Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

Development and implementation of a portable grating interferometer system as a standard tool for testing optics at the Advanced Photon Source beamline 1-BM

We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APS beamlines for beam coherence and wavefront characterization or imaging. Herein, the design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.

47 OTHER INSTRUMENTATION↗

39 GHz Interferometer System for Measuring Detonation Velocity

A new 39 GHz RF interferometer system is presented for use in velocity measurements of high explosives (HE) detonations. The frequency was chosen to compliment the currently available suite, and provide more spatial information. An RF signal is generated and coupled to a waveguide adapter serving as an antenna. The HE is initially transparent to the RF. When the HE detonates, the detonation front becomes reflective to the RF. This reflection is picked up by the waveguide adapter and mixed with an unperturbed RF signal to give a low frequency signal which can be digitized with an oscilloscope. By comparing the signal with a reference signal, velocity information can be obtained using Fourier Transforms and wavelet models. Bench test results using a “slapper” are shown. The 39 GHz microwave interferometer is used in Deflagration to Detonation shots. The signal is reflected off a moving surface, and the Doppler shift of the reflected signal is used to calculate the velocity.

Ross, Patrick W.↗

Effects of stray lights on Faraday rotation measurement for polarimeter-interferometer system on EAST

A double-pass radially view 11 chords polarimeter-interferometer system has been operated on the experimental advanced superconducting tokamak and provides important current profile information for plasma control. Stray light originating from spurious reflections along the optical path (unwanted reflections from various optical components/mounts and transmissive optical elements such as windows, waveplates, and lens as well as the detectors) and also direct feedback from the retro-reflector used to realize the double-pass configuration can both contribute to contamination of the Faraday rotation measurement accuracy. Modulation of the Faraday rotation signal due to the interference from multiple reflections is observable when the interferometer phase (plasma density) varies with time. Direct reflection from the detector itself can be suppressed by employing an optical isolator consisting of a λ/4-waveplate and polarizer positioned in front of the mixer. A Faraday angle oscillation during the density ramping up (or down) can be reduced from 5°–10° to 1°–2° by eliminating reflections from the detector. Residual modulation arising from misalignment and stray light from other sources must be minimized to achieve accurate measurements of Faraday rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear interferometer systems and methods

Nonlinear interferometers include a nonlinear optical medium that is situated to produce a conjugate optical beam in response to a pump beam and a probe beam. The pump, probe, and conjugate beams propagate displaced from each other along a common optical path. One of the beams is selectively phase shifted, and the beams are then returned to the nonlinear medium, with the selectively phase shift beam phase shifted again. The nonlinear medium provides phase sensitive gain to at least one of the probe or conjugate beams, and the amplified beam is detected to provide an estimate of the phase shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring preheat in laser-drive aluminum using velocity interferometer system for any reflector: Experiment

In this paper, we systematically study preheating in laser-direct-drive shocks by using a velocity interferometer system for any reflector (VISAR). Using the VISAR, we measured free surface velocity histories of Al samples over time, 10–70 μm thick, driven directly by a laser at different frequencies (2ω, 3ω). Analyzing our experimental results, we concluded that the dominant preheating source was X-ray radiation. We also discussed how preheating affected the material initial density and the measurement of Hugoniot data for high-Z materials (such as Au) using impedance matching. To reduce preheating, we proposed and tested three kinds of targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution polarimeter-interferometer system for fast equilibrium dynamics and MHD instability studies on Joint-TEXT tokamak (invited)

