Engineering PapersSearch

SEARCH · Engineering Papers

Results for “INSTRUMENT & FEATURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A survey of mass analyzers

With the increasing applications of mass spectrometry technology to diverse services areas, a need has developed for a consolidated survey of the essential characteristics and features of the various instruments and techniques. This report is one approach to satisfying this need. Information has been collected and consolidated into a format which includes for each approach: (1) a general technique description, (2) instrument features information, and (3) a summary of pertinent advantages and disadvantages. With this information, the potential mass spectrometer user should be able to more efficiently select the most appropriate instrument.

Moore, W. W., Jr.

SONGS - A high resolution imaging gamma-ray spectrometer for the Space Station

The overall design and the instrumental features of the Space-Station Observer for Nuclear Gamma-ray Spectroscopy (SONGS) instrument are described. SONGS comprises an array of 19 two-segment n-type Ge detectors, which have the capability of determining the interaction site in either the upper or the lower segment or in both segments. The detectors provide high energy resolution of 1 keV at 100 keV and of 2 keV at 1 MeV. The close-packed Ge sensor array provides a natural sensitivity for the measurement of gamma ray polarization in the 100 keV to 1 MeV energy range, making it possible to obtain information on the structure of the magnetosphere of neutron stars and of the accretion disk of black holes.

Nakano, G. H.

Integration of the Reconfigurable Self-Healing eDNA Architecture in an Embedded System

In this work we describe the first real world case study for the self-healing eDNA (electronic DNA) architecture by implementing the control and data processing of a Fourier Transform Spectrometer (FTS) on an eDNA prototype. For this purpose the eDNA prototype has been ported from a Xilinx Virtex 5 FPGA to an embedded system consisting of a PowerPC and a Xilinx Virtex 5 FPGA. The FTS instrument features a novel liquid crystal waveguide, which consequently eliminates all moving parts from the instrument. The addition of the eDNA architecture to do the control and data processing has resulted in a highly fault-tolerant FTS instrument. The case study has shown that the early stage prototype of the autonomous self-healing eDNA architecture is expensive in terms of execution time.

Computer architecture

Earth Observing Scanning Polarimeter (EOSP), phase B

Evaluations performed during a Phase B study directed towards defining an optimal design for the Earth Observing Scanning Polarimeter (EOSP) instrument is summarized. An overview of the experiment approach is included which provides a summary of the scientific objectives, the background of the measurement approach, and the measurement method. In the instrumentation section, details of the design are discussed starting with the key instrument features required to accomplish the scientific objectives and a system characterization in terms of the Stokes vector/Mueller matrix formalism. This is followed by a detailing of the instrument design concept, the design of the individual elements of the system, the predicted performance, and a summary of appropriate instrument testing and calibration. The selected design makes use of key features of predecessor polarimeters and is fully compatible with the Earth Observing System spacecraft requirements.

Source record

Airflow resistivity instrument for in situ measurement on the earth's ground surface

An airflow resistivity instrument features a novel specimen holder, especially designed for in situ measurement on the earth's ground surface. This capability eliminates the disadvantages of prior intrusive instruments, which necessitate the removal of a test specimen from the ground. A prototype instrument can measure airflow resistivities in the range 10-5000 cgs rayl/cm, at specimen depths up to 15.24 cm (6 in.), and at differential pressures up to 2490.8 dyn sq cm (1 in. H2O) across the specimen. Because of the close relationship between flow resistivity and acoustic impedance, this instrument should prove useful in acoustical studies of the earth's ground surface. Results of airflow resistivity measurements on an uncultivated grass field for varying values of moisture content are presented.

Zuckerwar, A. J.

Cylindrical Crystal Imaging Spectrometer (CCIS) for cosmic X-ray spectroscopy

A "stigmatic" focusing, Bragg crystal spectrometer was developed and used for high spectral resolution X-ray emission line diagnostics on hot laboratory plasmas. The concept be applied at the focal plane of an orbiting X-ray telescope where it offers several advantages over conventional spectrometers, i.e., mechanical simplicity, high resolving power and sensitivity, simultaneous measurement of an extended segment of spectrum, and good imaging properties. The instrument features a simple, unambiguous, non-scanning spectrum readout that is not adversely affected by either spacecraft pointing error or source extent. The performance of the instrument is estimated in the context of the Advanced X-Ray Astrophysical Facility mission.

