Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

Investigation of magnetic noise from conductive shields in the 10–300 kHz frequency range

Here we present experimental and theoretical investigations of magnetic noise originating from radio-frequency (RF) conductive shields of flat geometry in the inductance-dominated impedance regime below 300 kHz. The measurement is based on a Q-factor determination of a coil that provides a sufficient sensitivity, placed at the position where the shield magnetic noise is measured. The theory is based on calculations of magnetic field and inductance of one or a few flat rings that emulate a conductive shield. The theoretical model is found to be in close agreement with experimental data. It can be used to predict the magnetic noise of a conductive shield with different thicknesses, conductivities, and temperatures at different distances for a wide range of frequencies. Although the model can be generalized for a more arbitrary shield geometry, in its presented form, it can be applied to the magnetic noise predictions when the shield surface curvature is not large. One important conclusion is that the RF conductive shield can generate the magnetic noise much lower than femtotesla, and, thus, it can be used in many precision experiments targeting minute high-frequency magnetic signals, such as detection of magnetic resonance imaging and nuclear quadrupole resonance signals and search for axion dark matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fault-tolerant optical interconnects for neutral-atom arrays

We analyze the use of photonic links to enable large-scale fault-tolerant connectivity of locally error-corrected modules based on neutral atom arrays. Our approach makes use of recent theoretical results showing the robustness of surface codes to boundary noise and combines recent experimental advances in atom-array quantum computing with logical qubits with optical quantum networking techniques. We find the conditions for fault tolerance can be achieved with local two-qubit Rydberg gate and nonlocal Bell-pair errors below 1% and 10%, respectively, without requiring distillation or space-time overheads. Realizing the interconnects with a lens, a single optical cavity, or an array of cavities enables—with sufficient multiplexing—a Bell-pair generation rate in the 1–50 MHz range. When directly interfacing logical qubits, this rate translates to error-correction cycles in the 25–2000 kHz range, satisfying all requirements for fault tolerance and in the upper range fast enough for 100 kHz logical clock cycles. Published by the American Physical Society 2025

Sinclair, Josiah (ORCID:0000000215238295)↗

Pedestal formation via different trajectories in the stability space in response to the timing scan of neutral beam heating in DIII-D

The frequency of type-I ELMs decreases as the initiation of the neutral beam injection (NBI) heating is delayed with respect to the time when plasma current (I p ) reaches flat-top in the ITER Baseline Scenario discharges in DIII-D. Henceforth, the time gap between the NBI initiation and I p flat-top will be referred to as “heating delay.” As the heating delay is modified, pedestal formation follows different trajectories in the edge current density–pedestal pressure gradient (j edge -∇p e ped ) space from the L-H transition toward the first ELM event. During the stationary phase after the first ELM, the ELM frequency (f ELM ) decreases by a factor of ~2 as the heating delay is increased. A longer pedestal recovery time in the inter-ELM period is observed for the low f ELM discharges as compared to the high f ELM discharges. Both low and high f ELM discharges show nearly identical profiles of electron density and temperature and have a similar MHD stability just before an ELM crash. However, a marked difference is observed in the magnetic spectrogram of the high and low f ELM discharges in response to the variation in the heating delay. The main difference is in the 200–400 kHz range of the magnetic spectra. A quasi-coherent mode (QCM) at 220 kHz and weaker broadband fluctuations are observed in the high f ELM discharges, while only strong broadband fluctuations are prevalent in the low f ELM discharges. ELM-synchronized analysis shows that the time evolution of these modes is different for the high and low f ELM discharges. The localization of both these modes is confirmed at the maximum gradient region of the pedestal. We hypothesize that these modes cause important pedestal transport and that the difference in the pedestal recovery of the high and low f ELM discharges is a result of the difference in transport driven by these modes, as they change with changes in the heating delay. It is demonstrated experimentally for the first time that discharges with similar pedestal parameters can carry the history of the heating delay into the stationary phase and that changes in turbulent-driven transport are a likely cause of changes in f ELM observed with variations of heating delay.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-temperature high-frequency dynamic magnetic susceptibility of classical spin-ice Dy 2 Ti 2 O 7

