High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features

Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract

Reardon, Allison R. (ORCID:0000000165830134)

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Evaluating Material Design Principles for Calcium-Ion Mobility in Intercalation Cathodes

Multivalent-ion batteries offer an alternative to Li-based technologies, with the potential for greater sustainability, improved safety, and higher energy density, primarily due to their rechargeable system featuring a passivating metal anode. Although a system based on the Ca 2+ /Ca couple is particularly attractive given the low electrochemical plating potential of Ca 2+ , the remaining challenge for a viable rechargeable Ca battery is to identify Ca cathodes with fast ion transport. In this work, a high-throughput computational pipeline is adapted to (1) discover novel Ca cathodes in a largely unexplored space of empty intercalation hosts and (2) develop material design rules for Ca-ion mobility. One candidate from the screening, W 2 O 3 (PO 4 ) 2 , is confirmed to have a low Nudged Elastic Band (NEB) barrier of 168 meV within a one-dimensional (1D) ion percolation topology. This candidate is subsequently synthesized and electrochemically tested, achieving reversible Ca cycling with a capacity of 25 mA h/g. To further accelerate the screening for promising Ca intercalation electrodes, machine learning (ML) Random Forest (RF) and Extreme Gradient Boosting (XGB) classification models are created with local environment descriptors based on a large, structurally and chemically diverse dataset of minimum energy pathways, spanning over 5,000 density functional theory (DFT) site energy calculations. Accuracies of 92% are achieved, material design metrics are quantified, ML force-fields are leveraged in an accelerated iteration of the screening, and a total of 27 novel Ca cathode materials are highlighted for further investigation.

25 ENERGY STORAGE

Electrochemical Reactions Under Reverse Bias Create Additional Mobile Ions That Enable Hole Tunneling in Metal Halide Perovskite Diodes

Gradual reverse-bias breakdown in metal-halide perovskite diodes and solar cells is thought to originate from hole tunneling through steep bands in an ionic depletion region near the electron-transport layer after positively charged iodine vacancies accumulate near the hole-transport layer (HTL). However, typical reported mobile-ion concentrations near 1 x 10^17 cm-3 are too small to quantitatively explain significant tunneling-current densities and (Zener) breakdown observed near -5 V. Here, we show that inferred mobile-ion concentrations increase by more than 100x, to over 1 x 10^18cm-3 , within just 3 min of reverse bias at -6.0 V in p-i-n perovskite diodes. We attribute this increase to iodide oxidation and coupled iodine vacancy creation that must be balanced by reduction reactions near the HTL. Sub-optimal HTL coverage leads to direct contact between the transparent conducting electrode and perovskite, facilitates reduction events, enables the creation of even larger inferred mobile-ion concentrations (~1 x 10^19cm-3 ), and leads to faster degradation under reverse bias. This explains previous work that showed increased breakdown voltages and improved reverse-bias stability by implementing thick, uniform HTLs.

14 SOLAR ENERGY

Exploring Ion Mobility Mass Spectrometry Data File Conversions to Leverage Existing Tools and Enable New Workflows

Ion mobility (IM) is often combined with LC-MS experiments to provide an additional dimension of separation for complex sample analysis. While highly complex samples are better characterized by the full dimensionality of LC-IM-MS experiments to uncover new information, downstream data analysis workflows are often not equipped to properly mine the additional IM dimension. For many samples the data acquisition benefits of including IM separations are all that is necessary to uncover sample information and the full dimensionality of the data is not required for data analysis. Post-acquisition reduction and adaptation of the dimensions of LC-IM-MS and IM-MS experiments into an LC-MS format opens the possibility to use a plethora of existing software tools. In this work, we developed data file conversion tools to reduce the complexity of IM data analysis. Three data file transformations are introduced in the PNNL PreProcessor software: 1) mapping the IM axis to the LC axis for IM-MS data, 2) converting the drift time vs. m/z space to CCS/z vs m/z space, and 3) transforming All Ions IM/MS mobility aligned fragmentation data to a standard LC-MS DDA data file format. Finally, these new data file conversions are demonstrated with corresponding lipidomics and proteomics workflows that leverage existing LC-MS data analysis software to highlight the benefits of the data transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Use of carbon electrodes to reduce mobile ion concentration and improve reliability of metal halide perovskite photovoltaics

Ion migration is one of the prime reasons for the rapid degradation of metal halide perovskite solar cells (PSCs), and we report on a method for quantifying mobile ion concentration (No) using a transient dark current measurement. We perform both ex-situ and in-situ measurements on PSCs and study the evolution of No in films and devices under a range of temperatures. We also study the effect of device architecture, top electrode chemistry, and metal halide perovskite composition and dimensionality on No. Two-dimensional perovskites are shown to reduce the ion concentration along with inert C electrodes that do not react with halides by ~99% while also improving mechanical reliability by ~250%. We believe this work can provide design guidelines for the development of stable PSCs through the lens of minimizing mobile ions and their evolution over time under operational conditions.

