Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The role of fiber optics in mass spectrometer electro-optical ion detection

This paper describes the development of an electro-optical ion detector combining the best features of photographic and electrical ion detection (i.e., wide mass range coverage and low ion detection threshold respectively). A nineteen fold fiber optic image dissector is discussed which reformats the 1 mm x 361 mm mass spectrometer focal plane format to a 19 mm x 19 mm format suitable for vidicon imaging and electronic display of the data.

Norris, D. D.↗

Superthermal ions detected in Venus' dayside ionosheath, ionopause, and magnetic barrier regions

Results of a comprehensive morphological analysis of the dayside superthermal ion presence in the dayside ionopause region of Venus made using the Orbiter Ion Mass Spectrometer measurements are presented. There is a strong inbound-outbound difference in both the number and intensity of the superthermal ions with most events detected on the inbound crossing of the ionopause. The ambient energy of the detected ions is comparable to the ram energy of cold ions relative to the moving spacecraft. A comparison of the locations of the superthermal O(+) ion occurrences with respect to other parameters shows that the superthermals are a characteristic of the ionopause transition separating the essentially stationary ionosphere plasma from the flowing ionosheath plasma as deduced by Taylor et al. (1980) from individual examples.

Grebowsky, J. M.↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Higher-Sensitivity Ionization Trace-Species Detector

Electron source and electron optics of reversal electron-attachment detector modified to increase sensitivity. Original version described in "High-Sensitivity Ionization Trace-Species Detector" (NPO-17596). Used to detect molecules of particular chemical species of interest (e.g., narcotics, explosives, or organic wastes) present in air at low concentrations, and known to attach extremely low-energy electrons. Apparatus does this by ionizing molecules from sampled atmosphere, then detecting ions of species of interest. Detector features indirectly heated spherical cathode and redesigned electron optics, together, deliver more electrons at low kinetic energy to reversal plane, R. Greater electron current generates more ions for detection.

Boumsellek, Said↗

Ion and electron detector for use in an ICR spectrometer

A detector for detecting ions and/or electrons present in a resonance cell of an ICR spectrometer is disclosed. The detector which operates on the Q-meter principle is driven by an external rf oscillator capable of providing rf frequencies up to about 15MHz at an adjustable low rf signal level, e.g., below 20mV. The detector is connected across the resonance of the cell to detect ions by detecting their cyclotron frequency. Electrons are detectable by connecting the detector across the cell's trapping plates and thereby detect the electrons' trapping motion, the frequency of which is in the megahertz range.

Huntress, W. T.↗

Unveiling Venus with VOIR

The goals and intended capabilities of the Venus Orbiting Imaging Radar (VOIR), scheduled for launch in the mid-1980's, are reviewed. Current Pioneer Venus Orbiter data is considered of unsufficient resolution for actual planetary mapping of the geologic terrain of Venus, while the VOIR possesses an SAR which is able to provide a 600 m line pair resolution. The data would yield information of small-scale roughness and the rms slope of surface features, would serve as an efficient altimeter, and help track the planet's gravity field to within 1/5000 cm/sec resolution. Estimations of wind velocity and turbulence would be made available, and a Langmuir probe, a quadrupole mass analyzer, and an ion analyzer will detect ions, electrons, elemental compositions, concentrations, and densities, as well as velocities.

James, W.↗

Pickup Ions at Dione and Enceladus

Voyager images of the icy satellites of Saturn, Dione and Enceladus, suggest they have been geologically active and are not only composed of ice. Recent observations by HST have shown the presence of ozone at both Dione and Rhea which also implies the presence of molecular oxygen at these bodies. The Cassini Plasma Spectrometer (CAPS) will provide the capability to determine the global composition of these bodies by measuring the pickup ions produced by the ionization of their sputter produced atmospheres. We will present a model of these atmospheres and associated pickup ions and demonstrate CAPS ability to distinguish the freshly produced picked up ions from the ambient plasma. Such ions are expected to form a ring distribution that will have a uniquely different energy-angle dependence than the ambient plasma ions. In the case of Dione we expect the potential for a moderate strength interaction for which both Voyager 1 and Pioneer 11 spacecraft measured ion cyclotron waves centered on the Dione L shell and near the equatorial plane. Since Enceladus may be the source of the E-ring, some surprises may be encountered during its close encounter with the Cassini spacecraft. In the case of Dione we will show that a wake pass at 500 km altitude is more than an order of magnitude better than an upstream pass at 500 km altitude. Pickup ion detection for minor ion species such as NH3+ is possible for 500 km altitude wake pass but not for a 500 km altitude upstream pass at closest approach. For navigation reasons a 100 km pass is not allowed and therefore it is essential to have a wake pass to maximize the science return for a targeted flyby with Dione. The CAPS observations when combined with magnetometer, plasma wave and energetic particle observations will allow us to estimate the source of ions into Saturn's magnetosphere due to these two bodies and to characterize the nature of the interaction with Saturn's magnetosphere.

Sittler, E.↗

On the possibility of detection of ions from Venus at 1 AU

The possibility that single ionized helium enhancements observed near 1 AU are the result of ion pickup from Venus is analyzed and found to be implausible. It is still possible, however, that Venus ions are present in the solar wind with sufficiently high fluxes to be detectable by earth-orbiting satellites near the time of inferior conjunction. Because of the inclination of the orbit of Venus to the ecliptic, some inferior conjunctions are more favorable for such a search than others. The inferior conjunctions on June 17, 1972 and June 15, 1980 are most favorable for detection.

