Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Internal cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Overall Cooling Effectiveness of Internally Cooled Additively Manufactured Blades

Power generation gas turbine blades must utilize highly effective cooling schemes to withstand moderate heat loads for long operating times. Prior work indicates that gas turbines in the 5-10 MW range primarily utilize internal cooling to prevent further increase of aerodynamic losses that result from film cooling, but few studies focus solely on internal cooling. In this study, three additively manufactured internal cooling designs were tested in the 50 percent span section of the National Experimental Turbine (NExT) blade: a baseline cooling design with pin-fin arrays and rib turbulators, a double wall design with impingement jets and serpentine channels, and an incremental impingement design. The designs were tested in a high-speed linear cascade at exit Reynolds numbers ranging from 700,000 to 1,400,000 at an exit Mach of 0.8. In addition, freestream turbulence and build angle effects on cooling performance were studied.

gas turbine blades

Overall Cooling Effectiveness of Internally Cooled Additively Manufactured Blades

By utilizing additive manufacturing, novel internal cooling designs can be quickly and cheaply vetted to enhance blade cooling performance. This improvement allows for higher turbine inlet temperatures while reducing the amount of coolant needed, therefore increasing the overall efficiency of small industrial gas turbines.

additive manufacturing

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING

Design and Flow Considerations of Additively Manufactured, Internal Cooling Geometries for Small Industrial Gas Turbines

Additive manufacturing is now a mainstream technology and can be utilized to rapidly develop and test turbine airfoil cooling networks. This paper reports on an ongoing effort to integrate advanced internal cooling architectures in a realistic blade profile for test in a high-speed cascade. Airfoil cooling schemes were developed using reduced order modeling and computer aided design. However, the additive manufacturing impacts on cooling channel flow performance were unknown. Test articles consisting of typical cooling features and networks were derived from the designs and flow proved to identify additive manufacturing impacts on performance and develop guidelines to mitigate these impacts.

additive manufacturing

Computational and Experimental Investigation of Discrete “W” Turbulators for sCO2 Turbine Internal Cooling

Direct-fired supercritical CO2 (sCO2 ) cycles are of particular interest for power generation due to the potential for higher thermal efficiencies with inherent CO2 capture. Direct fired sCO2 turbines must withstand high temperatures and the density of the working fluid is much higher than conventional Brayton cycles. Based on conventional Brayton cycle applications, internal serpentine cooling channels with ribbed turbulator strips are a common approach to achieve the required cooling, while minimizing coolant utilization. Most of the previous studies of coolant channel heat transfer enhancements have focused on serpentine channels using air as the cooling media at Reynold’s numbers typical of Brayton cycles. This paper investigates the Nusselt number augmentation of coolant channels with no features, ribbed turbulators, and discrete “W” turbulators with surface roughness effects included and CO2 as the coolant. The numerical results are compared to experimental results using CO2 as the cooling media at Reynold’s numbers ranging from 100,000 to 300,000. The results show the Nusselt number augmentation plateaus with increasing Reynolds number, in contrast to the decay observed in prior publications with air as the coolant media. Additionally, the CFD results indicate the discrete “W” geometry provides a 10% increase in Nusselt number augmentation relative to the angled ribbed turbulators.

computational fluid dynamics (CFD)

Heat Transfer Experiments of a 1st Stage Blade Cascade for Supercritical CO2 Oxy-Combustion Turbine Application

The results of internally cooled 1st stage blade (S1B) cascade testing in a supercritical CO2 environment is presented. The turbine blade design has been previously established for the end application of an oxy-combustion turbine operating in the Allam-Fetvedt cycle with turbine inlet conditions of 305 bar and 1150°C. The internally cooled blade features leading edge (LE) region impingement cooling, mid-section ribbed serpentine passages, and a pin-finned trailing edge (TE) region before cooling ejection holes. The geometry for the tested blade cascade has a cooled central blade with un-cooled blades on either side to match flowpath areas of the actual turbine. The flowpath reuses internal components previously employed for mid-section region ribbed serpentine passage experiments that established Nusselt number enhancement ratios over a range of Reynolds numbers from 100,000-400,000. New components include flow conditioning plates upstream and downstream of the blade cascade to adequately represent the flow field and blade external heat transfer coefficient profiles for the actual turbine. The cooled central blade utilizes uniform crystal temperature sensors (UCTS) with six sensors each on the blade pressure and suction surfaces distributed radially and from LE to TE. The post-processed UCTS quantified the maximum wall temperature seen at each installed sensor location. The test procedure consisted of establishing supercritical CO2 cooling flow temperature and flow rate and maintaining it throughout the test. The flow rate aims to match that for the actual in-service turbine blade design and is maintained through an orifice restriction to keep the pressure differential between internal cooling flow and external hot flow nearly constant. For the sCO2 flow path external to the blade, temperatures were ramped throughout the test via control of the test loop’s natural gas burner heater. The maximum temperature seen was 468°C and held constant for a duration of 10 minutes at which the blade metal temperature was predicted to be at its maximum before ramping down. For the turbine blade design for service inlet conditions, external flow path computational fluid dynamics (CFD) results and an internal cooling 1-D thermal and hydraulic flow network model using experimentally validated correlations served as thermal finite element (FE) boundary conditions to predict blade metal temperatures. These predicted temperatures were subsequently utilized in a structural FE model to predict blade life ratings dictated by Haynes 282 creep strength data, having a strong dependence on temperature. The boundary conditions experienced during testing are used in the same workflow and compared to the experimental results, with the goal of validating the analysis methodology and providing insight on the uncertainty in local metal temperature predictions.

