Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICSBEP Benchmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Validation and Independent Uncertainty Analysis of the MIX-SOL-THERM-003 ICSBEP Benchmark

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) was started in 1992 by the United States Department of Energy and later in 1995 became an international project with contributions from 22 countries. The project is now organized by the OECD (Organisation for Economic Co-operation and Development) Nuclear Energy Agency (NEA). In its most recent iteration, the ICSBEP handbook contains over five thousand evaluations of critical, near-critical, and subcritical experiments conducted in facilities all around the world. These benchmarks serve as valuable information for criticality safety engineers who can use them to validate calculation techniques and establish minimum subcritical margins for operations with fissionable materials. The benchmarks in the handbook are categorized by their fissile material composition, material form (oxide, solution, or metal), and fission energy spectra. This is especially useful for those looking for benchmarks similar to a system they are working on to compare methods and identify trends. The ICSBEP Handbook Uncertainty Guide is document outlining recommended practices and methods for determining uncertainties in these benchmarks. Quantifying these uncertainties thoroughly is crucial as it allows a higher degree of confidence that data used from them is valid and relevant. The guide stresses the importance of a thorough and well documented uncertainty analysis when evaluating an experiment. All measured values of a system, whether they be dimensions or material compositions, have a certain amount of uncertainty associated with them and can be analyzed one by one to determine their effects on the system. Many evaluated benchmarks in the handbook present this in detail, however some do not, mostly earlier evaluations performed in the 1990’s and early 2000’s. Recently at Los Alamos National Laboratory (LANL), the Nuclear Criticality Safety Division (NCSD) of LANL has been validating MCNP6.2 ® input files of criticality benchmarks for use by Whisper, a criticality safety code developed at LANL. This effort is also part of the OECD NEA Working Party on International Nuclear Data Evaluation Co-operation (WPEC) Subgroup 45, also known as Validation of Nuclear Data Libraries (VaNDaL). The goal of VaNDaL is to compile a set of validated simulation inputs for use in validating nuclear data and simulation codes. As part of these efforts, one of the benchmarks reviewed was the MIX SOL-THERM-003 ICSBEP benchmark. This paper provides an independent uncertainty analysis of this benchmark experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ICSBEP Benchmarking Tutorial for DNCSH

As part of the DOE/NRC Collaboration for Criticality Safety Support for Commercial-Scale HALEU for Fuel Cycles and Transportation (DNCSH), a workshop was held on Teams on how to write a ICSBEP benchmark that meets modern standards. The workshop prepared people performing experiments and writing benchmarks so that they have an increased chance of submitting a benchmark that will be accepted. The workshop was led by experts from LANL, LLNL and Sandia.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ICSBEP Benchmark Template

The purpose of this document is to demonstrate the ability of LATEX to create an ICSBEP benchmark evaluation. Creating a large document in LATEX offers many benefits, such as automatic numbering of items such as tables and figures, and easier placement of objects in the page. Additionally, it is easier to have multiple styles of pages in the same document, and in general the handling of large documents (which evaluations very commonly are) is not problematic. The formatting of this document is meant to conform to both the standards of the document and formatting guide and established practices in order to make the creation of new evaluations a more streamlined process. This will also help reduce the benchmark-to-benchmark variation in style.

97 MATHEMATICS AND COMPUTING↗

Investigation of Delayed Neutron Sensitivities for Several ICSBEP Benchmarks using MCNP

The effective delayed neutron (β$_{eff}$) is a very important parameter for reactor and criticality applications. This parameter is equal to the difference in reactivity between delayed critical ($k_{eff}$ = 1, which requires both prompt and delayed neutrons to achieve criticality) and prompt critical ($k_p$ = 1, which requires only prompt neutrons to achieve criticality). This is often referred to as the delayed critical "window" (the region of criticality between delayed and prompt critical). β$_{eff}$ is a reactor kinetics parameters and depends on the nuclides in the system that undergo fission as well as the spectral characteristics of the system. Measurements of β$_{eff}$ have been performed for many criticality experiments. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond $k_{eff}$. Our team has recently investigated the use of pulsed spheres for nuclear data validation. Several other measurement methods are also of interest, including β$_{eff}$ (investigated here) and reactivity coefficients (investigated in a separate work at this same meeting). One focus of our work is to determine if other methods are complimentary to the critical experiments already utilized for nuclear data validation. This is important because if a method has similar sensitivities then it will not be particularly useful for nuclear data validation as it will provide the same information as the critical experiments already being used. Here "similar" could refer to several characteristics, one being the shape of a sensitivity profile over energy. In the future, these methods will be utilized (with both existing and new experiments) in machine learning algorithms for nuclear validation, similar to what is currently done for criticality experiments. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for that parameter. This work looks at one approach to estimate β$_{eff}$ sensitivities by utilizing $k_{eff}$ sensitivities within Monte Carlo N-Particle ® Code Version 6.2. This is applied to several criticality benchmarks. Results are compared and the benefits and limitations of this approach are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validating ENDF/B-VIII.1beta3 with LLNL Pulsed-Sphere Experiments and ICSBEP Benchmarks [Slides]

