Operational Performance Characteristics of an Aerated L-valve Operated Within a Closed Circulating Fluidized Bed Loop

An experimental study was conducted in a large scale circulating fluidized bed (0.3 m diameter ×15.5 m tall) equipped with nonmechanical L-valve (0.25 m diameter ×1.52 m long) varying the riser superficial gas velocity (U g ), bed inventory (m), L-valve aeration velocity (U Lvalve ) and standpipe aeration velocity (U move ). The effects of these operational parameters on pressure drop were investigated in each of the different components in the CFB and on the solid circulation rate with two different Group B particles (180 μm glass bead and 750 μm phosphorescent polyethylene beads, PPE). Tests were carried out at ambient temperature and pressure conditions using air as the fluidization gas. The operating parameters were shown to significantly affect pressure drops across various sections of the CFB due to redistribution of solids within the system. The pressure drop in the horizontal section of the L-valve was affected by aeration rates in addition to the solid flow rate reported in previous studies of smaller L-valves without aeration. A new dimensionless semi-empirical correlation was able to explain > 98% of the variance between pressure drop across the horizontal section of the L-valve and operating parameters for these Group B particles. The results of present study indicated that the nonmechanical L-valve cannot be isolated from the CFB system for performance evaluation.

Monazam, Esmail R.↗

Analysis of Solids Flow Rate through Nonmechanical L-Valve in an Industrial-Scale Circulating Fluidized Bed Using Group B Particles

A series of statistically designed experiments were conducted using two different Geldart Group B particles in a 0.3 m diameter circulating fluidized bed (CFB) cold model to evaluate the nonmechanical L-valve for controlling the solids flow rate. The objective of this study was to investigate the effects of standpipe aeration, L-valve aeration, solids inventory, and superficial gas velocity through the riser on the solids flow rate. A stochastic correlation was developed for calculating the solid flow rate as a function of these variables. It was found that the solid flow rate increased directly proportional to each of these variables. Dimensional analysis was used to generate an expression for the solids turnover ratio. The model developed in the present study is intended to simulate flow in the present CFB loop. In conclusion, it is not intended for scale-up and will probably not apply for alternative CFB loops with different geometries/pressure balance conditions.

42 ENGINEERING↗

Particle Handling in Particle-Based Pumped Thermal Energy Storage

A particle-based pumped thermal electricity storage system stores high-temperature heat (~1000 degrees C) in low-cost silica sand and generates power through an efficient power cycle. Central to this system is a counterflow direct-contact gas/particle fluidized-bed heat exchanger, which can significantly improve the heat exchange process due to the large heat transfer surface area of particles. To showcase a lab-scale 10- to 20-kWe heat exchange process with particles heating up to 300 degrees C, a comprehensive hydrodynamic analysis of the fluidization condition inside the heat exchanger was conducted. The heat exchanger was designed to target for heat exchange process of 10-20 kW and accommodate an air mass flow rate of 0.3-0.7 kg/s. The fluidization condition was set to maintain stable bubbling fluidization, thereby maximizing the particle-to-air heat transfer. An air distributor was designed to equally distribute air over the bed, which can avoid defluidized zones in the heat exchanger. Additionally, particle handling systems including L-valves, screw conveyors, and pneumatic conveyors were developed for the prototype heat exchanger, efficiently conveying high-temperature particles at 0.2-0.5 kg/s. This work lays the foundation for scaling up the system and integrating it into larger energy storage applications, demonstrating its potential for efficient, high-temperature thermal energy storage and power generation.

25 ENERGY STORAGE↗

Dynamic analysis of a circulating fluidized bed riser

A linear state model is proposed to analyze dynamic behavior of a circulating fluidized bed riser. Different operating regimes were attained with high density polyethylene beads at low and high system inventories. The riser was operated between the classical choking velocity and the upper transport velocity demarcating fast fluidized and transport regimes. At a given riser superficial gas velocity, the aerations fed at the standpipe were modulated resulting in a sinusoidal solids circulation rate that goes into the riser via L-valve. The state model was derived based on the mass balance equation in the riser. It treats the average solids fraction across the entire riser as a state variable. The total riser pressure drop was modeled using Newton’s second law of motion. The momentum balance equation involves contribution from the weight of solids and the wall friction caused by the solids to the riser pressure drop. The weight of solids utilizes the state variable and hence, the riser inventory could be easily calculated. The modeling problem boils down to estimating two parameters including solids friction coefficient and time constant of the riser. It has been shown that the wall friction force acts in the upward direction in fast fluidized regime which indicates that the solids were moving downwards on the average with respect to the riser wall. In transport regimes, the friction acts in the opposite direction. This behavior was quantified based on a sign of Fanning friction factor in the momentum balance equation. The time constant of the riser appears to be much higher in fast fluidized regime than in transport conditions.

