Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spatially Resolved Raman Spectroscopic Investigation of Uranyl Fluoride: A Case Study in the Importance of Instrument Optimization

Raman spectroscopy is an emerging technique for rapid and nondestructive analysis of nuclear materials for forensic and nonproliferation applications as it is a powerful tool for distinguishing multiple chemical forms of materials with similar stoichiometries. Recent developments in spectroscopic software have enabled rapid data collection with high-speed Raman spectroscopic mapping capabilities. However, some uranium-rich materials are susceptible to degradation in humid air and/or laser-induced phase transformations. To mitigate environmental or measurement-related sample degradation of potential samples of interest, we have taken a systematic approach to define optimized data collection parameters for high-throughput measurements of uranyl fluoride (UO 2 F 2 ), which is an important intermediate material in the nuclear fuel cycle. First, we systematically describe the influence of optical magnification (5× to 100×), laser power, and exposure time on obtained signal for identical particles of UO 2 F 2 and find that at low laser power and exposure times, comparable signal is obtained regardless of optical magnification. Second, we ensure sample integrity during data collection, and third, collect spectroscopic maps that employ optimized parameters to reduce the time required to obtain spatially resolved spectroscopic information. Reductions of 90% and 99% in measurement times are discussed as they relate to differences in resolving spectroscopic features of particles in identical mapping areas. Finally, during this work, we found that additional data processing options were needed and thus developed a customized Python script for importing, processing, analyzing, and visualizing Raman spectroscopic map data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MethodOpt: a Shiny-based graphical user interface for multivariate optimization of sampling and analytical instrumentation

Method optimization is an important step in producing useful data in various experimental settings involving the use of sampling and analytical instrumentation, such as gas-chromatography mass-spectrometry or other analytical techniques. However, traditional optimization techniques often lack the sophistication of more modern optimization techniques developed in areas of applied mathematics. A graphical user interface has been developed that implements a multivariate, multi-objective optimization technique for spectra-generating sampling and analytical instrumentation, which saves substantial time and resources compared to the more traditional approaches to method development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface science insight note: Optimizing XPS instrument performance for quantification of spectra

X-ray photoelectron spectroscopy (XPS) provides quantitative information from photoemission peaks and shapes observed within the background due to the inelastic scattering of photoelectrons. To quantify the signal, both photoemission peaks and background in spectra must be adjusted for instrumental transmission variations that are a consequence of changes in efficiency when recording electrons with different kinetic energy. While it is generally assumed that correcting spectroscopic data for transmission is a necessary part of quantification by XPS, there are consequences for the quantification of spectra measured using an instrument for which transmission has significant curvature. In this Insight, the implications of curvature in transmission characteristics are discussed and a method based on XPS microscopy is proposed that ensures the transmission response of an instrument is free from significant curvature. An example of an instrument for which a flat transmission response is presented is achieved through collecting spectra using lens modes designed to measure stigmatic images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Usage of Observing System Simulation Experiments and Reinforcement Learning to Optimize Experimental Design and Operation

Various organizations regularly conduct field campaigns across the globe designed to probe and improve atmospheric process understanding. However, these campaigns are mostly designed ad-hoc, and rely on anecdotes and knowledge of what was successful in previous campaigns. Such ad-hoc experiment design results in sub-optimal instrument siting and operation strategies. Inadequate targeted data collection of extreme weather is a major limitation to Earth and Environmental Systems Science Division (EESSD)’s goals of data model integration (4.5.3), which limits the knowledge gained through the collected observations, holding back significant advances in predictability. While advances in instrument design are always chipping away at these limitations, we are not optimally utilizing the instrumentation we currently possess.

54 ENVIRONMENTAL SCIENCES↗

Origins and consequences of asymmetric nano-FTIR interferograms

Infrared scattering-type near-field optical microscopy, IR s-SNOM, and its broadband variant, nano-FTIR, are pioneering, flagship techniques for their ability to provide molecular identification and material optical property information at a spatial resolution well below the far-field diffraction limit, typically less than 25 nm. While s-SNOM and nano-FTIR instrumentation and data analysis have been discussed previously, there is a lack of information regarding experimental parameters for the practitioner, especially in the context of previously developed frameworks. Like conventional FTIR spectroscopy, the critical component of a nano-FTIR instrument is an interferometer. However, unlike FTIR spectroscopy, the resulting interference patterns or interferograms are typically asymmetric. Here, we unambiguously describe the origins of asymmetric interferograms recorded with nano-FTIR instruments, give a detailed analysis of potential artifacts, and recommend optimal instrument settings as well as data analysis parameters.