Russell, C. T.↗

The source of midlatitude metallic ions at F-region altitudes

The results of a survey of metallic ions detected by the Bennett Ion Mass Spectrometer flown on the Atmospheric Explorer satellites are presented and discussed. The nighttime distribution of these ions observed in the F-region at middle latitudes can be accounted for by the presence of fast upward Pederson ion drifts that are produced by intense poleward-directed electric fields with magnitudes typical of those defining subauroral drift events. Such fields, which arise in the vicinity of the main electron density trough at night, result in the rapid movement of long-lived meteoric ions upwards out of their source region into the F-region. Neutral wind drag by the equatorially-directed nightside neutral wind component can lift the ions higher along the field lines until the downward drag of major ion diffusion forces them to layer under F-max.

Grebowsky, J. M.↗

Mass spectrometry and inhomogeneous ion optics

Work done in several areas to advance the state of the art of magnetic mass spectrometers is described. The calculations and data necessary for the design of inhomogeneous field mass spectrometers, and the calculation of ion trajectories through such fields are presented. The development and testing of solid state ion detection devices providing the capability of counting single ions is discussed. New techniques in the preparation and operation of thermal-ionization ion sources are described. Data obtained on the concentrations of copper in rainfall and uranium in air samples using the improved thermal ionization techniques are presented. The design of a closed system static mass spectrometer for isotopic analyses is discussed. A summary of instrumental aspects of a four-stage mass spectrometer comprising two electrostatic and two 90 deg. magnetic lenses with a 122-cm radius used to study the interaction of ions with solids is presented.

White, F. A.↗

Suprathermal ions near the moon.

This paper reports some preliminary results from the suprathermal ion detectors deployed on the lunar surface by the Apollo 12 and 14 astronauts. Salient features of these results include: the possible observation of sporadic venting of gas from the lunar surface; evidence for a prompt ionization and acceleration mechanism operating in the lunar exosphere; and a preliminary measurement yielding approximately 1 month for the e-folding decay time for the heavier components of the exhaust gases from the Apollo lunar landing systems. Prominent phenomena from which these results have been derived are: (1) ion bursts of low to moderate energy seen in conjunction with lunar sunrise and sunset; (2) solar wind energy ions detected on the night side of the moon; (3) ions of several keV energy seen during the lunar sunset to midnight quadrant of the moon's orbit; (4) magnetosheath ion flux enhancements; (5) ion bursts generated by the lunar impact of the Apollo 13 Saturn upper stage; and (6) geomagnetic storm associated ion flux variations in the earth's magnetotail.

Freeman, J. W., Jr.↗

A novel approach to increasing cocaine detection confidence utilizing ion mobility spectrometry

When a positive detection of a narcotic occurs during the search of a vessel, a decision has to be made whether further intensive search is warranted. In terms of unwarranted delays of vessels and possible property damage, the accuracy of the analytical determination is very important. Analytical accuracy becomes critical when the data may be used in court actions as evidence. For this purpose, the U.S. Coast Guard has been investigating several confirmatory ion mobility spectrometry (IMS) field methods for the detection and identification of cocaine. This paper presents the findings of our investigations on the use of catalytic pyrolysis and base hydrolysis as confirmatory methods. The catalytic effects of various metals on the pyrolysis reaction are reported. In addition, the effects of several different ion mobility spectrometer sample transfer mediums and varying laboratory conditions on the base hydrolysis of the cocaine molecule are also be reported.

Jadamec, J. Richard↗

On the detection of lunar volatile emissions

This letter shows that the Apollo lunar-surface Suprathermal Ion Detection Experiment (SIDE) instruments lack the sensitivity to detect even large emissions of radiogenic gases from the moon if the venting of these gases occurs primarily at a few-well-defined sites of lunar transient phenomena (LTPs). It is suggested that specific flight instruments for the proposed ESA Polar Orbiting Lunar Observatory (POLO) mission, which could detect active venting, would help determine the energy source for LTPs and would increase knowledge of lunar geophysics. A critical-velocity model for the LTP energy source is briefly discussed.

Srnka, L. J.↗

Energetic neutral atom image of a storm-time ring current

Energetic neutral atom (ENA) images of a storm-time ring current produced from direct measurements and model simulations are presented and analyzed. An ENA image of the storm-time ring current was obtained with the Medium Energy Particles Instrument (MEPI) mounted on ISEE 1 on September 29, 1978, and a zero-order model of the ring current ion was employed to simulate the ENA image. The simulated instrument response is compared with actual ENA measurements. It is observed that the spatial distribution of singly charged ions detected from the ENA images displays equatorial midnight/noon asymmetry in differential ion intensity with a midnight/noon ratio of greater than or equal to 20:1; peak ion fluxs, H(+) and O(+), in the midnight sector are greater than 10 to the 6th/(sq cm s sr keV); and ENA fluxes from the brighter areas of the image exceed greater than 1000/(sq cm s sr keV). It is noted that the ENA image from MEPI data correlates with the morphology of the simulated response of MEPI calculated from the model.

Roelof, Edmond C.↗