20 FOSSIL-FUELED POWER PLANTS

Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH 2 ). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH 2 temperatures (20.3 – 24.2 K), pressures (100 – 350 kPa), and flow rates (0.010 – 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

Fuel Depot

Phase-field predictions of the influence of cooling rates during AM on the Evolution of Microstructures in Nickel-Based Single Crystal Superalloys

Additive manufacturing of single crystals made of Ni-based superalloys offers major cost savings for gas turbine engines with the inclusion of internal cooling channels. However, the lack of understanding of the effect of transient thermal conditions on solidification grain structure during additive manufacturing hinders the potential for process control to maintain the single crystal quality. The use of high-fidelity simulations through high performance computing to predict the evolution of the solidification microstructure will enhance the abilities to tailor the microstructures through process optimization. Phase field simulations are used to determine the effect local thermal conditions and defects on the stability of the solidification morphology, specifically with respect to the onset of columnar-to-equiaxed transition that results in the loss of the single crystal. The results are expected to be instrumental for developing future surrogate models to speed up the integration of design and manufacturing of turbine blades under the harsh in-service conditions.

36 MATERIALS SCIENCE

Optimal Design and Operation of Intensified Absorbers with 3D-Printed Packing for Solvent-Based CO 2 Capture

Many potential solvent-based carbon capture processes suffer from a high heat of absorption of CO 2 that adversely affects the thermodynamic driving force. While interstage coolers are often used for removing a portion of the generated heat by removing the solvent or a portion of the solvent from a stage and cooling and returning it back to the absorber, they can be placed only at discrete locations in the tower. This work investigates intensified absorbers with 3D-printed packing that includes an internal cooler and therefore can be potentially used for maximizing the operational efficiency of the absorbers for CO 2 capture. The intensified absorber is modeled by using a generic, first-principles, equation-oriented absorber column model. Since the placement of these intensified packings would cause a loss of area/volume used for mass transfer, optimization of the proposed intensified absorber is performed by optimally selecting the locations at which to place these devices and designing them such that the trade-off due to the addition of the heat removal area and the resulting loss in the mass transfer area is accounted for. Results show that optimally placed and designed intensified packings can lead to a significant increase in the capture efficiency of the process in comparison to a similar column with no internal cooling. It is also observed that by optimally placing and designing intensified packings, the lean solvent flow rate to the absorber can be decreased, and the CO 2 lean loading can be increased while still maintaining the same capture efficiency. These process changes can lead to a substantial reduction in the cost of capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

High temperature tensile properties of H13 tool steel fabricated via binder jet additive manufacturing

H13 is one of the most used steels for hot work tooling applications like die casting. Binder jet additive manufacturing (BJAM) offers a cost-effective solution to fabricate tools with performance enhancing features like internal cooling channels. While full densification of BJAM H13 has been demonstrated in the literature, the room and high temperature tensile properties of the material, and the effect of post-process treatments like hot isostatic pressing (HIP), and heat treatment (HT) are unknown. Here we use HIP+HT to obtain a combination of ultimate tensile strength (UTS) and elongation to failure that is superior to H13 fabricated via laser powder bed fusion and wire arc additive manufacturing. HIP+HT BJAM H13 has a superior UTS (1836 MPa) compared with conventionally processed (1671 MPa) H13 but has lower plastic elongation. We report that as-sintered samples have an extensive network of continuous grain boundary (GB) carbides that contribute to brittle fracture. HIP+HT results in partial dissolution of GB carbides and formation of a fine martensitic microstructure resulting in superior tensile strength and elongation compared with as-sintered H13. We use thermo-kinetic calculations to rationalize the effects of HIP+HT on microstructure and properties.

