Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation Set Points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Instrumentation Set Points

The mission of the National Criticality Experiments Research Center (NCERC) at the Device Assembly Facility (DAF) is to conduct experiments on critical assemblies with fissile material at or near criticality in order to explore reactivity phenomena and to operate the assemblies in the region from subcritical through delayed critical to beyond prompt critical. The critical assemblies contain fissile and other materials that are used to carry out research and development activities in support of criticality safety, accident simulation and analysis, weapons and reactor design, and other programmatic needs. There are four critical assemblies at the NCERC; Comet, Flat-Top, Godiva, and Planet. There are two Safety Significant systems, the SCRAM Safety System (SSS) and the Nuclear Instrumentation (NI) system, that are integral programmatic systems for safe operations at the NCERC. System Design Descriptions (SDDs) have been developed for the four critical assembly machines as well as for the SSS (this SDD also includes information pertaining to the Operational Interlock System (OIS)) and NI system. This document provides all of the NCERC critical assembly machines’ set points and basis for these set points, as the DOE standard suggests.

42 ENGINEERING↗

The design, fabrication and delivery of a spacelab neutral buoyancy Instrument Pointing System (IPS) mockup

Underwater simulations of EVA contingency operations such as manual jettison, payload disconnect, and payload clamp actuation were used to define crew aid needs and mockup pecularities and characteristics to verify the validity of simulation using the trainer. A set of mockup instrument pointing system tests was conducted and minor modifications and refinements were made. Flight configuration struts were tested and verified to be operable by the flight crew. Tasks involved in developing the following end items are described: IPS gimbal system, payload, and payload clamp assembly; the igloos (volumetric); spacelab pallets, experiments, and hardware; experiment, and hardware; experiment 7; and EVA hand tools, support hardware (handrails and foot restraints). The test plan preparation and test support are also covered.

Vanvalkenburgh, C. N.↗

Digital control of diode laser for atmospheric spectroscopy

A system is described for remote absorption spectroscopy of trace species using a diode laser tunable over a useful spectral region of 50 to 200 cm(-1) by control of diode laser temperature over range from 15 K to 100 K, and tunable over a smaller region of typically 0.1 to 10 cm(-1) by control of the diode laser current over a range from 0 to 2 amps. Diode laser temperature and current set points are transmitted to the instrument in digital form and stored in memory for retrieval under control of a microprocessor during measurements. The laser diode current is determined by a digital to analog converter through a field effect transistor for a high degree of ambient temperature stability, while the laser diode temperature is determined by set points entered into a digital to analog converter under control of the microprocessor. Temperature of the laser diode is sensed by a sensor diode to provide negative feedback to the temperature control circuit that responds to the temperature control digital to analog converter.

Menzies, R. T.↗

Portable Temperature Set-Point Controller

Two off-the-shelf instruments combine to control chamber temperature over wide range. Portable controller for environmental test chambers changes temperatures automatically over range of -300 degrees to +400 degrees F (-184 degrees to + 204 degrees C). Unit controls rate of temperature change and time at given temperature. Controller developed to meet NASA Shuttle test requirements.

Milner, J. F.↗

Attitude and articulation control concepts for the Earth Observing System

A study of pointing requirements and control approaches for the Earth Observing System, EOS, is presented. The proposed instrument set includes several massive instruments with varied articulation requirements, and pointing control requirements in several cases tighter than 0.01 degrees. Approaches to multipayload control and stability are explored, including: (a) the use of interconnected but dynamically isolated payload modules on a large platform, each with independent inertial control, and (b) precision basebody control of smaller platforms, with momentum compensated articulation and on-orbit dynamic balancing of spin-scan instruments. Results from multibody spacecraft models highlight potential payload dynamic interaction problems and suggest the need for dynamic isolation and disturbance rejection control techniques.

Bell, C. E.↗

Surface accuracy measurement system deployable reflector antennas

Conceptual optical sensor configurations for measuring the surface deformations of large, deployable space antennas are described. These antennas include precision deployable reflectors up to 30 meters diameter and 1000 GHz frequency and mesh deployable reflectors up to 100 meters diameter and 30 GHz frequency. For each representative antenna configuration, the surface deformation sensor provides continuous, real-time measurements at a sufficient number of sample points to be compatible with active surface control. Moreover, the sensor system does not interfere with the mechanical or microwave characteristics of either the antenna surface or the feed. For the applications considered, the sensor system consists of a central receiver ring containing six to ten long focal length, angle measuring instruments, each viewing a dedicated set of bright point targets at the antenna. The targets, either light emitting diodes or illuminated retroreflectors, are modulated to eliminate errors from spurious backgrounds. Very preliminary performance estimates indicate that the sensor system, using commerical grade components, can produce a 20th to a 30th wavelength accuracy (3 sigma).

