Numerical solutions of knudsen flow entering a circular tube through a small axial orifice
Solutions for knudsen flow flux distributions with particles entering circular tube through small axial orifice - rocket thrustor application
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Solutions for knudsen flow flux distributions with particles entering circular tube through small axial orifice - rocket thrustor application
Monte carlo computer solutions of knudsen and near-knudsen flow through wide, parallel, and skewed flat plates
A new apparatus using vacuum ultraviolet single photon ionization mass spectrometry (VUV SPIMS) of an effusive molecular beam emanating from a Knudsen flow reactor is described. It was designed to study free radical-molecule kinetics over a significant temperature range (300–630 K). Its salient features are: (1) external free radical source, (2) counterpropagating molecular beam and diffuse VUV photon beam meeting in a crossed-beam ion source of a quadrupole mass spectrometer with perpendicular ion extraction, (3) analog detection of the photocurrent of the free radical molecular cation, and (4) possibility of detecting both free radicals and closed shell species in the same apparatus and under identical reaction conditions owing to the presence of photoelectrons generated by the photoelectric effect of the used VUV-photons. The measured thermal molecular beam-to-background ratio was 6.35 ± 0.39 for Ar and 10.86 ± 1.59 for i-C{sub 4}H{sub 10} at 300 K, a factor of 2.52 and 1.50 smaller, respectively, than predicted from basic gas-dynamic considerations. Operating parameters as well as the performance of key elements of the instrument are presented and discussed. Coupled to an external free radical source a steady-state specific exit flow of 1.6 × 10{sup 11} and 5.0 × 10{sup 11} molecule s{sup −1} cm{sup −3} of C{sub 2}H{sub 5}{sup •} (ethyl) and t-C{sub 4}H{sub 9}{sup •} (t-butyl) free radicals have been detected using VUV SPIMS at their molecular ion m/z 29 and 57, respectively, at 300 K.
Gas sorption and non-Darcy flow are two important issues for shale gas reservoirs. The sorption consists of dissolution and adsorption. Dissolved gas and adsorbed gas are different. The former is dissolved in the shale matrix, while the latter is concentrated near the solid walls of pores. In this paper, the Langmuir equation is used to describe adsorption and Henry’s law is used to describe dissolution. The K coefficient in Henry’s law of 0.052 mmol/(MPa g TOC) is obtained by matching experimental data. The amount of dissolved gas increases linearly when pressure increases. Using only the Langmuir equation without considering dissolution can lead to a significant underestimation of the amount of sorbed gas in shales. For non-Darcy gas flow, the apparent permeability model for free gas is established by combining slip flow and Knudsen flow. For adsorbed gas, the surface diffusion effect is also considered in this model. Here, the surface diffusion coefficient is suggested to be of the same scale as the gas self-diffusion coefficient, and the corresponding effective permeability is derived. When
Rarefied gas dynamics - plane poiseuille flow between two parallel plates with a minimum as function of knudsen number
The direct simulation Monte Carlo (DSMC) method is a powerful particle-based method for modeling gas flows. It works well for relatively large Knudsen (Kn) numbers, typically larger than 0.01, but quickly becomes computationally intensive as Kn decreases due to its time step and cell size limitations. An alternative approach was proposed to relax or remove these limitations, based on replacing pairwise collisions with a stochastic model corresponding to the Fokker–Planck equation [J. Comput. Phys., 229, 1077 (2010); J. Fluid Mech., 680, 574 (2011)]. Similar to the DSMC method, the downside of that approach suffers from computationally statistical noise. To solve the problem, a diffusion-based information preservation (D-IP) method has been developed. The main idea is to track the motion of a simulated molecule from the diffusive standpoint, and obtain the flow velocity and temperature through sampling and averaging the IP quantities. To validate the idea and the corresponding model, several benchmark problems with Kn ∼ 10{sup −3}–10{sup −4} have been investigated. It is shown that the IP calculations are not only accurate, but also efficient because they make possible using a time step and cell size over an order of magnitude larger than the mean collision time and mean free path, respectively.