36 MATERIALS SCIENCE

Simple Heat Transfer Model for Film Cooling Applications

This report describes the development of a simple engineering model for film cooling. This model is used to derive a relationship between local wall temperature variations and key cooling performance parameters like local heat transfer coefficients and film effectiveness. This relation and method new and different from previously published models. The scope of this report includes the derivation of regression model equations for a flat plate with and without film cooling. The model equation for a flat plate without film cooling can be used to estimate local heat transfer coefficients using surface temperatures measured from infrared thermography. The model equation for the flat plate with film cooling can be used to estimate film cooling effectiveness, $η_f$, and heat transfer augmentation from the film cooling jet(s).

42 ENGINEERING

Computational Design to Advance AM Fabrication of High Gamma Prime Alloys for Hot Gas Path Components in Gas Turbine Engines: A Pathway to Enhanced Gas Turbine Efficiency and Energy Saving (Final CRADA Report)

Raising turbine inlet temperature is a key lever for improving industrial gas-turbine efficiency and power output, but it increases thermo-mechanical demands on hot-gas-path components. Additive manufacturing (AM), particularly laser powder bed fusion (L-PBF), enables complex internal cooling features in critical components such as turbine tip shoes that are difficult to produce by conventional casting. However, qualification of new high-temperature AM alloys and aggressive geometries is often limited by trial-and-error iteration of build parameters and post-build heat treatments, with cracking during stress relieving or hot isostatic pressing (HIP) being a recurring failure mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Tolerance Studies for the IMCC Rectilinear 6D Ionization Cooling Channel

As one of the main proposed future colliders that will enable us to reach energy scales capable of probing Beyond the Standard Model phenomena, muon colliders present unique challenges. To reach the desired luminosity, namely 1, 10, and 20 ab-1 for 3, 10, and 14 TeV, respectively, the six-dimensional emittance of the muon beam needs to be reduced significantly in a process described as muon cooling. The currently proposed system for muon cooling by the International Muon Collider Collaboration involves 6D initial cooling post-muon charge separation through rectilinear channels (A) before and rectilinear channels (B) after muon bunch merge, as well as a final 4D transverse cooling. This work focuses on the former stage of cooling with B rectilinear channels. First, we will compare its cooling performance against the rectilinear channel studied by the Muon Accelerator Program. Then, we do tolerance studies on all B stages, focusing on properties of the Radiofrequency (RF) cavities used in the channels and how they affect 6D emittance and transmission. We will evaluate the impact of these modifications on the overall performance of the rectilinear 6D cooling channel.

Karaaslan, Inci [Chicago U., EFI] (ORCID:000000033

The first high-redshift cavity power measurements of cool-core galaxy clusters with the International LOFAR Telescope

Radio-mode feedback associated with the active galactic nuclei (AGNs) at the cores of galaxy clusters injects a large amount of energy into the intracluster medium (ICM), offsetting radiative losses through X-ray emission. This mechanism prevents the ICM from rapidly cooling down and fueling extreme starburst activity as it accretes onto the central galaxies, and it is therefore a key ingredient in the evolution of galaxy clusters. However, the influence and mode of feedback at high redshifts (z ∼ 1) remains largely unknown. Low-frequency sub-arcsecond-resolution radio observations taken with the International LOFAR Telescope have demonstrated their ability to assist X-ray observations with constraining the energy output from the AGNs (or “cavity power”) in galaxy clusters, thereby enabling research at higher redshifts than before. In this pilot project, we tested this hybrid method on a high-redshift (0.6 < z < 1.3) sample of 13 galaxy clusters for the first time with the aim of verifying the performance of this method at these redshifts and providing the first estimates of the cavity power associated with the central AGN for a sample of distant clusters. We were able to detect clear radio lobes in three out of 13 galaxy clusters at redshifts of 0.7 < z < 0.9, and we used these detections in combination with ICM pressures surrounding the radio lobes obtained from standard profiles to calculate the corresponding cavity powers of the AGNs. Combining our results with the literature, the current data appear to suggest that the average cavity power peaked at a redshift ofz ∼ 0.4 and slowly decreases toward higher redshifts. However, we require more and tighter constraints on the cavity volume and a better understanding of our observational systematics to confirm any deviation of the cavity power trend from a constant level.

Astronomy & Astrophysics

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

Michael Lewandowski

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

SWME