47 OTHER INSTRUMENTATION↗

Domain Knowledge Guided Bayesian Optimization For Autonomous Alignment Of Complex Scientific Instruments

Bayesian Optimization (BO) is a powerful tool for optimizing complex non-linear systems. However, its performance degrades in high-dimensional problems with tightly coupled parameters and highly asymmetric objective landscapes, where rewards are sparse. In such needle-in-a-haystack scenarios, even advanced methods like trust-region BO (TurBO) often lead to unsatisfactory results. We propose a domain knowledge guided Bayesian Optimization approach, which leverages physical insight to fundamentally simplify the search problem by transforming coordinates to decouple input features and align the active subspaces with the primary search axes. We demonstrate this approach's efficacy on a challenging 12-dimensional, 6-crystal Split-and-Delay optical system, where conventional approaches, including standard BO, TuRBO and multi-objective BO, consistently led to unsatisfactory results. When combined with an reverse annealing exploration strategy, this approach reliably converges to the global optimum. The coordinate transformation itself is the key to this success, significantly accelerating the search by aligning input co-ordinate axes with the problem's active subspaces. As increasingly complex scientific instruments, from large telescopes to new spectrometers at X-ray Free Electron Lasers are deployed, the demand for robust high-dimensional optimization grows. Our results demonstrate a generalizable paradigm: leveraging physical insight to transform high-dimensional, coupled optimization problems into simpler representations can enable rapid and robust automated tuning for consistent high performance while still retaining current optimization algorithms.

FOS: Computer and information sciences↗

The Spectroscopic Stage-5 Experiment

The existence, properties, and dynamics of the dark sectors of our universe pose fundamental challenges to our current model of physics, and large-scale astronomical surveys may be our only hope to unravel these long-standing mysteries. In this white paper, we describe the science motivation, instrumentation, and survey plan for the next-generation spectroscopic observatory, the Stage-5 Spectroscopic Experiment (Spec-S5). Spec-S5 is a new all-sky spectroscopic instrument optimized to efficiently carry out cosmological surveys of unprecedented scale and precision. The baseline plan for Spec-S5 involves upgrading two existing 4-m telescopes to new 6-m wide-field facilities, each with a highly multiplexed spectroscopic instrument capable of simultaneously measuring the spectra of 13,000 astronomical targets. Spec-S5, which builds and improves on the hardware used for previous cosmology experiments, represents a cost-effective and rapid approach to realizing a more than 10$\times$ gain in spectroscopic capability compared to the current state-of-the-art represented by the Dark Energy Spectroscopic Instrument project (DESI). Spec-S5 will provide a critical scientific capability in the post-Rubin and post-DESI era for advancing cosmology, fundamental physics, and astrophysics in the 2030s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control Systems Design for STS Accelerator

The Second Target Station (STS) Project will expand the capabilities of the existing Spallation Neutron Source (SNS), with a suite of neutron instruments optimized for long wavelengths. A new accelerator transport line will be built to deliver one out of four SNS pulses to the new target station. The Integrated Control Systems (ICS) will provide remote control, monitoring, OPI, alarms, and archivers for the accelerator systems, such as magnets power supply, vacuum devices, and beam instrumentation. The ICS will upgrade the existing Linac LLRF controls to allow independent operation of the FTS and STS and support different power levels of the FTS and STS proton beam. The ICS accelerator controls are in the phase of preliminary design for the control systems of magnet power supply, vacuum, LLRF, Timing, Machine protection system (MPS), and computing and machine network. The accelerator control systems build upon the existing SNS Machine Control systems, use the SNS standard hardware and EPICS software, and take full advantage of the performance gains delivered by the PPU Project at SNS.

Yan, Jay↗

Leveraging Multiple Raman Excitation Wavelength Systems for Process Monitoring of Nuclear Waste Streams

Processing nuclear waste from sites such as Hanford is a significant environmental cleanup need while being a significant logistical challenge. Integration of process monitoring tools, that can provide in situ and real-time feedback about the process, can significantly alleviate needs to collect grab samples for process control and product characterization. Raman spectroscopy paired with chemometric analysis is one process monitoring tool that can provide chemical composition information on a large number of chemical targets in nuclear waste streams. However, methods to improve limits of detection as well as drop uncertainty in quantification are needed. Optimizing instrument specifications can achieve this, here this is demonstrated by comparing limits of detection for key analytes when using Raman systems with 671 nm, 532 nm, and 405 nm excitation wavelengths. Generally, limits of detection decease (allowing the measurement of lower salt concentrations) with decreasing wavelength. Similarly, data collection times and averaging were optimized. Finally, multiple chemometric modeling approaches were leveraged, including multiblock methods that combined data from all three Raman systems to simultaneously quantify targets with improved sensitivity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

