Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Integral dose investigation of non-coplanar treatment beam geometries in radiotherapy

Purpose: Automated planning and delivery of non-coplanar plans such as 4π radiotherapy involving a large number of fields have been developed to take advantage of the newly available automated couch and gantry on C-arm gantry linacs. However, there is an increasing concern regarding the potential changes in the integral dose that needs to be investigated. Methods: A digital torso phantom and 22 lung and liver stereotactic body radiation therapy (SBRT) patients were included in the study. The digital phantom was constructed as a water equivalent elliptical cylinder with a major axis length of 35.4 cm and minor axis of 23.6 cm. A 4.5 cm diameter target was positioned at varying depths along the major axis. Integral doses from intensity modulated, non-coplanar beams forming a conical pattern were compared against the equally spaced coplanar beam plans. Integral dose dependence on the phantom geometry and the beam number was also quantified. For the patient plans, the non-coplanar and coplanar beams and fluences were optimized using a column generation and pricing approach and compared against clinical VMAT plans using two full (lung) or partial coplanar arcs (liver) entering at the side proximal to the tumor. Both the average dose to the normal tissue volume and the total volumes receiving greater than 2 Gy (V2) and 5 Gy (V5) were evaluated and compared. Results: The ratio of integral dose from the non-coplanar and coplanar plans depended on the tumor depth for the phantom; for tumors shallower than 10 cm, the non-coplanar integral doses were lower than coplanar integral doses for non-coplanar angles less than 60°. Similar patterns were observed in the patient plans. The smallest non-coplanar integral doses were observed for tumor 6–8 cm deep. For the phantom, the integral dose was independent of the number of beams, consistent with the liver SBRT patients but the lung SBRT patients showed slight increase in the integral dose when more beams were used. Larger tumor size and larger patient body size did not change the overall relationship of integral doses between non-coplanar and coplanar cases. However, the thin disk-shaped tumor received at least 40% greater integral doses with the non-coplanar plans. Overall, patient non-coplanar integral doses and V5 were comparable to those of coplanar doses from the same optimization engine and 15%–20% lower than state of the art VMAT plans. However, non-coplanar beams significantly increased V2 in both the phantom and patients. On average, the lung and liver SBRT patient normal tissue volumes receiving dose greater than 2 Gy were increased by 749 and 532 cm{sup 3}, respectively. Conclusions: The authors used a digital phantom simulating a patient torso and 22 SBRT patients to show that the integral doses from the plans employing optimized non-coplanar beams are comparable to those of the coplanar plans using an equal number of discrete beams and are significantly lower than those of VMAT plans. The non-coplanar beams expose a larger normal tissue volume to non-zero doses, whose impact will need to be evaluated individually to determine the risk/benefit ratio of the non-coplanar plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integral dose during constant velocity motion near a space power reactor

The dose rate in a rotationally-symmetric radiation field near a space power reactor is assumed to be inversely proportional to separation distance squared and directly proportional either to a constant or a constant times the sine-cubed of a polar angle. Constant velocity motion is examined in both cases in both two and three dimensional geometries. The two dimensional geometry occurs when the line of motion and the field axis of symmetry are co-planar. The dose integral in the sine-cubed region may be integrated directly, but a more useful form is obtained after a change of variable. A coordinate system rotation greatly simplifies the results. The three dimensional problem is integrated after a change of variable. Finally, tables of normalized functions are presented and discussed.

Manning, H. S.↗

Analysis of Electronic Densities and Integrated Doses in Multiform Glioblastomas Stereotactic Radiotherapy

Integrated dose is the total energy delivered in a radiotherapy target. This physical parameter could be a predictor for complications such as brain edema and radionecrosis after stereotactic radiotherapy treatments for brain tumors. Integrated Dose depends on the tissue density and volume. Using CT patients images from the National Institute of Neurology and Neurosurgery and BrainScan(c) software, this work presents the mean density of 21 multiform glioblastomas, comparative results for normal tissue and estimated integrated dose for each case. The relationship between integrated dose and the probability of complications is discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of a Second Malignant Neoplasm After Cancer in Childhood Treated With Radiotherapy: Correlation With the Integral Dose Restricted to the Irradiated Fields