This paper develops a dynamic model for pressure sensors in continuum and rarefied flows with longitudinal temperature gradients. The model was developed from the unsteady Navier-Stokes momentum, energy, and continuity equations and was linearized using small perturbations. The energy equation was decoupled from momentum and continuity assuming a polytropic flow process. Rarefied flow conditions were accounted for using a slip flow boundary condition at the tubing wall. The equations were radially averaged and solved assuming gas properties remain constant along a small tubing element. This fundamental solution was used as a building block for arbitrary geometries where fluid properties may also vary longitudinally in the tube. The problem was solved recursively starting at the transducer and working upstream in the tube. Dynamic frequency response tests were performed for continuum flow conditions in the presence of temperature gradients. These tests validated the recursive formulation of the model. Model steady-state behavior was analyzed using the final value theorem. Tests were performed for rarefied flow conditions and compared to the model steady-state response to evaluate the regime of applicability. Model comparisons were excellent for Knudsen numbers up to 0.6. Beyond this point, molecular affects caused model analyses to become inaccurate.
The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity via the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is necessary to complete the thermodynamic cycle for this conversion process. A unique sodium capillary pump for the Na-TEC is proposed, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > 90o) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Thus, the curvature created at this non-wetting condensation interface supplies a directed force upon the liquid sodium that effectively “pushes” it towards a high pressure region, whereas a traditional capillary wick “pulls” the liquid. Porous structures made of stainless steel 316 are commercially available, and this material is non-wetting to sodium at the relevant temperature range of the Na-TEC condenser (500K – 673K). An experimental set-up is used to measure several interfacial and transport properties of the condensed sodium within this porous structure. These properties include the temperature dependent Laplace pressure generated at the phase change interface and the permeability of the porous structure. Liquid sodium is in contact with the porous structure and is progressively pressurized with argon gas until the sodium “breaks through” and the liquid begins to flow. This break-through pressure is determined when electrical contact is established between the flowing liquid metal and a set of electrodes cemented along the flow path. The velocity of the flowing sodium can also be measured with these electrodes, and the permeability is then determined by fitting velocity data to the classical Darcy law. These interfacial properties are then applied to a conjugate heat transfer model, which treats the coupled momentum and thermal transport processes within the non-wetting porous structure as sodium vapor is condensed. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for non-isothermal, compressible sodium vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is considered for situations where there is a substantial presence of non-condensable argon inside the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. Finally, the main design features of an experimental set-up used to demonstrate this capillary pumping is described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. A pump curve used to gauge the performance of this pumping mechanism is also created.
In a sodium thermal electrochemical converter (Na-TEC), the transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is necessary to complete the thermodynamic cycle. This pumping can be typically achieved via capillary action. A unique capillary pump is explored in this work, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > π/2) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Conjugate heat transfer techniques are required to model the coupled momentum and thermal transport processes within this porous structure. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is applied for the non-isothermal, compressible vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). The permeability of the porous structure is modeled using the Blaze-Kozeny expression, with an additional factor that accounts for this change in Kn. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented. The design of an experiment to validate the results from this modeling effort is also described. The main design features of the experimental set-up are presented, and the method used to measure the low sodium mass flowrates is discussed. Initial experimental results demonstrating sodium pumping for a range of temperatures (850K – 1150K) will be presented and compared against the model predictions. A number of challenges affecting the successful completion of this experiment will also be discussed. Primarily, the sodium vapor must be superheated to prevent condensation anywhere except within the porous structure. Other challenges include the requirement to keep the condensation interface above ~ 675K to prevent transition to a wetting regime, and the control of the transient heating rate so that vapor flows slower than the quasi steady-state mass flowrate, which would otherwise lead to a flooding condition that prevents pumping. Specific strategies used to address these challenges are presented, and the experimental procedures used to gather data are discussed.
The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is required to complete the thermodynamic cycle of a sodium thermal electrochemical converter (Na-TEC). A unique capillary pump is explored in this work, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > pi/2) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Conjugate heat transfer techniques are used to model the coupled momentum and thermal transport processes within this non-wetting porous structure. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for the non-isothermal, compressible vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is also considered for situations where there is a substantial presence of non-condensable argon in the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. The main design features of an experimental set-up used to demonstrate this capillary pumping is also described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. Finally, several of the challenges with this experiment will be discussed, and specific strategies used to address these are presented.
