Engineering PapersSearch

SEARCH · Engineering Papers

Results for “In situ cleaning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

In situ sputter cleaning of thin film metal substrates for UHV-TEM corrosion studies.

A prerequisite for conducting valid corrosion experiments by in situ electron microscopy techniques is not only the achievement of UHV background pressure conditions at the site of the specimen but also the ability to clean the surface of the thin metal substrate specimen before initiation of the corrosive interaction. A miniaturized simple ion gun has been constructed for this purpose. The gun is small enough to be incorporated into an UHV electron microscope specimen chamber with hot stage in such a way as to permit bombardment of the substrate specimen while observing it by transmission electron microscopy TEM. It is shown that the ion beam generated is confined well enough to cause a sputtering removal of substrate material at a rate of approximately 5-10 A/min and to prevent the sputter deposition of contaminating material from the specimen holder.

Heinemann, K.

Statistical Decomposition and Machine Learning to Clean In Situ Spaceflight Magnetic Field Measurements

Robust in situ magnetic field measurements are critical to understanding the various mechanisms that couple mass, momentum, and energy throughout our solar system. However, the spacecraft on which magnetometers are often deployed contaminate the magnetic field measurements via onboard subsystems including reaction wheels and magnetorquers. Two magnetometers can be deployed at different distances from the spacecraft to determine an approximation of the interfering field for subsequent removal, but constant data streams from both magnetometers can be impractical due to power and telemetry limitations. Here we propose a method to identify and remove time-varying magnetic interference from sources such as reaction wheels using statistical decomposition and convolutional neural networks, providing high-fidelity magnetic field data even in cases where dual-sensor measurements are not constantly available. For example, a measurement interval from the Parker Solar Probe outboard magnetometer experienced a 95.1% reduction in reaction wheel interference following application of the proposed technique.

magnetic field data

Active cleaning technique for removing contamination from optical surfaces in space

An active cleaning technique for removing contaminants from optical surfaces in space was investigated with emphasis on the feasibility of using plasma exposure as a means of in-situ cleaning. The major work accomplished includes: (1) development of an in-situ reflectometer for use in conjunction with the contaminant film deposition/cleaning facility; (2) completion of Apollo Telescope Mount (ATM) filter treatment experiments to assess the effects of plasma exposure on the UV transmittance; (3) attempts to correlate the atomic oxygen flux with cleaning rate; (4) completion of in-situ butadien contamination/plasma cleaning/UV reflectance measurement experiments; (5) carbon cleaning experiments using various gases; (6) completion of silicone contamination/cleaning experiments; and (7) experiments conducted at low chamber pressures to determine cleaning rate distribution and contamination of surfaces adjacent to those being cleaned.

Shannon, R. L.

Ohmic Versus Rectifying Contacts of Au to N-gaas by Ion Sputtering

Results of investigations of argon ion sputtering of heavily doped n-GaAs are compared with those obtained from studies of Au/low doping density n-GaAs contacts. The Au contact on Si-doped GaAs was nearly ohmic when the surface contamination (carbon and oxides) was reduced prior to deposition by chemical cleaning. However, when ion sputtering was used in situ to clean the surface, rectifying contact was produced whose barrier height varied with the energy of the sputtering ion. It was found that ion sputtering of GaAs doped to more than 3 x 10 to the 18th power/cu may be used to change ohmic contact to rectifying contacts. The barrier height may be changed by changing the ion energy. The behavior results from the sputter creation of deep level acceptor states at the GaAs surface. Annealing after sputtering can restore the contact to nearly an ohmic character.

Wang, Y. X.

NOVEL METHODS FOR IN SITU HIGH DENSITY SURFACE CLEANING SCRUBBING OF ULTRAHIGH VAC LONG NARROW TUBES TO REDUCE SECONDARY ELECTRON YIELD AND OUT GASSING

This project developed new methods for cleaning the inside surfaces of very long, narrow vacuum tubes used in particle accelerators. Traditional cleaning approaches are expensive, slow, or difficult to implement in accelerator tunnels. We designed and tested a portable plasma discharge cleaning system that uses lower-cost microwave and magnetron technologies to reduce outgassing and secondary electron emission from stainless steel and copper surfaces. The system, called the Plasma Discharge Test System (PDTS), allows accelerator components to be scrubbed more efficiently, which can improve performance and reduce maintenance costs for research and industrial applications.