Neiswander, R. S.↗

Background observations on the SMM high energy monitor at energies greater than 10 MeV

The background rate in any gamma ray detector on a spacecraft in near-earth orbit is strongly influenced by the primary cosmic ray flux at the spacecraft's position. Although the direct counting of the primary cosmic rays can be rejected by anticoincident shields, secondary production cannot be. Secondary production of gamma rays and neutrons in the instrument, the spacecraft, and the earth's atmospheric are recorded as background. A 30 day data base of 65.5 second records has been used to show that some of the background rates observed on the Gamma Ray Spectrometer can be ordered to a precision on the order of 1 percent This ordering is done with only two parameters, namely the cosmic ray vertical cutoff rigidity and the instrument's pointing angle with respect to the earth's center. This result sets limits on any instrumental instability and also on any temporal or spatial changes in the background radiation field.

Forrest, D. J.↗

Space Suit Portable Life Support System (PLSS) 2.0 Pre-Installation Acceptance (PIA) Testing

Following successful completion of the space suit Portable Life Support System (PLSS) 1.0 development and testing in 2011, the second system-level prototype, PLSS 2.0, was developed in 2012 to continue the maturation of the advanced PLSS design. This advanced PLSS is intended to reduce consumables, improve reliability and robustness, and incorporate additional sensing and functional capabilities over the current Space Shuttle/International Space Station Extravehicular Mobility Unit (EMU) PLSS. PLSS 2.0 represents the first attempt at a packaged design comprising first generation or later component prototypes and medium fidelity interfaces within a flight-like representative volume. Pre-Installation Acceptance (PIA) is carryover terminology from the Space Shuttle Program referring to the series of test sequences used to verify functionality of the EMU PLSS prior to installation into the Space Shuttle airlock for launch. As applied to the PLSS 2.0 development and testing effort, PIA testing designated the series of 27 independent test sequences devised to verify component and subsystem functionality, perform in situ instrument calibrations, generate mapping data, define set-points, evaluate control algorithms, evaluate hardware performance against advanced PLSS design requirements, and provide quantitative and qualitative feedback on evolving design requirements and performance specifications. PLSS 2.0 PIA testing was carried out in 2013 and 2014 using a variety of test configurations to perform test sequences that ranged from stand-alone component testing to system-level testing, with evaluations becoming increasingly integrated as the test series progressed. Each of the 27 test sequences was vetted independently, with verification of basic functionality required before completion. Because PLSS 2.0 design requirements were evolving concurrently with PLSS 2.0 PIA testing, the requirements were used as guidelines to assess performance during the tests; after the completion of PIA testing, test data served to improve the fidelity and maturity of design requirements as well as plans for future advanced PLSS functional testing.

Anchondo, Ian↗

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

Application of microprocessors in an upper atmosphere instrument package

A servo-driven magnetometer table measuring offset from magnetic north has been developed by NASA to calculate payload azimuth required to point at a celestial target. Used as an aid to the study of gamma-ray phenomena, the high-altitude balloon-borne instrument determines a geocentric reference system, and calculates a set of pointing directions with respect to the system. Principal components include the magnetometer, stepping motor, microcomputer, and gray code shaft encoder. The single-chip microcomputer is used to control the orientation of the system, and consists of a central processing unit, program memory, data memory and input/output ports. Principal advantages include a low power requirement, consuming 6 watts, as compared to 30 watts consumed by the previous system.

Lim, T. S.↗

SIRTF Focal Plane Survey: A Pre-flight Error Analysis

This report contains a pre-flight error analysis of the calibration accuracies expected from implementing the currently planned SIRTF focal plane survey strategy. The main purpose of this study is to verify that the planned strategy will meet focal plane survey calibration requirements (as put forth in the SIRTF IOC-SV Mission Plan [4]), and to quantify the actual accuracies expected. The error analysis was performed by running the Instrument Pointing Frame (IPF) Kalman filter on a complete set of simulated IOC-SV survey data, and studying the resulting propagated covariances. The main conclusion of this study is that the all focal plane calibration requirements can be met with the currently planned survey strategy. The associated margins range from 3 to 95 percent, and tend to be smallest for frames having a 0.14" requirement, and largest for frames having a more generous 0.28" (or larger) requirement. The smallest margin of 3 percent is associated with the IRAC 3.6 and 5.8 micron array centers (frames 068 and 069), and the largest margin of 95 percent is associated with the MIPS 160 micron array center (frame 087). For pointing purposes, the most critical calibrations are for the IRS Peakup sweet spots and short wavelength slit centers (frames 019, 023, 052, 028, 034). Results show that these frames are meeting their 0.14" requirements with an expected accuracy of approximately 0.1", which corresponds to a 28 percent margin.

