Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ion irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation of the mechanical and microstructural evolution of a Cu based bulk metallic glass during ion irradiation

Ion irradiation and annealing experiments were performed on Cu 60 Zr 20 Hf 10 Ti 10 bulk metallic glass (BMG) specimens to investigate their irradiation- and temperature-induced microstructural and mechanical property evolution. For the ion irradiations, samples were exposed to 9 MeV Ni 3+ ions to a midrange (~1.2 μm depth) dose of 10 displacements per atom (dpa) at temperatures ranging from room temperature to 360 °C (the corresponding peak dose at ~2.8 μm depth was ~25 dpa). Bulk X-ray diffraction (XRD) and transmission electron microscopy (TEM) characterization revealed that the alloy did not crystallize during irradiation up to 290 °C but did partially crystallize at 360 °C. XRD analysis revealed that the crystallization which occurred in the sample irradiated at 360 °C was caused by thermal effects instead of irradiation displacement damage. Subsequent Rietveld refinement analysis of the XRD measurements revealed the presence of two distinct crystal phases, namely a CuTiZr hexagonal structure belonging to the P63/mmc space group and a CuTi tetragonal structure belonging to the P4/mmm space group. Nanoindentation experiments revealed that no pronounced hardness changes occurred in the specimens irradiated at room temperature and 290°C, although significant hardening was observed in the sample irradiated at 360 °C. The significant increase in the hardness at 360°C was ascribed to thermally induced partial crystallization of the alloy instead of the ion irradiation. In general, the results of the nanoindentation experiments and XRD characterization suggest that although the Cu BMG exhibits good stability during irradiation at temperatures up to 290 °C it is not suitable for irradiation environments where the temperature is 360 °C for extended periods of time. The Lam and Chong extrapolation method, which has been used to study the indentation size effect (ISE) in amorphous alloys, was employed to quantify how irradiation and temperature affect this type of behavior in the BMG. However, the poor linear fitting of the indentation hardness data by this model indicate that a new ISE model is likely needed to quantify indentation hardening in BMGs.

36 MATERIALS SCIENCE↗

Review of Swift Heavy Ion Irradiation Effects in CeO2

Cerium dioxide (CeO2) exhibits complex behavior when irradiated with swift heavy ions. Modifications to this material originate from the production of atomic-scale defects, which accumulate and induce changes to the microstructure, chemistry, and material properties. As such, characterizing its radiation response requires a wide range of complementary characterization techniques to elucidate the defect formation and stability over multiple length scales, such as X-ray and neutron scattering, optical spectroscopy, and electron microscopy. In this article, recent experimental efforts are reviewed in order to holistically assess the current understanding and knowledge gaps regarding the underlying physical mechanisms that dictate the response of CeO2 and related materials to irradiation with swift heavy ions. The recent application of novel experimental techniques has provided additional insight into the structural and chemical behavior of irradiation-induced defects, from the local, atomic-scale arrangement to the long-range structure. However, future work must carefully account for the influence of experimental conditions, with respect to both sample properties (e.g., grain size and impurity content) and ion-beam parameters (e.g., ion mass and energy), to facilitate a more direct comparison of experimental results.

42 ENGINEERING↗

Local structure of Ni 80 X 20 (X: Cr, Mn, Pd) solid-solution alloys and its response to ion irradiation

In this work, the local structure of Ni 80 X 20 (X: Cr, Mn, Pd) solid-solution alloys was investigated with x-ray absorption and total scattering x-ray diffraction methods. Atomic pair distribution function (PDF) analysis indicated that the local lattice distortion is strongly relevant to the atomic size mismatch, and the local lattice distortion in Ni80Pd20 alloy is obviously larger than that in other solid-solution alloys. The bond length of different atomic pairs was derived from the fitting of extended x-ray absorption fine structure spectra. Quantitative analysis of the local bonding environment in Ni 80 Cr 20 during Ni ion irradiation suggested that Cr atoms tend to form clusters in Ni 80 Cr 20 with the increase of ion dose.