POOLE, JOE HENRY [PRESIDENT]

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER

X-ray photoelectron spectroscopic study of the oxide removal mechanism of GaAs /100/ molecular beam epitaxial substrates in in situ heating

A standard cleaning procedure for GaAs (100) molecular beam epitaxial (MBE) substrates is a chemical treatment with a solution of H2SO4/H2O2/H2O, followed by in situ heating prior to MBE growth. X-ray photoelectron spectroscopic (XPS) studies of the surface following the chemical treatment show that the oxidized As is primarily As(+ 5). Upon heating to low temperatures (less than (350 C) the As(+ 5) oxidizes the substrate to form Ga2O3 and elemental As, and the As(+ 5) is reduced to As(+ 3) in the process. At higher temperatures (500 C), the As(+ 3) and elemental As desorb, while the Ga(+ 3) begins desorbing at about 600 C.

Vasquez, R. P.

Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation

The University of Kentucky (UKy) project titled “Ash Fouling Free Regenerative Air Preheater for Deep Cyclic Operation”, DE-FE0031757, was conducted from 8/15/2019 to 8/14/2024 in two Budget Periods. Other participants included PPL Corporation and Black Dragon Double Boiler. The overall goal was to investigate the proposed self-cleaning technology to achieve ash fouling free air preheater operation in a coal-fired power plant, especially during deep cycling. All project deliverables, milestones, and success criteria were met. UKy obtained the following scientific findings. • Temporary and periodic high temperature of heating elements (450 ~ 500 °F) can prevent ash accumulation and maintain air preheater free of clogging. • The ash samples analysis and unit operation provide solid evidence of ABS formed during low load with SCR ammonia slip being the major cause of ash accumulation, and air preheater clogging can be prevented by raising the heating element temperature up to 450 °F~ 500 °F at which ABS is decomposed. • In-situ self-cleaning can be controlled by monitoring temperature and/or presetting fixed number of cleanings per day. Both approaches in pilot testing show positive results for maintaining an ash free state for the air preheater. • Temperature criteria (cold end or gas outlet temperature) for entering self-cleaning service is critical to balance the number of cleaning cycles with maintaining the ash level. • Temperature criteria (cold end or gas outlet temperature) for exiting self-cleaning service is critical to balance the duration of the cleaning cycles with maintaining the ash level.

01 COAL, LIGNITE, AND PEAT

Optical coating in space

A technological appraisal of the steps required to approach the goal of in-situ optical coating, cleaning and re-coating the optical elements of a remote telescope in space is reported. Emphasis is placed on the high ultraviolet throughput that a telescope using bare aluminum mirrors would offer. A preliminary design is suggested for an Orbital Coating Laboratory to answer basic technical questions.

Bunner, A. N.

YBa2Cu3O(7-x)/Au/Nb device structures

Fabrication and testing of planar and edge geometry YBaCuO/Au/Nb superconductor/normal-metal/superconductor (SNS) device structures is described. Weak-link devices of this type serve as sensitive probes of the electrical quality of the YBaCuO/Au interface. The devices are fabricated using laser-ablated, in situ, c-axis-oriented YBaCuO thin films, with both annealed and unannealed YBaCuO/Au interfaces. The planar SNS structures are formed by sequential, in situ deposition of YBaCuO, Au, and Nb, followed by etching, planarization, and wiring electrode definition to produce junctions ranging from 5 to 20 micron on a side. Resulting RnA products are 1-10 x 10 to the -8th ohm-sq cm with critical current densities up to 5 kA/sq cm. For the edge geometry devices, the YBaCuO film edges are patterned using Ar ion milling, followed by a low energy ion cleaning step and in situ deposition of Au and Nb. Devices with areas in the 10 to the -7th to 10 to the -8th sq cm range have been fabricated with RnA products lower than 10 to the -8th ohm-sq cm and critical current densities up to 3kA/sq cm. Both types of devices show ac Josephson steps under microwave irradiation. The best results have been obtained with annealed YBaCuO/Au interfaces.

