Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “L1B”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Soil Moisture Active Passive (SMAP) Project Algorithm Theoretical Basis Document SMAP L1B Radiometer Data Product: L1B_TB

The purpose of the Soil Moisture Active Passive (SMAP) radiometer calibration algorithm is to convert Level 0 (L0) radiometer digital counts data into calibrated estimates of brightness temperatures referenced to the Earth's surface within the main beam. The algorithm theory in most respects is similar to what has been developed and implemented for decades for other satellite radiometers; however, SMAP includes two key features heretofore absent from most satellite borne radiometers: radio frequency interference (RFI) detection and mitigation, and measurement of the third and fourth Stokes parameters using digital correlation. The purpose of this document is to describe the SMAP radiometer and forward model, explain the SMAP calibration algorithm, including approximations, errors, and biases, provide all necessary equations for implementing the calibration algorithm and detail the RFI detection and mitigation process. Section 2 provides a summary of algorithm objectives and driving requirements. Section 3 is a description of the instrument and Section 4 covers the forward models, upon which the algorithm is based. Section 5 gives the retrieval algorithm and theory. Section 6 describes the orbit simulator, which implements the forward model and is the key for deriving antenna pattern correction coefficients and testing the overall algorithm.

microwave radiometers↗

VIIRS Thermal Emissive Bands L1B Calibration Uncertainty

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key instrument on-board the Suomi National Polar-orbiting Partnership (S-NPP) spacecraft. The S-NPP launched in October 2011 and it has been collecting valuable Earth science data with VIIRS and four other instruments for more than five years. The VIIRS Characterization Support Team (VCST) of the National Aeronautics and Space Administration (NASA) Science Investigator-led Processing Systems (SIPS) is designed to support the VIIRS sensor pre-launch geometric and radiometric characterization and to access on-orbit long-term Level-1B (L1B) calibration and performance. This paper reviews the VIIRS thermal emissive bands (TEB), covering wavelengths from 3.7 to 12.0 μm, L1B radiometric calibration algorithms and presents the calibration uncertainty methodology which will be implanted in the L1B processing software. Discussions will be focused on the key uncertainty parameters and the application in L1B.

S-NPP VIIRS TEB Uncertainty↗

Status of the Terra and Aqua Modis Collection 7 L1B

The MODIS instruments on the Terra and Aqua spacecrafts have successfully operated for more than 23 and 21years, respectively, and have far exceeded their designed lifetimes of 6 years. The visible, near infrared, and short-wave infrared spectral bands, with wavelengths from 0.41 to 2.2 μm, are calibrated using the on-board solar diffuser. Themid-wave infrared and long-wave infrared spectral bands are calibrated using a blackbody. The sustained calibration and characterization efforts undertaken by the MODIS Characterization Support Team (MCST) have resulted in several upgrades to the Level-1B (L1B) algorithms over the mission lifetime. The latest version of the L1B algorithm, designated as Collection 7 (C7), was developed based upon observed performance of the current operational L1B product (C6.1), changing instrument behavior, and feedback from the science community. This paper provides an overview of the C7 algorithm and its improvements over the previous data collection, as well as some of the updates that have been incorporated since the first delivery in early 2021.

Amit Angal↗

GOES-R L1b Readiness Implementation and Management Plan

A complement of Readiness, Implementation and Management Plans (RIMPs) to facilitate management of post-launch product test activities for the official Geostationary Operational Environmental Satellite (GOES-R) Level 1b (L1b) products have been developed and documented. Separate plans have been created for each of the GOES-R sensors including: the Advanced Baseline Imager (ABI), the Extreme ultraviolet and X-ray Irradiance Sensors (EXIS), Geostationary Lightning Mapper (GLM), GOES-R Magnetometer (MAG), the Space Environment In-Situ Suite (SEISS), and the Solar Ultraviolet Imager (SUVI). The GOES-R program has implemented these RIMPs in order to address the full scope of CalVal activities required for a successful demonstration of GOES-R L1b data product quality throughout the three validation stages: Beta, Provisional and Full Validation. For each product maturity level, the RIMPs include specific performance criteria and required artifacts that provide evidence a given validation stage has been reached, the timing when each stage will be complete, a description of every applicable Post-Launch Product Test (PLPT), roles and responsibilities of personnel, upstream dependencies, and analysis methods and tools to be employed during validation. Instrument level Post-Launch Tests (PLTs) are also referenced and apply primarily to functional check-out of the instruments.