In this study, radio-frequency (14.6 MHz) AC magnetic susceptibility, , of Dy 2 Ti 2 O 7 was measured using self-oscillating tunnel-diode resonator. Measurements were made with the excitation AC field parallel to the superimposed DC magnetic field up to 5 T in a wide temperature range from 50 mK to 100 K. At 14.6 MHz, a known broad peak of from kHz—range audio-frequency measurements around 15 K for both [111] and [110] directions shifts to 45 K, continuing the Arrhenius activated behavior with the same activation energy barrier of E a ≈ 230 K. Magnetic field dependence of along [111] reproduces previously reported low-temperature two-in-two-out to three-in-one-out spin configuration transition at about 1 T, and an intermediate phase between 1 and 1.5 T. The boundaries of the intermediate phase show reasonable overlap with the literature data and connect at a critical endpoint of the first order transition line, suggesting that these features are frequency independent. An unusual upturn of the magnetic susceptibility at T → 0 was observed in magnetic fields between 1.5 T and 2 T for both magnetic field directions, before fully polarized configuration sets in above 2 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robust identification of multiple-input single-output system response for efficient pickup noise removal from tokamak diagnostics

We report electromagnetic pickup noise in the tokamak environment imposes an imminent challenge for measuring weak diagnostic photocurrents in the nA range. The diagnostic signal can be contaminated by an unknown mixture of crosstalk signals from coils powered by currents in the kA range. To address this issue, an algorithm for robust identification of linear multi-input single-output (MISO) systems has been developed. The MISO model describes the dynamic relationship between measured signals from power sources and observed signals in the diagnostic and allows for a precise subtraction of the noise component. The proposed method was tested on experimental diagnostic data from the DIII-D tokamak, and it has reduced noise by up to 20 dB in the 1–20 kHz range.

47 OTHER INSTRUMENTATION↗

Wet chemistry-synthesized Fe/mixed ferrite soft magnetic composites for high-frequency power conversion

State-of-the-art soft magnetic (SM) alloy systems such as electrical steels and permalloys exhibit large eddy current losses at high-frequency (kHz range and above), limiting their application in fast switching devices. Eddy current losses can be reduced for metallic alloys through a decrease in characteristic length scale or embedding them in an insulation layer. This work proposes the development of fine-scale core materials consisting of metallic SM nano/microparticles with magnetic, inorganic insulation layers, and their synthesis using a wet chemistry-based, scalable method for high frequency and high-power applications. More specifically, a magnetic ferrite coating (Ni 0.5-x Mn x Zn 0.5 Fe 2 O 4 , x = 0.0–0.5) was applied via deposition of ferrite powder produced using a “wet chemistry-based” co-precipitation method; the ferrite was distributed through the Fe micropowder via either ball milling or ultrasonic mixing. Powder cores were prepared by compaction of the synthesized composites. Relative magnetic permeability and core loss were measured at excitation frequencies to 200 kHz. A core loss of 127 kW/m 3 was measured at excitation frequency of 100 kHz and magnetization of 0.02 T. This value improves on the 199.3 kW/m 3 reported in literature at identical excitation conditions for a compact formed from a composite comprising Fe microparticles coated with low-permeability Ni 0.5 Zn 0.5 Fe 2 O 4 . Ultrasonic mixing resulted in slightly lower core loss than ball milling, possibly because ball milling causes loss-increasing deformation of the Fe micropowder. XRD and SEM were used to observe composite composition and core cross-section microstructure.