Purpose: After successful treatment of cancers in childhood, the occurrence of second malignant neoplasm (SMN) came to the fore. Few studies have considered the relationship between the radiation dose received and the risk of developing an SMN. To take into account the heterogeneity of the dose distribution so as to evaluate the overall risk of an SMN after a childhood cancer, we therefore focused on the integral dose restricted to the irradiated fields. Methods and Materials: The study was performed in a cohort of 4,401 patients who were 3-year survivors of all types of childhood cancer treated between 1947 and 1986 in France and Great Britain. For each patient, the integral dose was estimated for the volume inside the beam edges. Results: We found a significant dose-response relationship between the overall risk of an SMN and the estimated integral dose. The excess relative risk for each incremental unit of the integral dose was only 0.008 in a linear model and 0.017 when a negative exponential term was considered, when adjusted for chemotherapy. The risk of SMN occurrence was 2.6 times higher in the case of irradiation. However among patients who had received radiotherapy, only those who had received the highest integral dose actually had a higher risk. Conclusions: The integral dose in our study cannot be considered as a good predictor of later risks. However other studies with the same study design are obviously needed to evaluate the use of the integral dose as a tool for decision making concerning different radiotherapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-166: Evaluation of Integral Dose in Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy for Head and Neck Cancer Patient

Purpose: Volumetric Modulated Arc Therapy (VMAT) usually achieves higher conformity of radiation doses to targets and less delivery time than Intensity Modulated Radiation Therapy (IMRT). We hypothesized that VMAT will increase integral dose (ID) to patients which will decrease the count of white blood count (WBC) lymphocytes, and consequently has a subsequent impact on the immune system. The purpose of this study is to evaluate the ID to patients undergoing IMRT and VMAT for Head and Neck cancers and its impact on the immune system. Methods: As a pilot study, 30 head and neck patients who received 9-fields IMRT or 3-arcs Radip-Arcbased VMAT were included in this study. Ten of these patients who received the VMAT plans were re-planned using IMRT with the same objectives. ID was calculated for all cases. All patients also had a baseline WBC obtained prior to treatment, and 3 sets of labs drawn during the course of radiation treatment. Results: For the 10 re-planned patients, the mean ID was 13.3 Gy/voxel (range 10.2–17.5 Gy/voxel) for the 9-fields IMRT plans, and was 15.9 Gy/voxel (range 12.4-20.9 Gy/voxel) for the 3-Arc VMAT plan (p=0.01). The integral dose was significant correlated with reducing WBC count during RT even when controlling for concurrent chemotherapy (R square =0.56, p=0.008). Conclusion: Although VMAT can deliver higher radiation dose conformality to targets, this benefit is achieved generally at the cost of greater integral doses to normal tissue outside the planning target volume (PTV). Lower WBC counts during RT were associated with higher Integral doses even when controlling for concurrent chemotherapy. This study is ongoing in our Institution to exam the impact of integral doses and WBC on overall survival.

60 APPLIED LIFE SCIENCES↗

Integral dose conservation in radiotherapy

Treatment planners frequently modify beam arrangements and use IMRT to improve target dose coverage while satisfying dose constraints on normal tissues. The authors herein analyze the limitations of these strategies and quantitatively assess the extent to which dose can be redistributed within the patient volume. Specifically, the authors hypothesize that (1) the normalized integral dose is constant across concentric shells of normal tissue surrounding the target (normalized to the average integral shell dose), (2) the normalized integral shell dose is constant across plans with different numbers and orientations of beams, and (3) the normalized integral shell dose is constant across plans when reducing the dose to a critical structure. Using the images of seven patients previously irradiated for cancer of brain or prostate cancer and one idealized scenario, competing three-dimensional conformal and IMRT plans were generated using different beam configurations. Within a given plan and for competing plans with a constant mean target dose, the normalized integral doses within concentric ''shells'' of surrounding normal tissue were quantitatively compared. Within each patient, the normalized integral dose to shells of normal tissue surrounding the target was relatively constant (1). Similarly, for each clinical scenario, the normalized integral dose for a given shell was also relatively constant regardless of the number and orientation of beams (2) or degree of sparing of a critical structure (3). 3D and IMRT planning tools can redistribute, rather than eliminate dose to the surrounding normal tissues (intuitively known by planners). More specifically, dose cannot be moved between shells surrounding the target but only within a shell. This implies that there are limitations in the extent to which a critical structure can be spared based on the location and geometry of the critical structure relative to the target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effects of Gamma Ray Integrated Dose on a Commercial 65-nm SRAM Device

