Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IRON 53”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A new insight into neutrino energy loss by electron capture of iron group nuclei in magnetar surfaces

Based on the relativistic mean-field effective interactions theory, and the Lai dong model, we discuss the influences of superstrong magnetic fields (SMFs) on electron Fermi energy, nuclear blinding energy, and single-particle level structure in magnetar surfaces. Using the Shell-Model Monte Carlo method and the Random Phase Approximation theory, we analyze the neutrino energy loss rates (NELRs) by electron capture for iron group nuclei in SMFs. First, when B {sub 12} < 100, we find that the SMFs have a slight influence on the NELRs for most nuclides at relativistic low temperatures (e.g., T {sub 9} = 0.233); nevertheless, the NELRs increase by more than four orders of magnitude at relativistic high temperatures (e.g., T {sub 9} = 15.53). When B {sub 12} > 100, the NELRs decrease by more than three orders of magnitude (e.g., at T {sub 9} = 15.53 for {sup 52–61}Fe, {sup 55–60}Co, and {sup 56–63}Ni). Second, for a certain value of magnetic field and temperature, the NELRs increase by more than four orders of magnitude when ρ{sub 7}⩽10{sup 3}, but as the density increases (i.e., when ρ{sub 7}>10{sup 3}), there is almost no influence on the density of NELRs. For the density around ρ{sub 7}=10{sup 2}, there is an abrupt increase in NELRs when B {sub 12} ≥ 10{sup 3.5}. Such jumps are an indication that the underlying shell structure has changed due to single-particle behavior by SMFs. Finally, we compare our NELRs with those of Fuller et al. (FFN) and Nabi and Klapdor-Kleingrothaus (NKK). For the case without SMFs, one finds that our rates for certain nuclei are close to about five orders of magnitude lower than FFN and NKK at relativistic low temperatures (e.g., T {sub 9} = 1). However, at a relativistic high temperature (e.g., T {sub 9} = 3), our results are in good agreement with NKK, but about one order of magnitude lower than FFN. For the case with SMFs, our NELRs for some iron group nuclei can be about five orders of magnitude higher than those of FFN and NKK. (Note that B {sub 12}, T {sub 9}, and ρ {sub 7} are in units of 10{sup 12} G, 10{sup 9} K, and 10{sup 7} g cm{sup −3}, respectively.)

79 ASTRONOMY AND ASTROPHYSICS↗

E6 Gamma Decay

Rare electric hexacontatetrapole (E6) transitions are studied in the full (f{sub 7/2},f{sub 5/2},p{sub 3/2},p{sub 1/2}) shell-model basis. Comparison of theory to the results from the gamma decay in {sup 53}Fe and from inelastic electron scattering on {sup 52}Cr provides unique and interesting tests of the valence wavefunctions, the models used for energy density functionals and into the origin of effective charge.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 53

The 1999 evaluation of A = 53 (1999Hu14) has been revised using experimental nuclear structure data available before April 2007. A summary of information obtained in various reaction and decay experiments is presented, together with adopted level schemes and properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-612: Photonuclear Activation of Prosthetic Hips in Radiotherapy

Purpose: To measure the neutron induced activation of a prosthetic hip when exposed to an 18 MV radiotherapy linac beam to assess the potential dose to patients. Methods: A prosthetic hip (Thackray, UK) was placed in a water phantom and irradiated (both in-field and out-of-field) with an 18 MV linac beam. Gamma spectroscopy was used to identify the radioisotopes produced. Following the in-field irradiation where the induced activity is higher, high sensitivity lithium fluoride Thermoluminescence Dosimeters (TLD-100H) (Harshaw, USA) were placed on the surface to measure the dose which would be deposited to nearby tissue resulting from the induced radioactivity. Results: The radioisotopes produced in the hip prosthesis have been identified as {sup 5{sup 2}}V, {sup 5{sup 3}}Fe, and {sup 56}Mn which have half-lives of 3.74, 8.51 and minutes respectively. The 378 and 511 keV characteristic peaks of {sup 5{sup 3}}Fe do not appear in the spectra collected from hips irradiated in the out-of-field region. This isotope is produced by photonuclear interactions within the hip itself. {sup 52}V and {sup 56}Mn appear in spectra collected from hips irradiated either within the photon beam or in the nearby out-of-field region, implying that they are produced by incident neutron radiation produced in components of the linear accelerator.The integrated dose which would be deposited in the tissue immediately surrounding the hip after four hours (1.5 half-lives of the longest lived product) was measured as approximately 100 µGy, following a 10,000 MU irradiation of the prosthesis. A highly accurate measurement of the dose is challenging because of the irregular shape of the prosthesis. Conclusion: The cumulative dose measured at the surface of the hip is 0.0001% of the in-field dose, and is therefore negligible compared with the doses the patient receives as a consequence of their treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