36 MATERIALS SCIENCE↗

From ground to excited electronic state dynamics of electron and ion irradiated graphene nanomaterials

Microscopes utilizing convergent electron and ion beams are emerging as powerful tools for both imaging and manipulating two-dimensional materials with atomic resolution, allowing the ultimate limits of nanofabrication to be realized. In this chapter, we detail the use of time-dependent electronic structure theory to determine the excited state properties and reactivity of functionalized graphene nanostructures. A time-dependent density functional theory treatment of electronic excitations of materials is presented, with specific emphasis on predicting the position-dependent electronic response of two-dimensional nanomaterials to electron beams. The method is demonstrated in a study highlighting the important role that electronic excitation can play in opening reaction pathways relevant to atomically precise defect manipulation in graphene. Finally, we provide some perspective on future development directions for methods of simulating nonequilibrium electronic and vibrational dynamics induced by electron/ion beams.

Lingerfelt, David↗

Development of a versatile, high-temperature, high-throughput ion irradiation system

We report ion irradiation has long been used as a surrogate for neutron irradiation experiments which are comparatively slower, more expensive, and often can leave materials activated and difficult to handle post-irradiation. However, with the growing use of combinatorial synthesis methods and high-throughput, automated characterization techniques, ion irradiation facilities will need to upgrade their capabilities to be able to accommodate these new material platforms. To address this challenge, a high-throughput ion irradiation system has been developed at the University of Wisconsin-Madison Ion Beam Laboratory (IBL). The system is capable of accommodating large sample arrays of arbitrary geometries and heat samples individually using an infrared laser to enable high-temperature, high-throughput ion irradiation while mitigating the risk of annealing the irradiation damage in nearby samples. To control stage motion, laser power, and beam current measurement, among other tasks, the program Chronos was developed which enables automated high-throughput irradiation experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contact-free reversible switching of improper ferroelectric domains by electron and ion irradiation

Focused ion beam (FIB) and scanning electron microscopy (SEM) are used to reversibly switch improper ferroelectric domains in the hexagonal manganite ErMnO 3 . Surface charging is achieved by local ion (positive charging) and electron (positive and negative charging) irradiation, which allows controlled polarization switching without the need for electrical contacts. Polarization cycling reveals that the domain walls tend to return to the equilibrium configuration obtained in the as-grown state. The response of sub-surface domains is studied by FIB cross-sectioning, enabling imaging in the direction perpendicular to the applied electric field. The results clarify how the polarization reversal in hexagonal manganites progresses at the level of domains, resolving both domain wall movements and the nucleation and growth of new domains. Our FIB-SEM based switching approach is applicable to all ferroelectrics where a sufficiently large electric field can be built up via surface charging, facilitating contact-free high-resolution studies of the domain and domain wall response to electric fields in 3D.

36 MATERIALS SCIENCE↗

Microstructural Simulation of Ion-Irradiated Natural Rocks and Minerals

This report details the contribution of Oak Ridge National Laboratory to the Nuclear Energy University Program (NEUP) project, "Rapid Characterization of Concrete Mineralogy using Multi-Scale Tools" led by the University of Illinois at Urbana-Champaign. To support the subsequent license renewal (SLR) of the US nuclear power plants (NPPs) fleet, the performance of concrete-forming aggregates against neutron irradiation needs to be assessed. Ion irradiation is proposed as a rapid, cost-effective surrogate method to full neutron irradiation testing. To complement the characterization of ion-irradiated rock specimens, ORNL has run finite-elements and fast-Fourier transform (FFT-based) simulations using the codes MARS and Microstructure-Oriented Scientific Analysis of Irradiated Concrete (MOSAIC). The main conclusion of this analysis is that the apparent post–ion-irradiation step-height underestimates the accumulated free radiation-induced volumetric expansion (RIVE) in the ion-implanted depth by about 15% at full amorphization and about 25% toward the beginning of the ion irradiation experiment. The discrepancy is explained by the fact that the step height is proportional to the sum of the RIVE (i.e., one third of the RIVE) and the irradiation-assisted plastic strains in the vertical direction (lower than two thirds of the RIVE). Because of the large lateral compressive stresses caused by the restraining effect of the unirradiated substrate, the stress field in the mineral grains and at the grain boundary (GB) in the ion-implanted layer is much different than the comparable stress field occurring during neutron irradiation. Hence, the mismatch RIVE causing cracks in the rock-forming minerals leads to different cracking patterns. Ion irradiation continues to be used as a rapid technique to assess the RIVE potential of rocks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MX precipitate behavior in an irradiated advanced Fe-9Cr steel: Self-ion irradiation effects on phase stability