A high-performance Faraday-effect polarimeter-interferometer system has been developed for the J-TEXT tokamak. This system has time response up to 1 μs, phase resolution < 0.1° and minimum spatial resolution ∼15 mm. High resolution permits investigation of fast equilibrium dynamics as well as magnetic and density perturbations associated with intrinsic Magneto-Hydro-Dynamic (MHD) instabilities and external coil-induced Resonant Magnetic Perturbations (RMP). The 3-wave technique, in which the line-integrated Faraday angle and electron density are measured simultaneously by three laser beams with specific polarizations and frequency offsets, is used. In order to achieve optimum resolution, three frequency-stabilized HCOOH lasers (694 GHz, >35 mW per cavity) and sensitive Planar Schottky Diode mixers are used, providing stable intermediate-frequency signals (0.5–3 MHz) with S/N > 50. The collinear R- and L-wave probe beams, which propagate through the plasma poloidal cross section (a = 0.25–0.27 m) vertically, are expanded using parabolic mirrors to cover the entire plasma column. Sources of systematic errors, e.g., stemming from mechanical vibration, beam non-collinearity, and beam polarization distortion are individually examined and minimized to ensure measurement accuracy. Simultaneous density and Faraday measurements have been successfully achieved for 14 chords. Based on measurements, temporal evolution of safety factor profile, current density profile, and electron density profile are resolved. Core magnetic and density perturbations associated with MHD tearing instabilities are clearly detected. Effects of non-axisymmetric 3D RMP in ohmically heated plasmas are directly observed by polarimetry for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging velocity interferometer system for any reflector (VISAR) diagnostics for high energy density sciences

Two variants of optical imaging velocimetry, specifically the one-dimensional streaked line-imaging and the two-dimensional time-resolved area-imaging versions of the Velocity Interferometer System for Any Reflector (VISAR), have become important diagnostics in high energy density sciences, including inertial confinement fusion and dynamic compression of condensed matter. Here, we give a brief review of the historical development of these techniques, then describe the current implementations at major high energy density (HED) facilities worldwide, including the OMEGA Laser Facility and the National Ignition Facility. We illustrate the versatility and power of these techniques by reviewing diverse applications of imaging VISARs for gas-gun and laser-driven dynamic compression experiments for materials science, shock physics, condensed matter physics, chemical physics, plasma physics, planetary science and astronomy, as well as a broad range of HED experiments and laser-driven inertial confinement fusion research.

47 OTHER INSTRUMENTATION↗

Design of interferometer system for Keda Torus eXperiment using terahertz solid-state diode sources

A solid-state source based terahertz (THz) interferometer diagnostic system has been designed and characterized for the Keda Torus eXperiment (KTX). The THz interferometer utilizes the planar diodes based frequency multiplier (X48) to provide the probing beam at fixed frequency 0.650 THz, and local oscillator is provided by an independent solid-state diode source with tunable frequency (0.650 THz +/− 10 MHz). Both solid-state sources have approximately 1 mW power. The planar-diode mixers optimized for high sensitivity, ∼750 mV/mW, are used in the heterodyne detection system, which permits multichannel interferometer on KTX with a low phase noise. A sensitivity of {sub min} = 4.5 × 10{sup 16} m{sup −2} and a temporal resolution of 0.2 μs have been achieved during the initial bench test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical layout and mechanical structure of polarimeter-interferometer system for Experimental Advanced Superconducting Tokamak

A Far-InfaRed (FIR) three-wave POlarimeter-INTerferometer (POINT) system for measurement current density profile and electron density profile is under development for the EAST tokamak. The FIR beams are transmitted from the laser room to the optical tower adjacent to EAST via ∼20 m overmoded dielectric waveguide and then divided into 5 horizontal chords. The optical arrangement was designed using ZEMAX, which provides information on the beam spot size and energy distribution throughout the optical system. ZEMAX calculations used to optimize the optical layout design are combined with the mechanical design from CATIA, providing a 3D visualization of the entire POINT system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Faraday-effect polarimeter-interferometer system for current density measurement on EAST

A multichannel far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique is under development for current density and electron density profile measurements in the EAST tokamak. Novel molybdenum retro-reflectors are mounted in the inside wall for the double-pass optical arrangement. A Digital Phase Detector with 250 kHz bandwidth, which will provide real-time Faraday rotation angle and density phase shift output, have been developed for use on the POINT system. Initial calibration indicates the electron line-integrated density resolution is less than 5 × 10{sup 16} m{sup −2} (∼2°), and the Faraday rotation angle rms phase noise is <0.1°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A phase contrast imaging–interferometer system for detection of multiscale electron density fluctuations on DIII-D

