Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hygroscopic growth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Seven years of aerosol scattering hygroscopic growth measurements from SGP: Factors influencing water uptake: Aerosol Scattering Hygroscopic Growth

Long-term measurements of changes in the aerosol scattering coefficient hygroscopic growth at the U.S. Department of Energy Southern Great Plains site provide information on the seasonal as well as size and chemical dependence of aerosol hygroscopic growth. Annual average sub 10 um fRH values (the ratio of aerosol scattering at 85%/40% RH) were 1.75 and 1.87 for the gamma and kappa fit algorithms, respectively. The study found higher growth rates in the winter and spring seasons that correlated with high aerosol nitrate mass fraction. FRH, exhibited strong, but differing correlations with the scattering Ångström exponent and backscatter fraction, two optical size-dependent parameters. The aerosol organic fraction had a strong influence, with fRH decreasing with increases in the organic mass fraction and absorption Ångström exponent and increasing with the aerosol single scatter albedo. Uncertainty analysis if the fit algorithms revealed high uncertainty at low scattering coefficients and slight increases in uncertainty at high RH and fit parameters values.

Jefferson, A.↗

Rapid measurement of RH-dependent aerosol hygroscopic growth using a humidity-controlled fast integrated mobility spectrometer (HFIMS)

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles is subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ∼10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth and its dependence on both size and RH.

54 ENVIRONMENTAL SCIENCES↗

Aerosol hygroscopic growth, contributing factors, and impact on haze events in a severely polluted region in northern China

This study investigates the impact of the aerosol hygroscopic growth effect on haze events in Xingtai, a heavily polluted city in the central part of the North China Plain (NCP), using a large array of instruments measuring aerosol optical, physical, and chemical properties. Key instruments used and measurements made include the Raman lidar for atmospheric water vapor content and aerosol optical profiles, the PC-3016A GrayWolf six-channel handheld particle and mass meter for atmospheric total particulate matter (PM) that has diameters less than 1 and 2.5 µ m (PM 1 and PM 2.5 , respectively), the aerosol chemical speciation monitor (ACSM) for chemical components in PM 1 , and the hygroscopic tandem differential mobility analyzer (H-TDMA) for aerosol hygroscopicity. The changes in PM 1 and PM 2.5 agreed well with that of the water vapor content due to the aerosol hygroscopic growth effect. Two cases were selected to further analyze the effects of aerosol hygroscopic growth on haze events. The lidar-estimated hygroscopic enhancement factor for the aerosol backscattering coefficient during a relatively clean period (Case I) was lower than that during a pollution event (Case II) with similar relative humidity (RH) levels of 80 %–91 %. The Kasten model was used to fit the aerosol optical hygroscopic growth factor (GF) whose parameter b differed considerably between the two cases, i.e., 0.1000 (Case I) versus 0.9346 (Case II). The aerosol acidity value calculated from ACSM data for Case I (1.35) was less than that for Case II (1.50) due to different amounts of inorganics such as NH 4 NO 3 , NH 4 HSO 4 , and (NH 4 ) 2 SO 4 . Model results based on H-TDMA data showed that aerosol hygroscopic growth factors in each size category (40, 80, 110, 150, and 200 nm) at different RH levels (80 %–91 %) for Case I were lower than those for Case II. For similar ambient RH levels, the high content of nitrate facilitates the hygroscopic growth of aerosols, which may be a major factor contributing to heavy haze episodes in Xingtai.

Chen, Jun↗

Particle_hygroscopicity_growth_factor_HFIMS_TRACER_2022_HOUSTON_IOP

This dataset contains high-temporal-resolution measurements of hygroscopic growth factors (GF), and instrument diagnostic/environmental parameters collected during the TRACER campaign using a coupled Differential Mobility Analyzer (DMA) and Fast Integrated Mobility Spectrometer (FIMS) system (HFIMS). The dataset consists of 49,645 time steps and covers 20 discrete growth factor bins (FIMS_GFbinc). The primary data product is the Probability Density Function (FIMS_cPDF), which characterizes aerosol hygroscopic growth behavior under controlled relative humidity conditions. Instrument operational parameters, including flow temperatures, relative humidities, pressures, and counts for both DMA and FIMS, are provided for quality assurance.