In an effort to optimize Fe-9Cr reduced activation ferritic/martensitic (RAFM) steels and to inform the design and operation of fusion reactors, this work represents the first in a series of cohesive studies dedicated to the evolution of MX-TiC precipitates under accelerated single and dual ion irradiations. This study investigates CNA9, a simplified Fe-9Cr RAFM steel featuring initial MX-TiC precipitate densities of (2.3±0.3)×10²¹ m⁻³. This material was subjected to single self-ion irradiation at damage levels ranging from 1 to 100 displacements per atom (dpa) over a temperature range of 300 to 600°C, with a nominal dose rate of 7×10⁻⁴ dpa/s. Irradiation-induced coarsening was observed, as evidenced by statistically significant increases in mean diameter sizes, at 15 dpa at both 500°C and 600°C, whereas no coarsening was noted at 300°C or 400°C. Further, complete dissolution of precipitates occurred at damage levels of 50 and 100 dpa across the two temperatures tested (300°C and 500°C) while no significant changes were observed at any doses below 15 dpa at 500°C. Experimentally parameterized recoil resolution modeling suggests that the observed radiation stability of MX-TiC precipitates is intricately linked to diffusional changes of solutes resulting from the co-evolution of microstructural features within the experiments. The findings align with current theoretical perspectives on radiation-induced precipitate stability in complex alloys.

36 MATERIALS SCIENCE↗

A dual dynamic shutter system for accelerating ion irradiation sample throughput via lateral gas implantation gradients

Ion irradiation for material performance testing is limited due to its serial nature, which allows for only one value of the implantation (appm) versus dose (dpa) parameter space to be explored for each ion and experiment at a time. While ion irradiation can accelerate the process by up to three orders of magnitude compared to neutron irradiation experiments, the sample throughput for ion irradiation remains relatively low. To address these limitations, a novel capability has been developed at the Michigan Ion Beam Laboratory (MIBL), enabling for the creation of single- and two-dimensional lateral ion implantation gradients using recently installed motorized-controlled ion-beam shutters. This advancement can generate a wide scope of the two-dimensional (H+, He2+) implantation parameter space within a single sample. Integration of this new capability now allows for dual- and triple-ion beam experiments to be performed with full user control over not only the ion implantation depth, but also laterally across the sample by imposing ion implantation concentration gradients, thus providing researchers with a high-throughput means for material testing under various irradiation conditions. Furthermore, recent improvements in MIBL's microbeam ion-beam analysis (IBA) target station now allow for probing these concentration gradients in irradiated alloys with exceptional spatial resolution, down to 10 µm. These two approaches promise to significantly improve ion irradiation capabilities and increase the sample throughput by several orders of magnitude. The application of the shutter technique plus the subsequent microbeam characterization of the imposed implantation gradients are showcased by two proof-of-principle ion-irradiated experiments, one performed on single-crystal Si and the other on the fusion-candidate alloy F82H-IEA. These advancements mark a substantial leap in ion-beam technology, offering researchers a robust, high-throughput method to efficiently investigate candidate alloys with high technological readiness for both advanced fission and fusion reactor applications, in a time- and cost-effective manner.