LPS experiments are not benchmarks but can provide valuable input. 22/1/24 LPS experiments are not benchmarks but can provide valuable input. LPS (run by Denise) help validate nuclear data up to 15 MeV. They test scattering and fission data. They have incomplete uncertainties from 2-8%. I take note when: (1) I see C/E differences above the peak and before late times => 20%. (2) Simulated results between libraries change by => 20% without a good explanation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Leakage Spectra Sensitivities for ICSBEP Benchmarks

Neutron leakage spectra have been measured, simulated, and investigated by many groups. These spectra have many uses, including determining shielding requirements and calculating dose for radiation protection purposes, validating nuclear data, and determining material composition. It has even been proposed to use measurements of neutron leakage spectra to determine the soil composition of Mars. As part of the Los Alamos National Laboratory (LANL) Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) Laboratory Directed Research Development (LDRD) project, the authors are working on developing methods to calculate sensitivities to neutron leakage spectra. This may allow nuclear data evaluators to better use neutron leakage spectra data to constrain or adjust nuclear data. This may also be particularly useful as many neutron leakage spectra measurements do not require fissile material and can be performed with well characterized neutron sources. Neutron leakage spectra measurements are usually performed by placing a detector at the outside of a nuclear system. This may be a reactor, a neutron generator, or a neutron source. Certain detection systems can use pulse height data to infer neutron energies, other detector systems rely on other ways of determining neutron energy (for example, a Bonner sphere with multiple moderator thicknesses can be used to measure neutron spectrum). These measurements typically rely on some unfolding of the measured results. For pulsed systems like the "Livermore Pulsed Spheres," time-of-flight information can also help to constrain the neutron energy spectra data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intrinsic value of the international benchmark projects, ICSBEP and IRPhEP, for advanced reactor development

The International Criticality Safety Benchmark Evaluation Project, a sanctioned program under the auspices of the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development, has been a highly successful and productive collaboration, now encompassing over 5,000 evaluated experimental benchmarks trusted and relied upon throughout the international nuclear communities. The success of this project led to the development of the International Reactor Physics Experiment Evaluation Project, which is dedicated to the evaluation of benchmark experiment data to sustain current and future reactor physics validation needs. These exemplary programs, and their widely utilized handbooks, serve as gold standards to which other databases strive to emulate. The purpose of the two projects is to preserve modern and legacy experimental data and evaluate it in a standardized handbook format to provide quality benchmarks to support modern and future criticality safety and reactor physics validation. These two projects have often served as the mechanism through which historic and modern neutronics experiments are evaluated and shared across international borders, to best provide unique, high-quality peer-reviewed, and often otherwise unavailable, benchmark data. The contents of these handbooks are utilized not only in validating criticality safety, reactor physics, and advanced reactor calculations, but are used to validate neutronics calculations and nuclear data for most other nuclear applications. This paper discusses both international programs and available content to enable advanced reactor design validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gaussian Process Optimization of Sensitivity-Based Similarity Metrics between New Nuclear Applications and New/Existing Benchmarks

Confidently designing safe, new nuclear criticality experiments requires expert judgement, which could take years of experience. Sensitivity/uncertainty (S/U) analysis can be utilized by less experienced individuals to conservatively estimate uncertainties in important parameters, such as k eff , in newly proposed nuclear applications. This type of analysis relies on matching new nuclear applications with existing benchmark experiments. The Whisper-1.1 software package included in MCNP6.2 ®1 contains more than 1,100 International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks. These benchmarks however rarely match new nuclear applications. The number of benchmarks available to match a given set of materials or geometric configurations varies significantly. Furthermore, recently performed benchmark experiments may not have had enough time to be properly documented and published. Benchmarks are vital for determining the accuracy of nuclear data and can assist nuclear physics and evaluators in improving nuclear data libraries. Exhaustively exploring the parameter space using simulations with software such as MCNP is too computationally expensive. In this work, Gaussian process optimization was implemented to reduce the number of simulations needed for optimization over multiple parameters. This optimization scheme was designed to selectively generate new benchmarks with high sensitivity-based similarity metrics to user-defined nuclear applications. Two benchmark models of spherically nested shells containing plutonium, uranium, tantalum, and water were used in the optimization to match an application containing plutonium plates, stacked in a tantalum reflector, surrounded by water.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gaussian Process Optimization of Sensitivity-Based Similarity Metrics between New Nuclear Applications and New/Existing Benchmarks [Slides]

