Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization of applied fields for ion mobility separations in traveling wave based structures for lossless ion manipulations (SLIM)

Ion mobility (IM) is rapidly gaining attention for the analysis of biomolecules due to the ability to distinguish the shapes of ions. However, conventional constant electric field drift tube IM has limited resolving power, constrained by practical limitations on the path length and maximum applied voltage. The implementation of traveling waves (TW) in IM removes the latter limitation, allowing higher resolution to be achieved using extended path lengths. These can be readily obtainable in structures for lossless ion manipulations (SLIM), which are fabricated from electric fields that are generated by appropriate potentials applied to arrays of electrodes patterned on two parallel surfaces. In this work we have investigated the relationship between the various SLIM variables, such as electrode dimensions, inter-surface gap, and the TW applied voltages, that directly impact the fields experienced by ions. Ion simulation and theoretical calculations have been utilized to understand the dependence of SLIM geometry and effective electric field. The variables explored impact both ion confinement and the observed IM resolution in Structures for Lossless Ion Manipulations (SLIM) modules.

Hamid, Ahmed M.↗

Laser ion source for isobaric heavy ion collider experiment

Heavy-ion collider experiment in isobaric system is under investigation at Relativistic Heavy Ion Collider. For this experiment, ion source is required to maximize the abundance of the intended isotope. The candidate of the experiment is {sup 96}Ru + {sup 96}Zr. Since the natural abundance of particular isotope is low and composition of isotope from ion source depends on the composites of the target, an isotope enriched material may be needed as a target. We studied the performance of the laser ion source required for the experiment for Zr ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Hybrid Constant and Oscillatory Field Ion Mobility Analyzer Using Structures for Lossless Ion Manipulations

Here we explore the combination of constant and oscillatory fields applied in a single device to affect the continuous separation and filtering of ions based on their mobilities. The device explored allows confining and manipulating ions utilizing a combination of radio frequency (rf), direct current (DC) fields, and traveling waves (TW) in a structures for lossless ion manipulations (SLIM) module. We have investigated theoretically and experimentally a concept for continuous filtering of ions based on their mobilities where ions are mobility separated and selected by passage through two regions, both of which incorporated combined TW and constant fields providing opposing forces on the ions. The SLIM module was composed of two surfaces with mirror-image arrays of electrodes and had two regions where the different TW and opposing DC fields could be applied. The filtering capabilities are determined by the applied DC gradient and the TW parameters, such as speed, amplitude, and the TW sequence (i.e., the duty cycle of the traveling wave). The effects of different parameters on the sensitivity and the ion mobility (IM) resolution of the device have been investigated. By appropriately choosing the DC gradient and TW parameters for the two sections, it is possible to transmit ions of a selected mobility while filtering out others of both higher and lower mobility. The novel device described here provides a basis for the targeted analysis of compounds based upon the continuous selection of ions according to their mobility and without the need for high electric fields or pulsed injection. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a beam ion velocity detector for the heavy ion beam probe

In an axisymmetric plasma, the conservation of canonical angular momentum constrains heavy ion beam probe (HIBP) trajectories such that measurement of the toroidal velocity component of secondary ions provides a localized determination of the poloidal flux at the volume where they originated. We have developed a prototype detector which is designed to determine the beam angle in one dimension through the detection of ion current landing on two parallel planes of detecting elements. A set of apertures creates a pattern of ion current on wires in the first plane and solid metal plates behind them; the relative amounts detected by the wires and plates determine the angle which beam ions enter the detector, which is used to infer the toroidal velocity component. The design evolved from a series of simulations within which we modeled ion beam velocity changes due to equilibrium and fluctuating magnetic fields, along with the ion beam profile and velocity dispersion, and studied how these and characteristics such as the size, cross section, and spacing of the detector elements affect performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compression Ratio Ion Mobility Programming (CRIMP) Accumulation and Compression of Billions of Ions for Ion Mobility-Mass Spectrometry Using Traveling Waves in Structures for Lossless Ion Manipulations (SLIM)