Gas flows have been studied quantitatively for more than a hundred years and have relevance in modern fields such as the control of gas inputs to processes, the measurement of leak rates and the separation of gaseous species. Cha and McCoy have derived a convenient formula for the flow of an ideal gas applicable across a wide range of Knudsen numbers (Kn) that approaches the Navier–Stokes equations at small Kn and the Smoluchowski extension of the Knudsen flow equation at large Kn. Smoluchowski’s result relies on the Maxwell definition of the tangential momentum accommodation coefficient α, recently challenged by Arya et al. We measure the flow rate of nitrogen gas in a smooth walled silica tube across a wide range of Knudsen numbers from 0.0048 to 12.4583. We find that the nitrogen flow obeys the Cha and McCoy equation with a large value of α, unlike carbon nanotubes which show flows consistent with a small value of α. Silica capillaries are therefore not atomically smooth. The flow at small Kn has α=0.91 and at large Kn has α close to one, consistent with the redefinition of accommodation coefficient by Arya et al., which also resolves a problem in the literature where there are many observations of α of less than one at small Kn and many equal to one at large Kn. Silica capillaries are an excellent choice for an accurate flow control system. - Highlights: • First experimental study on flow rate across all flow regimes in a well-defined microtube. • Extend Cha and McCoy theory for molecular flow regime. • Demonstrate the Maxwell accommodation coefficient is different in the slip and molecular flow regimes.
In an earlier paper we employed an analogy between surface-to-surface radiation and free-molecular flow to model Knudsen flow through tubes and onto planes. In the current paper we extend the analogy between thermal radiation and molecular flow to model the flow of a gas in a 2D channel across all regimes of rarefaction. To accomplish this, we break down the problem of gaseous flow into three sub-problems (self-diffusion, mass-motion and generation of pressure gradient) and use the finite volume method for modeling radiation through participating media to model the transport in each sub-problem as a radiation problem. We first model molecular self-diffusion in the stationary gas by modeling the transport of the molecular number density through the gas starting from the analytical asymptote for free-molecular flow to the kinetic theory limit of gaseous self-diffusion. We then model the transport of momentum through the gas at unit pressure gradient to predict Poiseuille flow and slip flow in the 2D gas. Lastly, we predict the generation of pressure gradient within the gas due to molecular collisions by modeling the transport of the forces generated due to collisions per unit volume of gas. We then proceed to combine the three radiation problems to predict flow of the gas over the entire Knudsen number regime from free-molecular to transition to continuum flow and successfully capture the Knudsen minimum at Kn ∼ 1.
The influence of the anisotropy of elastic energy on the phonon propagation and phonon transport in single crystal nanofilms with different types of anisotropy of elastic energy in a Knudsen flow of a phonon gas is studied. The angular distribution of phonon mean free paths in the planes of the films and in their cross section is analyzed. The physical reasons leading to the dependence of the thermal conductivity on the orientation of the film planes and the directions of the heat flux relative to the crystal axes are studied. An analysis of the effect of focusing on the phonon propagation made it possible to explain the qualitative difference between the anisotropy of phonon mean free paths in films of cubic nanocrystals of various types having different orientations of the planes.
