Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISS Ambient Air Quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

ISS Ambient Air Quality: Updated Inventory of Known Aerosol Sources

Spacecraft cabin air quality is of fundamental importance to crew health, with concerns encompassing both gaseous contaminants and particulate matter. Little opportunity exists for direct measurement of aerosol concentrations on the International Space Station (ISS), however, an aerosol source model was developed for the purpose of filtration and ventilation systems design. This model has successfully been applied, however, since the initial effort, an increase in the number of crewmembers from 3 to 6 and new processes on board the ISS necessitate an updated aerosol inventory to accurately reflect the current ambient aerosol conditions. Results from recent analyses of dust samples from ISS, combined with a literature review provide new predicted aerosol emission rates in terms of size-segregated mass and number concentration. Some new aerosol sources have been considered and added to the existing array of materials. The goal of this work is to provide updated filtration model inputs which can verify that the current ISS filtration system is adequate and filter lifetime targets are met. This inventory of aerosol sources is applicable to other spacecraft, and becomes more important as NASA considers future long term exploration missions, which will preclude the opportunity for resupply of filtration products.

ISS Air Quality↗

NASA's Aerosol Sampling Experiment Summary

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

Sampling Indoor Aerosols on the International Space Station

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements

ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.

Honne, A.↗

Effects of Ambient Alcohol Levels on the Real-time Monitoring of the Atmosphere of the International Space Station

Monitoring of the spacecraft environment is required to ensure the health of the crew and the vehicle systems. For the ISS atmosphere, routine volatile organic compound (VOC) monitoring has been performed for almost a decade by Air Quality Monitors (AQMs). The target compounds measured by the AQMs include three types of chemicals: 1) those compounds that would be harmful to crew, 2) those compounds that have been detected regularly in archival samples, and 3) compounds that, while not necessarily harmful to crew health, could present problems for Environmental Control and Life Support Systems (ECLSS). Following the docking of SpaceX-Demo1 (SpX-DM1), the AQMs began to report high levels of isopropanol (IPA). While elevated IPA is routinely observed with visiting vehicles, the level measured by the AQM, and its continued presence following multiple days of scrubbing, caused concerns regarding the U.S. Water Recovery System. Following the departure of SpX-DM1, the IPA levels decreased to nominal levels, allowing the team to investigate the cause of the elevated measurements. Based on the changes in the shape of the gas chromatograph (GC) traces in the IPA region during docked operations, it appeared that an unknown coeluting species was causing problems with quantification. However, with the docking of Northrup-Grumman-11 (NG-11), the elevated IPA returned, as well as the changes in GC traces. In contrast to the SpX-DM1 results, the AQM IPA results did not return to nominal levels following the departure of NG-11, suggesting that the changes could not be tied directly to the visiting vehicle. In this paper, we will discuss a number of potential causes for both the genuine (measured in archival samples) increases in IPA as well as the much higher levels measured by the AQM. Additionally, we will discuss methods being explored to decrease the potential for a reoccurrence in the future.

William T. Wallace↗

US Navy Submarine Sea Trial of NASA developed Multi-Gas Monitor

During a successful 2 year technology demonstration of the tunable diode laser spectroscopy (TDLS) based Multi-Gas Monitor (MGM) on the International Space Station (ISS), we began discussing with the US Navy the possibility of conducting a sea trial of an MGM on a submarine. The sea trial would also include a gas chromatography/differential mobility spectrometer based Air Quality Monitor (AQM), which is used operationally on ISS for select volatile organic compounds. AQM results will be the subject of a separate paper. The Navy’s interest in testing NASA equipment is in a planned update to the environmental monitoring equipment used aboard submarines. NASA’s goal is studying submarines as closed environment analogs to spacecraft. MGM’s core technology was developed by Vista Photonics Inc using Small Business Innovation Research (SBIR) grants and expanded for various applications using NASA program funding. The MGM measures oxygen, carbon dioxide, ammonia and water vapor in ambient air, displays concentrations with temperature and pressure, and stores 30 second moving averages. The sea trial involves colocating the instrument with the Central Air Monitor (CAM) and connecting it to rack power prior to departure, and letting it run during the entire sea trial of a few months duration. All data stored is inside MGM, with no connection to the vessel data bus. Crew intervention is limited to checking MGM periodically to see that it is working and power cycling if the display is OFF. After the trial is over, the unit with its data will be retrieved. Post sea trial calibration check and data analysis are planned and results will be compared with both CAM data and results from MGM’s ISS technology demonstration.