We report on the implementation of a traveling wave (TW) based compression ratio ion mobility programming (CRIMP) approach within Structures for Lossless Ion Manipulations (SLIM) that enables both greatly enlarged trapped ion charge capacities and also their subsequent efficient compression for use in ion mobility (IM) separations. Ion accumulation is conducted in a long serpentine path TW SLIM region after which CRIMP allows the large ion populations to be ‘squeezed’. The compression process occurs at an interface between two SLIM regions, one operating conventionally and the second having an intermittently pausing or ‘stuttering’ TW, allowing the contents of multiple bins of ions from the first region to be merged into a single bin in the second region. In this initial work stationary voltages in the second region were used to block ions from exiting the first (trapping) region, and the resumption of TWs in the second region allows ions to exit, and the population to also be compressed if CRIMP is applied. In our initial evaluation we show that the number of charges trapped for a 40 s accumulation period was ~5×109, more than two orders of magnitude greater than the previously reported charge capacity using an ion funnel trap. We also show that over 1×109 ions can be accumulated with high efficiency in the present device, and that the extent of subsequent compression is only limited by the space charge capacity of the trapping region. Lower compression ratios allow increased IM peak heights without significant loss of signal, while excessively large compression ratios can lead to ion losses and other artifacts. Importantly, we show that extended ion accumulation in conjunction with CRIMP and multiple passes provides the basis for a highly desirable combination of ultra-high sensitivity and ultra-high resolution IM separations using SLIM.

Environmental Molecular Sciences Laboratory↗

Temporal evolution of ion energy distribution functions and ion charge states of Cr and Cr-Al pulsed arc plasmas

To study the temporal evolution of ion energy distribution functions, charge-state-resolved ion energy distribution functions of pulsed arc plasmas from Cr and Cr-Al cathodes were recorded with high time resolution by using direct data acquisition from a combined energy and mass analyzer. The authors find increases in intensities of singly charged ions, which is evidence that charge exchange reactions took place in both Cr and Cr-Al systems. In Cr-Al plasmas, the distributions of high-charge-state ions exhibit high energy tails 50 μs after discharge ignition, but no such tails were observed at 500 μs. The energy ratios of ions of different charge states at the beginning of the pulse, when less neutral atoms were in the space in front of the cathode, suggest that ions are accelerated by an electric field. The situation is not so clear after 50 μs due to particle collisions. The initial mean ion charge state of Cr was about the same in Cr and in Cr-Al plasmas, but it decreased more rapidly in Cr-Al plasmas compared to the decay in Cr plasma. The faster decay of the mean ion charge state and ion energy caused by the addition of Al into a pure Cr cathode suggests that the mean ion charge state is determined not only by ionization processes at the cathode spot but also by inelastic collision between different elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

From Isolated Ions to Multilayer Functional Materials Using Ion Soft Landing

The ability to deposit intact polyatomic ions with well-defined composition, charge state, and kinetic energy onto surfaces makes preparative mass spectrometry, also called ion soft-landing, particularly attractive for preparing uniform molecular and ionic layers. Early studies characterized structures, charge states, and reactivity of sparsely distributed soft-landed species. Recent development of high-flux ionization sources has opened up new opportunities for the precisely-controlled preparation of both two-dimensional assemblies and three-dimensional multilayer architectures using ion soft-landing. Previously unknown phenomena have been uncovered following deposition of large numbers of ions onto supports thereby opening several exciting research directions in this field. Furthermore, faster ion deposition has enabled fabrication of novel functional devices. This review discusses important phenomena and highlights key developments pertaining to preparation of well-defined interfaces for studies in energy storage, catalysis, soft materials, and biology.

