Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Imaging probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Single-shot imaging with randomized structured illumination at a free electron laser

Stroboscopic nanoscale imaging with free electron laser light is revolutionizing our understanding of fast dynamics in heterogeneous systems. The short wavelength of X-ray and extreme ultraviolet radiation makes it possible to achieve nanoscale resolution, while resonance with atomic transitions gives access to electronic and magnetic degrees of freedom. Here, we report on our implementation of a recently developed imaging method, randomized probe imaging, at a free electron laser. The advantage of randomized probe imaging over existing methods is its compatibility with extended and strongly scattering samples. Our implementation delivers robust single-shot reconstructions at up to a full-pitch resolution of 400 nm over a field of view with a 40 µm diameter. We also demonstrate single-shot imaging of magnetic domain structures using circular dichroism at resonance, paving the way to future time-resolved studies of magnetic dynamics, shock physics, and the dynamics of collective electronic phases.

47 OTHER INSTRUMENTATION

Sub-10 nm upconversion nanocrystals for long-term single-particle tracking

Lanthanide-doped upconversion nanoparticles are attractive single-molecule imaging probes due to their high photostability and anti-Stokes luminescence. However, achieving both small particle size and strong brightness has remained a major challenge, as reducing size often leads to dimmer emission. Herein, we fabricate a sub-10 nm cascade actively protected upconversion nanoparticles, which shows a 33-fold enhanced upconversion efficiency at the single-particle level compared to larger ~19 nm conventional nanoparticles. Theoretical modeling and time-resolved measurements show that emission loss mainly comes from energy leakage of Er 3+ ions to surface defects. By introducing a NaYbF 4 layer as photon-harvesting and protective intermediate layer, we minimize this energy loss and significantly boost brightness. A monolayer of inert NaLuF 4 can effectively suppress the surface quenching to Yb 3+ . Using these ultra-small bright probes, we successfully tracked single epidermal growth factor receptor molecules on live cells for up to one hour, revealing dynamic switching between different diffusion modes.

Qiu, Xiaochen [Fudan Univ., Shanghai (China); Shen

Kelvin Probe Force Microscopy Imaging of Plasticity in Hydrogenated Perovskite Nickelate Multilevel Neuromorphic Devices

Ion drift in nanoscale electronically inhomogeneous semiconductors is among the most important mechanisms being studied for designing neuromorphic computing hardware. However, nondestructive imaging of the ion drift in operando devices directly responsible for multiresistance states and synaptic memory represents a formidable challenge. Here, we present Kelvin probe force microscopy imaging of hydrogen-doped perovskite nickelate device channels subject to high-speed electric field pulses to directly visualize proton distribution by monitoring surface potential changes spatially, which is also supported with finite element-based electric field distribution studies. First-principles calculations provide mechanistic insights into the origin of surface potential changes as a function of hydrogen donor doping that serves as the contrast mechanism. We demonstrate 128 (7-bit) nonvolatile conductance levels in such devices relevant to in-memory computing applications. The synaptic plasticity measurements are implemented in spiking neural networks and show promising results for classification (SciKit Learn’s Iris and Wine data sets) and control (OpenAI’s CartPole-v1 and BipedalWalker-v3) simulation tasks.

Kelvin probe force microscopy

Composition, Growth, Succession, and Function in the Cladophora Microbiome: Insights From Quantitative Stable Isotope Probing and NanoSIMS Imaging