Mudgett, Paul D.↗

Two New Pieces of Emergency Response Equipment for use in Confined Space Environments

NASA is developing two new pieces of emergency response equipment that recognize and address the constraints of a confined space environment. One piece of equipment is a respirator designed for use in a post fire environment. Traditional first responders generally use supplied air respirators - they provide cool, dry, safe breathing air to the first responder, and because they are supplied at above ambient pressure, the system is tolerant to a loose-fitting mask. Supplied air respirators have a limited supply of air, but because the traditional first responder intends to address the emergency from outside and then retreat, this limited air supply does not pose a serious problem. NASA uses a supplied oxygen respirator for first response to an emergency affecting air quality on the International Space Station. The air supply is rated for 15 minutes - ISS program managers sponsored a hardware development activity to provide the astronauts up to 8 hours of breathing protection after the supplied air system is exhausted. Size and weight limitations prevent the use of a supplied air system for 8 hours for six crew members. A trade study resulted in the selection of a filtering respirator system over a re-breather system; due to design simplicity, operational simplicity, and likely threats to air quality on ISS. The respirator cartridge that filters smoke particles, adsorbs organics and acid gases, and catalytically converts carbon monoxide to carbon dioxide has been qualified for use on ISS, and was delivered on STS-135, the final mission of the Space Shuttle Program.

Graf, John↗

US Navy Submarine Sea Trial of NASA developed Multi-Gas Monitor

During a successful 2 year technology demonstration of the tunable diode laser spectroscopy (TDLS) based Multi-Gas Monitor (MGM) on the International Space Station (ISS), we began discussing with the US Navy the possibility of conducting a sea trial of an MGM on a submarine. The sea trial would also include a gas chromatography/differential mobility spectrometer based Air Quality Monitor (AQM), which is used operationally on ISS for volatile organic compound analysis. AQM preparation and results will be the subject of a separate paper. The Navy's interest in testing NASA equipment in general relates to their ongoing search for better air monitoring technology. NASA's goal is studying submarines as closed environment analogs to spacecraft. MGM's core technology was developed by Vista Photonics Inc. using Small Business Innovation Research (SBIR) grants and expanded for various applications using NASA program funding. The MGM measures oxygen, carbon dioxide, ammonia and water vapor in ambient air, displays concentrations with temperature and pressure, and stores 30 second moving averages. The sea trial involves collocating the instrument with the Central Atmosphere Monitoring System (CAMS Mk II) of the submarine, connecting it to rack power prior to departure, and letting it run during the entire 90 day patrol. All data is stored within MGM, with no connection to the vessel data bus. Crew intervention is limited to checking MGM periodically to see that it is working and power cycling if necessary. After the trial is over, the unit with its data will be retrieved. Post sea trial calibration check and data analysis are planned and results will be compared with both CAMS Mk II data and results from MGM's ISS technology demonstration. Since the sea trial itself has been delayed, this paper describes the preparation of MGM for the sea trial and also provides a summary of the latest data from the ISS MGM technology demonstration.

Mudgett, Paul D.↗

Effects of Ambient Alcohol Levels on the Real-time Monitoring of the Atmosphere of the International Space Station

