Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “KHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range

In several low-field Nuclear Magnetic Resonance (LF-NMR) and surface nuclear magnetic resonance applications, i.e., in the frequency range of kHz, high sensitivity magnetic field detectors are needed. Usually, low-T{sub c} superconducting quantum interference devices (SQUIDs) with a high field sensitivity of about 1 fT/Hz{sup 1/2} are employed as detectors. Considering the flux trapping and operational difficulties associated with low-T{sub c} SQUIDs, we designed and fabricated liquid-nitrogen-cooled Cu coils for NMR detection in the kHz range. A cooled coil system consisting of a 9-cm diameter Cu coil and a low noise preamplifier was systematically investigated and reached a sensitivity of 2 fT/Hz{sup 1/2} at 77 K, which is 3 times better compared to the sensitivity at 300 K. A Q-switch circuit as an essential element for damping the ringing effects of the pickup coil was developed to acquire free induction decay signals of a water sample with minimum loss of signal. Our studies demonstrate that cooled Cu coils, if designed properly, can provide a comparable sensitivity to low-T{sub c} SQUIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending accurate spectral induced polarization measurements into the kHz range: modelling and removal of errors from interactions between the parasitic capacitive coupling and the sample holder

SUMMARY Spectral induced polarization (SIP), describing the measurement of the frequency domain electrical impedance magnitude and phase of porous materials, has been widely used to characterize subsurface hydrological/biogeochemical properties and processes. SIP data collected at frequencies higher than 100 Hz are expected to describe the polarization of small particles providing insights into the physicochemical properties of clays, nanoparticles and microorganisms. However, the phase measurements at these high frequencies are often contaminated by errors due to the parasitic capacitive coupling of the SIP instrument, especially for lower conductivity samples. We developed a model showing the measured phase is the sum of the true sample phase and an error term ωCinZx, where ω is the angular frequency; Cin is the instrument input capacitance and Zx is a measurable impedance function related to the sample holder properties and the reference resistor. Based on this model, a new phase correction method is proposed that results in highly accurate SIP data up to 20 kHz as well as the determination of Cin. We tested the correction method using electric circuits, NaCl fluids and three unconsolidated samples (sand, sand-clay and sand-pyrite mixtures). The corrected phase for the circuit and NaCl fluid experiments showed excellent agreement with the theoretical phase response across the studied frequency range (errors <1 mrad). For unconsolidated samples, removal of errors results in phase spectra more consistent with expected polarization mechanisms, as based on phase peaks recorded for small pyrite and clay particles at high frequencies. These phase peaks could not be identified in the uncorrected data. Our approach can substantially enhance the value of the SIP method for the characterization of fine-grained sediments and rocks.

58 GEOSCIENCES↗

Modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz

A sounding rocket-borne electron detector of high time resolution is used to search for modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz and energy range 5-7 keV. Data were telemetered to ground via a 93-kHz subcarrier. A cross-correlation analysis of the data collected indicates low-level modulation near the detection threshold of the instrument. Two U-1 events are observed which are interpreted as indications of modulation. The two modulation events occur during a period of increasing flux for a region marking the boundary between two current sheets detected by the payload magnetometer. The strongest argument against interference contamination is the lack of any observable modulation at times other than those mentioned in the study.

Spiger, R. J.↗

High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range

Here, optically pumped magnetometers (OPM) can be used in various applications, from magnetoencephalography to magnetic resonance imaging and nuclear quadrupole resonance (NQR). OPMs provide high sensitivity and have the significant advantage of non-cryogenic operation. To date, many magnetometers have been demonstrated with sensitivity close to 1 fT, but most devices are not commercialized. Most recently, QuSpin developed a model of OPM that is low cost, high sensitivity, and convenient for users, which operates in a single-beam configuration. Here we developed a theory of single-beam (or parallel two-beam) magnetometers and showed that it is possible to achieve good sensitivity beyond their usual frequency range by tuning the magnetic field. Experimentally we have tested and optimized a QuSpin OPM for operation in the frequency range from DC to 1.7 kHz, and found that the performance was only slightly inferior despite the expected decrease due to deviation from the spin-exchange relaxation-free regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

