Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Integrated Sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Integrated Sensor System Data Enhancement Package

The purpose of the Integrated Sensor System (ISS) Data Enhancement Package (DEP) is to improve the accuracies of the data obtained from the inflight tests performed on aircraft. The DEP is a microprocessor-based, flight-qualified electronics package that assimilates data from a Ring Laser Gyro (RGL) system, a standard NASA air data package, and other inputs. The DEP then processes these inputs in real-time to obtain optimal estimates of the aircraft velocity, attitude, and altitude. These estimates can be passed to the flight crew, downlinked, and/or stored on a mass storage medium. The DEP is now being built for the NASA Dryden Flight Research Center. Completion is anticipated in early 1984. A primary use of the ISS/DEP will be for the collection of quality data for the estimation of aircraft aerodynamic coefficients, including stability derivatives, using system identification methods. Initial anticipated applications will be on the AV-8B, F-14, and X-29 test aircraft.

Trankle, T. L.

Enhanced Laser-Induced Graphene Microfluidic Integrated Sensors (LIGMIS) for On-Site Biomedical and Environmental Monitoring

The convergence of microfluidic and electrochemical biosensor technologies offers significant potential for rapid, in-field diagnostics in biomedical and environmental applications. Traditional systems face challenges in cost, scalability, and operational complexity, especially in remote settings. Addressing these issues, laser-induced graphene microfluidic integrated sensors (LIGMIS) are presented as an innovative platform that integrates microfluidics and electrochemical sensors both comprised of laser-induced graphene. This study advances the LIGMIS concept by resolving issues of uneven fluid transport, increased hydrophobicity during storage, and sensor biofunctionalization challenges. Key innovations include Y-shaped reservoirs for consistent fluid flow, hydrophilic polyethyleneimine coatings to maintain wettability, and separable microfluidic and electrochemical components enabling isolated electrode nanoparticle metallization and biofunctionalization. Multiplexed electrochemical detection of the neonicotinoid imidacloprid and nitrate ions in environmental water samples yields detection limits of 707 nm and 10 -5.4 m with wide sensing ranges of 5–100 µm and 10 -5 –10 -1 m, respectively. Similarly, uric acid and calcium ions are detected in saliva, demonstrating detection limits of 217 nm and 10 -5.3 m with sensing ranges of 10–50 µm, and 10 -5 –10 -2.5 m, respectively. Overall, this biosensing demonstrates the capability of the LIGMIS platform for multiplexed detection in biologically complex solutions, with applications in environmental water quality monitoring and oral cancer screening.

environmental monitoring

Augmented Reality Technologies for Radiation Safety Training: A Systematic Review of Sensor Integration and Visualization Approaches

This paper presents a comprehensive systematic review examining the application of augmented reality (AR) and sensor technologies for visualizing ionizing radiation in virtual training environments. The review methodology involved systematic identification and analysis of the relevant literature based on predetermined criteria including publication type, year of publication, application domain, and technological approach. The literature search encompassed publications from 2011 to 2021 across four major academic databases: Web of Science, Google Scholar, IEEE Xplore, and Scopus. Through rigorous screening following PRISMA 2020 guidelines, 23 research articles met the inclusion criteria for detailed analysis. From 404 initial database records, 360 were excluded during title/abstract screening (primarily for lacking AR components, radiation focus, or training applications) and 4 during full-text assessment (all for lacking sensor integration). The findings reveal that AR-based ionizing radiation visualization has been successfully implemented across diverse domains, including nuclear facility operations, medical procedures, CERN research activities, and educational and monitoring applications. The analysis identified multiple dimensions of impact, encompassing distinct benefits, emerging opportunities, and implementation challenges associated with AR deployment for ionizing radiation training. Each of these dimensions is comprehensively examined and documented within this review. Additionally, this study identifies critical research gaps that currently limit the full potential of AR technology in supporting ionizing radiation training programs. These gaps are systematically analyzed and discussed to establish clear directions for future research endeavors in this emerging field.

61 - RADIATION PROTECTION AND DOSIMETRY

Performance Testing of Enhanced Linear Variable Integrated Sensor (ELVIS III) for LVDTs

The Enhanced Linear Variable Intrinsic Sensor (ELVIS) was a 2024 breakthrough discovery by Idaho National Laboratory (INL) in terms of further innovating the usage of all linear variable differential transformers (LVDTs) and enhancing their performance in harsh environments. In irradiation tests conducted within material test reactors (MTRs), LVDTs with an internal temperature sensing capability can address several critical challenges. This report focuses on performance testing of the ELVIS III device with new hybrid LVDTs provided by the Institute for Energy Technology (IFE), which is the world’s sole supplier of nuclear-grade LVDTs. The ELVIS III device was evaluated in terms of temperature showcasing promising results comparable to a typical type-K thermocouple (TC).

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

A research on integrated-circuit sensors for gas chromatography

Fabrication of a miniature gas chromatograph column using integrated circuit technology was studied and found to be feasible. A bonding problem of forming a strong, gas tight seal between two wafers of silicon has prevented the completion of the column design. Continuing research using tin or a chromium-gold bond promises to overcome the problems of using the proposed gold-eutectic bond. Specifications for the miniature gas chromatograph column are: a spiral capillary column of semi-circular cross section, 30 micron radius, and a total length of 6.9 meters etched into a silicon structure 50 mm in diameter and 0.625 mm thick.

Source record

Integrated temperature sensor

Proposed temperature-sensor/failure-detection system utilizes liquid-filled sensors attached as matrix to monitored surface. Fluid passages are integral part of monitored surface or are small-diameter tubing in good thermal contact with monitored surface. System offers significant advantages over discrete sensors in terms of simplicity, reliability, cost, ease of installation, maintainability, and weight.