Hunt, B. D.

Testing of spark plasma sintered porous tungsten under neon glow discharge cleaning conditions in LTX-β

This paper demonstrates that tungsten (W) based powder reconstituted Plasma Facing Components (PFCs) can be treated in situ in a fusion reactor to remove W oxide and carbon (C) contamination. Doing so should ease the challenge of using these materials in a Capillary Porous System (CPS) with lithium (Li) by enabling better wetting and less contamination of the Li by the underlying CPS. Most powder reconstituted materials including 3D printed and sintered PFCs suffer from a high surface contamination from oxides and surface C, which complicates their use with liquid Li, a primary PFC candidate. Spark plasma sintered porous W samples were fabricated to be used as a CPS with liquid Li. The samples were characterized in terms of morphology and surface chemistry. Analysis confirms a high C and oxygen (O) contamination. We present the results of exposing this type of CPS to Glow Discharge Cleaning (GDC) cycles in the Lithium Tokamak Experiment-β (LTX-β). The sample was exposed to neon (Ne) GDC in the midplane of the low-field side of LTX-β and analyzed in vacuo with Temperature Programmed Desorption (TPD) and Secondary Ion Mass Spectrometry (SIMS) to investigate the effects the Ne GDC had on the chemical composition of the sample. The combination of Ne GDC with rapid heating as done in TPD was successful in reducing the W oxides and removing the C contamination.

Capillary porous system

Deposition of adherent Ag-Ti duplex films on ceramics in a multiple-cathode sputter deposition system

The adhesion of Ag films deposited on oxide ceramics can be increased by first depositing intermediate films of active metals such as Ti. Such duplex coatings can be fabricated in a widely used three target sputter deposition system. It is shown here that the beneficial effect of the intermediate Ti film can be defeated by commonly used in situ target and substrate sputter cleaning procedures which result in Ag under the Ti. Auger electron spectroscopy and wear testing of the coatings are used to develop a cleaning strategy resulting in an adherent film system.

Honecy, Frank S.

Ultrashort Pulsed Laser Treatment: A Novel Sterilization Method for Planetary Protection

Introduction: On missions seeking signs of potential life elsewhere in the solar system, we have an obligation not to bring our own Earthly life with us. Reducing the bioburden (number of living microbes) on spacecraft is therefore required by the COSPAR Policy on Planetary Protection to target bodies that are of interest for understanding the origins of life (such as Mars). The method of spacecraft sterilization predominantly used by NASA is Heat Microbial Reduction, which is typically incompatible with heat-sensitive components such as optics and electronics, and is expensive and time-consuming. Here, we present preliminary results on a novel method for spacecraft hardware sterilization: high-intensity ultrashort (femtosecond) pulsed laser illumination. Femtosecond lasers use extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. This rapid sterilization technique could be carried out in situ in a spacecraft assembly clean room using high-speed surface scanning, saving critical time and resources. It also can potentially remove or reduce debris from inactivated cells and spores. Methods: To develop optimal laser processing parameters for inactivating planetary protection-relevant organisms on metal surfaces, we inoculated 1-cm^2 mirror-polished aluminum coupons with Bacillus subtilis spores (2x10^5 spores/coupon) and tested the effect of several parameters, including pulse count and fluence. Sterilization effectiveness was measured by recovering spores using a PVA (polyvinyl acetate) peel and conducting serial dilution and plating for colony-forming units (CFUs). Results: Our results show that pulse count and fluence both affect sterilization effectiveness and that within a certain pulse count range, increasing fluence increases effectiveness. We have demonstrated the ability to reduce viable microbial counts by at least 10^-4. Future work will include testing higher abundances and different species of microorganisms, effectiveness on complex surfaces, compatibility with sensitive surfaces, and quantification of cell debris removal. Femtosecond pulsed laser illumination has the potential to provide dramatic savings in both cost and schedule over current methods of bioburden reduction to prevent forward contamination. It may also have the potential for use in surface sterilization of returned samples to prevent back contamination.