Validation Readiness↗

MODIS TEB Calibration Algorithm Improvements for Future L1B Collection

Terra and Aqua MODIS have provided continuous global observations for scientific applications for more than 20 and 18 years, respectively. The radiometric calibration of the MODIS thermal emissive bands (TEB) is based on a quadratic approximation of the instrument response. The calibration coefficients look-up tables (LUTs) are updated using the response of the MODIS on-board blackbody (BB)with the response background subtracted by space view. The quarterly on-board BB warm-up and cool-down activity temperature ranges from 270 K to 315 K, and the derived offset has a relatively large uncertainty. Electronic cross-talk, an artifact that affects both instrument calibration and Earth view (EV) radiance retrievals, is corrected based on lunar observations. Calibration assessments using EV observations (e.g. ocean, desert, Antarctic Dome Concordia, and deep convective clouds) provide useful information to evaluate the impact of the Terra safe mode (February 2016) and Aqua MODIS formatter reset (January 2018) events on both MODIS instruments. This study focuses on the TEB radiometric calibration algorithm improvements for future collections based on calibration assessments using EV measurements and analytical modeling. Measurement stability and consistency over specific Earth scenes with a wide temperature range, as well as their brightness temperature (BT) dependency, are used for bias estimations in the calibration coefficients. Calibration coefficients are derived and updated after adjusting the current fitting algorithm. Thereafter, using the test LUTs, their impact on the Level 1B (L1B) data for different EV scenes is analyzed.

MODIS↗

MODIS TEB Electronic Crosstalk Correction Update and Impact on L1B Product Uncertainty

The MODIS instruments onboard the Terra and Aqua satellites have been in operation for over22 and 20 years, respectively. The instruments’ calibration accuracy has been maintained, even with instrument degradation. Electronic crosstalk in the thermal emissive bands (TEB) is a known issue with an increasing impact on the calibration and product. The Terra MODIS photovoltaic (PV) longwave infrared (LWIR) bands crosstalk corrections have been applied in Collection 6.1 (C6.1). However, the electronic crosstalk contamination for some detectors in the mid-wave infrared (MWIR) bands and the Aqua PVLWIR bands affect the Level-1B (L1B) product’s measurement accuracy and image quality. In Collection 7 (C7), crosstalk corrections for select detectors in the Terra and Aqua MWIR and Aqua PV LWIR bands are applied. The entire mission crosstalk coefficients for the select detectors and bands are derived from scheduled lunar observations and populated in the form of look-up tables (LUTs). The Aqua PV-LWIR bands exhibit similar downward crosstalk trends as the Terra PV-LWIR bands, especially in recent years. The crosstalk coefficients and their trends provide a guideline for the correction application. Earth measurement analyses before and after the correction provide contamination and correction assessments. It has been shown that the product quality is enhanced with the crosstalk correction applied in C7. For C7, the crosstalk coefficient uncertainty is derived from the fit residuals between the measured values and a linear fit over a three-year sliding window. The uncertainty propagation is modeled and applied in the total uncertainty calculation intheL1B product. The TEB electronic crosstalk LUTs have been processed over the entire Terra and Aqua MODIS missions. This paper presents the C7 crosstalk correction, as well as its assessment and uncertainty propagation algorithm to the TEB uncertainty.

Tiejun Chang↗

An Assessment of SNPP and NOAA20 VIIRS RSB Calibration Performance in NASA SIPS Reprocessed Collection-2 L1B Data Products

Two VIIRS sensors onboard the SNPP and NOAA20 satellites have been successfully operating for over 10 and 4 years, respectively, providing the worldwide user community with high-quality imagery and radiometric measurements of the land, atmosphere, cryosphere, and oceans. This study provides a temporal radiometric stability and calibration consistency assessment of the SNPP and NOAA20 VIIRS reflective solar bands using the latest NASA SIPS C2 L1B products. Several independent vicarious approaches are used to examine the stability of SNPP VIIRS and consistency of the at-sensor reflectance between the two VIIRS instruments. These approaches include observations from simultaneous nadir overpasses, the Libya-4 desert and Dome C snow/ice sites, and deep convective clouds. The impact of existing band spectral differences on the reflectance measurements is accounted for utilizing scene-specific hyperspectral observations provided by the SCIAMACHY sensor onboard the ENVISAT platform. Results indicate that both SNPP and NOAA20 VIIRS reflectances are stable within 1% over their mission periods for all bands, except for a few bands in the visible range from SNPP VIIRS that show more upward drifts at high radiances. NOAA20 VIIRS reflectances are systematically lower than SNPP by 2 to 4% for most bands, with the exception of few short wavelength bands where it is seen to be up to 7%.