A search for the iron absorption edge in the tail of an X-ray burst from X1636 - 53

Model atmosphere calculations of the spectrum of a neutron star cooling after an X-ray burst show that the photoelectric edge of iron should be prominent. No clear evidence for such a redshifted feature in the spectrum of a burst from X1636 - 53 is found, and it is concluded that the iron abundance there must be less than 0.3 solar. Unless the iron abundance of the surface matter on the neutron star is highly time-dependent, the present result argues against the 4.1-keV absorption line seen in some bursts from X1636 - 53 by Waki et al. (1984) being due to iron. The iron edge will be a powerful diagnostic of the surface redshift of the neutron star in burst sources where the iron abundance is more nearly solar.

Day, C. S. R.↗

Microbial interactions with phosphorus containing glasses representative of vitrified radioactive waste

The presence of phosphorous in borosilicate glass (at 0.1 – 1.3 mol % P 2 O 5 ) and in iron-phosphate glass (at 53 mol % P 2 O 5 ) stimulated the growth and metabolic activity of anaerobic bacteria in model systems. Dissolution of these phosphorous containing glasses was either inhibited or accelerated by microbial metabolic activity, depending on the solution chemistry and the glass composition. The breakdown of organic carbon to volatile fatty acids increased glass dissolution. The interaction of microbially reduced Fe(II) with phosphorus-containing glass under anoxic conditions decreased dissolution rates, whereas the interaction of Fe(III) with phosphorous-containing glass under oxic conditions increased glass dissolution. Phosphorous addition to borosilicate glasses did not significantly affect the microbial species present, however, the diversity of the microbial community was enhanced on the surface of the iron phosphate glass. Results demonstrate the potential for microbes to influence the geochemistry of radioactive waste disposal environments with implication for wasteform durability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of iron on the lattice thermal conductivity of Earth’s deep mantle and implications for mantle dynamics

We discuss how iron may critically influence the physical properties and thermochemical structures of Earth’s lower mantle. Its effects on thermal conductivity, with possible consequences on heat transfer and mantle dynamics, however, remain largely unknown. We measured the lattice thermal conductivity of lower-mantle ferropericlase to 120 GPa using the ultrafast optical pump-probe technique in a diamond anvil cell. The thermal conductivity of ferropericlase with 56% iron significantly drops by a factor of 1.8 across the spin transition around 53 GPa, while that with 8–10% iron increases monotonically with pressure, causing an enhanced iron substitution effect in the low-spin state. Combined with bridgmanite data, modeling of our results provides a self-consistent radial profile of lower-mantle thermal conductivity, which is dominated by pressure, temperature, and iron effects, and shows a twofold increase from top to bottom of the lower mantle. Such increase in thermal conductivity may delay the cooling of the core, while its decrease with iron content may enhance the dynamics of large low shear-wave velocity provinces. Our findings further show that, if hot and strongly enriched in iron, the seismic ultralow velocity zones have exceptionally low conductivity, thus delaying their cooling.

