferometers, and experiments on Bose-Einstein condensation. The present apparatus is a prototype of one being evaluated for use in a proposed microgravitational experiment called the Quantum Interferometric Test of Equivalence (QuITE). In this experiment, interferometric measurements of cesium and rubidium atoms in free fall would be part of a test of Einstein s equivalence principle. The present apparatus and its anticipated successors may also be useful in other experiments, in both microgravity and normal Earth gravity, in which there are requirements for dual-species atomic beams, low temperatures, and low pressures. The apparatus includes a pyramidal magneto-optical trap in which the illumination is provided by multiple lasers tuned to frequencies characteristic of the two atomic species. The inlet to the apparatus is located in a vacuum chamber that contains rubidium and cesium atoms at a low pressure; the beam leaving through the outlet of the apparatus is used to transfer the atoms to a higher-vacuum (lower-pressure) chamber in which measurements are performed. The pyramidal magneto-optical trap is designed so that the laser cooling forces in one direction are unbalanced, resulting in a continuous cold beam of atoms that leak out of the trap (see figure). The radiant intensity (number of atoms per unit time per unit solid angle) of the apparatus is the greatest of any other source of the same type reported to date. In addition, this is the first such apparatus capable of producing a slow, collimated beam that contains two atomic species at the same time.

Thompson, Robert

Compact Apparatus Grows Protein Crystals

Laboratory apparatus provides delicately balanced combination of materials and chemical conditions for growth of protein crystals. Apparatus and technique for growth based on hanging-drop method for crystallization of macromolecules. Includes pair of syringes with ganged plungers. One syringe contains protein solution; other contains precipitating-agent solution. Syringes intrude into cavity lined with porous reservoir material saturated with 1 mL or more of similar precipitating-agent solution. Prior to activation, ends of syringes plugged to prevent transport of water vapor among three solutions.

Bugg, Charles E.

Apparatus Makes Precisely Saturated Solutions

Simple laboratory apparatus establishes equilibrium conditions of temperature and concentration in solutions for use in precise measurements of saturation conditions. With equipment typical measurement of saturation concentration of protein in solution established and measured within about 24 hours. Precisely saturated solution made by passing solvent or solution slowly along column packed with solute at precisely controlled temperature. If necessary, flow stopped for experimentally determined interval to allow equilibrium to be established in column.

Pusey, Marc L.

Apparatus for Cold, Pressurized Biogeochemical Experiments

A laboratory apparatus has been devised as a means of studying plausible biogeochemical reactions under high-pressure, low-temperature aqueous, anaerobic conditions like those conjectured to prevail in a liquid water ocean on Europa (the fourth largest moon of the planet Jupiter). The experiments to be performed by use of this apparatus are intended to enhance understanding of how life (if any) could originate and evolve in the Europa ocean environment. Inasmuch as terrestrial barophilic, psychrophilic organisms that thrive under anaerobic conditions are used in the experiments, the experiments may also contribute to terrestrial biogeochemistry. The apparatus (see figure) includes a bolt-closure reaction vessel secured inside a refrigerator that maintains a temperature of 4 C. Pressurized water is supplied to the interior of the vessel by a hydrostatic pump, which is attached to the vessel via high-pressure fittings. The terrestrial organisms used in the experiments thus far have been several facultative barophilic, psychrophilic stains of Shewanella bacteria. In the experiments, these organisms have been tested for reduction of ferric ion by growing them in the presence of a ferric food source under optimized terrestrial conditions. The short-term goal of these experiments has been to select Shewanella strains that exhibit iron-reduction capability and test their ability to facilitate biogeochemical reduction of iron under temperature and pressure conditions imitating those in Europa s ocean. It is anticipated, that, once growth under Europa-like conditions has been achieved, the selected Shewanella strains will be used to facilitate biogeochemical reactions of sulfate and carbonate with hydrogen gas. Any disequilibrium of the products with the environment would be interpreted as signifying biogenic activity and the possibility of life in Europa s ocean.

Amashukeli, Xenia

Apparatus Measures Seebeck Coefficient And Resistivity

Electrical measurements made by four point probes, two of which double as temperature probes. Laboratory apparatus measures both Seebeck coefficients and electrical resistivities of candidate thermoelectric materials at temperatures from ambient to 1,300 K. Apparatus makes possible to take both measurements alternately and in rapid succession during same heating cycle, thereby reducing distortion.

Zoltan, Leslie D.