Planetary Protection; Lasers; Sterilization; Bacil

Spatial and Temporal Variability of Ground and Satellite Column Measurements of NO2 and O3 over the Atlantic Ocean During the Deposition of Atmospheric Nitrogen to Coastal Ecosystems Experiment

In situ measurements of O3 and nitrogen oxides (NO + NO2=NOx) and remote sensing measurements of total column NO2 and O3 were collected on a ship in the North Atlantic Ocean as part of the Deposition of Atmospheric Nitrogen to Coastal Ecosystems (DANCE) campaign in July August 2014,100 km east of the mid-Atlantic United States. Relatively clean conditions for both surface in situ mixing ratio and total column O3 and NO2 measurements were observed throughout the campaign. Increased surface and column NO2 and O3 amounts were observed when a terrestrial air mass was advected over the study region. Relative to ship-based total column measurements using a Pandora over the entire study, satellite measurements overestimated total column NO2 under these relatively clean atmospheric conditions over offshore waters by an average of 16. Differences are most likely due to proximity, or lack thereof, to surface emissions; spatial averaging due to the field of view of the satellite instrument; and the lack of sensitivity of satellite measurements to the surface concentrations of pollutants. Total column O3 measurements from the shipboard Pandora showed good correlation with the satellite measurements(r 0.96), but satellite measurements were 3 systematically higher than the ship measurements, in agreement with previous studies. Derived values of boundary layer height using the surface in situ and total column measurements of NO2 are much lower than modeled and satellite-retrieved boundary layer heights, which highlight the differences in the vertical distribution between terrestrial and marine environments.

Martins, Douglas K.

Hydrogen-terminated silicon substrates for low-temperature molecular beam epitaxy

The preparation of hydrogen-terminated silicon surfaces for use as starting substrates for low-temperature MBE growth is examined in detail. The procedure involves the ex situ removal under nitrogen of residual oxide from a silicon substrate using a spin-clean with HF in ethanol, followed by the in situ low-temperature desorption (150 C) of physisorbed etch residues. The critical steps and the chemical basis for these steps are examined using X-ray photoelectron spectroscopy. Impurity residues at the epilayer-substrate interface following subsequent homoepitaxial growth are studied using AES, SIMS and TEM. Finally, scanning tunneling microscopy is used to examine the effect of cleaning methods on substrate morphology.

Grunthaner, P. J.

Polycrystalline silicon on tungsten substrates

Thin films of electron-beam-vaporized silicon were deposited on fine-grained tungsten substrates under a pressure of about 1 x 10 to the -10th torr. Mass spectra from a quadrupole residual-gas analyzer were used to determine the partial pressure of 13 residual gases during each processing step. During separate silicon depositions, the atomically clean substrates were maintained at various temperatures between 400 and 780 C, and deposition rates were between 20 and 630 A min. Surface contamination and interdiffusion were monitored by in situ Auger electron spectrometry before and after cleaning, deposition, and annealing. Auger depth profiling, X-ray analysis, and SEM in the topographic and channeling modes were utilized to characterize the samples with respect to silicon-metal interface, interdiffusion, silicide formation, and grain size of silicon. The onset of silicide formation was found to occur at approximately 625 C. Above this temperature tungsten silicides were formed at a rate faster than the silicon deposition. Fine-grain silicon films were obtained at lower temperatures.

Bevolo, A. J.

Particulate Removal Using a CO2 Composite Spray Cleaning System

The Planetary Protection surface cleanliness requirements for potential Mars Sample Return hardware that would come in contact with Martian samples may be stricter than previous missions. The Jet Propulsion Laboratory has developed a new technology that will enable us to remove sub-micron size particles from critical hardware surfaces. A hand-held CO2 composite cleaning system was tested to verify its cleaning capabilities. This convenient, portable device can be used in cleanrooms for cleaning after rework or during spacecraft integration and assembly. It is environmentally safe and easy to use. This cleaning concept has the potential to be further developed into a robotic cleaning device on a Mars Lander to be used to clean sample acquisition or sample handling devices in situ. Contaminants of known sizes and concentrations, such as fluorescent microspheres and spores were deposited on common spacecraft material surfaces. The cleaning efficiency results will be presented and discussed.

carbon dioxide