Engineering PapersSearch

SEARCH · Engineering Papers

Results for “ISOTOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES

Chlorine isotope separations using thermal diffusion

In a chloride molten salt fast reactor (Cl-MSFR), the fuel salt might be comprised of a specific eutectic composition of alkali and alkaline chlorides that solubilize major and minor actinide chlorides as the fertile component(s). Each of the chloride species contain the natural abundance ( 35 Cl ~76% and 37 Cl ~24%) of the two stable isotopes of chlorine 35 Cl and 37 Cl. There has been an ongoing controversy for the operation of the Cl-MSFRs concerning the potential of the 35 Cl(n,γ) 36 Cl, 35 Cl(n,p) 35 S, 35 Cl(n,α) 32 S reactions to produce 36 Cl, 32 S, and 32 P at relevant energies [Bulmer 1956]. The undesirable attributes of irradiated 35 Cl are enumerated further below.

07 ISOTOPE AND RADIATION SOURCES

Analysis of Liquids Using the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER)

We developed a sensor called the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER) probe, which uses an atmospheric pressure glow discharge below the surface of liquids to excite species in the liquid. Through emission spectroscopy of molten salts, liquid metals, and heavy water, we demonstrated the SPIDER probe’s high resolution, accuracy, and versatility. We successfully identified trace concentrations of transition and rare-earth metals in molten salts and detected the isotopic shift of the H β → D β emission line. Our analysis revealed unconventional spectral alkali line shapes, indicating two competing excitation modes: film explosion and droplet vaporization. The film explosion mode, characterized by dense plasma, exhibited self-reversal and broadband continuum emission, while the droplet vaporization mode, associated with diffusive plasma, produced narrow-line emissions. Furthermore, by analyzing circuit transients alongside individual plasma events, we observed that film explosions generate higher currents, likely due to a shorter plasma length as the current preferentially flows through the thin liquid layer. Altogether, our results highlight the SPIDER probe’s efficacy and flexibility, making it well-suited for online material quantification of liquids in extreme environments.

AES

Isotope engineering for spin defects in van der Waals materials

Abstract Spin defects in van der Waals materials offer a promising platform for advancing quantum technologies. Here, we propose and demonstrate a powerful technique based on isotope engineering of host materials to significantly enhance the coherence properties of embedded spin defects. Focusing on the recently-discovered negatively charged boron vacancy center ($${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − ) in hexagonal boron nitride (hBN), we grow isotopically purified h 10 B 15 N crystals. Compared to$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − in hBN with the natural distribution of isotopes, we observe substantially narrower and less crowded$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − spin transitions as well as extended coherence timeT 2 and relaxation timeT 1 . For quantum sensing,$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − centers in our h 10 B 15 N samples exhibit a factor of 4 (2) enhancement in DC (AC) magnetic field sensitivity. For additional quantum resources, the individual addressability of the$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − hyperfine levels enables the dynamical polarization and coherent control of the three nearest-neighbor 15 N nuclear spins. Our results demonstrate the power of isotope engineering for enhancing the properties of quantum spin defects in hBN, and can be readily extended to improving spin qubits in a broad family of van der Waals materials.

Science & Technology - Other Topics

Nuclear–Electronic Orbital General Rate Theory: Predicting Hydrogen Kinetic Isotope Effects in the Deep Tunneling Regime

Hydrogen transfer is a critical component of many chemical and biological processes. The ratio of rate constants for hydrogen and deuterium transfer defines the H/D kinetic isotope effect (KIE), which is a powerful tool for elucidating hydrogen transfer mechanisms. Interpretation of experimental H/D KIEs relies on accurate and affordable computational methods. However, due to their light mass, hydrogen and deuterium can undergo tunneling, which is challenging to describe in multidimensional molecular systems. Herein, we introduce the nuclear–electronic orbital general rate theory (NEO-GRT), which enables the efficient prediction of H/D KIEs based on full-dimensional molecular quantum chemistry calculations. The NEO-GRT approach describes the hydrogen transfer rate constant with a general expression that spans the vibrationally adiabatic and nonadiabatic hydrogen tunneling regimes. The input quantities are computed using NEO density functional theory, which treats the transferring hydrogen or deuterium nucleus quantum mechanically on the same level as the electrons. We investigate two intramolecular proton transfer reactions in organic molecules at temperatures down to 50 K to evaluate the performance of NEO-GRT by comparison to transition state theory and ring-polymer instanton theory. The KIEs computed with NEO-GRT agree with those calculated using ring-polymer instanton theory for the full-dimensional molecular systems at the same level of electronic structure theory. This agreement indicates that NEO-GRT captures the deep hydrogen tunneling effects, in contrast to transition state theory, which neglects such effects. Given its relatively low computational cost, NEO-GRT is a promising approach for predicting H/D KIEs in large organic and organometallic systems.