Effects of Ambient Alcohol Levels on the Real-time Monitoring of the Atmosphere of the International Space StationWilliam T. Wallace,1 Thomas F. Limero,1 Kenneth W. Clark,2 and Daniel B. Gazda31KBR, 2400 NASA Pkwy., Houston, TX 770582JES Tech, 16870 Royal Crest Dr., Houston, TX 770583NASA Lyndon B. Johnson Space Center, 2101 NASA Pkwy., Houston, TX 77058Monitoring of the spacecraft environment is required to ensure the safety of the crew and the health of the vehicle systems. For the ISS atmosphere, routine monitoring has been performed for many years by the Major Constituent Analyzer (MCA) and two Air Quality Monitors (AQMs), which, together, are used to monitor for trace (ppb) levels of 22 volatile organic compounds (VOCs). The target compounds measured by the AQMs include three types of chemicals: 1) those compounds that would be harmful to crew, 2) those compounds that have been detected regularly in archival samples, and 3) compounds that, while not necessarily harmful to crew health, could present problems for Environmental Control and Life Support Systems (ECLSS).In March 2019, following the docking of SpaceX-Demo1 (SpX-DM1), the on-board AQMs began to report extremely high levels of isopropyl alcohol (IPA). While elevated IPA is not abnormal following the docking of visiting vehicles (due to cleaning of the cargo prior to flight), the level measured by the AQM, and its continued presence following multiple days of scrubbing, caused concerns regarding the U.S. Water Recovery System. Following the departure of SpX-DM1, the IPA levels decreased to nominal levels, allowing the team to investigate the cause of the elevated measurements. Initially, based on the changes in the shape of the gas chromatograph (GC) traces in the IPA region during docked operations, it appeared that some unknown coeluting species was causing problems with quantification. However, with the docking of Northrup-Grumman-11 (NG-11), the elevated IPA concentrations returned, as well as the changes in GC traces. In contrast to the SpX-DM1 results, though, the AQM IPA results did not return to nominal levels following the departure of NG-11, suggesting that the changes could not be tied directly to the visiting vehicle.In this paper, we will discuss a number of potential causes for both the genuine (measured in archival samples) increases in IPA as well as the much higher levels measured by the AQM. Additionally, we will discuss methods being explored to decrease the potential for a reoccurrence in the future.

William T Wallace↗

A Study of the Kinetics of the CO Oxidation Catalyst in a Human Spaceflight Fire Cartridges as a Method to Understand and Predict Performance

Fire Cartridges (FC) are an integral part of fire response on ISS, Orion and Gateway. When a pair of FCs are integrated with an Emergency Mask, they can be used to provide safe breathing air on these vehicles in a post-fire environment. The FCs have two primary mechanisms for removing contaminants from the air, an activated carbon (AC) bed which adsorbs the majority of fire byproducts, and a catalyst bed consisting of gold nanoparticles supported on iron oxide which oxidized CO to CO2 under near ambient conditions. While the FC catalyst has proven its ability to convert CO under relevant conditions, this paper attempts to address the apparent inconsistent performance of the catalyst seen in testing. Numerous variables effect the performance of the catalyst, including but not limited to: reaction environment, reactant gas composition, inert gas composition, catalyst age, and catalyst lot. This paper discusses the importance of these variables and attempts a fundamental mechanistic explanation for the effects of each variable. The fundamental mechanisms are then used to establish the magnitude of expected performance variability, which were validated against real test data of flight quality FCs.

Fire Cartridge↗

A Study of the Kinetics of the CO Oxidation Catalyst in a Human Spaceflight Fire Cartridges as a Method to Understand and Predict Performance

Fire Cartridges (FC) are an integral part of fire response on ISS, Orion and Gateway. When a pair of FCs are integrated with an Emergency Mask, they can be used to provide safe breathing air on these vehicles in a post-fire environment. The FCs have two primary mechanisms for removing contaminants from the air, an activated carbon (AC) bed which adsorbs the majority of fire byproducts, and a catalyst bed consisting of gold nanoparticles supported on iron oxide which oxidized CO to CO2 under near ambient conditions. While the FC catalyst has proven its ability to convert CO under relevant conditions, this paper attempts to address the apparent inconsistent performance of the catalyst seen in testing. Numerous variables effect the performance of the catalyst, including but not limited to: reaction environment, reactant gas composition, inert gas composition, catalyst age, and catalyst lot. This paper discusses the importance of these variables and attempts a fundamental mechanistic explanation for the effects of each variable. The fundamental mechanisms are then used to establish the magnitude of expected performance variability, which were validated against real test data of flight quality FCs.

Fire Cartridge↗