Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INDIUM 103”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A = 103

The 2001 evaluation on mass A = 103 (2001De37) has been revised, taking into account all data available before March 2009. Experimental information is presented from the neutron rich nucleus {sup 103}Sr to the neutron deficient {sup 103}Sn nucleus. The experimental information on excited states for {sup 103}Sr and {sup 103}y is very scarce New (HI, xn{gamma}) data sets for several nuclides have been evaluated and new and more accurate data for {gamma} intensities and multipolarities obtained. The BRICC code has been used for the calculation of conversion coefficients.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-378: Evaluation of An Analytical Model for the Inter-Seed Attenuation Effect in 103-Pd Multi-Seed Implant Brachytherapy

Purpose: Brachytherapy treatment planning systems based on TG-43 protocol calculate the dose in water and neglects the heterogeneity effect of seeds in multi-seed implant brachytherapy. In this research, the accuracy of a novel analytical model that we propose for the inter-seed attenuation effect (ISA) for 103-Pd seed model is evaluated. Methods: In the analytical model, dose perturbation due to the ISA effect for each seed in an LDR multi-seed implant for 103-Pd is calculated by assuming that the seed of interest is active and the other surrounding seeds are inactive. The cumulative dosimetric effect of all seeds is then summed using the superposition principle. The model is based on pre Monte Carlo (MC) simulated 3D kernels of the dose perturbations caused by the ISA effect. The cumulative ISA effect due to multiple surrounding seeds is obtained by a simple multiplication of the individual ISA effect by each seed, the effect of which is determined by the distance from the seed of interest. This novel algorithm is then compared with full MC water-based simulations (FMCW). Results: The results show that the dose perturbation model we propose is in excellent agreement with the FMCW values for a case with three seeds separated by 1 cm. The average difference of the model and the FMCW simulations was less than 8%±2%. Conclusion: Using the proposed novel analytical ISA effect model, one could expedite the corrections due to the ISA dose perturbation effects during permanent seed 103-Pd brachytherapy planning with minimal increase in time since the model is based on multiplications and superposition. This model can be applied, in principle, to any other brachytherapy seeds. Further work is necessary to validate this model on a more complicated geometry as well.

60 APPLIED LIFE SCIENCES↗

High-accuracy coupled cluster calculations of atomic properties

The four-component Fock-space coupled cluster and intermediate Hamiltonian methods are implemented to evaluate atomic properties. The latter include the spectra of nobelium and lawrencium (elements 102 and 103) in the range 20000-30000 cm{sup −1}, the polarizabilities of elements 112-114 and 118, required for estimating their adsorption enthalpies on surfaces used to separate them in accelerators, and the nuclear quadrupole moments of some heavy atoms. The calculations on superheavy elements are supported by the very good agreement with experiment obtained for the lighter homologues.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultrasound Evaluation of Thyroid Gland Pathologies After Radiation Therapy and Chemotherapy to Treat Malignancy During Childhood

Purpose: The purpose of this study was to evaluate correlations between treatment of malignancy by radiation therapy during childhood and the occurrence of thyroid gland pathologies detected by ultrasonography in follow-up examinations. Methods and Materials: Reductions of thyroid gland volume below 2 standard deviations of the weight-specific mean value, occurrence of ultrasonographically detectable thyroid gland pathologies, and hypothyroidism were retrospectively assessed in 103 children and adolescents 7 months to 20 years of age (median: 7 years of age) at baseline (1997-2013) treated with chemoradiation therapy (with the thyroid gland dose assessable) or with chemotherapy alone and followed by ultrasonography and laboratory examinations through 2014 (median follow-up time: 48 months). Results: A relevant reduction of thyroid gland volume was significantly correlated with thyroid gland dose in univariate (P<.001) and multivariate analyses for doses above 2 Gy. Odds ratios were 3.1 (95% confidence interval: 1.02-9.2; P=.046) for medium doses (2-25 Gy) and 14.8 (95% confidence interval: 1.4-160; P=.027) for high doses (>25 Gy). Thyroid gland dose was significantly higher in patients with thyroid gland pathologies during follow-up (P=.03). Univariate analysis revealed significant correlations between hypothyroidism and thyroid gland dose (P<.001). Conclusions: Ultrasonographically detectable changes, that is, volume reductions, pathologies, and hypothyroidism, after malignancy treatment during childhood are associated with thyroid gland dose. Both ultrasonography and laboratory follow-up examinations should be performed regularly after tumor therapy during childhood, especially if the treatment included radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

InSb linear multiplexed FPAs for the CRAF/Cassini visible and infrared mapping spectrometer

This paper provides a review of a custom multiplexer circuit designed for use with a 256 element InSb linear array in the CRAF/Cassini VIMS instruments. The requirements, operation noise model and test results from a prototype 1 x 64 array are discussed. The infrared focal plane array (FPA) preliminary design and the impact of the new multiplexer on the instruments' predicted performance will be discussed. Emphasis will be placed on the multiplexer that was designed for the CRAF/Cassini missions. The FPA assembly combines electronic and optical components into a single hermetically sealed hybrid package. The detector configuration is that of a linear dual-multiplexed indium antimonide array with 256 elements, each 103 x 200 on 123-micron centers.

