Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Imperfect thermal contact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A variational mimetic finite difference method for elliptic interface problems on non-matching polytopal meshes with geometric interface inconsistencies

A new variational mimetic finite difference method for elliptic interface problems with perfect and imperfect thermal contacts on non-matching polytopal meshes with geometric interface inconsistencies is developed and analyzed theoretically and numerically. The method is defined on multiple non-matching submeshes with gaps and overlaps along their interfaces. The discrete equations are derived from a minimization problem for the augmented Dirichlet functional. For a perfect thermal contact, the functional uses a modified mimetic gradient with extended stencil which couples unknowns from both sides of an interface, as well as penalty terms to enforce weak continuity of temperature across the interface. The method leads to a symmetric positive definite matrix for any scaling of the penalty terms. For an imperfect thermal contact, the Dirichlet functional is supplemented with a quadratic jump term along the interface related to the interface thermal resistance. We prove that the method conserves the total heat flux across each interface. In conclusion, the obtained results are verified with numerical experiments showing convergence in the discrete L 2 and L ∞ norms.

97 MATHEMATICS AND COMPUTING↗

Theoretical Analysis of a Pulse Tube Regenerator

A theoretical analysis of the behavior of a typical pulse tube regenerator has been carried out. Assuming simple sinusoidal oscillations, the static and oscillatory pressures, velocities and temperatures have been determined for a model that includes a compressible gas and imperfect thermal contact between the gas and the regenerator matrix. For realistic material parameters, the analysis reveals that the pressure and, velocity oscillations are largely independent of details of the thermal contact between the gas and the solid matrix. Only the temperature oscillations depend on this contact. Suggestions for optimizing the design of a regenerator are given.

Roach, Pat R.↗

Low-cost, Highly Efficient and Fast Thermally Pressed Scalable Carbon-based Planar Perovskite Solar Cells

This Final Technical Report summarizes work completed under Award Number DEEE0009833, titled "Low-cost, Highly Efficient and Fast Thermally Pressed Scalable Carbon-based Planar Perovskite Solar Cells." The project addressed the central technical problem that carbon-electrode perovskite solar cells (C-PSCs) can reduce electrode costs and improve environmental durability, but they have historically lagged noble-metalcontact devices due to poor carbon/perovskite contact, high carbon-electrode resistance, imperfect hole extraction, and insufficient operational stability. The Statement of Project Objectives (SOPO), therefore, required systematic engineering of thermally pressed carbon-based planar perovskite solar cells by improving the carbon/perovskite interface quality, improving carbon-electrode conductivity, and further increasing device stability. The work advanced understanding of carbon-based perovskite photovoltaics by connecting device performance to three coupled mechanisms: interfacial recombination at the perovskite/hole-transport-layer/carbon stack; lateral and vertical transport losses in carbon contacts; and instability driven by moisture, heat, illumination, ion migration, and slow/variable manufacturing steps.

14 SOLAR ENERGY↗

Developing Procedures to Implement Geometric Imperfections Beyond Right Circular Cylindrical Shells in Finite Element Method Models

Analysis of aerospace structures is frequently conducted using nominal dimensions and frequently assumes ideal conditions in loading, contact, constraints, et cetera. Off-nominal dimensions and nonideal conditions, however, are present in all structures. These are the result of widely ranging causes from coefficient of thermal expansion mismatches, manufacturing tooling anomalies, to assembly procedures that inadvertently alter the structure. Specifically, geometric imperfections can have potentially significant influence on the response of a structural test article observed in an experiment versus the response given by a numerical simulation. The Python Tool for Implementing Geometric Imperfections in Reduced Structures (Py_TIGIRS) was previously presented as a set of Python scripts to calculate and implement as-manufactured geometric midsurface and thickness imperfections into finite element method (FEM) shell models of nominally right circular cylinders. By taking advantage of the simple shape of a right circular cylinder, interpolations of the measured data points were able to be performed along directions that aligned to the cylindrical coordinate system axes of the entire structure. By taking advantage of the shell representation of the real structure as opposed to modeling using a continuum representation, the thickness variation was able to be implemented by shell section definitions instead of having to modify the position of multiple nodes in the thickness direction. Py_TIGIRS is a useful tool that established a procedural example on how to implement geometric imperfections in right circular cylindrical shell structures. Three new procedures, each expanded from concepts established in Py_TIGIRS, are proposed for various test-article designs and are intended to broaden the range of structures that can be modeled with measured geometric imperfections in the structural analysis community. Each test-article design introduces new challenges to successfully implement geometric imperfections into a FEM model. The first test-article design consists of a carbon fiber reinforced polymer square plate with a hat-shaped stiffener co-cured on one side. This test-article design was for a novel seven-point bend test that was also previously presented. Manufacturing and cure-cycle imperfections are observed using digital image correlation (DIC) techniques. As thermal expansion coefficient mismatches between the plate and stiffener materials were anticipated, a thermal analysis study with continuum shell and solid elements was conducted to capture the global shape observed prior to testing. The second test-article design is of a similar hat-stiffened plate configuration, but with a side length ratio near 3:1 with elongation in the stiffener direction. The test article was used to characterize the response to uniaxial compressive loading in the direction of the stiffener. Due to differing manufacturing steps, a thermal analysis like the one developed for the seven-point bend configuration was unable to mimic the observed geometric imperfections. Instead, a strategy based on applying deformations directly to the structure during analysis was developed for continuum shell and solid element representation of a stiffened panel.