42 ENGINEERING↗

Physically-based control-oriented modeling for turbocharged stoichiometric spark-ignited engine with cooled EGR and flexible VVT systems

Accurate estimation and prediction of engine gas exchange system and in-cylinder conditions are critical for spark-ignited engine control and diagnostic algorithm development. In this paper, a physically-based, control-oriented model for a 2.8 l turbocharged, variable valve timing (VVT) and low pressure (LP) exhaust gas recirculation (EGR)-utilizing SI engine was developed. The model includes the impact of modulation to any combination of 10 actuators, including the throttle valve, compressor bypass valve, fueling rate, waste-gate, LP EGR valve, number of deactivated cylinders, intake valve open (IVO) timing, intake valve close (IVC) timing, exhaust valve open (EVO) timing and exhaust valve close (EVC) timing. The accuracy of the model in capturing engine dynamics was demonstrated by validating it against high-fidelity engine GT-Power simulation results for various drive cycles, particularly emphasizing elevated loads. In comparison to the open literature, novel contributions of the effort described in this paper includes in-cylinder gas composition modeling and turbine-out pressure estimation.

Zhang, Xu↗

Fluid check valve has fail-safe feature

Check valve ensures unidirectional fluid flow and, in case of failure, vents the downstream fluid to the atmosphere and gives a positive indication of malfunction. This dual valve consists of a master check valve and a fail-safe valve.

Gaul, L. C.↗

Use of thermocapillary migration in a controllable heat valve

In accordance with the Marangoni effect, immiscible droplets in a host fluid in which a temperature gradient exists move in the direction of increasing temperature. It is proposed that this thermocapillary migration could be used to construct a 'liquid wick' that would return the condensed vapor at the condenser end of a heat pipe back to the evaporator, thus completing the fluid circuit. The droplets would be formed by capillary pressure forcing the condensate through a perforated diaphragm whose temperature would control the droplet flux, and hence the heat flux between the two ends of the heat pipe, thus making it a controllable heat valve.

Schmid, L. A.↗

Cycle isolation monitoring

There are many factors to monitor in power plants, but one that is frequently overlooked is cycle isolation. Often this is an area where plant personnel can find 'low hanging fruit' with great return on investment, especially high energy valve leakage. This type of leakage leads to increased heat rate, potential valve damage and lost generation. The fundamental question to ask is 'What is 100 Btu/kW-hr of heat rate worth to your plant? On a 600 MW coal-fired power plant, a 1% leakage can lead to an 81 Btu/kW-hr impact on the main steam cycle and a 64 Btu/kW-hr impact on the hot reheat cycle. The article gives advice on methods to assist in detecting leaking valves and to monitor cycle isolation. A software product, TP. Plus-CIM was designed to estimate flow rates of potentially leaking valves.

20 FOSSIL-FUELED POWER PLANTS↗

Complementary Measurements of Residual Stresses Before and After Base Plate Removal in an Intricate Additively-Manufactured Stainless-Steel Valve Housing

Residual stress measurements using neutron diffraction and the contour method were performed on a valve housing made from 316 L stainless steel powder with intricate three-dimensional internal features using laser powder-bed fusion additive manufacturing. The measurements captured the evolution of the residual stress fields from a state where the valve housing was attached to the base plate to a state where the housing was cut free from the base plate. Making use of this cut, thus making it a non-destructive measurement in this application, the contour method mapped the residual stress component normal to the cut plane (this stress field is completely relieved by cutting) over the whole cut plane, as well as the change in all stresses in the entire housing due to the cut. The non-destructive nature of the neutron diffraction measurements enabled measurements of residual stress at various points in the build prior to cutting and again after cutting. Good agreement was observed between the two measurement techniques, which showed large, tensile build-direction residual stresses in the outer regions of the housing. The contour results showed large changes in multiple stress components upon removal of the build from the base plate in two distinct regions: near the plane where the build was cut free from the base plate and near the internal features that act as stress concentrators. These observations should be useful in understanding the driving mechanisms for builds cracking near the base plate and to identify regions of concern for structural integrity. Neutron diffraction measurements were also used to show the shear stresses near the base plate were significantly lower than normal stresses, an important assumption for the contour method because of the asymmetric cut.