Niblack, Curtiss↗

Halving the Casimir force with conductive oxides: Experimental details

This work is an extended version of a paper published previously [S. de Man et al., Phys. Rev. Lett. 103, 040402 (2009)], where we presented measurements of the Casimir force between a gold-coated sphere and a plate coated with either gold or an indium tin oxide (I TO) layer. The experiment, which was performed in air, showed that I TO conducts sufficiently to prevent charge accumulation but is still transparent enough to halve the Casimir attraction when compared to gold. Here we report all the experimental details that, owing to the limited space available, were omitted in the previous article. We discuss the performance of our setup in terms of stability of the calibration procedure and reproducibility of the Casimir force measurement. We also introduce and demonstrate a technique to obtain the spring constant of our force sensor. Furthermore, we present a thorough description of the experimental method, a comprehensive explanation of data elaboration and error analysis, and a complete characterization of the dielectric function and of the surface roughness of the samples used in the actual experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Penning trap mass measurements of {sup 99-109}Cd with the ISOLTRAP mass spectrometer, and implications for the rp process

Penning trap mass measurements of neutron-deficient Cd isotopes {sup 99-109}Cd have been performed with the ISOLTRAP mass spectrometer at ISOLDE/CERN, all with relative mass uncertainties below 3{center_dot}10{sup -8}. A new mass evaluation has been performed. The mass of {sup 99}Cd has been determined for the first time, which extends the region of accurately known mass values toward the doubly magic nucleus {sup 100}Sn. The implication of the results on the reaction path of the rp process in stellar x-ray bursts is discussed. In particular, the uncertainty of the abundance and the overproduction created by the rp-process for the mass A=99 are demonstrated by reducing the uncertainty of the proton-separation energy of {sup 100}InS{sub p}({sup 100}In) by a factor of 2.5.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In Adsorption on Si(112) and its Impact on Ge Growth

The change of the Si(112) surface morphology and structure induced by In adsorption, as well as the impact of In preadsorption on the growth kinetics and island morphology in Ge/Si(112) epitaxy, has been investigated by means of low-energy electron microscopy and diffraction. The intrinsically faceted Si(112) surface is smoothed upon In saturation. In contrast to a previously reported (7 x 1) reconstruction (reported in a recent work of Gai et al.), we observe a [(3 + x) x 1] superstructure, with {approx} 1/2. This is attributed to the coexistence of (3 x 1) and (4 x 1) building blocks with In vacancies. The presence of such vacancy rows is confirmed by the saturation of the [(3 + x) x 1] structure at about 0.8 monolayers. Ge growth on In-saturated Si(112) leads to the formation of 3-D islands, the morphology of which depends on the growth temperature. At 450 C, isotropic and dashlike islands are observed, whereas at 500 C, larger islands with a triangular outline are found. The orientation of the side facets of these triangular islands have been identified to be (111), (013), and (103). The dependence of the island density on the growth temperature indicates an enhanced Ge surface diffusion, as compared with growth on bare Si(112).

36 MATERIALS SCIENCE↗

A 128 x 128 InGaAs detector array for 1.0 - 1.7 microns

A two-dimensional 128 x 128 detector array for the 1.0 - 1.7 micron spectral region has been demonstrated with indium gallium arsenide. The 30 micron square pixels had 60 micron spacing in both directions and were designed to be compatible with a 2D Reticon multiplexer. Dark currents below 100 pA, capacitance near 0.1 pF, and quantum efficiencies above 80 percent were measured. Probe maps of dark current and quantum efficiency are presented along with pixel dropout data and wafer yield which was as high as 99.89 percent (7 dropouts) in an area of 6528 pixels and 99.37 percent (103 dropouts) over an entire 128 x 128 pixel region.

Olsen, G.↗

High-performance self-aligned inversion-channel In{sub 0.53}Ga{sub 0.47}As metal-oxide-semiconductor field-effect-transistors by in-situ atomic-layer-deposited HfO{sub 2}

Self-aligned inversion-channel In{sub 0.53}Ga{sub 0.47}As metal-oxide-semiconductor field-effect-transistors (MOSFETs) have been fabricated using the gate dielectrics of in-situ directly atomic-layer-deposited (ALD) HfO{sub 2} followed by ALD-Al{sub 2}O{sub 3}. There were no surface pretreatments and no interfacial passivation/barrier layers prior to the ALD. TiN/Al{sub 2}O{sub 3} (4 nm)/HfO{sub 2} (1 nm)/In{sub 0.53}Ga{sub 0.47}As/InP MOS capacitors exhibited well-behaved capacitance-voltage characteristics with true inversion behavior, low leakage current densities of ∼10{sup −8} A/cm{sup 2} at ±1 MV/cm, and thermodynamic stability at high temperatures. Al{sub 2}O{sub 3} (3 nm)/HfO{sub 2} (1 nm)/In{sub 0.53}Ga{sub 0.47}As MOSFETs of 1 μm gate length, with 700 °C–800 °C rapid thermal annealing in source/drain activation, have exhibited high extrinsic drain current (I{sub D}) of 1.5 mA/μm, transconductance (G{sub m}) of 0.84 mS/μm, I{sub ON}/I{sub OFF} of ∼10{sup 4}, low sub-threshold swing of 103 mV/decade, and field-effect electron mobility of 1100 cm{sup 2}/V · s. The devices have also achieved very high intrinsic I{sub D} and G{sub m} of 2 mA/μm and 1.2 mS/μm, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