Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INDIUM 106”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A = 106

The 1994 evaluation on mass A = 106 has been revised, taking into account all data available before May 2007. Detailed experimental information is presented from the neutron rich nucleus {sup 106}Y to the neutron deficient {sup 106}Te nucleus. All conversion coefficients have been calculated with BRICC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structure of dipole bands in {sup 106}In

High spin states in neutron-deficient {sup 106}In were investigated using {sup 78}Se({sup 32}S,p3n) reaction at 125 MeV. The level scheme is extended up to 7 MeV of excitation energy for the negative parity states constituting four dipole bands, and the positive parity states which mainly exhibit single-particle excitations are extended up to 5 MeV. Projected deformed Hartree-Fock calculations were carried out to understand the configurations of different bands in this nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Penning trap mass measurements of {sup 99-109}Cd with the ISOLTRAP mass spectrometer, and implications for the rp process

Penning trap mass measurements of neutron-deficient Cd isotopes {sup 99-109}Cd have been performed with the ISOLTRAP mass spectrometer at ISOLDE/CERN, all with relative mass uncertainties below 3{center_dot}10{sup -8}. A new mass evaluation has been performed. The mass of {sup 99}Cd has been determined for the first time, which extends the region of accurately known mass values toward the doubly magic nucleus {sup 100}Sn. The implication of the results on the reaction path of the rp process in stellar x-ray bursts is discussed. In particular, the uncertainty of the abundance and the overproduction created by the rp-process for the mass A=99 are demonstrated by reducing the uncertainty of the proton-separation energy of {sup 100}InS{sub p}({sup 100}In) by a factor of 2.5.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Contactless electroreflectance and theoretical studies of band gap and spin-orbit splitting in InP{sub 1−x}Bi{sub x} dilute bismide with x ≤ 0.034

Contactless electroreflectance is applied to study the band gap (E{sub 0}) and spin-orbit splitting (Δ{sub SO}) in InP{sub 1−x}Bi{sub x} alloys with 0 < x ≤ 0.034. The E{sub 0} transition shifts to longer wavelengths very significantly (−83 meV/% Bi), while the E{sub 0} + Δ{sub SO} transition shifts very weakly (−13 meV/% Bi) with the rise of Bi concentration. These changes in energies of optical transitions are discussed in the context of the valence band anticrossing model and ab initio calculations. Shifts of E{sub 0} and E{sub 0} + Δ{sub SO} transitions, obtained within ab-initio calculations, are −106 and −20 meV per % Bi, respectively, which is in a good agreement with experimental results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tuning exciton energy and fine-structure splitting in single InAs quantum dots by applying uniaxial stress

Exciton and biexciton emission energies as well as excitonic fine-structure splitting (FSS) in single InAs/GaAs quantum dots (QDs) have been continuously tuned in situ in an optical cryostat using a developed uniaxial stress device. With increasing tensile stress, the red shift of excitonic emission is up to 5 nm; FSS decreases firstly and then increases monotonically, reaching a minimum value of approximately 10 μeV; biexciton binding energy decreases from 460 to 106 μeV. This technique provides a simple and convenient means to tune QD structural symmetry, exciton energy and biexciton binding energy and can be used for generating entangled and indistinguishable photons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-557: Measuring Neutron Activation of Cardiac Devices Irradiated During Proton Therapy Using Indium Foils

Purpose: Measuring Neutron Activation of Cardiac devices Irradiated during Proton Therapy using Indium Foils Methods: The foils had dimensions of 25mm x 25mm x 1mm. After being activated, the foils were placed in a Canberra Industries well chamber utilizing a NaI(Tl) scintillation detector. The resulting gamma spectrum was acquired and analyzed using Genie 2000 spectroscopy software. One activation foil was placed over the upper, left chest of RANDO where a pacemaker would be. The rest of the foils were placed over the midline of the patient at different distances, providing a spatial distribution over the phantom. Using lasers and BBs to align the patient, 200 MU square fields were delivered to various treatment sites: the brain, the pancreas, and the prostate. Each field was shot at least a day apart, giving more than enough time for activity of the foil to decay (t1=2 = 54.12 min). Results: The net counts (minus background) of the three aforementioned peaks were used for our measurements. These counts were adjusted to account for detector efficiency, relative photon yields from decay, and the natural abundance of 115-In. The average neutron flux for the closed multi-leaf collimator irradiation was measured to be 1.62 x 106 - 0.18 x 106 cm2 s-1. An order of magnitude estimate of the flux for neutrons up to 1 keV from Diffenderfer et al. gives 3 x 106 cm2 s-1 which does agree on the order of magnitude. Conclusion: Lower energy neutrons have higher interaction cross-sections and are more likely to damage pacemakers. The thermal/slow neutron component may be enough to estimate the overall risk. The true test of the applicability of activation foils is whether or not measurements are capable of predicting cardiac device malfunction. For that, additional studies are needed to provide clinical evidence one way or the other.

07 ISOTOPE AND RADIATION SOURCES↗

Use of Local {sup 111}In-Capromab Pendetide Scan Results to Predict Outcome After Salvage Radiotherapy for Prostate Cancer

Purpose: The {sup 111}In-capromab pendetide scan (ProstaScint; Cytogen Corp., Princeton NJ) is approved by the Food and Drug Administration to evaluate increasing prostate-specific antigen (PSA) levels after radical prostatectomy. This study evaluated the role of prostate bed {sup 111}In-capromab pendetide scan findings to predict response to salvage radiotherapy (RT). Methods and Materials: Forty patients who had PSA recurrence after radical prostatectomy and a {sup 111}In-capromab pendetide scan immediately before salvage prostate bed RT (median, 66 Gy) were identified from the Duke Prostate Center database. Patients with distant uptake of capromab pendetide or long-term androgen deprivation therapy were excluded. Median follow-up after salvage RT was 2.7 years. Patient demographic, clinical, and pathologic characteristics; PSA values; and {sup 111}In-capromab pendetide scan results were retrospectively analyzed. A PSA failure after salvage RT was defined as PSA level greater than 0.2 ng/ml. Data were combined with other published results in a secondary pooled analysis of 106 patients. Results: {sup 111}In-Capromab pendetide findings included 20 patients with negative scan results and 20 with locally positive scan results. Two-year progression-free survival rates were 60% for patients with a negative scan result and 74% for those with a locally positive scan result (p = 0.49). Combined analysis did not show a difference in outcome based on local {sup 111}In-capromab pendetide scan result. Conclusion: For patients without distant signal detected by using {sup 111}In-capromab pendetide scan, patients with locally positive scan findings did not have statistically different progression-free survival than those with a negative scan result, suggesting that salvage RT may be successful in patients with either a locally positive or negative {sup 111}In-capromab pendetide scan result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