36 - MATERIALS SCIENCE↗

In-situ TEM study of Kr ion irradiation tolerance of SiFeOC nanocomposite

Here, in this work, ion irradiation of polymer derived SiFeOC nanocomposite was carried out using 1.2 MeV Kr ions at room temperature and 600°C. The starting composite was composed of Fe 3 Si, SiC, SiOC, SiO 2 , and graphitic C. In-situ TEM investigations show uniform distribution of nano-crystalline Fe 3 Si and SiC phases in the amorphous SiOC matrix. During ion irradiation, the SiOC bulk microstructure and interfaces between Fe 3 Si or SiC crystallites and the SiOC matrix remain defect-free and demonstrate outstanding ion irradiation resistance. At room temperature, the crystalline domains are stable up to 2 dpa. At 600°C, Fe 3 Si crystallites are more stable than SiC; SiC crystallites are stable up to 4 dpa while the Fe 3 Si crystallites are stable up to 10 dpa. These crystallites also coalescence and amorphize simultaneously during ion irradiation. The exceptional tolerance to defect formation and irradiation of the SiFeOC nanocomposite provides important guidance to developing irradiation resistant fuels for advanced gas cooled reactors.

36 MATERIALS SCIENCE↗

Ion irradiation induced strain and structural changes in LiTaO 3 perovskite

LiTaO 3 crystals irradiated with 3 MeV and 1.162 GeV Au ions were studied by single crystal x-ray diffraction and Raman scattering measurements. The maximum lattice strains after 3 MeV Au ion irradiation to a fluence of 1.2 × 10 13 cm -2 were 1.2% and 0.6% along the c- and a-/b-axes, respectively. Two effects were observed in 1.162 GeV Au ion irradiated samples: (i) the (0006) and (1120) Bragg peaks were split into doublets, which suggested a subtle structural change due to slight modification of chemical composition; and (ii) the pre-damaged 1.2% lattice strain along the c-axis was relaxed to 0.9% after subsequent irradiation with 1.162 GeV Au ions, while relaxation along the a- or b-axis was not obvious. A distinct change in the Raman spectrum of the <0001> oriented LiTaO 3 crystals was observed after 1.162 GeV Au ion irradiation, but no obvious change was observed in the <1120> oriented samples or in 3 MeV Au ion irradiated samples. Strain and structural changes in crystalline LiTaO3, with or without pre-existing defects, upon ion irradiation are delineated in its responding to inelastic ionization and elastic nuclear collisions.

36 MATERIALS SCIENCE↗

Emulation of neutron-irradiated microstructure of austenitic 21Cr32Ni model alloy using dual-ion irradiation

Here, in this study, the capability of heavy-ion irradiation to emulate neutron irradiation was demonstrated on an austenitic 21Cr32Ni type ternary model alloy. The model alloy used in this study is chemically analogous but compositionally simpler than of alloy 800H, which is a candidate austenitic Ni alloy which has been proposed for use in Generation IV reactors. The microstructure of the 21Cr32Ni model alloy irradiated in the BOR-60 fast reactor to 17.1 dpa and 35 dpa at ~380°C was characterized using transmission electron microscopy (TEM). The 17.1 dpa BOR-60 irradiated microstructure was then compared with the microstructure of the same material developed under dual-ion (DI) irradiation using various He/dpa ratios between 0.1 and 16.6 appm He/dpa in the temperature range of 430°C-500°C. The results showed that both neutron and DI irradiation of 21Cr32Ni model alloy produced dislocations in the form of a dislocation network as well as {111}-type faulted dislocation loops, cavities, and radiation-induced Ni enrichment at radiation-induced sinks. When the dose and the He/dpa ratio were kept similar to those in neutron irradiation, DI irradiation of the 21Cr32Ni model alloy at 460°C resulted in over-nucleation of small cavities and in a high density of faulted dislocation loops compared to those observed in the fast-neutron irradiated alloy of the same heat irradiated at ~380°C. The optimal condition for reproducing the neutron-irradiated microstructure was DI irradiation at 460°C and 0.1 appm He/dpa. In that case, the faulted loop and cavity size distributions in the BOR-60 irradiated 21Cr32Ni model alloy samples closely matched with those measured in the DI irradiated 21Cr32Ni model alloy sample. The fact that the He/dpa is an order of magnitude smaller than the helium generation rate for fast neutron irradiation, stops over nucleation and allows for the development of a similar microstructure as for neutron irradiation.

21Cr32Ni model alloy↗