DMA_Dp_mean↗

Regularized inversion of aerosol hygroscopic growth factor probability density function: application to humidity-controlled fast integrated mobility spectrometer measurements

Abstract. Aerosol hygroscopic growth plays an important role in atmospheric particle chemistry and the effects of aerosol on radiation and hence climate. The hygroscopic growth is often characterized by a growth factor probability density function (GF-PDF), where the growth factor is defined as the ratio of the particle size at a specified relative humidity to its dry size. Parametric, least-squares methods are the most widely used algorithms for inverting the GF-PDF from measurements of the humidified tandem differential mobility analyzer (HTDMA) and have been recently applied to the GF-PDF inversion from measurements of the humidity-controlled fast integrated mobility spectrometer (HFIMS). However, these least-squares methods suffer from noise amplification due to the lack of regularization in solving the ill-posed problem, resulting in significant fluctuations in the retrieved GF-PDF and even occasional failures of convergence. In this study, we introduce nonparametric, regularized methods to invert the aerosol GF-PDF and apply them to HFIMS measurements. Based on the HFIMS kernel function, the forward convolution is transformed into a matrix-based form, which facilitates the application of the nonparametric inversion methods with regularizations, including Tikhonov regularization and Twomey's iterative regularization. Inversions of the GF-PDF using the nonparameteric methods with regularization are demonstrated using HFIMS measurements simulated from representative GF-PDFs of ambient aerosols. The characteristics of reconstructed GF-PDFs resulting from different inversion methods, including previously developed least-squares methods, are quantitatively compared. The result shows that Twomey's method generally outperforms other inversion methods. The capabilities of Twomey's method in reconstructing the pre-defined GF-PDFs and recovering the mode parameters are validated.

54 ENVIRONMENTAL SCIENCES↗

Hygroscopic growth and cloud droplet activation of xanthan gum as a proxy for marine hydrogels: HYGROSCOPICITY OF XG AS MARINE HYDROGEL

Knowledge of the physical characteristics and chemical composition of marine organic aerosols is needed for the quantification of their effects on cloud microphysical processes and solar radiative transfer. Here we use xanthan gum (XG)—a bacterial biopolymer—as a proxy for marine hydrogels. Measurements were performed for pure XG particles and mixtures of XG with sodium chloride, calcium nitrate, and calcium carbonate. The aerosol hygroscopicity parameter (κ) is derived from hygroscopic growth factor measurements (κ gf ) at variable water activity (a w ) and from cloud condensation nuclei activation efficiency (κ ccn ). The Zdanovskii, Stokes, and Robinson (ZSR) hygroscopicity parameter derived for multicomponent systems (κ mix , sol) is used to compare measurements of κ gf and κ ccn . Pure XG shows close agreement of κ gf (at aw = 0.9) and κccn of 0.09 and 0.10, respectively. Adding salts to the system results in deviations of κ gf (at a w = 0.9) from κ ccn . The measured κ gf and ZSR-derived hygroscopicity parameter (κ mix , sol) values for different solutions show close agreement at aw > 0.9, while κ gf is lower in comparison to κ mix , sol at a w < 0.9. The differences between predicted κmix, sol and measured κ gf and κ ccn values are explained by the effects of hydration and presence of salt ions on the structure of the polymer networks. Results from this study imply that at supersaturations of 0.1 and 0.5%, the presence of 30% sea salt by mass can reduce the activation diameter of pure primary marine organic aerosols from 257 to 156 nm and from 87 to 53 nm, respectively.

54 ENVIRONMENTAL SCIENCES↗

Aerosol Hygroscopic Growth, Mixing State, and Cloud Condensation Nuclei Activity during TRACER (Field Campaign Report)