Investigation of magnetic noise from conductive shields in the 10–300 kHz frequency range

Here we present experimental and theoretical investigations of magnetic noise originating from radio-frequency (RF) conductive shields of flat geometry in the inductance-dominated impedance regime below 300 kHz. The measurement is based on a Q-factor determination of a coil that provides a sufficient sensitivity, placed at the position where the shield magnetic noise is measured. The theory is based on calculations of magnetic field and inductance of one or a few flat rings that emulate a conductive shield. The theoretical model is found to be in close agreement with experimental data. It can be used to predict the magnetic noise of a conductive shield with different thicknesses, conductivities, and temperatures at different distances for a wide range of frequencies. Although the model can be generalized for a more arbitrary shield geometry, in its presented form, it can be applied to the magnetic noise predictions when the shield surface curvature is not large. One important conclusion is that the RF conductive shield can generate the magnetic noise much lower than femtotesla, and, thus, it can be used in many precision experiments targeting minute high-frequency magnetic signals, such as detection of magnetic resonance imaging and nuclear quadrupole resonance signals and search for axion dark matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion resonances and ELF wave production by an electron beam injected into the ionosphere - ECHO 6

Two effects observed with electron antennas ejected from a sounding rocket launched into the ionosphere in March 1983 carrying electron beam guns are discussed. The sensor packages were ejected and travelled parallel to the vehicle trajectory. Electric potentials were measured between the single probes and a plasma diagnostic package while the gun injected electrons into the ionosphere in perpendicular and parallel 1 kHz directions. Signal pulses over the dc-1250 kHz range were detected. A kHz gun frequency caused a signal that decreased by two orders of magnitude between 45-90 m from the beam field line. However, the signal was detectable at 1 mV/m at 120 m, supporting earlier data that indicated that pulsed electron beams can cause ELF waves in space. Beam injection parallel to the magnetic field produced an 840 Hz resonance that could be quenched by activation of a transverse beam.

Winckler, J. R.↗

EMI characteristics of a potential control system

With the development and use of charged particle sources for controlling spacecraft potentials there is a need to better understand the effects of these systems on spacecraft operations. The emission of charged particles perturbs the spacecraft environment and signals are generated which may interfere with other vehicle functions. In particular, the generated signals are apt to interfere with detectors for observing waves that exist naturally in the space environment. Examples of this type of interference are presented from the SCATHA satellite during a period when the vehicle was highly charged. A plasma source on board the spacecraft succeeded in discharging the vehicle with each of four different operating modes. The VLF broadband receiver on SCATHA detected interference over the entire 0-5 kHz range of both the electric and magnetic field detectors during these charged particle emissions. This frequency range includes the 2 kHz electron gyrofrequency but is below the 9 kHz electron plasma frequency. The observations suggest that interference occurs through introduction of anomalous signals, and through suppression of background field measurements.

Donatelli, D. E.↗

Visible light absorbance enhanced by nitrogen embedded in the surface layer of Mn-doped sodium niobate crystals, detected by ultra violet - visible spectroscopy, x-ray photoelectron spectroscopy, and electric conductivity tests

Sodium niobate crystals doped with manganese ions, Na(NbMn)O{sub 3}, were annealed in a nitrogen N{sub 2} flow at 600, 670, and 930 K. It was verified that simultaneous doping with Mn ions and annealing in nitrogen enhanced the photocatalytic features of sodium niobate. The transmission in the ultraviolet-visible range was measured at room temperature. The absorbance edge is in the range from 3.4 to 2.3 eV. The optical band gap E{sub gap} = 1.2–1.3 eV was evaluated using the Tauc relation. Crystals annealed at 670 K and 930 K exhibited an additional shift of the absorption edge of ∼20–40 nm toward longer wavelengths. The optical energy gap narrowed as a result of the superimposed effect of Mn and N co-doping. The x-ray photoelectron spectroscopy test showed that N ions incorporated into the surface layer. The valence band consisted of O 2p states hybridized with Nb 4d, Mn 3d, and N 2s states. The disorder detected in the surroundings of Nb and O ions decreased due to annealing. The binding energy of oxygen ions situated within the surface layer was E{sub B} ≈ 531 eV. The other contributions were assigned to molecular contamination. The contribution centered at 535.5 eV vanished after annealing at 600 K and 670 K. The contribution centered at 534 eV vanished after annealing at 930 K. The N{sub 2} annealing partly removed carbonates from the surfaces of the samples. In the 480–950 K range, the electric conductivity activation energy, E{sub a} = 0.7–1.2 eV, was comparable with the optical E{sub gap}. The electric permittivity showed dispersion in the 0.1–800 kHz range that corresponds to the occurrence of defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Response of silicon solar cell to pulsed laser illumination