Hydrogen

Toward the Limits of Nuclear Existence: First Science with FRIB

The opportunity to explore the properties of short-lived atomic nuclei—or rare isotopes—in laboratories has enabled discoveries across the sciences related to the nature of the nuclear force and the limits of nuclear existence, the origin of the elements in the Universe, the cosmic matter–antimatter asymmetry, and the application of rare isotopes for society and the nation. The newest-generation Facility for Rare Isotope Beams (FRIB) on the campus of Michigan State University commenced operations in May 2022 as a user facility for the US Department of Energy, Office of Science, Office of Nuclear Physics. FRIB provides fast, stopped, and reaccelerated beams of rare isotopes for measurements, serving a 1,800-member-strong community of scientists from around the world. Here, this article reviews some of the first results from FRIB, showcasing the breadth of the science discoveries that have already occurred while the facility is ramping up to full capability.

FRIB

Reduced-order CFD modeling of cryogenic hydrogen isotope extrusion for pellet fueling

This study presents a reduced-order model (ROM) for computational fluid dynamics (CFD) simulations of cryogenic hydrogen isotope extrusions, focusing on protium (H₂) and deuterium (D₂) piston extruders. Using a 2D axisymmetric ROM in ANSYS-Polyflow, significant computational savings were achieved (runtime reduced from 9∼24 h to 3∼5 min), with extrusion force discrepancies between the 2D ROM and 3D models being on the order of 1%. Parametric studies identified optimal cutoff shear rates in the viscosity model (0.01/s for H₂ and 0.001/s for D₂), providing recommendations for future simulations. Finally, a comprehensive comparison of ROM results with experimental data was performed across varying geometries, cryogenic materials, temperatures, extrusion lengths, and piston velocities. Predictions at low extrusion temperatures met the objective of providing quick and efficient solutions with an acceptable extrusion force error of approximately 10% or less, validating the effectiveness of the 2D ROM approach. However, at high temperatures closer to the triple point, extrusion force error grows, which necessitates developing an improved model that accounts for temperature effects, e.g. melting. Nevertheless, the findings still represent a significant improvement in efficiency of CFD modeling of cryogenic hydrogenic extrusion. The ROM framework can also be extended to tritium (T2) and screw extruders, which will ultimately provide a fast and effective tool for optimizing pellet injector design for ITER and future reactor systems.

Fan, Joy [ORNL] (ORCID:0000000229751735)

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup

Application of Nuclear Technology to Art Identification Problems: First Annual Report

Throughout the centuries, as man has become increasingly affluent, his interest in antiquities and objects of art, and the price he has been willing to pay for them, has increased. Inevitably, one result has been to attract the unscrupulous to the production and sale of counterfeit paintings, sculptures, and other works of art. The skill of forgers varies but often is highly sophisticated. However, dealers, museum curators, and other experts have also become more skillful in the detection of forgeries. Scientific tools of increasing sensitivity and sophistication have gradually been applied to the examination of the materials of art and archaeology. Such tools frequently support and render more reliable the judgment of the experts. The quality of forgeries may improve further as their makers become acquainted with the new methods of detection and in turn learn to circumvent or confound the methods. Therefore, the development of still more advanced methods of examination has great utility in the art world. This is particularly true if the ultimate effect is to make circumvention of the methods of examination so costly that the economic incentives for producing forgeries may be substantially reduced, if not eliminated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Physical thickness characterization of the FRIB production targets