Here this work shows that the static random access memory (SRAM) error rate for a commercial 65-nm device in a dose rate environment can be highly dependent upon the integrated dose (dose rate × pulse duration). While the typical metric for such testing is dose rate upset (DRU) level in rad(Si)/s, a series of dose rate experiments at Little Mountain Test Facility (LMTF) shows dependence on the integrated dose. The error rate is also found to be dependent on the core voltage, and the preradiation value of the bits. We believe that these effects are explained by a well charge depletion caused by gamma ray photocurrent.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of IMRT Treatment Plans Between Linac and Helical Tomotherapy Based on Integral Dose and Inhomogeneity Index

Intensity modulated radiotherapy (IMRT) is an advanced treatment technology for radiation therapy. There are several treatment planning systems (TPS) that can generate IMRT plans. These plans may show different inhomogeneity indices to the planning target volume (PTV) and integral dose to organs at risk (OAR). In this study, we compared clinical cases covering different anatomical treatment sites, including head and neck, brain, lung, prostate, pelvis, and cranio-spinal axis. Two treatment plans were developed for each case using Pinnacle{sup 3} and helical tomotherapy (HT) TPS. The inhomogeneity index of the PTV and the non-tumor integral dose (NTID) were calculated and compared for each case. Despite the difference in the number of effective beams, in several cases, NTID did not increase from HT as compared to the step-and-shoot delivery method. Six helical tomotherapy treatment plans for different treatment sites have been analyzed and compared against corresponding step-and-shoot plans generated with the Pinnacle{sup 3} planning system. Results show that HT may produce plans with smaller integral doses to healthy organs, and fairly homogeneous doses to the target as compared to linac-based step-and-shoot IMRT planning in special treatment site such as cranio-spinal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MOSFET sensitivity dependence on integrated dose from high-energy photon beams

The ability of a commercially available dual bias, dual MOSFET dosimetry system to measure therapeutic doses reproducibly throughout its vendor-defined dose-based lifetime has been evaluated by characterizing its sensitivity variation to integrated/cumulative doses from high-energy (6 and 15 MV) photon radiotherapy beams. The variation of sensitivity as a function of total integrated dose was studied for three different dose-per-fraction levels; namely, 50, 200, and 1200 cGy/fraction. In standard sensitivity mode (i.e., measurements involving dose-per-fraction levels {>=}100 cGy), the response of the MOSFET system to identical irradiations increased with integrated dose for both energies investigated. Dose measurement reproducibility for the low (i.e., 50 cGy) dose fractions was within 2.1% (if the system was calibrated before each in-phantom measurement) and 3.1% [if the system was calibrated prior to first use, with no intermediate calibration(s)]. Similarly, dose measurement reproducibility was between 2.2% and 6.6% for the conventional (i.e., 200 cGy) dose fractions and between 1.8% and 7.9% for escalated (i.e., 1200 cGy) dose fractions. The results of this study suggest that, due to the progressively increasing sensitivity resulting from the dual-MOSFET design, frequent calibrations are required to achieve measurement accuracy of {<=}3% (within one standard deviation)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total integrated dose testing of solid-state scientific CD4011, CD4013, and CD4060 devices by irradiation with CO-60 gamma rays

The total integrated dose response of three CMOS devices manufactured by Solid State Scientific has been measured using CO-60 gamma rays. Key parameter measurements were made and compared for each device type. The data show that the CD4011, CD4013, and CD4060 produced by this manufacturers should not be used in any environments where radiation levels might exceed 1,000 rad(Si).

Dantas, A. R. V.↗

Total Integrated Dose to Spent Fuel Pool Level Instrument Probes and Refueling Floor Personnel Dose Rates Meeting NRC Order EA-12-051 for a Typical Boiling Water Reactor - Paper 22