58 GEOSCIENCES↗

Assessment of Energy Efficiency Improvement and CO2 Emission Reduction Potentials in India's Iron and Steel Industry

India’s 2010 annual crude steel production was 68 Mt which accounted for nearly five percent of the world’s annual steel production in the same year. In 2007, roughly 1600 PJ were consumed by India’s iron and steel industry to produce 53 Mt of steel. We identified and analyzed 25 energy efficiency technologies and measures applicable to the processes in the Indian iron and steel industry. The Conservation Supply Curve (CSC) used in this study is an analytical tool that captures both the engineering and the economic perspectives of energy conservation. Using a bottom-up electricity CSC model and compared to an electricity price forecast the cumulative plant-level cost-effective electricity savings potential for the Indian iron and steel industry for 2010-2030 is estimated to be 66 TWh, and the cumulative plant-level technical electricity saving potential is only slightly greater than 66 TWh for the same period. The primary energy related CO2 emissions reduction associated with cost-effective electricity savings is 65 Mt CO2. Compared to a fuel price forecast, an estimated cumulative cost-effective fuel savings potential of 768 PJ with associated CO2 emission reduction of 67 Mt CO2 during 2010-2030 is possible. In addition, a sensitivity analysis with respect to the discount rate used is conducted to assess the effect of changes in this parameter on the results. The result of this study gives a comprehensive and easy to understand perspective to the Indian iron and steel industry and policy makers about the energy efficiency potential and its associated cost.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ASTROPHYSICAL SHRAPNEL: DISCRIMINATING AMONG NEAR-EARTH STELLAR EXPLOSION SOURCES OF LIVE RADIOACTIVE ISOTOPES

We consider the production and deposition on Earth of isotopes with half-lives in the range 10{sup 5}-10{sup 8} yr that might provide signatures of nearby stellar explosions, extending previous analyses of Core-Collapse Supernovae (CCSNe) to include Electron-Capture Supernovae (ECSNe), Super-Asymptotic Giant Branch (SAGB) stars, Thermonuclear/Type Ia Supernovae (TNSNe), and Kilonovae/Neutron Star Mergers (KNe). We revisit previous estimates of the {sup 60}Fe and {sup 26}Al signatures, and extend these estimates to include {sup 244}Pu and {sup 53}Mn. We discuss interpretations of the {sup 60}Fe signals in terrestrial and lunar reservoirs in terms of a nearby stellar ejection ∼2.2 Myr ago, showing that (1) the {sup 60}Fe yield rules out the TNSN and KN interpretations, (2) the {sup 60}Fe signals highly constrain SAGB interpretations but do not completely them rule out, (3) are consistent with a CCSN origin, and (4) are highly compatible with an ECSN interpretation. Future measurements could resolve the radioisotope deposition over time, and we use the Sedov blast wave solution to illustrate possible time-resolved profiles. Measuring such profiles would independently probe the blast properties including distance, and would provide additional constraints for the nature of the explosion.

79 ASTRONOMY AND ASTROPHYSICS↗

Microbial Iron Cycling in Acidic Geothermal Springs of Yellowstone National Park: Integrating Molecular Surveys, Geochemical Processes, and Isolation of Novel Fe-Active Microorganisms

Geochemical, molecular, and physiological analyses of microbial isolates were combined to study the geomicrobiology of acidic iron oxide mats inYellowstone National Park. Nineteen sampling locations from 11 geothermal springs were studied ranging in temperature from 53 to 88°C and pH 2.4 to 3.6. All iron oxide mats exhibited high diversity of crenarchaeal sequences from the Sulfolobales, Thermoproteales, and Desulfurococcales. The predominant Sulfolobales sequences were highly similar to Metallosphaera yellowstonensis str. MK1, previously isolated from one of these sites. Other groups of archaea were consistently associated with different types of iron oxide mats, including undescribed members of the phyla Thaumarchaeota and Euryarchaeota. Bacterial sequences were dominated by relatives of Hydrogenobaculum spp. above 65–70°C, but increased in diversity below 60°C. Cultivation of relevant iron-oxidizing and iron-reducing microbial isolates included Sulfolobus str. MK3, Sulfobacillus str. MK2, Acidicaldus str. MK6, and a new candidate genus in the Sulfolobales referred to as Sulfolobales str. MK5. Strains MK3 and MK5 are capable of oxidizing ferrous iron autotrophically, while strain MK2 oxidizes iron mixotrophically. Similar rates of iron oxidation were measured for M. yellowstonensis str. MK1 and Sulfolobales str. MK5. Biomineralized phases of ferric iron varied among cultures and field sites, and included ferric oxyhydroxides, K-jarosite, goethite, hematite, and scorodite depending on geochemical conditions. Strains MK5 and MK6 are capable of reducing ferric iron under anaerobic conditions with complex carbon sources. The combination of geochemical and molecular data as well as physiological observations of isolates suggests that the community structure of acidic Fe mats is linked with Fe cycling across temperatures ranging from 53 to 88°C.

