Results for “ION DENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Examination of ionic wind and cathode sheath effects in a E-field premixed flame with ion density measurements

The effect of the ionic wind on a premixed methane-air flame under a DC electric field is studied via mapping of the ion density with Langmuir probes. Ion densities were observed to increase near the burner with increasing electrode voltage up to 6 kV. Past this electrode supply voltage, ion densities ceased increasing and began to decline in some locations within the premixed flame. The increased ion density is caused by an increase in ionic wind force and cathode sheath thickness. The plateau in density is due to the cathode sheath fully encompassing the flame front which is the ion source, thereby collecting all ions in the flame. The spatial density data support the ionic wind hypothesis and provide further explanation of its limits based on the plasma sheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially resolved measurements of ion density and electron temperature in a dual-frequency capacitively coupled plasma by complete floating double probe technique

Spatially resolved measurements of the ion density and electron temperature in a dual-frequency capacitively coupled Ar discharge plasma are performed with a newly developed complete floating double probe. Axial and radial distributions of the ion density and electron temperature under various high-frequency (HF) power and gas pressure were studied in detail. Both the ion density and the electron temperature increased with increasing HF power. With increasing gas pressure from 1.3 to 9.3 Pa, the radial profile of ion density below the driven electrode experienced a change from ''bimodal'' to ''unimodal'' shape, with better uniformity being achieved at the optimal pressure of about 5 Pa. In addition, changing the axial profile of ion density was also observed with the peak shift toward the powered electrode at higher pressures. The measured results showed satisfying consistency with that of improved two dimensional fluid simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization of plasma parameters with magnetic filter field and pressure to maximize H{sup −} ion density in a negative hydrogen ion source

Transverse magnetic filter field as well as operating pressure is considered to be an important control knob to enhance negative hydrogen ion production via plasma parameter optimization in volume-produced negative hydrogen ion sources. Stronger filter field to reduce electron temperature sufficiently in the extraction region is favorable, but generally known to be limited by electron density drop near the extraction region. In this study, unexpected electron density increase instead of density drop is observed in front of the extraction region when the applied transverse filter field increases monotonically toward the extraction aperture. Measurements of plasma parameters with a movable Langmuir probe indicate that the increased electron density may be caused by low energy electron accumulation in the filter region decreasing perpendicular diffusion coefficients across the increasing filter field. Negative hydrogen ion populations are estimated from the measured profiles of electron temperatures and densities and confirmed to be consistent with laser photo-detachment measurements of the H{sup −} populations for various filter field strengths and pressures. Enhanced H{sup −} population near the extraction region due to the increased low energy electrons in the filter region may be utilized to increase negative hydrogen beam currents by moving the extraction position accordingly. This new finding can be used to design efficient H{sup −} sources with an optimal filtering system by maximizing high energy electron filtering while keeping low energy electrons available in the extraction region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed measurements of neutral beam turn-on and impact of beam modulation on measurements of ion density

Modulation of neutral beams on tokamaks is performed routinely, enabling background rejection for active spectroscopic diagnostics, and control of injected power and torque. We find that there exists an anomalous initial transient in the beam neutrals delivered to the tokamak that is not accounted for by the accelerator voltage and power supply current. Measurements of the charge-exchange and beam photoemission on the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] at high speed (200 μs) reveal that the energy of the beam neutrals is constant, but the density of beam neutrals displays dramatic variation in the first 2–3 ms following beam turn-on. The impact of this beam density variation on inferred ion densities and impurity transport is presented, with suggested means to correct for the anomalous transient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The use of geometric effects in diagnosing ion density in ICF-related dot spectroscopy experiments

Here, we describe a method to calculate the ion density of High Energy Density (HED) cylindrical plasmas used in dot spectroscopy experiments. This method requires only spectroscopic measurements of the Heα region obtained from two views (Face-on and Side-on). We make use of the fact that the geometry of the plasma affects the observed flux of optically thick lines. The ion density can be derived from the aspect ratio (height-to-radius) of the cylinder and the optical depth of the Heα-y line (1s2p 3 P 1 → 1s 2 1 S 0 ). The aspect ratio and the optical depth of the y line are obtained from the spectra using ratios measured from the two directions of emission of the optically thick Heα-w line (1s2p 1 P 1 → 1s 2 1 S 0 ) and the ratio of the optically thick to thin lines. The method can be applied to mid-Z elements at ion densities of 10 19 – 10 20 cm -3 and temperatures of a the order of keV, which is a relevant regime for Inertial Confinement Fusion (ICF)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosis of the ion density in two discharge modes generated in atmospheric pressure argon with pin-to-plate dielectric barrier geometry