Convective clouds play a critical role in the Earth’s climate system. Recent research has shown that a realistic representation of convective processes is critical to constraining climate sensitivity in global climate models. Theoretical and modeling studies showed that aerosols could have strong dynamic feedback to convection in warm and humid environments through enhancing ice-related processes and condensational growth. A few observation-based studies also suggested the influence of aerosols on convective cloud and precipitation properties. However, robust observational quantification of an aerosol effect on convective clouds isolated from other factors remains elusive. Understanding the impact of aerosol on convective clouds requires knowledge of the cloud condensation nuclei (CCN) spectrum, which represents the number of particles that uptake water and form cloud droplets as a function of supersaturation. The water uptake by aerosol is also of critical importance for the direct interaction of aerosol with radiation (i.e., aerosol direct effect) due to light scattering and absorption by aerosol. While both droplet activation under supersaturated conditions (i.e., relative humidity RH > 100%) and the hygroscopic growth under sub-saturated conditions (i.e., RH < 100%) are strongly influenced by particle hygroscopicity, the thermodynamic regimes and measurement methods are quite different. Aerosol particles, especially organic particles, can exhibit higher hygroscopicity for droplet activation than that for hygroscopic growth. In the subsaturated regime, the hygroscopicity of organic particles can also vary strongly with RH. However, global climate models usually treat organic species in aerosols with a constant hygroscopicity, potentially introducing substantial uncertainties in the quantification of aerosol radiative effects.

54 ENVIRONMENTAL SCIENCES↗

Rapid Assessment of Particle Hygroscopic Growth (Final Report)

This is a Phase I feasibility study to evaluate the accuracy and the speed for measuring particle hygroscopic growth using the water-based aerosol mobility imaging system already developed between Aerosol Dynamics Inc. and Brookhaven National Laboratory (BNL). One of the key parameters determining the impact of atmospheric aerosols on global climate is aerosol hygroscopicity, or uptake of water as a function of relative humidity. To date there is no rapid means of making this measurement over the range of particle sizes and humidity values of importance. This project aims to fill this need.

54 ENVIRONMENTAL SCIENCES↗

A humidity-controlled fast integrated mobility spectrometer (HFIMS) for rapid measurements of particle hygroscopic growth

We present a Humidity-controlled Fast Integrated Mobility Spectrometer (HFIMS) for rapid particle hygroscopicity measurements. The HFIMS consists of a differential mobility analyzer (DMA), a relative humidity (RH) control unit and a water-based FIMS (WFIMS) coupled in series. The WFIMS (Pinterich et al., 2017) combines the Fast Integrated Mobility Spectrometer (Kulkarni and Wang, 2006a, b) with laminar flow water condensation methodologies (Hering & Stolzenburg 2005; Spielman et al. 2017). Inside the WFIMS, particles of different electrical mobilities are spatially separated in an electric field, condensationally enlarged and imaged to provide 1-Hz measurements of size distribution spanning a factor of ~3 in particle diameter, sufficient to cover the entire range of growth factor for atmopheric aerosol particles at 90 % RH. By replacing the second DMA of a traditional hygroscopicity tandem DMA (HTDMA) system with the WFIMS, the HFIMS greatly increases the speed of particle growth factor measurement. The performance of the HFIMS was evaluated using NaCl particles with well-known hygroscopic growth behavior, and further through measurements of ambient aerosols. Results show that HFIMS can reproduce, within 2 % the literature values for hygroscopic growth of NaCl particles. NaCl deliquescence was observed between 76 % and 77 % RH in agreement with the theoretical value of 76.5 % (Ming and Russell, 2001), and efflorescence relative humidity (43 %) was found to lie within the RH range of 41 % to 56 % reported in the literature. Ambient data indicate that HFIMS can measure the hygroscopic growth of five standard dry particle sizes ranging from 35 to 165 nm within less than three minutes, which makes it about an order of magnitude faster than traditional HTDMA systems.

54 ENVIRONMENTAL SCIENCES↗

A Humidity-controlled Fast Integrated Mobility Spectrometer (HFIMS) for rapid measurements of particle hygroscopic growth