59 BASIC BIOLOGICAL SCIENCES↗

Using geochemical indicators to distinguish high biogeochemical activity in floodplain soils and sediments, Science of the Total Environment: Dataset

Data associated with analysis of sediment samples collected in the East River watershed and Rifle floodplain sites, CO. Samples were collected and analyzed as part of two student MS theses at Colorado School of Mines (Kenwell and Prugue) over a time period ranging from 2012 to 2015. Analyses include total organic carbon, leachable Fe and Mn, and total microbial DNA; all analyses performed at Colorado School of Mines. Methods: Samples were collected from core during a drilling campaign at the Rifle Site. Samples were collected every 1.5 m. At the East River site soil and sediment samples were collected using hand-augered bulk density sampler. Collected samples were stored at -20C until analysis. Samples were thawed in an anaerobic chamber and subsampled for extractions and DNA analysis. Samples for DNA analysis were freeze-dried, the remaining sample was oven dried and ground to 0.991 cm for TOC and leaching analysis. TOC analysis was performed on duplicate samples using a CM 5014 Coulometer (UIC, Joliet, IL, USA). Two chemical extractions were performed: hydroxylamine (HA) extraction of Fe and Mn adapted from Lovley et al., 1987 and synthetic precipitation (ppt) leaching adapted from EPA method 1312 (EPA, 1994) . For theHA extraction 3g of wet sediment was mixed with 150 mL of 0.5 N HCl in one bottle and another 3 g of sediment was mixed with 150 mL of 0.25 N hydroxylamine hydrochloride in 0.5 N HCl. Extraction were performed for 24 hours at room temperature after which samples of the liquid were removed and filtered to 0.45 micron and analyzed by ICP-AES. HA-reducible iron and manganese concentrations were determined by difference between the two extractions. For ppt leaches, a 60:40 sulfuric:nitric acid mixture was added to Milliq water to a pH of 4.2 and combined with sediment in a 20:1 mass ratio of acid to sediment. The extraction was performed for 18 hours at room temperature after which the samples of the liquid were removed and filtered to 0.45 micron and analyzed by ICP-AES. DNA was sampled from sediment using a PowerSoil DNA Isolation Kit and extractions were performed according to manufactured instuctions with one adjustment, a 1 minute bead beating replaced the 10 minute vortexing step. Extracted DNA was stored at -20C. Quantitative PCR was performed in triplicate on a Roche LightCycler 480 system and working curves were created by amplifying environmental samples with primers and bead purifying them with Agencourt AMPure XP. Analysis was performed with a Qubit 2.0 Fluorometer and Qubit dsDNA High Sensitivity Assay Kit with results converted to copies using the URI Genomics and Sequencing Center converter (Staroscik, 2004). Additional method details can be found in Kenwell et al., 2016. Lovley, D.R., Phillips, E.J.P. (1987). Rapid assay for microbially reducible ferric iron in aquatic sediments. Applied and Environmental Microbiology, 53(7), 1536-1540. Staroscik, A. (2004). Calculator for determining the number of copies of a template. URI Genomics & Sequencing Center. <http://cels.uri.edu/gsc/cndna.html>. EPA. (1994). Method 1312: Synthetic precipitation leaching procedure.