VIIRS↗

Modis TEB Electronic Crosstalk Correction Update and Impact on L1B Product Uncertainty

The MODIS instruments on board the Terra and Aqua satellites have been in operation for over 22 and 20 years, respectively. The instruments’ calibration accuracy has been maintained, even with instrument degradation. Electronic crosstalk in the thermal emissive bands (TEB) is a known issue with an increasing impact on the calibration and product. The Terra MODIS photovoltaic (PV) longwave infrared (LWIR) bands crosstalk corrections have been applied in Collection 6.1 (C6.1). However, the electronic crosstalk contamination for some detectors in the mid-wave infrared(MWIR) bands and the Aqua PVLWIR bands affect the Level-1B(L1B) product’s measurement accuracy and image quality. In Collection 7 (C7), crosstalk corrections for select detectors in the Terra and Aqua MWIR and Aqua PV LWIR bands are applied. The entire mission crosstalk coefficients for the select detectors and bands are derived from scheduled lunar observations and populated in the form of look-up tables (LUTs). The Aqua PV-LWIR bands exhibit similar downward crosstalk trends as the Terra PV-LWIR bands, especially in recent years. The crosstalk coefficients and their trends provide a guideline for the correction application. Earth measurement analyses before and after the correction provide contamination and correction assessments. It has been shown that the product quality is enhanced with the crosstalk correction applied in C7. For C7, the crosstalk coefficient uncertainty is derived from the fit residuals between the measured values and a linear fit over a three-year sliding window. The uncertainty propagation is modeled and applied in the total uncertainty calculation intheL1B product. The TEB electronic cross talk LUT shave been processed over the entire Terra and Aqua MODIS missions. This paper presents the C7 crosstalk correction, as well as its assessment and uncertainty propagation algorithm to the TEB uncertainty.

Tiejun Chang↗

Status of the Moderate-resolution Imaging Spectroradiometer Level 1B Algorithm

The Moderate-resolution Imaging Spectroradiometer (MODIS) instruments are on-board the Aqua and Terra spacecraft, launched in 2002 and 1999, respectively. Since beginning operation, they have continued to collect valuable remote sensing data of the Earth in 36 spectral bands ranging in wavelengths from 0.41 to 14.5 μm. The Level 1B (L1B) algorithm produces calibrated top of the atmosphere (TOA) radiances for each Earth-view (EV) pixel and calibrated TOA reflectances for the reflective solar bands using geo-located, uncalibrated instrument data and calibration look up tables (LUTs) produced regularly by the MODIS Characterization Support Team (MCST). The L1B algorithm also calculates an uncertainty value for each EV pixel. The calibrated radiance and reflectance products are used to generate higher-level science products. A separate L1B code version is maintained for both MODIS instruments so that sensor specific issues can be handled individually. The current L1B algorithm version produces the Collection 6.1 (C6.1) products and was released in 2017. An overview of the C6.1 algorithm is provided together with improvements made since its release. Also discussed briefly are the planned improvements in the Collection 7 L1B algorithm.

MODIS↗

Time-Dependent Response Versus Scan Angle for MODIS Reflective Solar Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments currently operate onboard the National Aeronautics and Space Administration (NASA's) Terra and Aqua spacecraft, launched on December 18, 1999 and May 4, 2002, respectively. MODIS has 36 spectral bands, among which 20 are reflective solar bands (RSBs) covering a spectral range from 0.412 to 2.13 μm. The RSBs are calibrated on orbit using a solar diffuser (SD) and an SD stability monitor and with additional measurements from lunar observations via a space view (SV) port. Selected pseudo-invariant desert sites are also used to track the RSB on-orbit gain change, particularly for short-wavelength bands. MODIS views the Earth surface, SV, and the onboard calibrators using a two-sided scan mirror. The response versus scan angle (RVS) of the scan mirror was characterized prior to launch, and its changes are tracked using observations made at different angles of incidence from onboard SD, lunar, and Earth view (EV) measurements. These observations show that the optical properties of the scan mirror have experienced large wavelength-dependent degradation in both the visible and near infrared spectral regions. Algorithms have been developed to track the on-orbit RVS change using the calibrators and the selected desert sites. These algorithms have been applied to both Terra and Aqua MODIS Level 1B (L1B) to improve the EV data accuracy since L1B Collection 4, refined in Collection 5, and further improved in the latest Collection 6 (C6). In C6, two approaches have been used to derive the time-dependent RVS for MODIS RSB. The first approach relies on data collected from sensor onboard calibrators and mirror side ratios from EV observations. The second approach uses onboard calibrators and EV response trending from selected desert sites. This approach is mainly used for the bands with much larger changes in their time-dependent RVS, such as the Terra MODIS bands 1-4, 8, and 9 and the Aqua MODIS bands 8- and 9. In this paper, the algorithms of these approaches are described, their performance is demonstrated, and their impact on L1B products is discussed. In general, the shorter wavelength bands have experienced a larger on-orbit RVS change, which, in general, are mirror side and detector dependent. The on-orbit RVS change due to the degradation of band 8 can be as large as 35 percent for Terra MODIS and 20 percent for Aqua MODIS. Vital to maintaining the accuracy of the MODIS L1B products is an accurate characterization of the on-orbit RVS change. The derived time-independent RVS, implemented in C6, makes an important improvement to the quality of the MODIS L1B products.