In reviewing the events after the March 11, 2011 Fukushima accident, the Nuclear Regulatory Commission (NRC) issued Order EA-12-051, Reference 1, requiring new reliable spent fuel pool (SFP) instrumentation for pool level determination under beyond design basis event conditions. In 2013, URS prepared a calculation for a typical Boiling Water Reactor to determine the Total Integrated Dose (TID) potentially to be imparted to radiation sensitive underwater probes (one primary and one backup) planned for meeting this Order. Additionally, URS calculated the radiological dose rates to an individual standing on the refueling floor for various SFP fill levels. NEI 12-02, Reference 2, defines the levels at which SFP condition identification is necessary as the following: Level 1 - level that is adequate to support operation of the normal fuel pool cooling system. Level 1 represents the higher of the following two points: - The level at which reliable suction loss occurs due to uncovering of the coolant inlet pipe, weir or vacuum breaker (depending on the design), or - The level at which the water height, assuming saturated conditions, above the centerline of the cooling pump suction provides the required net positive suction head specified by the pump manufacturer or engineering analysis. Level 2 - level that is adequate to provide substantial radiation shielding for a person standing on the spent fuel pool operating deck. Level 2 is based on either of the following: - 10 feet (+/- 1 foot) above the highest point of any fuel rack seated in the spent fuel pools, or - A designated level that provides adequate radiation shielding to maintain personnel radiological dose levels within acceptable limits while performing local operations in the vicinity of the pool. This level shall be based on either plant-specific or appropriate generic shielding calculations, considering the emergency conditions that may apply at the time and the scope of necessary local operations, including installation of portable SFP instrument channel components. Level 3 - level where fuel remains covered and actions to implement make-up water addition should no longer be deferred. Level 3 corresponds nominally (i.e. +/- 1 foot) to the highest point of any fuel rack seated in the spent fuel pool. The URS calculation did not define these levels or determine instrumentation setpoints. However, it determined refueling floor dose rates that could be used as a tool to determine the appropriate water depths for these levels. In determining the TID for the SFP probes and the radiological dose rates to the individual, the following radioactive sources were considered: 1. Spent Nuclear Fuel (SNF) stored in the spent fuel storage racks, 2. Local Power Range Monitors (LPRMs) stored above the top of the racks on hangers on the SFP walls 3. Radioactive material laden filters stored on platforms on top of the racks, and 4. Control Rod Blades (CRBs) stored above the top of the racks on hangers on the SFP walls. The TID for the SFP probes includes both the dose from normal operation (pool full of water) for the remaining plant life (an assumed 40 years, conservatively including an allowance for lifetime extension SFP loading) and, consistent with the NEI 12-02 guidelines, Reference 2, the assumed drop in elevation of the pool water level to the top of the spent fuel racks for a 6 hour period. The acceptable TID for the radiation-sensitive probe as defined by the manufacturer was 2x10{sup 9} rad. The individual on the pool deck was assumed to be standing on the edge of the pool with an unobstructed view of its contents, as a worst case scenario. Dose rates to this individual determined from direct shine from the same 4 sources were determined for SFP water levels varying from 1 ft above the SNF racks to 21 ft above the racks in one foot increments. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Megavoltage Cone Beam Computed Tomography Dose and the Necessity of Reoptimization for Imaging Dose-Integrated Intensity-Modulated Radiotherapy for Prostate Cancer

Purpose: Megavoltage cone beam computed tomography (MV-CBCT) dose can be integrated with the patient's prescription. Here, we investigated the effects of imaging dose and the necessity for additional optimization when using intensity-modulated radiotherapy (IMRT) to treat prostate cancer. Methods and Materials: An arc beam mimicking MV-CBCT was generated using XiO (version 4.50; Elekta, Stockholm, Sweden). The monitor units (MU) for dose calculation were determined by conforming the calculated dose to the dose measured using an ionization chamber. IMRT treatment plans of 22 patients with prostate cancer were retrospectively analyzed. Arc beams of 3, 5, 8, and 15 MU were added to the IMRT plans, and the dose covering 95% of the planning target volume (PTV) was normalized to the prescribed dose with (reoptimization) or without optimization (compensation). Results: PTV homogeneity and conformality changed negligibly with MV-CBCT integration. For critical organs, an imaging dose-dependent increase was observed for the mean rectal/bladder dose (D{sub mean}), and reoptimization effectively suppressed the D{sub mean} elevations. The bladder generalized equivalent uniform dose (gEUD) increased with imaging dose, and reoptimization suppressed the gEUD elevation when 5- to 15-MU CBCT were added, although rectal gEUD changed negligibly with any imaging dose. Whereas the dose elevation from the simple addition of the imaging dose uniformly increased rectal and bladder dose, the rectal D{sub mean} increase of compensation plans was due mainly to low-dose volumes. In contrast, bladder high-dose volumes were increased by integrating the CBCT dose, and reoptimization reduced them when 5- to 15-MU CBCT were added. Conclusion: Reoptimization is clearly beneficial for reducing dose to critical organs, elevated by addition of high-MU CBCT, especially for the bladder. For low-MU CBCT aimed at bony structure visualization, compensation is sufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-19A-04: Commissioning and Validation of EBT3 Gafchromic Films for Measurements of Dose Profiles and Integrals of Dose in Small Fields