Schnopper, H. W.

The Next Generation Space Telescope (NGST): Science and technology

The scientific requirements and implications for the instruments and telescope design for the Next Generation Space Telescope (NGST) are described. A candidate concept is a deployable, 8 m diameter telescope, optimized for the near infrared region, but featuring instruments capable of observing up to 30 micrometers. The observatory is radiatively cooled to approximately 30 K.

Mather, John C.

Fiber-coupled high resolution infrared array spectrometer for the Kuiper Airborne Observatory

A novel cryogenic grating spectrometer (FCAS) is being designed for observations of volatiles in cometary and planetary atmospheres, and in newly forming planetary systems. The instrument features two-dimensional detector arrays coupled to a high-dispersion echelle by infrared fibers, and will achieve a spectral resolving power of about 40,000. The primary observational platform for this instrument will be the Kuiper Airborne Observatory, but it will also be configured for use at ground-based observatories. Initially, the spectrometer will use a 58 x 62, 1- to 5-micron InSb array. Larger-format IR arrays and arrays of different composition, will later be incorporated as they become available. The instrument will be used in two modes. The first uses a large format IR array in the spectral image plane for the customary one-dimensional spectral-one-dimensional spatial coverage. In the second mode, a massive, coherent bundle of infrared transmitting ZrF4 fibers will be installed after the dispersive element, to reformat the two-dimensional array into an elongated one-dimensional array for wide spectral coverage, allowing multiple lines to be measured in a single integration with high sensitivity. The overall instrument design is discussed, and the system sensitivity is estimated.

Glenar, D. A.

Measurement of model propulsion system noise in a low-speed wind tunnel

Methods are presented for making overall and directional acoustic measurements with forward velocity in the Lewis 9 x 15 V/STOL wind tunnel. Overall acoustic measurements are discussed; the acoustic calibration methods, instrumentation features, and types of experiments are presented. Selected data are presented as examples of the various types of overall measurements that are possible. The method of making directional acoustic measurements is presented, and the necessary alterations to the tunnel, specialized acoustic instrumentation, and calibration details are described. The results indicate that relative overall acoustic measurements can be made successfully and that directional acoustic measurements are feasible.

Diedrich, J. H.

Measurement of model propulsion system noise in a low-speed wind tunnel

Methods are presented for making overall and directional acoustic measurements with forward velocity in the Lewis 9 x 15 V/STOL Wind Tunnel. Overall acoustic measurements are discussed first. The acoustic calibration methods, instrumentation features, and types of experiments are presented. Selected data are presented as examples of the various types of overall measurements that are possible. The method of making directional acoustic measurements is then presented. The necessary alterations to the tunnel, specialized acoustic instrumentation, and calibration details are described. The results indicate that relative overall acoustic measurements can be made successfully and that directional acoustic measurements are feasible.

Diedrich, J. H.

Space vehicle glow measurements on STS 41-D

A flight experiment using a hand-held, image-intensified spectrographic camera was performed on mission 41-D. The instrument enabled the photographic documentation of the position of the spectral slit on the image to be subjected to spectrographic analysis. Because of this instrument feature, the spectrum of the glow on the Shuttle tail pod could be clearly separated from spectrum of the scattered light from the Orbiter. From the measurements it is clear that the spectrum of the glow is a continuum in the passband of the instrument between 4200 A and 8000 A. The measured spectral resolution of the instrument was 35 A. The scattered light from the Orbiter surfaces distinctly show the components of the earth's airglow at 5577 A and 7620 A. On the same flight material samples were also carried by the Orbiter attached to the Remote Manipulating System arm. These samples were representative of the material overcoatings used on the space telescope. The altitude of the 41-D flight was 290 km, instead of the 220 km which was originally planned for this experiment. The signal to noise ratio in the material glow discrimination experiment was quite low. This made it difficult to draw strong conclusions regarding the glow propensity of the materials. Nevertheless it was clear that polyethylene produces a very weak glow, while most black overcoating materials produce significant glow. MgF2 was also found to produce a relatively intense glow.

Mende, S. B.