Laskin, Julia↗

Molecular ion sources for low energy semiconductor ion implantation (invited)

Smaller semiconductors require shallow, low energy ion implantation, resulting space charge effects, which reduced beam currents and production rates. To increase production rates, molecular ions are used. Boron and phosphorous (or arsenic) implantation is needed for P-type and N-type semiconductors, respectively. Carborane, which is the most stable molecular boron ion leaves unacceptable carbon residue on extraction grids. A self-cleaning carborane acid compound (C{sub 4}H{sub 12}B{sub 10}O{sub 4}) was synthesized and utilized in the ITEP Bernas ion source resulting in large carborane ion output, without carbon residue. Pure gaseous processes are desired to enable rapid switch among ion species. Molecular phosphorous was generated by introducing phosphine in dissociators via 4PH{sub 3} = P{sub 4} + 6H{sub 2}; generated molecular phosphorous in a pure gaseous process was then injected into the HCEI Calutron-Bernas ion source, from which P{sub 4}{sup +} ion beams were extracted. Results from devices and some additional concepts are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase stability in thermally-aged CASS CF8 under heavy ion irradiation

The stability of the microstructure of a cast austenitic stainless steel (CASS), before and after heavy ion irradiation, was investigated by atom probe tomography (APT). A CF8 ferrite–austenite duplex alloy was thermally aged at 400 °C for 10,000 h. After this treatment, APT revealed nanometer-sized G-phase precipitates and Fe-rich α and Cr-enriched α' phase separated regions in the ferrite. The thermally-aged CF8 specimen was irradiated with 1 MeV Kr ions to a fluence of 1.88 × 10 19 ions/m 2 at 400 °C. After irradiation, APT analysis revealed a strong spatial/dose dependence of the G-phase precipitates and the α–α' spinodal decomposition in the ferrite. For the G-phase precipitates, the number density increased and the mean size decreased with increasing dose, and the particle size distribution changed considerably under irradiation. The inverse coarsening process can be described by recoil resolution. The amplitude of the α–α' spinodal decomposition in the ferrite was apparently reduced after heavy ion irradiation.

Li, Meimei↗

Ion partitioning between brines and ion exchange polymers

Quantitative failure of the ideal Donnan model to predict ion partitioning between relatively dilute electrolyte aqueous solutions and ion exchange polymers arises from neglecting non-ideal behavior of ions. Hypothetically, when a water swollen, charged polymer is equilibrated with concentrated salt solutions, most of the fixed charge groups are neutralized by sorbed counter-ions, which can screen electrostatic effects and create, in the membrane, an environment thermodynamically similar to that experienced by ions in the external electrolyte solution. In this study, a combined experimental and theoretical approach was used to test this hypothesis. A fundamental study of ion partitioning between a cation exchange membrane based on cross-linked poly(p-styrene sulfonate-co-divinylbenzene) and NaCl and CaCl2 concentrated brines is presented. At high electrolyte concentrations, the experimentally measured ion activity coefficients in the membrane match those in the contiguous external solution, and the ideal Donnan model provides an accurate prediction of co-ion and counter-ion concentrations in the polymer. This physical picture was further confirmed by the recently developed Manning-Donnan model.

catalysis (heterogeneous)↗

Hydrodynamic description of an unmagnetized plasma with multiple ion species. II. Two and three ion species plasmas

Paper I [A. N. Simakov and K. Molvig, Phys. Plasmas23, 032115 (2016)] obtained a fluid description for an unmagnetized collisional plasma with multiple ion species. To evaluate collisional plasmatransport fluxes, required for such a description, two linear systems of equations need to be solved to obtain corresponding transport coefficients. In general, this should be done numerically. Herein, the general formalism is used to obtain analytical expressions for such fluxes for several specific cases of interest: a deuterium-tritium plasma; a plasma containing two ion species with strongly disparate masses, which agrees with previously obtained results; and a three ion species plasma made of deuterium, tritium, and gold. We find that these results can be used for understanding the behavior of the aforementioned plasmas, or for verifying a code implementation of the general multi-ion formalism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-induced fluorescence measurements of argon and xenon ion velocities near the sheath boundary in 3 ion species plasmas