This presentation discusses Nuclear Criticality Safety (NCS) and how designing safe, new nuclear criticality experiments requires expert judgement, which could take years of experience. Sensitivity/uncertainty (S/U) analysis can be utilized by less experienced individuals to conservatively estimate uncertainties in important parameters, such as k eff , in newly proposed nuclear experiments. The presentation poses the question of how this analysis can be performed and states that the answer lies in matching new nuclear experiments with existing benchmark experiments using similarity metrics. By increasing the criticality safety of the application in this work, higher mass limits could be used in PF-4 operations. Additionally, the presentation discusses MCNP6.2®, Whisper-1.1, the software that can be used in this analysis. Also discussed is the fact that International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks rarely match new nuclear applications and that there are significant differences in given set of materials and/or geometry. If there are no benchmarks that match the application, the presentation discusses the possibility of creating new benchmarks. In conclusion, this work presents a Gaussian process (GP) optimization scheme that was used to generate new benchmarks with the highest sensitivity-based similarity metrics to user-defined nuclear applications. The Gaussian process optimization successfully designed 3 new experimental benchmarks that were highly correlated to the application of interest and had k eff values near critical. Optimization over c k,i-r has shown that investigating specific isotope reactions for different applications is crucial to designing benchmark experiments. Partial contribution from Pu dominates c k similarity metric. Future work includes testing new stand-alone similarity metrics or new combinations of similarity metrics as the design criterion of this optimization – design criterion is application dependent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HEU Systems at Low Temperatures [Slides]

This project is sponsored by the Nuclear Criticality Safety Program (NCSP) in collaboration with Lawrence Livermore National Laboratory (LLNL) with a novel interest surrounding the transportation of fissile material: there is a concern regarding the inadvertent introduction of the material in a low-temperature environment. The low-temperature environment will be bounded down to temperatures not below -40 ºC, since this is the limit allotted for packages containing general radioactive material exposed to air. Eventually, the goal of the project is to conduct experiments spanning multiple fission energies at these low temperatures, concluding in an International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling Approach to Critical in the Upcoming CERBERUS Experiment

The planned Critical Experiment Reflected By coppEr to betteR Understand Scattering (CERBERUS) seeks to maximize sensitivity to elastic neutron scattering in the intermediate energy region (0.625 eV to 100 keV). It will be performed near the end of FY 2023 at the National Criticality Experiments Research Center (NCERC). Very few International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks are sensitive to copper in this region. Creating a benchmark sensitive in this area will make the Zeus benchmark series, an intermediate benchmark evaluation that uses a copper reflector, more useful for code and nuclear data validation. Approaching criticality in a safe manner is of utmost importance to avoid a criticality accident, which would present a safety concern and could cause damage to equipment. The two rules that are followed closely to ensure that a criticality accident does not occur are the 3/4 rule and the 1/2 rule. The 3/4 rule states that no more than 3/4 of a critical mass can be assembled by hand, and the 1/2 rule states that no more than 1/2 of the material expected to reach criticality, or 1/2 the distance needed to reach criticality, can be added before another measurement of the count rate has been taken. This work will discuss the approach to criticality as modeled in MCNP6® 1 particle transport code with the ENDF/B- VIII.0 cross-section library and the .00c data library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Critical Enriched Uranium Metal, 7-in.-diam. Cylinder with Thin Stainless Steel Top and Bottom Reflectors

Three 7 in. diameter highly enriched uranium (HEU; 93.17 wt % 235 U) metal cylinders were assembled on the vertical assembly machine of the Oak Ridge Critical Experiments Facility (ORCEF) with thin stainless steel reflectors (0.5, 1, and 2 in. thick) on the top and bottom. These experiments were performed during January 13–25, 1965, and used seven operational days at ORCEF. Before these experiments, unreflected and unmoderated 7 in. diameter HEU metal cylinders had been assembled to delayed criticality at ORCEF, and the results were benchmarked in HEU-MET-FAST-051. In addition to the critical experiments, the prompt neutron decay constant was measured via the Rossi-α technique, and those results are also presented in this report. To achieve near-delayed-critical systems, 5 × 5 × 0.03125 in. rectangular uranium metal parts were used on top of 7 in. diameter cylinders inside the top reflector. The delayed critical configuration from the three experiments described herein are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Benchmark Evaluation Program (ICSBEP), coordinated by the Nuclear Energy Agency, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainty in $k_{eff}$ is expected to be as low as ±0.0002. The prompt neutron time decay data could be the basis of an International Reactor Physics Evaluation Program benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Future of the MUSiC Experiment Data