The branching green macroalga Cladophora glomerata and its epiphytic microbiome dominate summer biomass in the Eel River, a Northern California river under Mediterranean (summer drought, winter rain) seasonality. Green Cladophora streamers proliferate in early summer, then change to yellow and then red-brown as epiphyte loads increase. Here, we characterised successional changes in epiphytic bacteria on Cladophora, examining both community composition and growth rates, using quantitative Stable Isotope Probing (qSIP) and 16S rRNA gene amplicon sequencing. The number of bacterial taxa increased with succession while growth rates peaked in the middle stage. NanoSIMS imaging confirmed high sulphur (S) concentrations in Cladophora cell walls relative to surrounding biomass, coinciding with a bloom of sulphur bacteria (bacteria that reduce or oxidise sulphur/sulphates). In general, relative abundances and growth rates were independent, indicating that either metric alone is insufficient for understanding how taxonomy and functional groups affect ecosystem processes. For instance, the relative abundance of nitrogen fixers peaked in the late summer when their relative growth rates were slowest. Such patterns may be driven by space competition limiting growth. Together, changes in abundance and relative growth rates suggest different limiting factors for different functional groups in the Cladophora microbiome at multiple successional stages.

Biological and medical sciences

Optical imaging of flavor order in flat band graphene

Abstract Spin- and valley flavor polarization plays a central role in the many-body physics of flat band graphene, with Fermi surface reconstruction — often accompanied by quantized anomalous Hall and superconducting state — observed in a variety of experimental systems. Here we describe an optical technique that sensitively and selectively detects flavor textures via the exciton response of a proximal transition metal dichalcogenide layer. Through a systematic study of rhombohedral and rotationally faulted graphene bilayers and trilayers, we show that when the semiconducting dichalcogenide is in direct contact with the graphene, the exciton response is most sensitive to the large momentum rearrangement of the Fermi surface, providing information that is distinct from and complementary to electrical compressibility measurements. The wide-field imaging capability of optical probes allows us to obtain spatial maps of flavor order with high throughput, and with broad temperature and device compatibility. Our work helps pave the way for optical probing and imaging of flavor orders in flat band graphene systems.

Science & Technology - Other Topics

Ultrafast nano-imaging and nano-spectroscopy

Ultrafast pump–probe nano-imaging combines scanning probe-based optical near-field microscopy with ultrafast spectroscopy to enable imaging with deep sub-wavelength spatial resolution, femtosecond temporal resolution and simultaneous spectral resolution. Ultrafast nano-imaging has gained increased attention for its ability to provide far-from-equilibrium excitation and excited-state contrast. With coherent and nonlinear probing, coupled electron, spin and lattice dynamics on elementary timescale and length scale can be resolved. Through nano-movies, ultrafast nano-imaging visualizes correlated quantum dynamics underlying the properties of solid-state materials, semiconductors, molecular electronic, photonic, photovoltaic and other functional materials. With nanometre spatial resolution, this method probes elementary dynamic processes across multiple length scales that are otherwise obscured in conventional ultrafast spectroscopy in which heterogeneities are spatially averaged. Furthermore, this Primer describes the theoretical background and experimental implementation of ultrafast nano-imaging; signal interpretation and modelling; representative examples and a perspective for the future development of the field.

Microscopy

Evaluation of accuracy and resolution of the electron beam profile scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges.For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a YAG screen and an optical transition radiation (OTR) screen. Additionally, the point spread function (PSF) will be calculated to characterize the optical system's properties using ZEMAX software. The capabilities of the Hamamatsu Charge-Injection Device (CID) camera and Kimball Physics electron gun (e-gun) will be considered for accuracy.

Mwaniki, Matilda [IIT, Chicago; Fermilab]

The influence of laser power modulation on melt pool dynamics in laser powder bed fusion

While the majority of laser powder bed fusion (LPBF) metal additive manufacturing uses a continuous wave (CW) laser heat source, some commercial applications of LPBF additive manufacturing instead involve the modulation of the laser power on tens-of-microsecond timescales as an adjustable process variable. This article reports the use of in situ, high speed x-ray and optical imaging to probe melt pool fluid flow, defect formation, and nearby powder motion during LPBF with both modulated and CW laser heat sources. We observe melt pool dynamics unique to modulated laser melting even at very high duty cycles that are related to fluctuations in vapor depression depth, complex pore formation mechanisms, and changes to denudation physics when compared to CW melting. These behaviors are present in Ti–6Al–4V, 316L stainless steel, and AL1100 alloys but vary slightly as a function of material, indicating a substantial dependence on the viscosity and surface tension of the liquid metal. While high duty cycles produce weld tracks of comparable quality to CW melting, lower duty cycles introduce substantial defect concentrations. At intermediate duty cycles, careful control of modulation parameters can repeatably and precisely yield one pore per laser pulse, suggesting a method for intentionally inserting engineered porosity at specific sites during an LPBF build.