The FRIB heavy-ion accelerator, commissioned in 2022, is a leading facility for producing rare isotope beams (RIBs) and exploring nuclei beyond the limits of stability. These RIBs are produced via reactions between stable primary beams and a graphite target. Approximately 20–40% of the primary beam power is deposited in the target, requiring efficient thermal dissipation. Currently, FRIB operates with a primary beam power of up to 20 kW. To enhance thermal dissipation efficiency, a single-slice rotating graphite target with a diameter of approximately 30 cm is employed. The effective target region is a 1 cm-wide outer rim of the graphite disc. To achieve high RIB production rates, the areal thickness variation must be constrained within 2%. This paper presents physical thickness characterizations of FRIB production targets with various nominal thicknesses, measured using a custom-built non-contact thickness measurement apparatus.

Instrumentation for radioactive beams (fragmentati

Emissivity measurements of CuCrZr alloy

The Facility for Rare Isotope Beams (FRIB) heavy-ion accelerator, in user operation since 2022, produces rare isotope beams via interactions of high-intensity stable ion beams with a graphite production target. Approximately 20–40% of the primary beam power is deposited in the target, while the remaining 60–80% is absorbed by the beam dump. The minichannel beam dump (MCBD), currently operated at 20 kW and designed for operation up to 50 kW, uses CuCrZr alloy absorber plates. Thermal validation and thermal cycling tests of the MCBD were conducted at the Applied Research Laboratory (ARL) at Pennsylvania State University. Temperature measurements were obtained from an infrared (IR) camera. Since accurate temperature determination requires reliable emissivity values, the emissivity of CuCrZr was measured using the IR camera validated against thermocouple reference temperatures up to approximately 650 °C. The measurements were conducted under a vacuum level of approximately 10 -5 torr to minimize emissivity variations due to surface oxidation. The emissivity of CuCrZr was determined to be 0.057 ± 0.009 using a constant fit to the measured data over the surface temperature range from 100–650 °C.

Accelerator Subsystems and Technologies

Nuclear Physics Made Very, Very Easy

The fundamental approach to nuclear physics was prepared to introduce basic reactor principles to various groups of non-nuclear technical personnel associated with NERVA Test Operations. NERVA Test Operations functions as the field test group for the Nuclear Rocket Engine Program. Nuclear Engine for Rocket Vehicle Application (NERVA) program is the combined efforts of Aerojet-General Corporation as prime contractor, and Westinghouse Astronuclear Laboratory as the major subcontractor, for the assembly and testing of nuclear rocket engines. Development of the NERVA Program is under the direction of the Space Nuclear Propulsion Office, a joint agency of the U. S. Atomic Energy Commission and the National Aeronautics and Space Administration. This report is being reprinted for use in the U. S. Atomic Energy Commission and National Aeronautics and Space Administration educational and technology utilization programs.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Kryptonate Hydrogen Detection System (Final Report)

A prototype model of a multipurpose instrument which demonstrates the applicability of the Kryptonate® technique for detecting hydrogen gas was developed. This report describes the construction of the instrument and presents a laboratory evaluation of its performance. Performance was excellent. The instrument was designed to detect hydrogen in air at concentrations of 0-3% by volume, and to detect hydrogen in nitrogen or other inert gas at concentrations of 0-10% by volume. Other detection levels (both higher and lower) could be set if required. Ultimate response times can be made of the order of 0.5 seconds. The instrument is an all solid state device operating from 120V 60 Hz power source. The instrument has been designed to enable modifications to be made with a minimum amount of difficulty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Nuclear Isomer Discovery Database Released

Nuclear isomers correspond to excited states in nuclides with finite lifetimes. Here, after the discovery of isotopes–different nuclides of the same element–in 1913 by Frederick Soddy [Citation1], Otto Hahn postulated in 1921 [Citation2] that there are even different metastable states within one isotope. In analogy to chemical isomers, which are the same compounds with distinct structures, nuclear isomers have the same number of protons and neutrons but in different configurations.

Thoennessen, Michael [Michigan State University, E