Herring, R. L.

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION

Large format SEC orthicon integrating television sensor for LST

The Large Space Telescope will employ a 70 mm format SEC type television camera tube as the data sensor for one or more scientific instruments. The characteristics of this tube are described. The current performance is characterized by an MTF of 50% at 20 line pairs per mm and a signal-to-noise ratio that is about one-half the theoretical based on the square root of the number of photoelectrons. The paper presents some astronomical results and the status of the environmental testing of the tube. Other topics such as radiation sensitivity and thermal design are also discussed.

Lowrance, J. L.

Large, high resolution integrating TV sensor for astronomical appliations

A magnetically focused SEC tube developed for photometric applications is described. Efforts to design a 70 mm version of the tube which meets the ST f/24 camera requirements of the space telescope are discussed. The photometric accuracy of the 70 mm tube is executed to equal that of the previously developed 35 mm tube. The tube meets the criterion of 50 percent response at 20 cycles/mm in the central region of the format, and, with the removal of the remaining magnetic parts, this spatial frequency is expected over almost all of the format. Since the ST f/24 camera requires sensitivity in the red as well as the ultraviolet and visible spectra, attempts were made to develop tubes with this ability. It was found that it may be necessary to choose between red and u.v. sensitivity and tradeoff red sensitivity for low background. Results of environmental tests indicate no substantive problems in utilizing it in a flight camera system that will meet the space shuttle launch requirements.

Spitzer, L. J.

Miniature piezoresistive solid state integrated pressure sensors

The characteristics of silicon pressure sensors with an ultra-small diaphragm are described. The pressure sensors utilize rectangular diaphragm as small as 0.0127 x 0.0254 cm and a p-type Wheatstone bridge consisting of diffused piezoresistive elements, 0.000254 cm by 0.00254 cm. These sensors exhibit as high as 0.5 MHz natural frequency and 1 mV/V/psi pressure sensitivity. Fabrication techniques and high frequency results from shock tube testing and low frequency comparison with microphones are presented.

Kahng, S. K.

A fifty channel electrically scanned pressure module

A unique miniature pressure sensor system consisting of an array of fifty integrated sensor pressure transducers with integral electronic logic and switching is described. Solid state processing of the piezoresistive array is combined with hybrid microelectronics to produce a very small, dense (80 cc displacement), high reliability pressure measuring system. Application to high speed data acquisition, energy conservation in wind tunnels and flight test is discussed. Test data are presented typifying system performance.

Mallon, J. R.

Analysis and design of a surface-wave-scanned optical sensor array

This paper treats a scheme for converting the information of the spatial pattern of light of an image into a time-varying voltage pattern by the use of acoustic surface waves. After a brief review of earlier work, the application of the scheme to vidicon-type applications is tested by a feasibility calculation. This is followed by a consideration of various physical configurations possible and some experimental results. The rest of the paper deals with the subject of sensor array design. Included here are discussions of system components, methods of computation used, optimization, and the design of some integrated sensor arrays. The work shows that an integrated acoustically scanned array sensor of 250 or more elements per line in a 5 cm length, with scanning at TV frame rates, should be possible.

Shaw, K. A.

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Embedded Sensing in Additive Manufacturing Metal and Polymer Parts: A Comparative Study of Integration Techniques and Structural Health Monitoring Performance

This study presents a comparative evaluation of post-process sensor integration in additively manufactured (AM) metal and the in-situ process for polymer structures for structural health monitoring (SHM), with an emphasis on embedded sensors. Geometrically identical specimens were fabricated using copper via metal fused filament fabrication (FFF) and PLA via polymer FFF, with piezoelectric transducers (PZTs) inserted into internal cavities to assess the influence of material and placement on sensing fidelity. Mechanical testing under compressive and point loads generated signals that were transformed into time–frequency spectrograms using a Short-Time Fourier Transform (STFT) framework. An engineered RGB representation was developed, combining global amplitude scaling with an amplitude-envelope encoding to enhance contrast and highlight subtle wave features. These spectrograms served as inputs to convolutional neural networks (CNNs) for classification of load conditions and detection of damage-related features. Results showed reliable recognition in both copper and PLA specimens, with CNN classification accuracies exceeding 95%. Embedded PZTs were especially effective in PLA, where signal damping and environmental sensitivity often hinder surface-mounted sensors. This work demonstrates the advantages of embedded sensing in AM structures, particularly when paired with spectrogram-based feature engineering and CNN modeling, advancing real-time SHM for aerospace, energy, and defense applications.

additive manufacturing

Variability of reflectance measurements with sensor altitude and canopy type

Data were acquired on canopies of mature corn planted in 76 cm rows, mature soybeans planted in 96 cm rows with 71 percent soil cover, and mature soybeans planed in 76 cm rows with 100 percent soil cover. A LANDSAT band radiometer with a 15 degree field of view was used at ten altitudes ranging from 0.2 m to 10 m above the canopy. At each altitude, measurements were taken at 15 cm intervals also a 2.0 m transect perpendicular to the crop row direction. Reflectance data were plotted as a function of altitude and horizontal position to verify that the variance of measurements at low altitudes was attributable to row effects which disappear at higher altitudes where the sensor integrate across several rows. The coefficient of variation of reflectance decreased exponentially as the sensor was elevated. Systematic sampling (at odd multiples of 0.5 times the row spacing interval) required fewer measurements than simple random sampling over row crop canopies.

Daughtry, C. S. T.