3D printing

Cell-Free Gene Expression: Methods and Applications

Cell-free gene expression (CFE) systems empower synthetic biologists to build biological molecules and processes outside of living intact cells. The foundational principle is that precise, complex biomolecular transformations can be conducted in purified enzyme or crude cell lysate systems. This concept circumvents mechanisms that have evolved to facilitate species survival, bypasses limitations on molecular transport across the cell wall, and provides a significant departure from traditional, cell-based processes that rely on microscopic cellular “reactors.” In addition, cell-free systems are inherently distributable through freeze-drying, which allows simple distribution before rehydration at the point-of-use. Furthermore, as cell-free systems are nonliving, they provide built-in safeguards for biocontainment without the constraints attendant on genetically modified organisms. These features have led to a significant increase in the development and use of CFE systems over the past two decades. Here, we discuss recent advances in CFE systems and highlight how they are transforming efforts to build cells, control genetic networks, and manufacture biobased products.

59 BASIC BIOLOGICAL SCIENCES

Rational Modulation of Plant Root Development Using Engineered Cytokinin Regulators

Achieving precise control over quantitative developmental phenotypes is a key objective in plant biology. Recent advances in synthetic biology have enabled tools to reprogram entire developmental pathways; however, the complexity of designing synthetic genetic programs and the inherent interactions between various signaling processes remains a critical challenge. Here, we leverage Type-B response regulators to modulate the expression of genes involved in cytokinin-dependent growth and development processes. We rationally engineered these regulators to modulate their transcriptional activity (i.e., repression or activation) and potency while reducing their sensitivity to cytokinin. By localizing the expression of these engineered transcription factors using tissue-specific promoters, we can predictably tune cytokinin-regulated traits. As a proof of principle, we deployed this synthetic system in Arabidopsis thaliana to either decrease or increase the number of lateral roots. The simplicity and modularity of our approach makes it an ideal system for controlling other developmental phenotypes of agronomic interest in plants.

Cell signaling

Horizon-scale variability of M87* from 2017–2021 EHT observations

Here, we report three epochs of polarized images of M87* at 230 GHz using data from the Event Horizon Telescope (EHT) taken in 2017, 2018, and 2021. The baseline coverage of the 2021 observations is significantly improved through the addition of two new EHT stations: the 12 m Kitt Peak Telescope and the Northern Extended Millimetre Array (NOEMA). All observations result in images dominated by a bright, asymmetric ring with a persistent diameter of 43.9 ± 0.6 µas, consistent with expectations for lensed synchrotron emission encircling the apparent shadow of a supermassive black hole. We find that the total intensity and linear polarization of M87* vary significantly across the three epochs. Specifically, the azimuthal brightness distribution of the total intensity images varies from year to year, as expected for a stochastic accretion flow. However, despite a gamma-ray flare erupting in M87 quasi-contemporaneously to the 2018 observations, the 2018 and 2021 images look remarkably similar. The resolved linear polarization fractions in 2018 and 2021 peak at ∼5%, compared to ∼15% in 2017. The spiral polarization pattern on the ring also varies from year to year, including a change in the electric vector position angle helicity in 2021 that could reflect changes in the magnetized accretion flow or an external Faraday screen. The improved 2021 coverage also provides the first EHT constraints on jet emission outside the ring, on scales of ≲ 1 mas. Overall, these observations provide strong proof of the reliability of the EHT images and probe the dynamic properties of the horizon-scale accretion flow surrounding M87*.

accretion, accretion disks

Neutron Scattering in High Magnetic Fields: Community Recommendations to Seize the Moment for Scientific Breakthroughs

Oak Ridge National Laboratory (ORNL) operates the world’s two most powerful neutron sources: the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS). These form a national user facility that provides neutron scattering instruments to probe and image static and dynamic properties of materials down to the atomic scale. Because the neutron carries a magnetic moment and the energies and wavelengths of neutrons match energy and length scales associated with magnetic materials, these facilities provide unique sensitivity to magnetism.