We present a Humidity-controlled Fast Integrated Mobility Spectrometer (HFIMS) for rapid particle hygroscopicity measurements. The HFIMS consists of a differential mobility analyzer (DMA), a relative humidity (RH) control unit and a water-based FIMS (WFIMS) coupled in series. The WFIMS (Pinterich et al., 2017) combines the Fast Integrated Mobility Spectrometer (Kulkarni and Wang, 2006a, b) with laminar flow water condensation methodologies (Hering and Stolzenburg, 2005; Spielman et al., 2017). Inside the WFIMS, particles of different electrical mobilities are spatially separated in an electric field, condensationally enlarged and imaged to provide 1-Hz measurements of size distribution spanning a factor of ~ 3 in particle diameter, sufficient to cover the entire range of growth factor for atmospheric aerosol particles at 90 % RH. By replacing the second DMA of a traditional hygroscopicity tandem DMA (HTDMA) system with the WFIMS, the HFIMS greatly increases the speed of particle growth factor measurement. The performance of the HFIMS was evaluated using NaCl particles with well-known hygroscopic growth behavior, and further through measurements of ambient aerosols. Results show that HFIMS can reproduce, within 2 % the literature values for hygroscopic growth of NaCl particles. NaCl deliquescence was observed between 76 % and 77 % RH in agreement with the theoretical value of 76.5 % (Ming and Russell, 2001), and efflorescence relative humidity (43 %) was found to lie within the RH range of 41 % to 56 % reported in the literature. Ambient data indicate that HFIMS can measure the hygroscopic growth of five standard dry particle sizes ranging from 35 to 165 nm within less than three minutes, which makes it about an order of magnitude faster than traditional HTDMA systems.

54 ENVIRONMENTAL SCIENCES↗

Hygroscopic growth of UO 2 F 2 nanoparticles

Hygroscopicity is an important physicochemical property of aerosol that describes the ability of a particle to uptake water. The hygroscopic properties of uranyl fluoride (UO 2 F 2 ) aerosol generated from a UF 6 hydrolysis reactor was investigated for the first time using a custom-built Humidified Tandem Differential Mobility Analyzer (HTDMA). The HTDMA is capable of measuring UO 2 F 2 nanoparticle growth determined by mobility size over a wide range of atmospheric humidity from dry conditions at <10% relative humidity (RH) to 85% RH. The hygroscopic properties were determined for nanoparticles as small as 3.5 nm in this study. Although the largest size of UO 2 F 2 nanoparticles was 80 nm, monodisperse aerosol with a mobility diameter of up to approximately 500 nm can be investigated using the HTDMA. Anhydrous UO 2 F 2 nanoparticles with a mobility diameter of 3.5 nm were shown to be highly hygroscopic with a deliquescence relative humidity (DRH) of 10%. Hydrates with a larger mobility diameter from 10 to 80 nm were non-hygroscopic with no observable DRH and limited water uptake up to 85% RH. Here, these results demonstrate the hygroscopic properties of UO 2 F 2 nanoparticles are highly variable and based on both the mobility size and hydration state. Hygroscopicity affects the physicochemical properties of UO 2 F 2 nanoparticles, including the aerosol phase state and viscosity, with impacts on aerosol growth, coagulation, and deposition that is critical for understanding the fate and transport of UO 2 F 2 nanoparticles in the atmosphere.

Hygroscopicity↗

Hygroscopic Growth of UO 2 F 2 Particles

Hygroscopicity is an important physicochemical property of aerosol that describes the ability of a particle to uptake water. The hygroscopic properties of uranyl fluoride (UO 2 F 2 ) aerosol generated from a UF 6 hydrolysis reactor was investigated for the first time using a custom-built Humidified Tandem Differential Mobility Analyzer (HTDMA). The HTDMA is capable of measuring UO 2 F 2 particle growth determined by mobility size over a wide range of atmospheric humidity from dry conditions at <10% relative humidity (RH) to 85% RH. The hygroscopic properties were determined for nanoparticles as small as 3.5 nm in this study. Anhydrous UO 2 F 2 particles with a mobility diameter of 3.5 nm were shown to be highly hygroscopic with a deliquescence relative humidity (DRH) of 10%. Hydrates with a larger mobility diameter of 10 to 80 nm were non-hygroscopic with no observable DRH and limited water uptake up to 85% RH. These results demonstrate the hygroscopic properties of UO 2 F 2 particles are highly variable and based on both the mobility size and hydration state. Hygroscopicity affects the physicochemical properties of UO 2 F 2 particles, including the aerosol phase state and viscosity, with impacts on aerosol growth, coagulation, and deposition that is critical for understanding the fate and transport of UO 2 F 2 particles in the atmosphere.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