Impact pressure probe response characteristics in free-molecular and continuum flows with transition Knudsen numbers
Hybrid simulation frameworks combining Computational Fluid Dynamics (CFD) and Direct Simulation Monte Carlo (DSMC) are frequently employed to efficiently perform high-fidelity solutions of environments containing combined continuum/rarified flow. The use of DSMC, a stochastic, particle-based method, is necessary for high-Knudsen flow where continuum-based assumptions governing CFD break down. However, the DSMC methodology is generally very computationally inefficient to model the continuum regime. In a CFD/DSMC hybrid approach, obtaining an accurate, high-fidelity solution hinges on the consistent treatment of transport properties and the used thermo-chemical models employed within the two solvers. In principle, in regions where CFD and DSMC are both employed, the same gas mixture under the same conditions should have the same properties, regardless of simulation type. Observed differences should be due to non-equilibrium processes, rather than differences in physical models. While the transport models governing CFD and DSMC simulations are starkly different, they can effectively be linked via their use of reduced Chapman-Enskog collision integrals. In CFD, these integrals are typically stored as fitted polynomial expressions and used to directly compute gas transport properties via mixing rules or the full Chapman-Enskog formulation. In DSMC, they can be used to derive the collision parameters needed for the phenomenological collision cross-section models that govern particle interactions, via a Nelder-Mead optimization scheme. The goal of this work is to provide a unified DSMC transport database encompassing the vast majority of known gas species encountered during atmospheric entry, on Earth or any other Solar body. This goal is largely possible due to recently performed ab-initio quantum chemistry calculations. Combined with other high-fidelity literature sources, the planned database will consist of collision integral data for over 200 neutral and ionized species and over 17000 binary collisions. From these collision integrals, Nelder-Mead optimization is used to compute Variable Soft Sphere (VSS) collision model parameters for DSMC, fitted from 300 K to 20000 K. Initial comparisons of transport properties of relevant equilibrium gas mixtures show great agreement between CFD and DSMC-derived results. The completed database will be able to be readily applied to model binary collisions of any gas mixture containing the included species over the specified temperature range, making it a valuable tool for future planetary probe modeling efforts. An example is shown below. Equilibrium mixture transport properties for a 19-species Titan atmospheric model [4] are computed using both fitted VSS parameters and the original CFD collision integral values. Deviations in computed properties between the two approaches is less than 5% for the entire temperature range.
Impact pressure probe response characteristics in high speed flows with transition Knudsen numbers
Hybrid simulation frameworks combining Computational Fluid Dynamics (CFD) and Direct Simulation Monte Carlo (DSMC) are frequently employed to efficiently perform high-fidelity simulations of environments consisting of both continuum and rarified flow. DSMC is a stochastic, particle-based method which solves the fundamental Boltzmann equation and is therefore necessary for high-Knudsen flow where continuum-based assumptions governing CFD break down. However, the DSMC methodology is generally computationally inefficient to model the continuum regime. In a CFD/DSMC hybrid approach, obtaining an accurate, high-fidelity solution hinges on the consistent treatment of transport properties and the thermo-chemical models employed within the two solvers. In principle, in regions where CFD and DSMC are both employed, the same gas mixture under the same conditions should have the same properties, regardless of simulation type. Observed differences should be due to non-equilibrium processes, rather than differences in physical models. The goal of this work is to provide a comprehensive DSMC transport database encompassing the vast majority of known gas species encountered during Earth or other planetary atmospheric entry. This goal is largely possible due to recently performed ab initio quantum chemistry calculations. Combined with other high-fidelity data, the planned database will consist of collision integral data for over 200 neutral and ionized species and over 20000 binary collisions. From these collision integrals, Nelder-Mead optimization is used to compute collision-specific Variable Soft Sphere (VSS) collision model parameters, fitted from 300 K to 20000 K. Initial comparisons of transport properties of relevant equilibrium gas mixtures show great agreement between CFD and DSMC-derived results. The completed database can be readily applied to model binary collisions of any gas mixture containing the included species over the specified temperature range, making it a valuable tool for future planetary probe modeling efforts. An example is shown below in Fig. 1. Equilibrium mixture transport properties for a 35-species mixture composed originally of 10% air and 90% pyrolysis species of a carbon-phenolic ablator material [4] are computed using both fitted VSS Parameters and the original CFD collision integral values. Deviations in computed properties between the two approaches are less than 5% for the entire temperature range.
We report the first characterization study of commercial prototype carbon nanotube (CNT) membranes consisting of sub–1.27-nm-diameter CNTs traversing a large-area nonporous polysulfone film. The membranes show rejection of NaCl and MgSO 4 at higher ionic strengths than have previously been reported in CNT membranes, and specific size selectivity for analytes with diameters below 1.24 nm. The CNTs used in the membranes were arc discharge nanotubes with inner diameters of 0.67 to 1.27 nm. Water flow through the membranes was 1000 times higher than predicted by Hagen-Poiseuille flow, in agreement with previous CNT membrane studies. Ideal gas selectivity was found to deviate significantly from that predicted by both viscous and Knudsen flow, suggesting that surface diffusion effects may begin to dominate gas selectivity at this size scale.