14 SOLAR ENERGY

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Revisiting the Role of Mobile Ion Size for the Activation Barrier of Charge Transport in Single Ion Conducting Polymers

The development of polymer electrolytes for energy storage and conversion technologies requires a fundamental understanding of the material parameters controlling the energy barriers for ion transport. In glassy polymers, these activation barriers are usually extracted by using Arrhenius procedures. However, our recent studies of single ion conducting polymers reveal that this traditional Arrhenius description provides anomalously small prefactors, an issue that is widely disregarded in the literature. Here, to address it, an alternative approach was introduced for extracting the effective activation barrier E by imposing a physically valid limit (∼10 –13 s) for the ion hopping attempt time. Two consequences of this recent approach are that in polymer electrolytes (i) E is significantly (∼30–40%) lower than the barrier estimated using traditional Arrhenius fits and (ii) E displays significant temperature dependence even in the glassy state. Under these circumstances, we are revisiting the role of ion size, glass transition temperature T g , and dielectric and elastic constants of the polymer matrix on the effective activation barriers for ion transport as extracted using the recently proposed approach and highlight the differences from the picture that previously emerged based on simplistic apparent Arrhenius analysis. To this end, we investigate cation transport in three families of single ion conducting trifluoromethane sulfonimide-based polyanions with varied T g . Our results indicate that E decreases with mobile cation size and is highly sensitive to changes in the dielectric permittivity of the matrix, even for large cations. These insights call for revisions of many earlier results based on apparent Arrhenius fits as the proposed approach can provide more accurate guidance for the design of polymer electrolytes with enhanced ionic conductivity.

energy barrier

Disentangling cation effects on ion mobility and structure in ionic liquid electrolytes

Ionic liquids (ILs) are low-temperature molten salts, where ion transport is primarily governed by ion–ion interactions. Yet, the impact of organic IL cations on critical electrolyte properties such as ion dissociation and overall transport behavior in lithium-salt-doped ILs remains poorly understood. Moreover, despite their critical role in designing IL-based electrolytes for energy storage applications, ion–ion interactions and ion-specific transport under an applied electrical potential are seldom quantified, largely due to the unique experimental and computational challenges involved. Herein, we compare transport properties obtained using 1 H, 7 Li, and 19 F pulsed-field gradient nuclear magnetic resonance (NMR) and electrophoretic NMR (eNMR) with those measured by electrochemical impedance spectroscopy. Non-equilibrium molecular dynamics (MD) simulations and eNMR confirm the presence of negatively charged [Li(TFSI) n ] (1−n) aggregates that migrate towards the positive electrode, resulting in negative lithium transference numbers. Equilibrium MD simulations reveal a vehicular Li ion transport mechanism facilitated by long-lived aggregates with Li + cations strongly bound to multiple TFSI − anions. Finally, we observe an inverse relationship between the apparent charge of the TFSI − anion in the neat IL, which is dictated by the IL cation, and Li + transport in the salt-doped systems. This highlights the opportunity to tune electrolyte performance by tailoring cation chemistry.

Li-ion batteries

Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

2-benzylbenzimidazoles, or “nitazenes”, are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20x more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path towards reference-free identification, which would greatly accelerate NSO identification rates in toxicology labs. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a Structures for Lossless Ion Manipulations (SLIM)-Orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and drug-like compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. In conclusion, the cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Heat Transfer Fluids as Co‐Diluents in Localized High‐Concentration Electrolytes for High‐Rate Lithium Metal Batteries With Enhanced Safety

Localized high-concentration electrolytes (LHCEs) have been identified as promising electrolyte formulations for lithium metal batteries, due to their effective interphase formation and promotion of compact Li deposition, yet their practical implementation is often limited by reduced ion transport kinetics. In this study, two industrially established fluorinated ethers are identified for the first time in battery research as effective co-diluents as they combine a broad electrochemical stability window with a low viscosity and intrinsic non-flammability. Incorporating these components, commonly used as heat transfer fluids, yields safer, less flammable electrolyte formulations with enhanced ion mobilities. In particular, the ternary co-diluent formulation shows improved ion mobility by reducing the electrolyte's viscosity while limiting excessive ion clustering. Based on the improved electrolyte transport kinetics, lower overvoltages and higher Coulombic efficiencies at current densities ≥ 1 mA cm −2 are achieved with the ternary co-diluent blend, resulting in markedly extended cycle life in an application-oriented zero-excess pouch cell compared with the baseline system. Complementary electrochemical and ex situ analysis of harvested electrodes at moderate current densities reveals no discernible differences in interphase morphology and composition, suggesting enhanced ion mobility as the primary cause of the improved high-rate performance.

electrolyte diluent

Dynamical Ion Correlations in Polymer and Membrane Electrolytes: Recent Advances and Open Questions