pointing↗

Space Suit Portable Life Support System (PLSS) 2.0 Pre-Installation Acceptance (PIA) Testing

Following successful completion of the space suit Portable Life Support System (PLSS) 1.0 development and testing in 2011, the second system-level prototype, PLSS 2.0, was developed in 2012 to continue the maturation of the advanced PLSS design which is intended to reduce consumables, improve reliability and robustness, and incorporate additional sensing and functional capabilities over the current Space Shuttle/International Space Station Extravehicular Mobility Unit (EMU) PLSS. PLSS 2.0 represents the first attempt at a packaged design comprising first generation or later component prototypes and medium fidelity interfaces within a flight-like representative volume. Pre-Installation Acceptance (PIA) is carryover terminology from the Space Shuttle Program referring to the series of test sequences used to verify functionality of the EMU PLSS prior to installation into the Space Shuttle airlock for launch. As applied to the PLSS 2.0 development and testing effort, PIA testing designated the series of 27 independent test sequences devised to verify component and subsystem functionality, perform in situ instrument calibrations, generate mapping data to define set-points for control algorithms, evaluate hardware performance against advanced PLSS design requirements, and provide quantitative and qualitative feedback on evolving design requirements and performance specifications. PLSS 2.0 PIA testing was carried out from 3/20/13 - 3/15/14 using a variety of test configurations to perform test sequences that ranged from stand-alone component testing to system-level testing, with evaluations becoming increasingly integrated as the test series progressed. Each of the 27 test sequences was vetted independently, with verification of basic functionality required before completion. Because PLSS 2.0 design requirements were evolving concurrently with PLSS 2.0 PIA testing, the requirements were used as guidelines to assess performance during the tests; after the completion of PIA testing, test data served to improve the fidelity and maturity of design requirements as well as plans for future advanced PLSS functional testing.

Watts, Carly↗

The HySICS Pointing System: Precision Pointing of CLARREO Pathfinder from the ISS

The CLARREO (Climate Absolute Radiance and Refractivity Observatory) Pathfinder (CPF) mission will measure Earth-reflected sunlight with unparalleled accuracy over existing reflected solar (RS) sensors and will also serve as an on-orbit inter-calibration reference to other orbiting sensors. In order to achieve these goals, the HySICS (HyperSpectral Imager for Climate Science) instrument will need to be pointed at a diverse set of targets including: nadir earth, co-aligned earth scans with other orbiting sensors, the Sun, and the Moon. The HySICS Pointing System (HPS) was developed to provide independent pointing at these targets from its mounting location on the ISS. This paper is focused on the HPS and describes: an overview of the CPF mission, an overview of the HPS requirements, the HPS hardware architecture, the various pointing modes that allow the HPS to point at its targets, challenges associated with performing this mission on the ISS, test results from subsystem-level HPS testing, and finally lessons learned that pertain to algorithm/software development and to the benefits of reusing pointing control hardware/architecture from the TSIS-1 mission that also has a 2-axis pointing system on the ISS from the development process.

orbit↗

ICESat-2 Constraint Analysis and Monitoring System (CAMS)

The Ice, Cloud and land Elevation Satellite-2 was launched on 15 September 2018 with mission goals of collecting surface elevation data that can precisely measure ice sheet topography, cloud and aerosol heights, land topography, as well as vegetation height for ecosystems studies. The Constraint Analysis and Monitoring System (CAMS) was implemented as an ICESat-2 ground system element to perform Mission Planning and Spacecraft Safety Monitoring. Mission Planning requires CAMS to serve as an interface between the Project Science Office, the Instrument Support Facility and the Mission Operation Control Center. By ingesting inputs received from all three groups, the CAMS builds an optimized and deconflicted timeline of science and instrument activities. Based upon the timeline of activities, the CAMS utilizes a sophisticated set of algorithms to model and predict the location and pointing of the spacecraft instrument relative to the Earth and Sun. From the predicted position and pointing, the CAMS provides precise monitoring of instrument health, and performs space asset laser conjunction detection. Furthermore, the CAMS determines alternative plans to prevent detected health constraint violations or mitigate potential laser conjunctions. This paper provides an overview of the CAMS and presents the operational performance of planning science and instrument activities, the monitoring of instrument constraints for health and safety, and the space asset laser conjunction screening and mitigation process.