Geometric imperfections↗

The dynamic characteristics of a turbo-rotor simulator supported on gas-lubricated foil bearings. Part 2: Operation with heating and thermal gradients

A high speed rotor, supported by gas-lubricated foil bearings, is free from self-excited whirl and displays no loss of load capacity when vibrated at frequency equal to the rotational speed. It is demonstrated that in addition to tolerance of geometrical imperfections, misalignment and foreign particles, the foil bearing performs well at elevated temperatures and accommodates appreciable temperature gradients. The foil bearing is endowed with superior wipe-wear characteristics and the flexibility of the foil accounts not only for the stability of the foil bearing, but also for its accommodation of, and compensation for, distortion, contamination, and contact.

Licht, L.↗

Low Leakage Valves for Long Duration Missions

I.Nomenclaturemtypical_mission=internal mass of propellant lost over the course of a mission with Qtypicalmmission_goal=mass of propellant loss over the course of a mission with Qgoaltmission=theoretical mission durationQtypical=internal leakage rate found in commercially available valvesQgoal=internal leakage rate design goalρH2_STP=density of hydrogen at standard temperature and pressure.1NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)2NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)3NASA AST, Liquid Propulsion Valve Engineer (Retired).Valves, Actuators, and Ducts Design and Development Branch (ER14)4JSEG ESSCA, Engineering Specialist.Valves Actuators and Ducts Design and Development Branch (ER14)5NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)6JSEG ESSCA, Valve Design and Development Engineer.Valves Actuators and Ducts Design and Development Branch (ER14) II.IntroductionCurrent aerospace cryogenic valves present challenges to potential long duration missions that utilize cryogenic propellants. Small interplanetary and long-life communication satellites typically utilize hypergolic propellants that operate at higher temperatures, making it easier to achieve very low internal leakage rates. Larger vehicles for long duration missions will likely need to utilize cryogenic-based chemical and nuclear systems to achieve mission requirements. Some early propulsion concepts are projected to require valves with a nominal size ranging from 3” to 10”.Currently available cryogenic aerospace valves typically have internal leakage rates which can range from 100 to 300 SCIM for 3” valves, or upwards of 2,000 SCIM for 10” valves. With just a few of these valves in a system, internal leakage could account for multiple tons of propellant loss over the course of a potential Mars mission, as shown in Figure 1.Figure 1 - Potential Propellant Loss Over the Course of a Long Duration MissionMost internal leakage rates can be attributed to inherent imperfections and misalignments, which result in imperfect contact between sealing surfaces, as shown in Figure 2.Figure 2 - Imperfections and Misalignments Between Sealing Surfaces The ER14 Branch at Marshall Space Flight Center (MSFC) has created a self-aligning seat and poppet design (shown in Figure 3) that allows a valve to be more tolerant of imperfect contacts. This design utilizes a metallic poppet head with five degrees of freedom that allows the poppet toself-align with the seat, reducing the need for tight tolerances.Figure 3 - Self-Aligning Seat and Poppet DesignIII.Test Valve DescriptionA series of development tasks have been conducted to study potential improvements to internal leakage rates. These tasks include 3 test valves (shown in Figure 4) to demonstrate the potential application to various configurations and sizes:A 3” isolation valve for liquid flows (similar to a fill and drain valve)A 3” relief valve for low temperature gas flows.An 8” pre-valve (similar to the engine isolation valve needed on a Nuclear Thermal Propulsion (NTP) engine).Figure 4 - Low Leakage Development Test ValvesThese valves have been developed and are currently being tested at liquid nitrogen (LN2) temperatures, and are anticipated to undergo testing at liquid hydrogen (LH2) temperatures in late 2022

Cody L Gilliland↗

Detection and Characterization of Imperfections in Composite Pressure Vessels

The thermographic evaluation of composite structures for delaminations, disbonds, inclusions, porosity and microcracking has proven to be a valuable asset in the field of nondestructive testing. Coupling large area coverage, variable sensitivity and minimal surface contact with a photographic type image representation of structural anomalies; thermography has become a primary inspection method for composite structures. Thermography works well for locating both surface and subsurface defects in most composite systems ranging in thickness of up to 0.25 inch (0.64 cm) or more. The thermographic method for inspection of composite structures typically involves applying an external source of heat to the structure and then recording the changes in the surface heat profile manifested by embedded defects or by material property variations. If these temperature variations are large enough and an infrared camera with sufficient sensitivity is used, then the material or structural abnormality can be detected and referred back to its source. Interpreting the information given in a thermogram, can be a difficult task under ideal circumstances and extremely challenging in a real world setting. Variables including depth, thermal conductivity, orientation and size of the abnormality can all have a great influence on how its heat pattern will be seen by the imager. The work discussed in this paper illustrates how the microstructure of several commonly found defects in composite structures relate to their thermographic image counterpart. Two test cases are studied herein, including a large graphite/epoxy RP-1 fuel tank and a graphite composite cryogenic fuel feedline. The structures used in this study were designed to serve as manufacturing proof of concept specimens and to undergo hydroburst testing to verify manufacturing practices and structural design. Prior to hydrostatic testing the structures underwent 100% thermographic evaluation to ensure that no manufacturing or handling damage was present. Due to a large inclusion found in the feedline, it was pulled from service and dissected without performing the hydroproof The thermographic indications found in the RP-1 tank were below critical limits so it underwent a complete hydroproof loading series and finally a hydroburst. Following the hydroburst samples were cut from the tank in regions where thermography had located damage before the test. These regions were thermographically and then were cross-sectioned and photomicrographed.

Walker, James L.↗