54 ENVIRONMENTAL SCIENCES↗

Persistence of gamma-H2AX and 53BP1 foci in proliferating and nonproliferating human mammary epithelial cells after exposure to gamma-rays or iron ions

To investigate {gamma}-H2AX (phosphorylated histone H2AX) and 53BP1 (tumour protein 53 binding protein No. 1) foci formation and removal in proliferating and non-proliferating human mammary epithelial cells (HMEC) after exposure to sparsely and densely ionizing radiation under different cell culture conditions. HMEC cells were grown either as monolayers (2D) or in extracellular matrix to allow the formation of acinar structures in vitro (3D). Foci numbers were quantified by image analysis at various time points after exposure. Our results reveal that in non-proliferating cells under 2D and 3D cell culture conditions, iron-ion induced {gamma}-H2AX foci were still present at 72 h after exposure, although 53BP1 foci returned to control levels at 48 h. In contrast in proliferating HMEC, both {gamma}-H2AX and 53BP1 foci decreased to control levels during the 24-48 h time interval after irradiation under 2D conditions. Foci numbers decreased faster after {gamma}-ray irradiation and returned to control levels by 12 h regardless of marker, cell proliferation status, and cell culture condition. Conclusions: The disappearance of radiation induced {gamma}-H2AX and 53BP1 foci in HMEC have different dynamics that depend on radiation quality and proliferation status. Notably, the general patterns do not depend on the cell culture condition (2D versus 3D). We speculate that the persistent {gamma}-H2AX foci in iron-ion irradiated non-proliferating cells could be due to limited availability of double strand break (DSB) repair pathways in G0/G1-phase, or that repair of complex DSB requires replication or chromatin remodeling.

59 BASIC BIOLOGICAL SCIENCES↗

Sintering of Iron Ores in a Millipot in Comparison with Tablet Testing and Industrial Process

To explore the feasibility of small-scale sintering pot testing, a ‘millipot’ facility (diameter of 53 mm and height of 400 mm) was established and used to examine the sintering performance of iron ores and other non-traditional ferrous materials. The sintering performance of a millipot was examined across a range of different operational conditions (coke rate and suction pressure) and compared with an industrial sinter strand operation. Tablet tests were also performed to assist in the design of the millipot experiments and identify conditions for achieving mineral composition similar to the industrial sinter. For the millipot experiments, the materials used need to be compacted to increase the bulk density, and a higher coke rate is required to compensate the high heat loss caused by wall effects. A higher suction pressure is also necessary to maintain an oxidizing atmosphere in the sinter bed. As expected, it was not possible to eliminate the wall effect, which resulted in more primary hematite at edges of the sintered column. However, the sintered material from the center of column simulates industrial sinter reasonably well. As such, millipot provides a practical way to evaluate the sintering process and material performance at laboratory scale, helping to bridge the gap between tablet sintering and large scale pot sintering, or full scale plant trial. The results of millipot testing can be used for designing larger scale experiments or commercial sintering trials.

36 MATERIALS SCIENCE↗

IRON-60 HETEROGENEITY AND INCOMPLETE ISOTOPE MIXING IN THE EARLY SOLAR SYSTEM

Short-lived radionuclides (e.g., {sup 26}Al, {sup 53}Mn, {sup 60}Fe, {sup 182}Hf) are widely used to refine the chronology of the early solar system. They provide chronological information, however, only if they were homogeneously distributed in the source region of the objects under scrutiny at the time of their formation. With the high level of precision now achieved on isotopic measurements, very short time intervals can in principle be resolved and a precise evaluation of the initial homogeneity degree becomes increasingly crucial. High-precision nickel isotope data for differentiated meteorites (angrites, ureilites) and chondritic (CB) components allow us to test the initial distribution of radioactive {sup 60}Fe and stable Ni isotopes. Although these meteorites appear to have formed nearly contemporaneously, they yield variable initial {sup 60}Fe/{sup 56}Fe ratios. Besides, the CB metal nodules and ureilite silicates show nucleosynthetic anomalies. The new data presented here do not confirm the recently inferred late injection of {sup 60}Fe into the protoplanetary disk. Instead, live {sup 60}Fe was present, but heterogeneously distributed, from the start of the solar system, revealing an incomplete mixing of material from various nucleosynthetic sources and restricting the use of the {sup 60}Fe-{sup 60}Ni system as a chronometer.

79 ASTRONOMY AND ASTROPHYSICS↗

Relative Efficiency of TLD-100 to High Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to 137Cs) dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, G. D.↗

Relative Efficiency of TLD-100 to Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to (137)Cs dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, Gautam D.↗