Study of Systems Using Inertia Wheels for Precise Attitude Control of a Satellite

Systems using inertia wheels are evaluated in this report to determine their suitability for precise attitude control of a satellite and to select superior system configurations. Various possible inertia wheel system configurations are first discussed in a general manner. Three of these systems which appear more promising than the others are analyzed in detail, using the Orbiting Astronomical Observatory as an example. The three systems differ from each other only by the method of damping, which is provided by either a rate gyro, an error-rate network, or a tachometer in series with a high-pass filter. An analytical investigation which consists of a generalized linear analysis, a nonlinear analysis using the switching-time method, and an analog computer study shows that all three systems are theoretically capable of producing adequate response and also of maintaining the required pointing accuracy for the Orbiting Astronomical Observatory of plus or minus 0.1 second of arc. Practical considerations and an experimental investigation show, however, that the system which uses an error-rate network to provide damping is superior to the other two systems. The system which uses a rate gyro is shown to be inferior because the threshold level causes a significant amount of limit-cycle operation, and the system which uses a tachometer with a filter is shown to be inferior because a device with the required dynamic range of operation does not appear to be available. The experimental laboratory apparatus used to investigate the dynamic performance of the systems is described, and experimental results are included to show that under laboratory conditions with relatively large extraneous disturbances, a dynamic tracking error of less than plus or minus 0.5 second of arc was obtained.

White, John S.

Stabilizing Microwave Frequency of a Photonic Oscillator

A scheme for stabilizing the frequency of a microwave signal is proposed that exploits the operational characteristics of a coupled optoelectronic oscillator (COEO) and related optoelectronic equipment. An essential element in the scheme is a fiber mode-locked laser (MLL), the optical frequency of which is locked to an atomic transition. In this scheme, the optical frequency stability of the mode-locked laser is transferred to that of the microwave in the same device. Relative to prior schemes for using wideband optical frequency comb to stabilize microwave signals, this scheme is simpler and lends itself more readily to implementation in relatively compact, rugged equipment. The anticipated development of small, low-power, lightweight, highly stable microwave oscillators based on this scheme would afford great benefits in communication, navigation, metrology, and fundamental sciences. COEOs of various designs, at various stages of development, in some cases called by different names, have been described in a number of prior NASA Tech Briefs articles. A COEO is an optoelectronic apparatus that generates both short (picosecond) optical pulses and a steady microwave signal having an ultrahigh degree of spectral purity. The term "coupled optoelectronic" in the full name of such an apparatus signifies that its optical and electronic oscillations are coupled to each other in a single device. The present frequency-stabilization scheme is best described indirectly by describing the laboratory apparatus used to demonstrate it. The apparatus (see figure) includes a COEO that generates a comb-like optical spectrum, the various frequency components of which interfere, producing short optical pulses. This spectrum is centered at a nominal wavelength of 1,560 nm. The spectrum separation of this comb is about 10 GHz, as determined primarily by the length of an optical loop and the bandpass filter in the microwave feedback loop. The optical loop serves as microwave resonator having a very high value of the resonance quality factor (Q). The optical frequency of MLL is then stabilized by locking it to an atomic transition as described below. The COEO contains a tunable 1-nm band-pass optical filter and a piezoelectric-transducer (PZT) drum over which a stretch of fiber is wound. The 1-nm-wide pass band of the filter provides coarse tuning to overlap the frequency comb with the atomic transition frequency. Controlled stretching of the fiber by means of the PZT drum can be used in conjunction with temperature control for locking the laser frequency. To reference to an atomic resonance at 780 nm in this demonstration setup, the optical output of the COEO at 1,560 nm is fed through an erbium-doped-fiber amplifier (EDFA) to a frequency doubler in the form of a periodically poled lithium niobate (PPLN) crystal. The frequency-doubled output is combined with the output of a separate frequency-stabilized diode laser at a photodetector. As described thus far, the two 780-nm laser subsystems are nominally independent of each other and can, therefore, operate at different frequencies. Hence, at the photodetector, the two laser beams interfere, so that the output of the photodetector includes a beat note (a component at the difference between the two laser frequencies).

Maleki, Lute

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank

An algorithm for attitude identification for SCOLE using two infrared cameras

This report presents an algorithm that incorporates real-time data from two infrared cameras and computes the attitude parameters of the Spacecraft Control Laboratory Experiment (SCOLE), a laboratory apparatus representing an offset-feed antenna attached to the Space Shuttle by a flexible mast. The algorithm utilizes camera position information of three miniature LEDs, mounted on the SCOLE platform, permitting arbitrary camera placement and an on-line attitude extraction. The continuous nature of the algorithm allows identification of the placement of the two cameras with respect to some initial position of the three reference LEDs, followed by on-line six degrees of freedom attitude tracking, regardless of the attitude time history. The report provides a description of the algorithm in the camera identification mode as well as the mode of target tracking. Experimental data from a reduced-size SCOLE-like laboratory model, reflecting the performance of the camera identification and tracking processes, are presented.

Shenhar, J.