36 MATERIALS SCIENCE↗

Two-temperature effects in Hall-MHD simulations of the HIT-SI experiment

A two-temperature Hall-magnetohydrodynamic (Hall-MHD) model, which evolves the electron and ion temperatures separately, is implemented in the PSI-Tet 3D MHD code and used to model plasma dynamics in the Helicity Injected Torus–Steady Inductive (HIT-SI) experiment. The two-temperature model is utilized for HIT-SI simulations in both the PSI-Tet and NIMROD codes at a number of different injector frequencies in the 14.5–68.5 kHz range. At all frequencies, the NIMROD two-temperature model results in increased toroidal current, lower chord-averaged density, higher average temperatures, outward radial shift of the current centroid, and axial symmetrization of the current centroid, relative to the single-temperature NIMROD simulations. The two-temperature PSI-Tet model illustrates similar trends, but at high frequency operation, it exhibits lower electron temperature, smaller toroidal current, and decreased axial symmetrization with respect to the single-temperature PSI-Tet model. With all models, average temperatures and toroidal currents increase with the injector frequency. Power balance and heat fluxes to the wall are calculated for the two-temperature PSI-Tet model and illustrate considerable viscous and compressive heating, particularly at high injector frequency. Parameter scans are also presented for artificial diffusivity, wall temperature, and density. Both artificial diffusivity and the density boundary condition significantly modify the plasma density profiles, leading to larger average temperatures, toroidal current, and relative density fluctuations at low densities. As a result, a low density simulation achieves sufficiently high current gain (G > 5) to generate significant volumes of closed flux lasting 1–2 injector periods.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MHD-blob correlations in NSTX

This paper describes a study of the cross-correlations between edge fluctuations as seen in the gas puff imaging (GPI) diagnostic and low frequency coherent magnetic fluctuations (“MHD”) in H-mode plasmas in NSTX. The main new result was that large blobs in the SOL were significantly correlated with MHD activity the 3-6 kHz range in 21 of the 223 shots examined. There were also many other shots in which fluctuations in the GPI signal level and its peak radius Rpeak were correlated with MHD activity, but without any significant correlation of the MHD with large blobs. The structure and motion of the MHD is compared with that of the correlated blobs, and some possible theoretical mechanisms for the MHD-blob correlation are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MHD-blob correlations in NSTX

This paper describes a study of the cross-correlations between edge fluctuations as seen in the gas puff imaging (GPI) diagnostic and low frequency coherent magnetic fluctuations (MHD) in H-mode plasmas in NSTX. The main new result was that large blobs in the SOL were significantly correlated with MHD activity the 3-6 kHz range in 21 of the 223 shots examined. There were also many other shots in which fluctuations in the GPI signal level and its peak radius Rpeak were correlated with MHD activity, but without any significant correlation of the MHD with large blobs. The structure and motion of the MHD is compared with that of the correlated blobs, and some possible theoretical mechanisms for the MHD-blob correlation are discussed.

blobs↗

Mu2e Tracker Electronics - Construction of a Straw Tracker

The Mu2e experiment, located at the Fermi National Accelerator Laboratory (FNAL), also known as Fermilab, in Batavia, Illinois, is an in-progress particle physics experiment aiming to detect Charged Lepton Flavor Violation (CLFV) via the $\mu^-Al\rightarrow e^-Al$ interaction, a Beyond the Standard Model (BSM) process. One of the sections of the Mu2e experiment is the Tracker, which aims to identify the signal and reject the background while the experiment is running. A total of 20,736 Calibration (CAL) and High-Voltage (HV) preamplifiers (preamps) are being installed within 36 planes that make up the Tracker. During this process, MHz oscillations were discovered on the CAL preamps, obscuring desired signal detection in the \~kHz range. To solve this issue, copper clips are installed onto the CALs to remove the MHz oscillations. The installation of electronics into the Tracker will be discussed in depth.