Monitoring agroecosystem productivity and phenology at a national scale: A metric assessment framework

Effective measurement of seasonal variations in the timing and amount of production is critical to managing spatially heterogeneous agroecosystems in a changing climate. Although numerous technologies for such measurements are available, their relationships to one another at a continental extent are unknown. Using data collected from across the Long-Term Agroecosystem Research (LTAR) network and other networks, we investigated correlations among key metrics representing primary production, phenology, and carbon fluxes in croplands, grazing lands, and crop-grazing integrated systems across the continental U.S. Metrics we examined included gross primary productivity (GPP) estimated from eddy covariance (EC) towers and modelled from the Landsat satellite, Landsat NDVI, and vegetation greenness (Green Chromatic Coordinate, GCC) from tower-mounted PhenoCams for 2017 and 2018. Overall, our analysis compared production dynamics estimated from three independent ground and remote platforms using data for 34 agricultural sites constituting 51 site-years of co-located time series. Pairwise sensor comparisons across all four metrics revealed stronger correlation and lower root mean square error (RMSE) between end of season (EOS) dates (Pearson R ranged from 0.6 to 0.7 and RMSE from 32.5 to 67.8) than start of season (SOS) dates (0.46 to 0.69 and 40.4 to 66.2). Overall, moderate to high correlations between SOS and EOS metrics complemented one another except at some lower productivity grazing land sites where estimating SOS can be challenging. Growing season length estimates derived from 16-day satellite GPP (179.1 days) were significantly longer than those from PhenoCam G CC (70.4 days, p adj < 0.0001) and EC GPP (79.6 days, p adj < 0.0001). Landscape heterogeneity did not explain differences in SOS and EOS estimates. Annual integrated estimates of productivity from EC GPP and PhenoCam G CC diverged from those estimated by Landsat GPP and NDVI at sites where annual production exceeds 1000 gC/m –2 yr –1 . Based on our results, we developed a “metric assessment framework” that articulates where and how metrics from satellite, eddy covariance and PhenoCams complement, diverge from, or are redundant with one another. The framework was designed to optimize instrumentation selection for monitoring, modeling, and forecasting ecosystem functioning with the ultimate goal of informing decision-making by land managers, policy-makers, and industry leaders working at multiple scales.

54 ENVIRONMENTAL SCIENCES↗

Simulation and measurement of the dynamic strain response in a prototypical spallation target

The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.

Dynamic strain response↗

Evolution of Mass Spectrometers for High m / z Biological Ion Formation, Transmission, Analysis and Detection: A Personal Perspective

Mass spectrometry (MS) has become an essential tool in virtually all academic, pharmaceutical, and biopharmaceutical analytical laboratories. The specialized and bespoke area of MS research and application of high m / z ion (> m / z 6000 and high mass, >150 kDa) formation, transmission, analysis, and detection is a relatively new area of focus for MS that has seen dramatic acceleration in interest over the last two decades. Herein we delve into this exciting aspect of MS, discussing how MS instrumentation has been refined and evolved for native-MS analysis. We cover the early groundbreaking experiments showing high m / z ion formation, transmission, and preservation of protein structure in the gas phase. Additionally, we discuss specific instrument optimizations and modifications that have advanced high m / z ion generation, transmission, analysis, and detection, contributing to the research area known as gas-phase structural biology. Native-MS sample introduction methods, emerging technologies, and future perspectives are also examined. Finally, we share personal opinions, observations, and experiences that are new to the community or previously unpublished.

collisions↗

PIONEER, a high-resolution single-crystal polarized neutron diffractometer

PIONEER is a high Q-resolution, single-crystal, polarized neutron diffractometer at the Second Target Station (STS), Oak Ridge National Laboratory. It will provide the unprecedented capability of measuring tiny crystals (0.001 mm 3 , i.e., x-ray diffraction size), ultra-thin films (10 nm thickness), and weak structural and magnetic transitions. PIONEER benefits from the increased peak brightness of STS cold-neutron sources and uses advanced Montel mirrors that are able to deliver a focused beam with a high brilliance transfer, a homogeneous profile, and a low background. Monte Carlo simulations suggest that the optimized instrument has a high theoretical peak brilliance of 2.9 × 10 12 n cm -2 sr -1 Å -1 s -1 at 2.5 Å at the sample position, within a 5 × 5 mm 2 region and a ±0.3° divergence range. The moderator-to-sample distance is 60 m, providing a nominal wavelength band of 4.3 Å with a wavelength resolution better than 0.2% in the wavelength range of 1.0–6.0 Å. PIONEER is capable of characterizing large-scale periodic structures up to 200 Å. With a sample-to-detector distance of 0.8 m, PIONEER accommodates various sample environments, including low/high temperature, high pressure, and high magnetic/electric field. Additionally, a large cylindrical detector array (4.0 sr) with a radial collimator is planned to suppress the background scattering from sample environments. Bottom detector banks provide an additional 0.4 sr coverage or can be removed if needed to accommodate special sample environments. We present virtual experimental results to demonstrate the scientific performance of PIONEER in measuring tiny samples.