Purpose: The use of a primary dosimeter larger than the radiation field gives access to the integral of dose over a specified surface normal to the beam. If a relative dose profile of the beam is well known, it is then possible to calculate the distribution of the absorbed dose at any point on the considered surface. This study aims at validating the use of EBT3 gafchromic films for the measurement of 2D dose distribution and integrals of dose in small fields for such use. Methods: New EBT3 films have been fully characterized: the response versus energy, dose-rate and dose has been investigated. Profiles measured in circular field with a diameter of 20 mm have been compared to the ones measured with a diamond detector developed at CEA/LIST/LCD. The ratio of dose area products measured with EBT3 on a 6 mm and 30 mm diameter surface has been compared to the ratio measured with primary dosimeters (calorimeters) and calculated with Monte Carlo simulations. Results: There was no significant difference between the dose-calibration curves in a 6 MV and a 60Co beam. Deviation was within uncertainty bars when the dose rate inside a pulse was divided by a factor of 80 in the 6 MV photon beam. Profiles in small fields are in good agreement with the diamond profiles. Dose area product ratios obtained with EBT3, calorimeters and simulations are within 1%. Conclusion: EBT3 films are good candidates for the measurement of relative dose distribution in small fields as long as the average of several films is considered. They can be used in association with primary measurements to determinate dosimetric references in small fields and to transfer them to the end user.

60 APPLIED LIFE SCIENCES↗

A novel methodology for 3D deformable dosimetry

Purpose: Interfraction and intrafraction variation in anatomic structures is a significant challenge in contemporary radiotherapy. The objective of this work is to develop a novel tool for deformable structure dosimetry, using a tissue-equivalent deformable gel dosimeter that can reproducibly simulate targets subject to deformation. This will enable direct measurement of integrated doses delivered in different deformation states, and the verification of dose deforming algorithms. Methods: A modified version of the nPAG polymer gel has been used as a deformable 3D dosimeter and phantom to investigate doses delivered to deforming tissue-equivalent geometry. The deformable gel (DEFGEL) dosimeter/phantom is comprised of polymer gel in a latex membrane, moulded (in this case) into a cylindrical geometry, and deformed with an acrylic compressor. Fifteen aluminium fiducial markers (FM) were implanted into DEFGEL phantoms and the reproducibility of deformation was determined via multiple computed tomography (CT) scans in deformed and nondeformed states before and after multiple (up to 150) deformations. Dose was delivered to the DEFGEL phantom in three arrangements: (i) without deformation, (ii) with deformation, and (iii) cumulative exposures with and without deformation, i.e., dose integration. Irradiations included both square field and a stereotactic multiple dynamic arc treatment adapted from a patient plan. Doses delivered to the DEFGEL phantom were read out using cone beam optical CT. Results: Reproducibility was verified by observation of interscan shifts of FM locations (as determined via CT), measured from an absolute reference point and in terms of inter-FM distance. The majority (76%) of points exhibited zero shift, with others shifting by one pixel size consistent with setup error as confirmed with a control sample. Comparison of dose profiles and 2D isodose distributions from the three arrangements illustrated complex spatial redistribution of dose in all three dimensions occurring as a result of the change in shape of the target between irradiations, even for a relatively simple deformation. Discrepancies of up to 30% of the maximum dose were evident from dose difference maps for three orthogonal planes taken through the isocenter of a stereotactic field. Conclusions: This paper describes the first use of a tissue-equivalent, 3D dose-integrating deformable phantom that yields integrated or redistributed dosimetric information. The proposed methodology readily yields three-dimensional (3D) dosimetric data from radiation delivery to the DEFGEL phantom in deformed and undeformed states. The impacts of deformation on dose distributions were readily seen in the isodose contours and line profiles from the three arrangements. It is demonstrated that the system is potentially capable of reproducibly emulating the physical deformation of an organ, and therefore can be used to evaluate absorbed doses to deformable targets and organs at risk in three dimensions and to validate deformation algorithms applied to dose distributions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Generalizable Class Solutions for Treatment Planning of Spinal Stereotactic Body Radiation Therapy