The response of silicon solar cell(s) to pulsed laser illumination is discussed. The motivation was due to the interest of Earth to space/Moon power beaming applications. When this work began, it was not known if solar cells would respond to laser light with pulse lengths in the nanosecond range and a repetition frequency in the kHz range. This is because the laser pulse would be shorter than the minority carrier lifetime of silicon. A 20-nanosecond (ns) full width half max (FWHM) pulse from an aluminum-gallium/arsenide (Al-Ga-As) diode laser was used to illuminate silicon solar cells at a wavelength of 885 nanometers (nm). Using a high-speed digital oscilloscope, the response of the solar cells to individual pulses across various resistive loads was observed and recorded.

Willowby, D.↗

Sensitivity of the spherical gravitational wave detector MiniGRAIL operating at 5 K

We present the performances and the strain sensitivity of the first spherical gravitational wave detector equipped with a capacitive transducer and readout by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K. We characterized the detector performance in terms of thermal and electrical noise in the system output signal. We measured a peak strain sensitivity of 1.5x10{sup -20} Hz{sup -1/2} at 2942.9 Hz. A strain sensitivity of better than 5x10{sup -20} Hz{sup -1/2} has been obtained over a bandwidth of 30 Hz. We expect an improvement of more than 1 order of magnitude when the detector will operate at 50 mK. Our results represent the first step towards the development of an ultracryogenic omnidirectional detector sensitive to gravitational radiation in the 3 kHz range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Origin of Low Frequency Oscillations in Hall Thrusters

The breathing mode is a low frequency, longitudinal bulk instability observed in a majority of Hall thrusters. Its occurrence is accompanied by wide, regular discharge current oscillations in the 10-30 kHz range. A concise outline of the prevailing interpretations of this mode is provided, followed by an overview of a recently proposed theory. It is eventually shown that this ionization instability is not related to the motion of the ionization front but to an ionization predator-prey cycle, the former phenomenon being rather a consequence of the latter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AC electrokinetic manipulation of selenium nanoparticles for potential nanosensor applications

Highlights: ► Se nanoparticles were synthesized using a reverse-microemulsion process. ► AC osmotic fluid flow repulses the particles from electrode edges. ► Dielectrophoretic force attracts the particles to electrode edges. ► Dielectrophoresis electrode showed non-ohmic behavior. ► The device can potentially be used as a nanosensor. - Abstract: We report the AC electrokinetic behavior of selenium (Se) nanoparticles for electrical characterization and possible application as micro/nano devices. selenium Se nanoparticles were successfully synthesized using a reverse-microemulsion process and investigated structurally using X-ray diffraction and transmission electron microscope. Interdigitated castellated ITO and non-castellated platinum electrodes were employed for manipulation of suspended materials in the fluid. Using ITO electrodes at low frequency limits resulted in deposition of Se particles on electrode surface. When Se particles exposed to platinum electrodes in the 10 Hz–1 kHz range and V {sub p−p}> 8, AC osmotic fluid flow repulses the particles from electrode edges. However, in 10 kHz–10 MHz range and V {sub p−p}> 5, dielectrophoretic force attracts the particles to electrode edges. As the Se particle concentration increased, the trapped Se particles were aligned along the electric field line and bridged the electrode gap. The device was characterized and can potentially be useful in making micro/nano electronic devices.