The Measurements of Uranium Subcritical and Critical (MUSiC) experiment was a highly enriched uranium (HEU) experiment performed at the National Criticality Experiments Research Center (NCERC) executed between December 2020 and April 2021. The experiment intended to measure criticality and reactor kinetics parameters in a bare HEU system. The experiment concurrently measured radiation signatures from the system while utilizing different neutron source types. This was an attempt to benchmark both detectors and analysis techniques against one another for identical measurements. The experiment consisted of the Rocky Flats HEU hemi-shells constructed into ten configurations spanning between deeply subcritical (about 14 kgs) to supercritical (about 60 kgs). Two of the ten configurations were supercritical and the other eight were subcritical. The two supercritical configurations, often referred to as the critical configurations, were documented into an International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmark evaluation and submitted to the technical review group (TRG). The subcritical configurations of the MUSiC experiment were examined using three different detection systems. The systems include: the NoMAD He-3 neutron detector which consists of 15 He-3 tubes surrounded by a polyethylene matrix, a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD), and a trans-stilbene organic scintillator array (OSCAR) provided by the University of Michigan. The NoMAD and RAM-RODD data are planned to be evaluated in two separate ICSBEP evaluations utilizing neutron noise methods such as Feynman Variance-to-Mean, Rossi-α and the pulsed neutron source method. Each of the subcritical configurations were examined using three different source types including: a Cf-252 source in the center, with only the intrinsic neutron source in the HEU, and with an external D-T neutron generator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity-based Similarity Metrics for New Experiment Design Optimization

The nuclear data used in advanced reactor simulations requires validation. Data from nuclear criticality experiments can provide this validation. New nuclear criticality experiment design requires extensive knowledge and expert judgement such that the experimental design parameters are selected in such a way to keep the experiment subcritical. To aide in this experimental design process, professionals can utilize sensitivity and uncertainty analysis. Sensitivity and uncertainty analysis relies on matching new application experiments with currently existing benchmark experiments. Currently, there is functionality in the Whisper 1.1 software package to calculate a similarity metric based on neutron multiplication factor sensitivity coefficients between a new application designed by the user and existing International Criticality Safety Benchmark Experiment Project (ICSBEP) benchmarks. The Whisper 1.1 software package is included in Monte Carlo N-Particle ® Code Version 6.21 (MCNP ® 6.2). This work is geared toward expanding this capability to new similarity metrics based on beta-effective sensitivity coefficients and reactivity coefficient sensitivity coefficients. While the investigation of these sensitivity coefficients is presented in detail in separate works at this same conference, this work will be primarily focused on studying the similarity metrics in more detail. These similarity metrics will then be incorporated into the optimization algorithms used for experiment design in EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data), which is a Los Alamos National Laboratory (LANL) project designed to constrain nuclear data of interest, such that adjustments can be made to possible inaccuracies. A more detailed optimization can be subsequently performed by breaking down these similarity metrics by isotope, reaction, and energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The PARADIGM Project: Case Study in Balancing Experiment Uncertainty with Design simplicity

Accurate nuclear data are required for simulations of many applications including nuclear criticality safety. Actinide nuclear data at intermediate energies (from 1 to 100s of keV) are imprecise and inaccurate, because of scarce differential data, and an insufficient theory approach to capture the structures expected in the data to yield evaluated nuclear data, and lack of integral data for proper validation. This is a known deficiency but has proved challenging to address. More specifically, only 5% of integral experiments in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmark suite address intermediate energies (Fig. 1). Associated calculated effective multiplication factor, k eff , values for these experiments are far outside the experimental uncertainties and are 25× further from experiment than for fast energies. These differences could either stem from systematic biases in nuclear data, experiments or both. The goal of the PARADIGM (PARallel Approach of Differential and InteGral Measurements) project is to significantly reduce (by more than tens of percent) the uncertainties of intermediate energy actinide nuclear data. The PARADIGM project designed and intends to execute LANSCE (Los Alamos Neutron Science CEnter) and NCERC (National Criticality Experiments Research Center) intermediate experiments in parallel. They will specifically address a high priority nuclear data need—reducing bias and uncertainty in intermediate plutonium nuclear data. The two experiment will achieve that by informing each other and nuclear theory. By doing all these steps in parallel, the timeline to deliver improved nuclear data to users will significantly be reduced. This work will focus on the integral experiment final design and the balance of design and modeling simplicity while minimizing experiment uncertainty.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Integral Experiment Execution (CED-3b Report)

This report documents the experimental configurations and measurements for IER-518: Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Experiments. These measurements involved a series of subcritical configurations at the Sandia Critical Experiments (SCX) facility at Sandia National Laboratories (SNL). The purpose of these measurements was to produce time tagged neutron count data of configurations that exceed a subcritical multiplication of 20, which is the high end of the fundamental physics benchmarks currently available in the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP). These measurements leverage experimental configurations 1 and detector systems 2 from previously accepted ICSBEP benchmark evaluations, allowing evaluations of these measurements to be performed at greatly reduced cost.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