In this study, the ion densities of an ac dielectric barrier discharge (DBD) (that is, a pin-to-plate DBD) as a function of the applied frequency in argon have been studied by means of the plasma radiation. The pin-to-plate DBD shows the characteristic of radiation oscillations with a low-frequency wave hidden in a high-frequency wave to form a mosaic structure, which reveals the coexistence of two discharge modes in the ac barrier discharge, i.e., the streamer mode and the corona mode. According to the oscillation frequencies, the ion densities are calculated. The results show that the ion density in streamer discharge is higher than that in corona discharge for about 1-2 magnitude orders.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonance hairpin and Langmuir probe-assisted laser photodetachment measurements of the negative ion density in a pulsed dc magnetron discharge

The time-resolved negative oxygen ion density n{sub -} close to the center line in a reactive pulsed dc magnetron discharge (10 kHz and 50% duty cycle) has been determined for the first time using a combination of laser photodetachment and resonance hairpin probing. The discharge was operated at a power of 50 W in 70% argon and 30% oxygen gas mixtures at 1.3 Pa pressure. The results show that the O{sup -} density remains pretty constant during the driven phase of the discharge at values typically below 5x10{sup 14} m{sup -3}; however, in the off-time, the O{sup -} density grows reaching values several times those in the on-time. This leads to the negative ion fraction (or degree of electronegativity) {alpha}=n{sub -}/n{sub e} being higher in the off phase (maximum value {alpha}{approx}1) than in the on phase ({alpha}=0.05-0.3). The authors also see higher values of {alpha} at positions close to the magnetic null than in the more magnetized region of the plasma. This fractional increase in negative ion density during the off-phase is attributed to the enhanced dissociative electron attachment of highly excited oxygen molecules in the cooling plasma. The results show that close to the magnetic null the photodetached electron density decays quickly after the laser pulse, followed by a slow decay over a few microseconds governed by the negative ion temperature. However, in the magnetized regions of the plasma, this decay is more gradual. This is attributed to the different cross-field transport rates for electrons in these two regions. The resonance hairpin probe measurements of the photoelectron densities are compared directly to photoelectron currents obtained using a conventional Langmuir probe. There is good agreement in the general trends, particularly in the off-time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of measured and modelled negative hydrogen ion densities at the ECR-discharge HOMER

As the negative hydrogen ion density n{sub H{sup −}} is a key parameter for the investigation of negative ion sources, its diagnostic quantification is essential in source development and operation as well as for fundamental research. By utilizing the photodetachment process of negative ions, generally two different diagnostic methods can be applied: via laser photodetachment, the density of negative ions is measured locally, but only relatively to the electron density. To obtain absolute densities, the electron density has to be measured additionally, which induces further uncertainties. Via cavity ring-down spectroscopy (CRDS), the absolute density of H{sup −} is measured directly, however LOS-averaged over the plasma length. At the ECR-discharge HOMER, where H{sup −} is produced in the plasma volume, laser photodetachment is applied as the standard method to measure n{sub H{sup −}}. The additional application of CRDS provides the possibility to directly obtain absolute values of n{sub H{sup −}}, thereby successfully bench-marking the laser photodetachment system as both diagnostics are in good agreement. In the investigated pressure range from 0.3 to 3 Pa, the measured negative hydrogen ion density shows a maximum at 1 to 1.5 Pa and an approximately linear response to increasing input microwave powers from 200 up to 500 W. Additionally, the volume production of negative ions is 0-dimensionally modelled by balancing H{sup −} production and destruction processes. The modelled densities are adapted to the absolute measurements of n{sub H{sup −}} via CRDS, allowing to identify collisions of H{sup −} with hydrogen atoms (associative and non-associative detachment) to be the dominant loss process of H{sup −} in the plasma volume at HOMER. Furthermore, the characteristic peak of n{sub H{sup −}} observed at 1 to 1.5 Pa is identified to be caused by a comparable behaviour of the electron density with varying pressure, as n{sub e} determines the volume production rate via dissociative electron attachment to vibrationally excited hydrogen molecules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of ion density in an atmospheric pressure argon with pin-to-plate dielectric barrier discharge by resonance of plasma radiation