36 MATERIALS SCIENCE↗

Space Shuttle reaction control system thruster metal nitrate removal and characterization

The Space Shuttle hypergolic primary reaction control system (PRCS) thrusters continue to fail-leak or fail-off at a rate of approximately 1.5 per flight, attributed primarily to metal nitrate formation in the nitrogen tetroxide (N2O4) pilot operated valves (POV's). The failures have continued despite ground support equipment (GSE) and subsystem operational improvements. As a result, the Johnson Space Center (JSC) White Sands Test Facility (WSTF) performed a study to characterize the contamination in the N204 valves. This study prompted the development and implementation of a highly successful flushing technique using deionized (DI) water and gaseous nitrogen (GN2) to remove the contamination while minimizing Teflon seat damage. Following flushing a comprehensive acceptance test is performed before the thruster is deemed recovered. Between the time WSTF was certified to process flight thrusters (March 1992) and September 1993, a 68 percent thruster recovery rate was achieved. The contamination flushed from these thrusters was analyzed and has provided insight into the corrosion process, which is reported in this publication. Additionally, the long-term performance of 24 flushed thrusters installed in the WSTF Fleet Leader Shuttle reaction control subsystem (RCS) test articles is being assessed. WSTF continues to flush flight and test article thrusters and compile data to investigate metal nitrate formation characteristics in leaking and nonleaking valves.

Saulsberry, R. L.↗

Harmonic engine

An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a harmonic oscillator inlet valve capable of oscillating at a resonant frequency for controlling the flow of working fluid into of the engine. In particular, the inlet valve includes an inlet valve head and a spring arranged together as a harmonic oscillator so that the inlet valve head is moveable from an unbiased equilibrium position to a biased closed position occluding an inlet. Upon releasing the inlet valve the inlet valve head undergoes a single oscillation past the equilibrium positio to a maximum open position and returns to a biased return position close to the closed position to choke the flow and produce a pressure drop across the inlet valve causing the inlet valve to close. Protrusions carried either by the inlet valve head or piston head are used to bump open the inlet valve from the closed position and initiate the single oscillation of the inlet valve head, and protrusions carried either by the outlet valve head or piston head are used to close the outlet valve ahead of the bump opening of the inlet valve.

42 ENGINEERING↗

Attenuation of Sinusoidal Perturbations Superimposed on Laminar Flow of a Liquid in a Long Line

The attenuation constant for sinusoidal pressure and flow perturbations superimposed on the laminar flow of a viscous liquid was measured in a system consisting of a long, straight, cylindrical hydraulic line. The upstream and downstream ends of the line were securely fastened t o the ground. A sinusoidal perturbation was imposed on the mean flow at the upstream end by means of a s m a l l oscillation of a throttle valve abmt a partly open mean position. The downstream end was terminated in a restricting orifice. Pressure perturbations were measured at three locations along the line for frequencies from 15 t o 100 cps. These pressure measurements were reduced by use of a pair of complex damped acoustic one-dimensional wave equations to obtain the attenuation constant along with the phase constant and the dimensionless downstream admittance. For the range of frequencies investigated, the experimental values of the attenuation constant are in good agreement with classical theory.

PERTURBATION↗

Influence of gas injection location and magnetic perturbations on ICRF antenna performance in ASDEX Upgrade

In ASDEX Upgrade H-modes with H{sub 98}≈0.95, similar effect of the ICRF antenna loading improvement by local gas injection was observed as previously in L-modes. The antenna loading resistance R{sub a} between and during ELMs can increase by more than 25% after a switch-over from a deuterium rate of 7.5⋅10{sup 21} D/s injected from a toroidally remote location to the same amount of deuterium injected close to an antenna. However, in contrast to L-mode, this effect is small in H-mode when the valve downstream w.r.t. parallel plasma flows is used. In L-mode, a non-linearity of R{sub a} at P{sub ICRP}<30 kW is observed when using the gas valve integrated in antenna. Application of magnetic perturbations (MPs) in H-mode discharges leads to an increase of R{sub a}>30% with no effect of spectrum and phase of MPs on R{sub a} found so far. In the case ELMs are fully mitigated, the antenna loading is higher and steadier. In the case ELMs are not fully mitigated, the value of R{sub a} between ELMs is increased. Looking at the W source modification for the improved loading, the local gas injection is accompanied by decreased values of tungsten (W) influx Γ{sub W} from the limiters and its effective sputtering yield Y{sub w}, with the exception of the locations directly at the antenna gas valve. Application of MPs leads to increase of Γ{sub W} and Y{sub w} for some of the MP phases. With nitrogen seeding in the divertor, ICRF is routinely used to avoid impurity accumulation and that despite enhanced Γ{sub W} and Y{sub W} at the antenna limiters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