Ion transport in polymer and membrane electrolytes is often described using uncorrelated models like the Nernst–Einstein (NE) approximation, which link conductivity, transference number, and salt diffusivity to individual ion mobilities. However, growing evidence shows that dynamical ion correlations─arising from ion pairing, polymer-mediated coupling, confinement, and electrostatic interactions─can substantially alter macroscopic transport properties. The Onsager transport formalism offers a rigorous framework to quantify these effects via cross-correlated ionic displacements. This Perspective highlights how such correlations manifest across dry and hydrated systems, including salt-doped polymers, block copolymers, hydrogels, and ion-exchange membranes. Here, we examine key physical origins, the influence of salt chemistry and polymer structure, and open questions in measuring and controlling correlated motion. Embracing correlation-aware design enables new pathways to optimize conductivity, transference number, and selectivity─shifting the focus from individual ion mobility to engineered collective dynamics for next-generation electrolytes in energy storage and separations.

Charge transport

Theory of Ion-Mediated Segmental Localization, Activated Structural Relaxation, and the Glass Transition in Polymerized Ionic Liquids

Here we combine polymer integral equation theory for structural correlations with a force-level theory for activated segmental relaxation to construct a microscopic theory for how ions modify the onset of segmental localization, the polymer alpha relaxation time, and glass transition temperature, T g , in dry polymerized ionic liquids (PolyILs). Our most important findings concerning the behavior of T g are (i) a weak dependence on anion–cation Coulomb attraction strength due to strong decoupling of ion and segmental dynamics, (ii) strong reduction with increasing mobile ion size due to both plasticization effects and weakening of ion-modified monomer caging, and (iii) increase with backbone rigidity and intrachain dynamic cooperativity. We quantitatively estimate T g variations as ion size and polymer static and dynamic rigidity are widely varied. The experimental data of 19 PolyILs are organized into a specific pattern consistent with the theoretical predictions with glass transition temperatures varying over a very wide range (~250 K) as observed experimentally. Based on the theoretical results, suggestions are made concerning the search for high conductivity Li- or Na-based PolyILs based on further lowering of T g via new polymer synthesis. Calculations of the alpha time as a function of packing fraction reveal the dynamic fragility increases for larger mobile ions, a more flexible backbone, and/or a smaller degree of intrachain dynamic cooperativity, as a consequence of the increasing importance of collective elasticity in determining the activation barrier. An analysis of transient segmental localization and a crossover to activated dynamics reveals similar, but not identical, trends as predicted at the laboratory vitrification timescale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Investigation of two-dimensional radio-frequency sheath properties using a microscale fluid model

Abstract In previous work (Kohno and Myra 2023 Comput. Phys. Commun. 291 108841), we developed a numerical scheme based on a two-dimensional microscale radio-frequency (RF) sheath model with periodically curved wall boundaries. Here, we expand the capability of this scheme through modification of the boundary conditions (BCs) on the conducting walls, which allows the ion flow to turn back to the plasma at locations on the walls where the electromagnetic force on the ions is reversed from its usual direction. Numerical simulations are carried out to investigate the dependences of the surface-integrated admittances on the wall bump height, ion magnetization, ion mobility, and the magnetic field angle, and to visualize the sheath structures in several cases. One of the main results is the ion cyclotron admittance resonance observed under the condition of low ion mobility (high normalized frequency). It is shown that the amplitude of the resonance peak depends on the wall bump height and the ion velocity is reversed on the sides of the bump in an RF cycle for the resonance cases. Furthermore, the differences in the admittances between the one- and two-dimensional microscale models are assessed for the purpose of understanding non-locality of the sheath near the wall surface for the parameters considered in this study. This information will be essential for improving the sheath BC for macroscale calculations in the future.

Kohno, H. (ORCID:0000000332690010)

Stabilizing Iodine in 2D Mixed Halide Perovskites: Dion–Jacobson Versus Ruddlesden–Popper Phases

Iodine electrochemistry plays an important role in driving iodide‐oxidation induced halide migration in 3D halide perovskites. When subjected to light illumination or electrochemical bias, mixed halide perovskites undergo halide segregation followed by iodine expulsion from the crystal lattices. To mitigate such intrinsic halide ion mobility in 3D perovskites, lower‐dimensional (2D) perovskites are employed as barriers to stabilize the perovskite layers. Interestingly, 2D halide perovskites also exhibit halide ion mobility that is dependent on the binding configuration, viz., Ruddlesden–Popper (RP) and Dion–Jacobson (DJ) phases. Hybrid RP‐DJ perovskites with a mixed Br:I ratio of 50:50 show increased stability following continuous photoirradiation. Spectroscopic studies that probe iodine migration and expulsion in photoirradiated 2D films of different configurations are presented here. The effective strategy of blending two different 2D phases (RP‐DJ) offers new opportunities to develop stable 2D/3D perovskite interfaces in solar cells.

2D halide perovskites