The measurements of the ion densities in the atmospheric AC barrier corona argon discharge are carried out by receiving and analyzing the frequencies of the electromagnetic radiation emitted from the plasma. An auxiliary excitation source composed of a pin-to-pin discharge system is introduced to excite the oscillations of the main discharge. To analyze the resonance mechanism, a complemented model based on a one-dimensional description of forced vibrations is given. Calculations indicate that Ar{sub 2}{sup +} is the dominant ion (∼89% in number density). By analyzing resonance frequencies, the ion densities of Ar{sub 2}{sup +} are in the order of 10{sup 19}∼10{sup 20}m{sup −3} and increase slowly as the applied voltage increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast wave interferometer for ion density measurement on DIII-D

=A fast wave interferometer (FWI), which can measure ion mass density, has been developed on DIII-D for its use on future fusion reactors, as well as for the study of ion behavior in current plasma devices. The frequency of the fast waves used for the FWI is around 60 MHz, and require antennas and coaxial cables or waveguides, which, unlike traditional mirror-based optical interferometers, are less susceptible to neutron/gamma-ray radiation and are relatively immune to impurity deposition and erosion as well as alignment issues. The bulk ion density evaluated using FWI show good agreement with that derived from CO 2 interferometry within about 15%. When the ion mass density measurement by FWI is combined with an electron density measurement from CO 2 interferometry, Z eff measurements are also enabled and are in agreement with those from visible Bremsstrahlung measurements. Additionally, large-bandwidth FWI measurements clearly resolve 10–100 kHz coherent modes and demonstrate its potential as a core fluctuation diagnostic, sensitive to both magnetic and ion density perturbations.

Instruments & Instrumentation↗

Measurement of electron temperature and ion density using the self-bias effect in plasmas

For novel plasma diagnostics, the rf floating probe was revisited. For inducing the self-bias effect, ac bias voltage (approxkilohertz) was applied through a dc blocking capacitor between a probe and a signal generator. The dc self-bias potential was changed not only with ac bias voltages but also with electron temperatures, and therefore, the electron temperature was derived from the variations in the self-bias potential with and without ac bias voltage. The harmonic component of the probe contains information about the ion flux, and using a fast Fourier transform analysis of the probe current, the ion density was derived from the first harmonic current of the probe. The experimental results were compared with a single Langmuir probe. The electron temperature and the ion density were in good agreement with those from the Langmuir probe. Because the amplitude of the ac bias voltage is very low (<3 V), local ionizations affected by a high bias-voltage can be neglected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Is the Local Ion Density Sufficient to Drive NaCl Nucleation from the Melt and Aqueous Solution?

Even though nucleation is ubiquitous in different science and engineering problems, investigating nucleation is extremely difficult due to the complicated ranges of time and length scales involved. In this work, we simulate NaCl nucleation in both molten and aqueous environments using enhanced sampling of all-atom molecular dynamics with deep-learning-based estimation of reaction coordinates. By incorporating various structural order parameters and learning the reaction coordinate as a function thereof, we achieve significantly improved sampling relative to traditional ad hoc descriptions of what drives nucleation, particularly in an aqueous medium. Our results reveal a one-step nucleation mechanism in both environments, with reaction coordinate analysis highlighting the importance of local ion density in distinguishing solid and liquid states. However, although fluctuations in the local ion density are necessary to drive nucleation, they are not sufficient. Our analysis shows that near the transition states, descriptors such as enthalpy and local structure become crucial. Furthermore, our protocol proposed here enables robust nucleation analysis and phase sampling and could offer insights into nucleation mechanisms for generic small molecules in different environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative determination of mass-resolved ion densities in H{sub 2}-Ar inductively coupled radio frequency plasmas