Lynch, Alec Michael [UC, Berkeley; Fermilab]↗

Aerodynamic-whistles-based ultrasonic tone generators for bat deterrence

Novel ultrasonic bat deterrents based on aerodynamic whistles are proposed and investigated experimentally and numerically for their ability to generate ultrasound. The baseline deterrent, a single-whistle design inspired by Beeken [“Fluid ultrasonic generator,” U.S. patent 3,432,804 (1969)], is examined first. It consists of two resonating cavities/chambers. The whistle is “powered” by a regulated high-pressure air supply, and the performance of the whistle is examined for a range of supply pressures. Far-field acoustic measurements in the 20 Hz–50 kHz frequency range are made in an anechoic chamber. The noise measurements are supplemented with two- and three-dimensional unsteady Reynolds-averaged Navier–Stokes (uRANS) simulations to investigate the mechanisms of ultrasound generation. The Ffowcs Williams–Hawkings acoustic analogy is used with the three-dimensional uRANS results to predict the far-field radiation. The far-field acoustic predictions are in good agreement with the measurements in the anechoic chamber. The peak frequency (fundamental) of the radiated ultrasound of the baseline deterrent is approximately 23 kHz. Harmonics and a sub-harmonic of the fundamental tone are also observed. The numerical simulations show that the two resonating chambers of the baseline deterrent operate out-of-phase and Helmholtz resonance determines the whistling frequency over the range of supply air pressure considered. A six-whistle deterrent targeting a broad spectral coverage in the 20–50 kHz frequency range is designed, fabricated, and tested in the anechoic chamber. Each whistle in the deterrent is obtained by geometrically scaling the baseline whistle. Measurements show that the six-whistle ultrasound deterrent generates ultrasound with six dominant peaks in the designed frequency range when the supply air pressure exceeds 5 psig. The proposed ultrasound devices can be used for a variety of purposes including bat deterrence at wind turbines.

42 ENGINEERING↗

The Global Magneto-ionic Medium Survey: A Faraday Depth Survey of the Northern Sky Covering 1280–1750 MHz

The Galactic interstellar medium hosts a significant magnetic field, which can be probed through the synchrotron emission produced from its interaction with relativistic electrons. Linearly polarized synchrotron emission is generated throughout the Galaxy and, at longer wavelengths, modified along nearly every path by Faraday rotation in the intervening magneto-ionic medium. Full characterization of the polarized emission requires wideband observations with many frequency channels. We have surveyed polarized radio emission from the Northern sky over the range 1280–1750 MHz, with channel width 236.8 kHz, using the John A. Galt Telescope (diameter 25.6 m) at the Dominion Radio Astrophysical Observatory, as part of the Global Magneto-Ionic Medium Survey. The survey covered 72% of the sky, decl. −30° to +87° at all R.A. The intensity scale was absolutely calibrated, based on the flux density and spectral index of Cygnus A. Polarization angle was calibrated using the extended polarized emission of the Fan Region. Data are presented as brightness temperatures with angular resolution 40′. Sensitivity in Stokes Q and U is 45 mK rms in a 1.18 MHz band. We have applied rotation measure synthesis to the data to obtain a Faraday depth cube of resolution 150 rad m{sup −2} and sensitivity 3 mK rms of polarized intensity. Features in Faraday depth up to a width of 110 rad m{sup −2} are represented. The maximum detectable Faraday depth is ±2 × 10{sup 4} rad m{sup −2}. The survey data are available at the Canadian Astronomy Data Centre.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optomechanical interaction in fibre lasers with micro-optomechanical resonance structures