The Bohm sheath criterion is studied with laser-induced fluorescence in three ion species plasmas using two tunable diode lasers. Krypton is added to a low pressure unmagnetized DC hot filament discharge in a mixture of argon and xenon gas confined by surface multi-dipole magnetic fields. The argon and xenon ion velocity distribution functions are measured at the sheath-presheath boundary near a negatively biased boundary plate. The potential structures of the plasma sheath and presheath are measured by an emissive probe. Results are compared with previous experiments with Ar–Xe plasmas, where the two ion species were observed to reach the sheath edge at nearly the same speed. This speed was the ion sound speed of the system, which is consistent with the generalized Bohm criterion. In such two ion species plasmas, instability enhanced collisional friction was demonstrated [Hershkowitz et al., Phys. Plasmas 18(5), 057102 (2011).] to exist which accounted for the observed results. When three ion species are present, it is demonstrated under most circumstances the ions do not fall out of the plasma at their individual Bohm velocities. It is also shown that under most circumstances the ions do not fall out of the plasma at the system sound speed. These observations are also consistent with the presence of the instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of Confinement and Zwitterionic Ligand Chemistry on Ion–Ion Selectivity of Functionalized Nanopores

Membranes incorporating zwitterionic chemistries have recently emerged as promising candidates for facilitating challenging ion–ion separations. Transport of ions in such membranes predominantly occurs in hydrated nanopores lined with zwitterionic monomers. Here, to shed light on the physics of ion–ion selectivity underlying such materials, we conducted molecular dynamics simulations of sodium halide transport in model nanopores grafted with sulfobetaine methacrylate molecules. Our results reveal that in both functionalized and unfunctionalized nanopores smaller ions prefer to reside near the pore center, while the larger ions tend to reside near the pore walls. An enhancement in the selective transport of larger anions is observed within the unfunctionalized nanopores relative to that in salt-in-water solutions. Upon functionalization of the nanopores with zwitterions (ZIs), the disparities in the anionic distribution profiles within the pores coupled with differences in the anion-ZI interactions result in a slowdown of larger anions relative to smaller anions. Increasing the ZI grafting density exacerbates these effects, further promoting the selective transport of smaller anions. Our results suggest that selectivity toward large anions can be realized by using nanoporous membranes with ZI content that is high enough to facilitate ion/water partitioning into the pores while preserving the characteristic tendency of the unfunctionalized pores to facilitate faster transport of the larger anions. On the other hand, selectivity toward smaller anions can be achieved by targeting ZI content within the pores that is high enough to significantly slow down the transport of large anions but not high enough to hinder the partitioning of ions/water molecules into the pore due to steric effects.

anions↗

Squeezing of Ion Populations and Peaks in Traveling Wave Ion Mobility Separations and Structures for Lossless Ion Manipulations using Compression Ratio Ion Mobility Programming

In this work, we report an approach for spatial and temporal gas phase ion population manipulation, and demonstrate its application for the collapse of the ion distributions in ion mobility (IM) separations into tighter packets providing higher sensitivity measurements in conjunction with mass spectrometry (MS). We do this for ions moving from a conventionally traveling wave (TW)-driven region to a region where the TW is intermittently halted or ‘stuttered’. This approach causes the ion packets spanning a number of TW-created traveling traps (TT) to be redistributed into fewer TT, resulting in spatial compression. The degree of spatial compression is controllable and determined by the ratio of stationary time of the TW in the second region to its moving time. This compression ratio ion mobility programming (CRIMP) approach has been implemented using Structures for Lossless Ion Manipulations (SLIM) in conjunction with MS. CRIMP with the SLIM-MS platform is shown to provide increased peak intensities, reduced peak widths, and improved S/N ratios with MS detection. CRIMP also provides a foundation for extremely long path length and multi-pass IM separations in SLIM providing greatly enhanced IM resolution by reducing the detrimental effects of diffusional peak broadening due to increasing peak widths.

Environmental Molecular Sciences Laboratory↗