Inductively coupled H{sub 2}-Ar plasmas are characterized by an energy-dispersive mass spectrometer (plasma monitor), a retarding field analyzer, optical emission spectroscopy, and a Langmuir probe. A procedure is presented that allows determining quantitatively the absolute ion densities of Ar{sup +}, H{sup +}, H{sub 2}{sup +}, H{sub 3}{sup +}, and ArH{sup +} from the plasma monitor raw signals. The calibration procedure considers the energy and mass-dependent transmission of the plasma monitor. It is shown that an additional diagnostic like a Langmuir probe or a retarding field analyzer is necessary to derive absolute fluxes with the plasma monitor. The conversion from fluxes into densities is based on a sheath and density profile model. Measurements were conducted for a total gas pressure of 1.0 Pa. For pure H{sub 2} plasmas, the dominant ion is H{sub 3}{sup +}. For mixed H{sub 2}-Ar plasmas, the ArH{sup +} molecular ion is the most dominant ion species in a wide parameter range. The electron density, n{sub e}, is around 3 Multiplication-Sign 10{sup 16} m{sup -3} and the electron temperature, T{sub e}, decreases from 5 to 3 eV with increasing Ar content. The dissociation degree was measured by actinometry. It is around 1.7% nearly independent on Ar content. The gas temperature, estimated by the rotational distribution of the Q-branch lines of the H{sub 2} Fulcher-{alpha} diagonal band (v Prime =v Double-Prime =2) is estimated to (540 {+-} 50) K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dusty plasma diagnostics methods for charge, electron temperature, and ion density

Diagnostic methods are developed to measure the microparticle charge Q and two plasma parameters, electron temperature T{sub e}, and ion density n{sub i}, in the main plasma region of a dusty plasma. Using video microscopy to track microparticles yields a resonance frequency, which along with a charging model allows an estimation of Q and T{sub e}. Only measurements of microparticle position and velocity are required, unlike other methods that use measurements of T{sub e} and plasma parameters as inputs. The resonance frequency measurement can also be used with an ion drag model to estimate n{sub i}. These methods are demonstrated using a single-layer dusty plasma suspension under microgravity conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stabilization of Alfvén Eigenmodes in DIII-D via Controlled Energetic Ion Density Ramp and Validation of Theory and Simulations

In this work, fast-ion driven Alfvén waves with frequency close to the ion cyclotron frequency (ƒ = 0:58ƒ ci ) excited by energetic ions from a neutral beam are stabilized via a controlled energetic ion density ramp for the first time in a fusion research plasma. The scaling of wave amplitude with injection rate is consistent with theory for single mode collisional saturation near marginal stability. The wave is identified as a shear-polarized global Alfvén eigenmode excited by Doppler-shifted cyclotron resonance with fast-ions with sub-Alfvénic energetic ions, a first in fusion research plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of ion density distribution by magnetic traps for plasma electrons

The effect of a magnetic field of two magnetic coils on the ion current density distribution in the setup for low-temperature plasma deposition is investigated. The substrate of 400 mm diameter is placed at a distance of 325 mm from the plasma duct exit, with the two magnetic coils mounted symmetrically under the substrate at a distance of 140 mm relative to the substrate centre. A planar probe is used to measure the ion current density distribution along the plasma flux cross-sections at distances of 150, 230, and 325 mm from the plasma duct exit. It is shown that the magnetic field strongly affects the ion current density distribution. Transparent plastic films are used to investigate qualitatively the ion density distribution profiles and the effect of the magnetic field. A theoretical model is developed to describe the interaction of the ion fluxes with the negative space charge regions associated with the magnetic trapping of the plasma electrons. Theoretical results are compared with the experimental measurements, and a reasonable agreement is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of low-energy and high-current-density ion beam system

A low-energy ion beam system operating at a dc voltage of less than 300 V was developed using an ion source with a multicusp magnetic field. A high-current-density ion beam of 6.9 mA/cm{sup 2} was successfully extracted at the electrode. The beam extraction characteristics for flat and concave electrodes were compared. In the case of a concave electrode with a designed focal length of 350 mm, it was observed that the beam profile was sharper than that obtained using a flat electrode.