Heterodyne interferometry and phase contrast imaging (PCI) are robust, mature techniques for measuring low-k and high-k electron density fluctuations, respectively. This work describes the first-ever implementation of a combined PCI–interferometer. The combined system uses a single 10.6 μm probe beam, two interference schemes, and two detectors to measure electron density fluctuations at large spatiotemporal bandwidth (10 kHz <f < 5 MHz and 0 cm{sup -1} ≤k ≤ 20 cm{sup -1}), allowing simultaneous measurement of ion- and electron-scale instabilities. Further, correlating our interferometer’s measurements with those from DIII-D’s pre-existing, toroidally separated interferometer allows core-localized, low-n MHD studies that may otherwise be inaccessible via external magnetic measurements. The combined diagnostic’s small port requirements and minimal access restrictions make it well-suited to the harsh neutron environments and limited port space expected in next-step devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A combined phase contrast imaging and heterodyne interferometer system for multiscale fluctuation measurements (invited)

In this work, a novel combined diagnostic capable of measuring multiscale density fluctuations that extend from magnetohydrodynamic (MHD) to the lower range of electron temperature gradient turbulence has been designed, installed, and operated at DIII-D. The combined diagnostic was constructed by adding a heterodyne interferometer to the pre-existing phase contrast imaging (PCI) system, both of which measure line-integrated electron density fluctuations. The port-space footprint is minimized via use of a single 10.6 μm probe beam. With temporal bandwidths in excess of 1 MHz, the PCI measures high-k (1.5 cm -1 < |k R | ≤ 25 cm -1 ) fluctuations with sensitivity 3×10 13 m -2 /$\sqrt{kHz}$, while the interferometer simultaneously measures low-k (|k R | < 5 cm -1 ) fluctuations with sensitivity 3×10 14 m -2 /$\sqrt{kHz}$. The intentional mid-k overlap has been empirically verified with sound-wave calibrations and allows quantitative investigation of multiscale effects that are predicted to be significant in the reactor-relevant T e ~ T i regime. Lastly, via correlation with the primary DIII-D interferometer, the toroidal mode numbers of core-localized MHD can be measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensor system that uses embedded optical fibers

Sensor systems including an interferometer system are disclosed herein. In a general embodiment, the sensor system includes an optical fiber that is embedded into a sample, where the optical fiber has a reflective tip. The optical fiber is optically coupled to a sensor and a detector of the laser interferometer system. The sensor system further includes a computing device or circuit that is configured to receive electrical signals generated by the detector. The laser source is configured to emit light, which is coupled into the optical fiber. The light travels through the optical fiber until the light reaches the reflective tip, where it is reflected back through the optical fiber. The detector is impacted by the reflected light, and generates an electrical signal based upon the reflected light. The computing device generates a value that is indicative of a behavior of the sample based upon the electrical signal.

Chavez, Marcus Alexander↗

An upgraded interferometer-polarimeter system for broadband fluctuation measurements

Measuring high-frequency fluctuations (above tearing mode frequencies) is important for diagnosing instabilities and transport phenomena. The Madison Symmetric Torus interferometer-polarimeter system has been upgraded to utilize improved planar-diode mixer technology. The new mixers reduce phase noise and allow more sensitive measurements of fluctuations at high frequency. Typical polarimeter rms phase noise values of 0.05°–0.07° are obtained with 400 kHz bandwidth. The low phase noise enables the resolution of fluctuations up to 250 kHz for polarimetry and 600 kHz for interferometry. The importance of probe beam alignment for polarimetry is also verified; previously reported tolerances of ≤0.1 mm displacement for equilibrium and tearing mode measurements minimize contamination due to spatial misalignment to within acceptable levels for chords near the magnetic axis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