47 OTHER INSTRUMENTATION↗

Site and endmember spectra of terrestrial vegetation and soils for the Colorado Headwaters Ecological Spectroscopy Study, June-July 2025

This dataset provides site and endmember spectra collected during the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS) campaign. The site spectra were collected to help validate airborne hyperspectral data acquired by the National Ecological Observatory Network's aerial observation platform (NEON AOP). Endmember spectra were collected to augment existing spectral libraries with additional samples of bare surfaces and non-photosynthetic vegetation. All measurements were acquired with an Analytical Spectral Devices (ASD) FieldSpec4 Hi-Res NG (Next Generation) spectroradiometer, which records radiance at 1nm (nanometer) intervals from the ultraviolet to the short-wave infrared (350-2500 nm). The dataset includes spectra measured at meadow sites where the CHESS team also collected vegetation samples for trait analyses. The site spectra were collected with the ASD FieldSpec4 palm grip attachment using an 8° field-of-view foreoptic. Site spectra are integrated measurements of the entire surface within the foreoptic’s field of view. For site-level spectra, the sun is the illumination source. A Spectralon panel mounted on a tripod was used for instrument optimization and white reference measurements for all site spectra. Site spectra were acquired within two hours of solar noon and within 48 hours of a NEON AOP overflight. Site spectra are labeled by date, sampling area, and site number according to the naming conventions of the CHESS campaign’s data management plan. The dataset also contains endmember spectra in the following categories: photosynthetic vegetation (PV), non-photosynthetic vegetation (NPV), bare (soil/rock), and flowers. Endmember measurements were acquired using either the contact probe or the leaf clip attachments of the ASD FieldSpec4. In these configurations, the bulb inside the spectrometer provides the light source for the measurements. The spectrometer was optimized and white reference measurements were recorded using the circular white pucks attached to the contact probe and leaf clip. Because they do not rely on solar illumination, contact probe and leaf clip measurements were collected during a broader time frame than the palm grip site spectra. Some endmembers were measured at CHESS meadow sites, while others were collected within the larger sampling area or in nearby locations (e.g. Gothic Townsite) with similar characteristics. Radiance, reflectance, and metadata files are split into three subfolders according to measurement type: proximal/palm grip (prx), contact probe (cp), and leaf clip (lc). Radiance spectra are provided in ASD file format (.asd file extension). All ASD files can be opened using the provided scripts. Metadata is provided in two formats: CSV file format (no geolocation) and GEOJSON file format (includes geolocation for each spectra). The dataset includes a set of pre-processed reflectance spectra as CSV files (yyyymmdd_rfl.csv). The python scripts and jupyter notebook used to calculate reflectance spectra from the ASD radiance data is included here and was previously published at: https://doi.org/10.3334/ORNLDAAC/2446. There is also a folder of JPEG photographs corresponding to selected spectra. We include a protocol document with detailed steps for ASD FieldSpec4 assembly and operations. This data additionally contains a file level metadata (flmd.csv) and data dictionary (dd.csv) file. Geospatial information: Geospatial data for mapping measurement site locations are in the files CHESS_polygons_lai_UTM.geojson, CHESS_polygons_shrub_UTM.geojson, and CHESS_polygons_meadow_UTM.geojson in the companion geospatial package for the 2025 CHESS campaign, ‘CHESS 2025: Location data for field observations and sampling’ (Henderson et al., 2026). CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgment: This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration (80NM0018D0004) and was funded by EMIT Extended Mission Phase E Science.

2018 NEON and 2025 CHESS Campaigns↗

Second Target Station Project: LANSCE WNR Target 2 (Blue Room) Experiment 2022

The Second Target Station (STS) at SNS will address emerging scientific challenges by providing a source of intense, cold neutrons to instruments optimized for this source, using rotating, tungsten target blocks. The STS target will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 108 beam pulses per lifetime. As an R&D activity, the LANSCE WNR Target 2 (blue room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60% of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. Both the LANSCE Proton Storage Ring (PSR) and SNS are short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in < 1 microsecond pulse duration.

43 PARTICLE ACCELERATORS↗