MODIS↗

Status of the MODIS Level 1B Algorithms and Calibration Tables

The Moderate Resolution Imaging Spectroradiometer (MODIS) makes observations using 36 spectral bands with wavelengths from 0.41 to 14.4 m and nadir spatial resolutions of 0.25km, 0.5km, and 1km. It is currently operating onboard the NASA Earth Observing System (EOS) Terra and Aqua satellites, launched in December 1999 and May 2002, respectively. The MODIS Level 1B (L1B) program converts the sensor's on-orbit responses in digital numbers to radiometrically calibrated and geo-located data products for the duration of each mission. Its primary data products are top of the atmosphere (TOA) reflectance factors for the sensor's reflective solar bands (RSB) and TOA spectral radiances for the thermal emissive bands (TEB). The L1B algorithms perform the TEB calibration on a scan-by-scan basis using the sensor's response to the on-board blackbody (BB) and other parameters which are stored in Lookup Tables (LUTs). The RSB calibration coefficients are processed offline and regularly updated through LUTs. In this paper we provide a brief description of the MODIS L1B calibration algorithms and associated LUTs with emphasis on their recent improvements and updates developed for the MODIS collection 5 processing. We will also discuss sensor on-orbit calibration and performance issues that are critical to maintaining L1B data product quality, such as changes in the sensor's response versus scan-angle.

MODIS LEVEL 1B ALGORITHMS↗

Updates of Moderate Resolution Imaging Spectroradiometer On-Orbit Calibration Uncertainty Assessments

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments have successfully operated for more than 18 and 16 years, respectively, on-board the NASA’s Earth Observing System Terra and Aqua spacecraft. Both Terra and Aqua MODIS have significantly contributed to the advance of global Earth remote sensing applications with a broad range of science products that have been continuously produced since the beginning of each mission and freely distributed to users worldwide. MODIS collects data in 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB), covering wavelengths from 0.41 to 14.4 μm. Its level 1B (L1B) data products, which provide the input for the MODIS high-level science products, include the top of the atmosphere reflectance factors for the RSB, radiances for both the RSB and TEB, and associated uncertainty indices (UI) at a pixel-by-pixel level. This paper provides a brief review of MODIS L1B calibration algorithms, including a number of improvements made in recent years. It presents an update of sensor calibration uncertainty assessments with a focus on several new contributors resulting from on-orbit changes in sensor characteristics, approaches developed to address these changes, and the impact due to on-orbit changes on the L1B data quality. Also discussed are remaining challenges and potential improvements to be made to continuously maintain sensor calibration and data quality, particularly those related to the quality of MODIS L1B uncertainty.

Spectroradiometer↗

Assessment of Terra MODIS Thermal Emissive Band Calibration Using Cold Targets and Measurements in Lunar Roll Events

Terra MODIS has provided continuous global observations for science research and applications for more than 18 years. The MODIS Thermal emissive bands (TEB) radiometric calibration uses a quadratic function for instrument response. The calibration coefficients are updated using the response of an on-board blackbody (BB) in quarterly warm-up and cool-down (WUCD) events. As instrument degradation and electronic crosstalk of long-wave infrared (LWIR) bands 27 to 30 developed substantial issues, accurate calibration is crucial for a high-quality L1B product. The on-board BB WUCD temperature ranges from 270 K to 315 K and the derived nonlinear response has a relatively large uncertainty for the offset, especially for these LWIR bands, which affects the measurements of low brightness temperature (BT) scenes. In this study, the TEB radiometric calibration impact on the L1B product is assessed using selected cold targets and the measurements during regular lunar rolls. The cold targets include Antarctic Dome Concordia (Dome-C) and deep convective clouds (DCC) for the calibration assessment, focusing on bands 27 to 30. Dome-C area is covered with uniformly-distributed permanent snow, and the atmospheric effect is small and relatively constant. Usually the DCC is treated as an invariant earth target to evaluate the reflective solar band calibration. The DCC can also be treated as a stable target to assess the performance of TEB calibration. During a scheduled lunar observation event with a spacecraft roll maneuver to view the moon through the space view port, the instrument cavity provides a stable reference for calibration assessment. The long-term trending of BT measurements and the relative difference between scan mirror sides and detectors are used for the assessment of the calibration consistency and stability. The comparison of L1B products over the selected targets before and after the calibration coefficients update can be used to assess the impact of a calibration look-up table (LUT) update. This assessment is beneficial for future calibration algorithm and LUT update procedure improvements for enhancing the L1B product quality.

Chang, Tiejun↗