We report the results of studies of fibre lasers with passive modulators based on light-excited micro-optomechanical resonance structures (micro-oscillators). It is shown that in fibre lasers based on active fibres doped with rare-earth elements (Er, Er/Yb, Yb, Nd), the optomechanical interaction of laser radiation with micro-oscillators of various types (fibre-optic, microvolume) leads to self-oscillations of the characteristics of laser radiation at frequencies of relaxation oscillations and intermode beats synchronised with the frequencies of elastic eigenoscillations of micro-oscillators. It is found that in an ultra-long erbium – ytterbium fibre laser with a nonlinear mirror based on a microcantilever, laser photothermal excitation of the second mode of elastic transverse oscillations of the microcantilever makes it possible to perform passive mode locking exclusively due to Q-switching of the laser cavity. Pulsed lasing with a controlled repetition rate (∼76 kHz), a pulse duration of 2 – 5 μs and an output energy of 0.1 μJ per pulse is implemented. Based on a simplified physical model of the indicated fibre lasers with micro-oscillators, we have developed an approximate mathematical model describing the regimes of passive mode locking of fibre lasers with micro-oscillators that play the role of mirrors with a nonlinear reflection coefficient in the laser cavity. The prospects for the development and application of the considered laser systems are discussed. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phasing of seven-channel fibre laser radiation with dynamic turbulent phase distortions using a stochastic parallel gradient algorithm at a bandwidth of 450 kHz

We have demonstrated an experimental setup for the coherent phasing of a seven-channel fibre laser system ( λ = 1064 nm) in a scheme comprising a master oscillator and a set of parallel amplifiers with lithium niobate-based fibre-optic phase modulators. Using a stochastic parallel gradient algorithm, an instrumental phase modulator control unit ensures a bandwidth of the system up to 450 kHz. The effectiveness of phasing of light transmitted through a turbulent medium with a characteristic time scale τ{sub turb} has been studied experimentally as a function of phasing time τ{sub ph}. The results demonstrate that the average Strehl ratio begins to rise at τ{sub turb}/τ{sub ph} ⩾ 2 and that the effectiveness of compensation for dynamic phase distortions in the beam propagation path rises sharply at τ{sub turb}/τ{sub ph} ≈ 20. For τ{sub turb}/τ{sub ph} ⩾ 30 – 40, the average Strehl ratio remains constant at the level reached. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ytterbium laser system for studying parametric amplification of femtosecond pulses with a centre wavelength of ∼2 μm

A laser system is developed with an optical synchronisation of a femtosecond signal with a pump channel. The signal of a driving ytterbium fibre laser with a 60 MHz repetition rate of stretched femtosecond pulses is amplified in energy from several nanojoules to 0.4 mJ at a pulse repetition rate of 3 kHz in a wideband amplifier and then is compressed in time to 250 fs. The obtained radiation is used for generating femtosecond laser pulses with a centre wavelength of ∼2 μm, pulse energy of above 20 μJ, duration of several field oscillations, and phase stabilisation between the electromagnetic field and envelope. The other pulse of the driving fibre laser provides optical synchronisation and a minimal time delay and is directed to a regenerative Yb : YAG disk amplifier for amplification to an energy of 4 mJ at a pulse repetition rate of 3 kHz and duration of 20 ps. A multipass disk amplifier is developed for further increasing the energy of pump chirped pulses to an energy of 70 mJ at a pulse repetition rate of 10 Hz and duration of 400 ps for studying parametric amplification under sub-nanosecond pumping. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modelling of the laser amplification process with allowance for the effect of the temperature distribution in an Yb : YAG gain element on the thermophysical and lasing characteristics of the medium

A time-dependent three-dimensional model for the laser amplification process has been constructed with allowance for the effect of the temperature distribution on the thermophysical and lasing characteristics of gain media. We have performed numerical modelling of the laser amplification process in the gain elements of a two-stage subjoule-level cryogenic laser amplifier operating at a pulse repetition rate of up to 1 kHz. It has been shown that taking into account the temperature distribution is of critical importance in calculation of cryogenically cooled laser amplifiers pumped with high-power diodes. We have found optimal diode pump parameters at which the maximum achievable pulse energy at the amplifier output can reach 300 and 570 mJ at pulse repetition rates of 1000 and 500 Hz, respectively. (extreme light fields and their interaction with matter)

42 ENGINEERING↗