Purpose: Spinal stereotactic body radiation therapy (SBRT) continues to emerge as an effective therapeutic approach to spinal metastases; however, treatment planning and delivery remain resource intensive at many centers, which may hamper efficient implementation in clinical practice. We sought to develop a generalizable class solution approach for spinal SBRT treatment planning that would allow confidence that a given plan provides optimal target coverage, reduce integral dose, and maximize planning efficiency. Methods and Materials: We examined 91 patients treated with spinal SBRT at our institution. Treatment plans were categorized by lesion location, clinical target volume (CTV) configuration, and dose fractionation scheme, and then analyzed to determine the technically achievable dose gradient. A radial cord expansion was subtracted from the CTV to yield a planning CTV (pCTV) construct for plan evaluation. We reviewed the treatment plans with respect to target coverage, dose gradient, integral dose, conformality, and maximum cord dose to select the best plans and develop a set of class solutions. Results: The class solution technique generated plans that maintained target coverage and improved conformality (1.2-fold increase in the 95% van't Riet Conformation Number describing the conformality of a reference dose to the target) while reducing normal tissue integral dose (1.3-fold decrease in the volume receiving 4 Gy (V{sub 4Gy}) and machine output (19% monitor unit (MU) reduction). In trials of planning efficiency, the class solution technique reduced treatment planning time by 30% to 60% and MUs required by {approx}20%: an effect independent of prior planning experience. Conclusions: We have developed a set of class solutions for spinal SBRT that incorporate a pCTV metric for plan evaluation while yielding dosimetrically superior treatment plans with increased planning efficiency. Our technique thus allows for efficient, reproducible, and high-quality spinal SBRT treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A hybrid electron and photon IMRT planning technique that lowers normal tissue integral patient dose using standard hardware

Purpose: To present a mixed electron and photon IMRT planning technique using electron beams with an energy range of 6-22 MeV and standard hardware that minimizes integral dose to patients for targets as deep as 7.5 cm. Methods: Ten brain cases, two lung, a thyroid, an abdominal, and a parotid case were planned using two planning techniques: a photon-only IMRT (IMRT) versus a mixed modality treatment (E + IMRT) that includes an enface electron beam and a photon IMRT portion that ensures a uniform target coverage. The electron beam is delivered using a regular cutout placed in an electron cone. The electron energy was chosen to provide a good trade-off between minimizing integral dose and generating a uniform, deliverable plan. The authors choose electron energies that cover the deepest part of PTV with the 65%-70% isodose line. The normal tissue integral dose, the dose for ring structures around the PTV, and the volumes of the 75%, 50%, and 25% isosurfaces were used to compare the dose distributions generated by the two planning techniques. Results: The normal tissue integral dose was lowered by about 20% by the E + IMRT plans compared to the photon-only IMRT ones for most studied cases. With the exception of lungs, the dose reduction associated to the E + IMRT plans was more pronounced further away from the target. The average dose ratio delivered to the 0-2 cm and the 2-4 cm ring structures for brain patients for the two planning techniques were 89.6% and 70.8%, respectively. The enhanced dose sparing away from the target for the brain patients can also be observed in the ratio of the 75%, 50%, and 25% isodose line volumes for the two techniques, which decreases from 85.5% to 72.6% and further to 65.1%, respectively. For lungs, the lateral electron beams used in the E + IMRT plans were perpendicular to the mostly anterior/posterior photon beams, generating much more conformal plans. Conclusions: The authors proved that even using the existing electron delivery hardware, a mixed electron/photon planning technique (E + IMRT) can decrease the normal tissue integral dose compared to a photon-only IMRT plan. Different planning approaches can be enabled by the use of an electron beam directed toward organs at risk distal to the target, which are still spared due the rapid dose fall-off of the electron beam. Examples of such cases are the lateral electron beams in the thoracic region that do not irradiate the heart and contralateral lung, electron beams pointed toward kidneys in the abdominal region, or beams treating brain lesions pointed toward the brainstem or optical apparatus. For brain, electron vertex beams can also be used without irradiating the whole body. Since radiation retreatments become more and more common, minimizing the normal tissue integral dose and the dose delivered to tissues surrounding the target, as enabled by E + IMRT type techniques, should receive more attention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