ICESat-2↗

Laboratory evaluation of an airborne ozone instrument that compensates for altitude/sensitivity effects

One problem encountered in the use of air-quality instrumentation on aircraft is the variation of instrument sensitivity with pressure as the result of altitude changes of the aircraft. Many instruments experience sensitivity changes of as much as a factor of 2 at altitudes of 6 km. Discussed are recent modifications to a chemiluminescent (ethylene) ozone detector that allow the instrument to automatically compensate for pressure/sensitivity effects. The modification provides automated mass flow rate control for both the sample and ethylene gas flows. The flow control systems maintain flow rate to within 15 percent for a 100-torr instantaneous pressure change, and flow rates are returned to the desired set points within 10 s after the pressure change. During simulated altitude changes (300 m/min from mean sea level to 3-km altitude), flow rates were controlled to within 3 percent of the set point. Laboratory data are summarized verifying the operation of the instrument for a pressure range of 760 torr (sea level) to 350 torr (approximately 20,000 ft) and an ozone concentration range from 20 to approximately 700 ppb.

Gregory, G. L.↗

DGEN Aeropropulsion Research Turbofan Source-Diagnostic Test: Experimental Setup and Acoustic-Data Structure

The experimental setup of, and available data from a recent core/combustor-noise source-diagnostic test utilizing a small turbofan engine are described. The 2019 test campaign continued the investigation of the core/combustor-noise component of aircraft-propulsor noise begun in an earlier baseline test, but with a more extensive acoustic-instrumentation layout. The purpose of both tests was to better understand the impact on civilian-transport airport-community noise from turbofan-combustor sources and thereby to lay the foundation for improved noise-prediction methods and noise-mitigation techniques. Simultaneous high-data-rate acoustic measurements were obtained using a circumferential sensor array at the core nozzle exit in conjunction with sideline and farfield microphone arrays. The test matrix contained engine operational points from engine idle to maximum power and was repeated for different circumferential and sideline array configurations, as well as for redundancy. The extensive data set (up to 93 channels of data and various configurations) allows the application of advanced source-separation and phased-array methods to elucidate not only the core-noise structure, but also the propagation characteristics of other propulsion noise sources. The present report provides a detailed description of the different test points, their associated instrumentation layouts, and the structure of the acquired data set. Results from various data analyses are reported separately.

Aeroacoustics↗

Controlled experiments from the Space Shuttle

A study has been carried out to identify the controlled space physics and plasma physics experiments that can be performed from the Space Shuttle on sortie missions of 7 to 30-day duration. An experiment facility of this type appears to be well-matched to the sortie missions capability, and a technically feasible laboratory can provide a base for an extensive and significant research program to be carried out during the 1980-1990 time period. The laboratory, known as PPEPL, consists of a 33-ft pallet of instruments connected to a 25-ft pressurized control module. Two deployable 50-m booms, two subsatellites, a high power transmitter, a multipurpose high-power accelerator array, a set of deployable canisters for releases, and a gimbaled platform for pointing instruments are the primary systems mounted on the pallet.

Scarf, F. L.↗

Global reference frame: Intercomparison of results (SLR, VLBI and GPS)

The terrestrial reference frame (TRF) is realized by a set of positions and velocities derived from a combination of the three space geodetic techniques, SLR, VLBI and GPS. The standard International TRF is constructed by the International Earth Rotation Service in such a way that it is stable with time and the addition of new data. An adopted model for overall plate motion, NUVEL-1 NNR, defines the conceptual reference frame in which all the plates are moving. In addition to the measurements made between reference points within the space geodetic instruments, it is essential to have accurate, documented eccentricity measurements from the instrument reference points to ground monuments. Proper local surveys between the set of ground monuments at a site are also critical for the use of the space geodetic results. Eccentricities and local surveys are, in fact, the most common and vexing sources of error in the use of the TRF for such activities as collocation and intercomparison.

Ma, Chopo↗