Mars - Experimental study of albedo changes caused by dust fallout

A laboratory apparatus was used to simulate the uniform fallout and deposition of particles 1 to 5 microns in diameter in an experimental study on how the spectral and photometric properties of representative Martian areas are affected by fallout of atmospheric dust (smaller than or equalling 60 microns) suspended during dust storms. In this study, measurements are made in the changes in reflectance at optical and near-infrared wavelengths (0.4 to 1.2 micron) caused by deposition of varying amounts of a Mars-analog dust on bright and dark substrates before and after deposition of 6 x 10 to the -5th to 1.5 x 10 to the -3rd g/sq cm of simulated fallout. It is believed that only small amounts of dust particles (approximately 3 x 10 to the -4th g/sq cm) are needed to make significant albedo changes in dark areas of Mars, and that this would rule out uniform dust deposition on the surface of the planet. Data also indicate that other high albedo features like bright crater-related wind streaks may not be areas of significant sediment deposits. Laboratory simulations have permitted estimates of how much the reflectance of an area on Mars would change given a certain amount of dust fallout (g/sq cm) or reflectance data. These simulations may also be useful in tracking the transport and deposition of the dust.

Wells, E. N.

Prediction of hail damage to aircraft.

Description of a hailstone impact simulator, a valuable laboratory apparatus which can be used for such hailstone research as the testing of prospective structural designs or generating data to compare with theory. The simulator consists of a launcher and a velocity-measuring system. It has been successfully used to obtain deformation data on flat sheets and spherical caps of various sizes impacted by hailstones at typical flight velocities. A computer program is described which adequately predicts the damage to a simple structure when impacted by a hailstone.

Hayduk, R. J.

System design considerations for free-fall materials processing

The design constraints for orbiting materials processing systems are dominated by the limitations of the flight vehicle/crew and not by the processes themselves. Although weight, size and power consumption are all factors in the design of normal laboratory equipment, their importance is increased orders of magnitude when the equipment must be used in an orbital facility. As a result, equipment intended for space flight may have little resemblance to normal laboratory apparatus although the function to be performed may be identical. The same considerations influence the design of the experiment itself. The processing requirements must be carefully understood in terms of basic physical parameters rather than defined in terms of equipment operation. Preliminary experiments and analysis are much more vital to the design of a space experiment than they are on earth where iterative development is relatively easy. Examples of these various considerations are illustrated with examples from the M518 and MA-010 systems. While these are specific systems, the conclusions apply to the design of flight materials processing systems both present and future.

Seidensticker, R. G.

Two-directional active damper

Damper system to be used in studies of payload isolation technology is suitable as a laboratory apparatus. It provides easily adjustable damping and acts as multichannel shaker system.

Chang, C. S.

Feasibility of an advanced thrust termination assembly for a solid propellant rocket motor

A total of 68 quench tests were conducted in a vented bomb assembly (VBA). Designed to simulate full-scale motor operating conditions, this laboratory apparatus uses a 2-inch-diameter, end-burning propellant charge and an insulated disc of consolidated hydrated aluminum sulfate along with the explosive charge necessary to disperse the salt and inject it onto the burning surface. The VBA was constructed to permit variation of motor design parameters of interest; i.e., weight of salt per unit burning surface area, weight of explosive per unit weight of salt, distance from salt surface to burning surface, incidence angle of salt injection, chamber pressure, and burn time. Completely satisfactory salt quenching, without re-ignition, occurred in only two VBA tests. These were accomplished with a quench charge ratio (QCR) of 0.023 lb salt per square inch of burning surface at dispersing charge ratios (DCR) of 13 and 28 lb of salt per lb of explosive. Candidate materials for insulating salt charges from the rocket combustion environment were evaluated in firings of 5-inch-diameter, uncured end-burner motors. A pressed, alumina ceramic fiber material was selected for further evaluation and use in the final demonstration motor.

Source record

A perceptual channel for information transfer over kilometer distances Historical perspective and recent research

For more than 100 years, scientists have attempted to determine the truth or falsity of claims for the existence of a perceptual channel whereby certain individuals are able to perceive and describe remote data not presented to any known sense. This paper presents an outline of the history of scientific inquiry into such so-called paranormal perception and surveys the current state of the art in parapsychological research in the United States and abroad. The nature of this perceptual channel is examined in a series of experiments carried out in the Electronics and Bioengineering Laboratory of Stanford Research Institute. The perceptual modality most extensively investigated is the ability of both experienced subjects and inexperienced volunteers to view, by innate mental processes, remote geographical or technical targets including buildings, roads, and laboratory apparatus. The accumulated data indicate that the phenomenon is not a sensitive function of distance, and Faraday cage shielding does not in any apparent way degrade the quality and accuracy of perception. On the basis of this research, some areas of physics are suggested from which a description or explanation of the phenomenon could be forthcoming.

Puthoff, H. E.