Mechanical design of a parallel flexure-based RADSI instrument for curved x-ray mirror metrology

Modern synchrotron x-ray beamlines demand reflective optics with higher surface profile accuracy to achieve diffraction-limited focusing. This necessitates advanced metrology instruments capable of delivering repeatable measurements in the nanometer to sub-nanometer range. Slope ranges exceeding 15 mrad (0.86°) and greater pose significant challenges for mirror metrology using conventional interferometric methods. Here, to address this, we present a new relative angle determinable stitching interferometry instrument featuring a parallel flexure-based mechanical design. This approach enhances vibration and thermal stability while maintaining a compact and lightweight system. Initial measurements of a cylindrical mirror with a 16 m radius of curvature and a slope range of 5 mrad demonstrate nanometer-level repeatability. Comprehensive system characterization suggests the potential for achieving sub-nanometer repeatability with further refinement to the instrument.

36 MATERIALS SCIENCE

Prototype Global Analysis of LISA Data with Multiple Source Types

The novel data analysis challenges posed by the Laser Interferometer Space Antenna (LISA) arise from the overwhelmingly large number of astrophysical sources in the measurement band and the density with which they are found in the data. Robust detection and characterization of the numerous gravitational wave sources in LISA data can not be done sequentially, but rather through a simultaneous global fit of a data model containing the full suite of astrophysical and instrumental features present in the data. While previous analyses have focused on individual source types in isolation, here we present the first demonstration of a LISA global fit analysis containing combined astrophysical populations. The prototype pipeline uses a blocked Metropolis Hastings algorithm to alternatingly fit to a population of ultra compact galactic binaries, known “verification binaries” already identified by electromagnetic observations, a population of massive black hole mergers, and an instrument noise model. The Global LISA Analysis Software Suite (GLASS) is assembled from independently developed samplers for the different model components. The modular design enables flexibility to future development by defining standard interfaces for adding new, or updating additional, components to the global fit without being overly prescriptive for how those modules must be internally designed. The GLASS pipeline is demonstrated on data simulated for the LISA Data Challenge 2b. Results of the analysis and a road-map for continued development are described in detail.

Gravitational Waves

The High Resolution Microcalorimeter Soft X-Ray Spectrometer for the Astro-H Mission

We are developing the Soft X-Ray Spectrometer for the JAXA Astro-H mission. The instrument features a 5 eV, 36-pixel array of micro calorimeters designed for high spectral resolution from 0.3-12 keV at the focus of an x-ray mirror, providing a field of view of3 x 3 arcmin. The principal components of the spectrometer are the microcalorimeter detector system, a 3-stage ADR and dewar. The dewar is a long-life, hybrid design with a superfluid He cryostat, Joule-Thomson cooler, and Stirling coolers. We describe the present design of the SXS instrument and initial engineering model test results.

Kelley, Richard L.

Performance Assessments of the SNPP and N20 VIIRS DNB Using Observations of Bright Stars

The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the Suomi-NPP (SNPP) and NOAA-20 (N20) spacecrafts is a multi-spectral Earth-observing instrument with spectral channels ranging from the visible to the long-wave infrared. In addition to these spectral channels, the VIIRS instrument features a panchromatic Day/Night band (DNB) with 3 gain stages (low, mid, and high) which allows for Earth-view (EV) radiance retrievals over 7 orders of magnitude. The DNB is able to collect data ranging from dim city lights during nighttime up to reflected sunlight from cloud-tops during daytime. The DNB data collection is divided into 32 aggregation modes, where sub-pixel aggregation is used to maintain a nearly constant pixel footprint on ground during EV data collection throughout each scan. The DNB is also sensitive enough to observe bright stars through the instrument space-view (SV) port. Data from these bright stars can be used to track the temporal stability of the sensor gain and as a method of intercomparison between the two VIIRS instruments. In this work, we will present several sensor performance assessments of the VIIRS DNB using stars. In addition to the sensor gain trending, these assessments will include a comparison of the differences between the daytime and nighttime data due to the effects of stray-light, a comparison of the measured signal as a function of aggregation mode, a comparison between the two high-gain sub-stages, and half-angle mirror side for both the SNPP and N20 VIIRS DNB.

VIIRS

Remote sensing X-ray spectrometer

Spectrometer measures chemical composition of lunar rocks by remote sensing from orbit and senses lunar X-rays produced by interaction of solar X-rays and elements on the lunar surface. Instrument features high sensitivity, data handling system that accumulates and prepares data for telemetry, and automatic calibration.

Adler, I.

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.