36 MATERIALS SCIENCE↗

SQUIDs vs. Faraday coils for ultlra-low field nuclear magnetic resonance: experimental and simulation comparison

Nuclear magnetic resonance (NMR) methods are widely used in medicine, chemistry and industry. One application area is magnetic resonance imaging or MRI. Recently it has become possible to perform NMR and MRI in ultra-low field (ULF) regime that requires measurement field strengths only of the order of 1 Gauss. These techniques exploit the advantages offered by superconducting quantum interference devices or SQUIDs. Our group at LANL has built SQUID based MRI systems for brain imaging and for liquid explosives detection at airports security checkpoints. The requirement for liquid helium cooling limits potential applications of ULF MRI for liquid identification and security purposes. Our experimental comparative investigation shows that room temperature inductive magnetometers provide enough sensitivity in the 3-10 kHz range and can be used for fast liquid explosives detection based on ULF NMR/MRI technique. We describe an experimental and computer simulation comparison of the world's first multichannel SQUID based and Faraday coils based instruments that are capable of performing ULF MRI for liquids identification.

42 ENGINEERING↗

Vibration-induced electrical noise in a cryogen-free dilution refrigerator: Characterization, mitigation, and impact on qubit coherence

Cryogen-free low-temperature setups are becoming more prominent in experimental science due to their convenience and reliability, and concern about the increasing scarcity of helium as a natural resource. Despite not having any moving parts at the cold end, pulse tube cryocoolers introduce vibrations that can be detrimental to the experiments. We characterize the coupling of these vibrations to the electrical signal observed on cables installed in a cryogen-free dilution refrigerator. The dominant electrical noise is in the 5–10 kHz range and its magnitude is found to be strongly temperature dependent. We test the performance of different cables designed to diagnose and tackle the noise, and find triboelectrics to be the dominant mechanism coupling the vibrations to the electrical signal. Flattening a semi-rigid cable or jacketing a flexible cable in order to restrict movement within the cable, successfully reduces the noise level by over an order of magnitude. Furthermore, we characterize the effect of the pulse tube vibrations on an electron spin qubit device in this setup. Coherence measurements are used to map out the spectrum of the noise experienced by the qubit, revealing spectral components matching the spectral signature of the pulse tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide-band observations of LF hiss at Frobisher Bay /L = 14.6/

Temporal and spectral characteristics of LF hiss recorded at Frobisher Bay from October 30 to November 18, 1972 and from June 27, 1974 to June 26, 1975 using a wide-band (0-100 kHz) receiver are reported and discussed. The hiss occurs in bursts of about 1 to 30 min duration with a bandwidth of at least 30 kHz centered in the 20-30 kHz range. Its frequency may extend downward below 10 kHz with decreasing intensity and upward to 100 kHz with increasing intensity. There is a strong diurnal peak of occurrence centered on 21 hours LMT. Some events simultaneously recorded by a 30-MHz rapid response riometer directly follow LF hiss bursts. Apparently some electron precipitation events produce hiss bursts only, others produce hiss and then a riometer event as the precipitation flux hardens, and others, too hard to produce hiss, produce riometer events only. An examination of the present data together with previous results (Jorgensen et al., 1962; Laaspere et al., 1976) leads to the conclusion that the precipitating electrons causing ground-observed LF hiss are more energetic and have smaller pitch angles than most auroral hiss observed in the topside atmosphere with an electric dipole antenna.

Morgan, M. G.↗

The apparent spectral broadening of VLF transmitter signals during transionospheric propagation

ISIS 1 and 2 and ISEE 1 VLF/ELF electric field wave data indicate the existence of a novel phenomenon, in which initially narrow band upgoing signals from ground-based VLF transmitters undergo a significant spectral broadening as they propagate through the ionosphere and protonosphere, up to altitudes in the 600-3800 km range. For transmitter signals in the 10-20 kHz range, the spectral broadening can be as high as 10 percent of the input signal's nominal frequency. In many cases, the bandwidth of the spectrally broadened signals is a strong function of the electric dipole antenna orientation with respect to the local direction of the earth's magnetic field. The unusual dispersion in the components of the spectrally broadened pulses suggests that the spectral broadening may be due to a Doppler shift effect in which the initial signals scatter from irregularities in the F region and couple into quasi-electrostatic modes of short wave length.

Bell, T. F.↗