36 MATERIALS SCIENCE

Accuracy and Resolution Evaluation of the E-Beam Profile Scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges. For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a phosphor screen and an optical transition radiation (OTR) screen. The capabilities of the Kimball Physics electron gun (eGun) will be considered for accuracy. Additionally, the Zemax software will be utilized to characterize the optical elements.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics

The Interstellar Mapping And Acceleration Probe High Energy (IMAP-Hi) Neutral Atom Imager

The IMAP-Hi Energetic Neutral Atom (ENA) Imager on NASA’s Interstellar Mapping and Acceleration Probe (IMAP) mission (McComas et al. 2018a, 2025) is designed to measure ENAs from the global interaction between the heliosphere and the local interstellar medium (LISM). These ENAs are initially plasma ions of solar wind origin that are neutralized by charge exchange with the cold neutral atoms of LISM that freely flow through the heliosphere-LISM interaction region. IMAP-Hi consists of two identical single-pixel sensors, each covering the ENA spectral range from 0.44 keV to 15.6 keV over nine contiguous energy passbands and having an approximately conical field-of-view (FOV) of 4.1o full width at half maximum (FWHM). The Hi-45 sensor points 45o relative to the spacecraft spin axis from the antisunward direction; each spacecraft spin, it measures ENA intensity over a circular swath with half-cone angle 45o centered on the ecliptic plane. The Hi-90 sensor points 90o relative to the spin axis; each spacecraft spin, it measures ENA intensity over a great circle in the sky, sampling both the north and south ecliptic poles. As the IMAP spin vector is re-pointed daily toward the Sun, the ecliptic longitude of the swaths moves daily by ∼1o such that a full sky map is acquired by Hi-90 every six months and a complete low latitude (−45o to +45o) map is acquired by Hi-45 annually. The IMAP-Hi sensor design has direct heritage from the IBEX-Hi imager on the Interstellar Boundary Explorer (IBEX) mission, with substantial improvements in energy range, energy resolution, angular resolution, signal-to-noise ratio, and, for ecliptic latitudes within ±45o, temporal resolution and exposure time. The global ENA maps acquired by IMAP-Hi partially overlap in energy and viewing with the ENA maps acquired by the IMAP-Lo and IMAP-Ultra ENA imagers, which we combine to answer fundamental questions about the structure and dynamics of the interaction of the heliosphere and the LISM.

79 ASTRONOMY AND ASTROPHYSICS

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy

Non-destructive identification of absorptive damage sites by photoluminescence brightening

We present a non-destructive photoluminescence (PL) imaging strategy for probing damage growth behavior in fused silica under laser irradiation. Transient wide-field PL image measurements were conducted at varying excitation intensities to investigate the dynamics of radiative defect generation and annihilation in laser-induced damage sites. Our results reveal that, while low excitation intensities predominantly induce PL quenching due to defect annihilation, high-intensity excitation (>0.3 GW/cm 2 at 532 nm) triggers pronounced PL brightening (PLB), indicative of radiative defect generation. Image analysis demonstrates that PLB events are strongly correlated with subsequent damage growth (10 J/cm 2 at 351 nm), whereas overall PL intensity is not. No optically detectable morphological changes were observed during PLB, confirming the non-destructive nature of the technique. We propose that PLB arises from defect-assisted absorption of multiple photons at pre-existing absorptive centers, which enhances local absorptivity and initiates further defect formation. These findings establish PLB monitoring as a sensitive diagnostic tool for identifying damage sites with elevated absorptivity, enabling targeted maintenance and improved laser damage management in optical materials.

Materials science