Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hydrophobic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Preferential hydrophobic interactions are responsible for a preference of D-amino acids in the aminoacylation of 5'-AMP with hydrophobic amino acids

We have studied the chemistry of aminoacyl AMP to model reactions at the 3' terminus of aminoacyl tRNA for the purpose of understanding the origin of protein synthesis. The present studies relate to the D, L preference in the esterification of 5'-AMP. All N-acetyl amino acids we studied showed faster reaction of the D-isomer, with a generally decreasing preference for D-isomer as the hydrophobicity of the amino acid decreased. The beta-branched amino acids, Ile and Val, showed an extreme preference for D-isomer. Ac-Leu, the gamma-branched amino acid, showed a slightly low D/L ratio relative to its hydrophobicity. The molecular basis for these preferences for D-isomer is understandable in the light of our previous studies and seems to be due to preferential hydrophobic interaction of the D-isomer with adenine. The preference for hydrophobic D-amino acids can be decreased by addition of an organic solvent to the reaction medium. Conversely, peptidylation with Ac-PhePhe shows a preference for the LL isomer over the DD isomer.

Non-NASA Center↗

Effects of Surface Hydrophobicity on Catalytic Transfer Hydrogenation of Styrene with Formic Acid in a Biphasic Mixture

Transfer hydrogenation (TH) of unsaturated hydrocarbons with formic acid (FA) is an attractive processing pathway for the reduction of lignocellulosic pyrolysis oils. The low solubility of hydrophobic bio-oil species in water and FA in oil necessitates the use of a biphasic system as the reaction environment. Here, we report the effects of Pd/silica catalyst surface wettability on the TH reaction rate. Modification of the surface with short chain (C1–C4) alkyl silanes resulted in an increase in the reaction rate as compared to the unmodified catalyst. In contrast, modification of the surface with sulfonate (hydrophilic) and C18 alkyl silanes (hydrophobic) resulted in a decrease in the reaction rate as compared to the unmodified catalyst. Here, the results are discussed in terms of the catalyst interfacial activity and relative affinity of the reagents to the Pd active sites. An observed change in the apparent reaction order in styrene for a hydrophilic catalyst suggests that changing catalyst surface wettability from hydrophilic to hydrophobic resulted in a switch from a transport-limited to a kinetic-limited reaction regime.

09 BIOMASS FUELS↗

Ion Exchange Gels Allow Organic Electrochemical Transistor Operation with Hydrophobic Polymers in Aqueous Solution

Conjugated-polymer-based organic electrochemical transistors (OECTs) are being studied for applications ranging from biochemical sensing to neural interfaces. While new polymers that interface digital electronics with the aqueous chemistry of life are being developed, the majority of high-performance organic transistor materials are poor at transporting biologically relevant ions. Here, the operating mode of an organic transistor is changed from that of an electrolyte-gated organic field-effect transistor (EGOFET) to that of an OECT by incorporating an ion exchange gel between the active layer and the aqueous electrolyte. This device works by taking up biologically relevant ions from solution and injecting more hydrophobic ions into the active layer. Using poly[2,5-bis(3-tetradecylthiophen-2-yl) thieno[3,2-b]thiophene] as the active layer and a blend of an ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, and poly(vinylidene fluoride-co-hexafluoropropylene) as the ion exchange gel, four orders of magnitude improvement in device transconductance and a 100-fold increase in kinetics are demonstrated. The ability of the ion-exchange-gel OECT to record biological signals by measuring the action potentials of a Venus flytrap is demonstrated. These results show the possibility of using interface engineering to open up a wider palette of organic semiconductors as OECTs that can be gated by aqueous solutions.

Bischak, Connor G.↗

Modifying Interface Solvation and Oxygen Reduction Electrocatalysis with Hydrophobic Species

Ionic liquid interlayers improve the oxygen reduction reaction (ORR) kinetics on bulk and nanostructured catalysts for both Pt and alloyed-Pt materials. Despite the demonstrated performance enhancement at the half-cell and membrane electrode assembly level, the mechanism of the improvement is not fully understood. In this work, we combine single-crystal experiments with microkinetic modeling to uncover the origin of the ORR kinetic improvement on Pt(111) in the presence of ionic liquids and hydrophobic cations. With the incorporation of a modified Frumkin isotherm, our model accurately simulates the disorder–order transition observed in hydroxyl and bisulfate adsorption on Pt(111) under acidic conditions. Voltametric analysis shows that ionic liquids impact solvation to break so-called scaling relations between the adsorption strength of OH ad and O ad , but these effects have little impact on ORR activity. Instead, destabilized OH ad reduces the overall hydroxyl (spectator) coverage, resulting in higher availability of active sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrophobicity of Cryogenic Fluids for Fuel Transfer in Space Applicaitons

Introduction Hydrophobicity is the tendency of a fluid to repel another material or fluid. Hydrophobiciy can be measured through the wetting angle of the fluid on the surface of the other material. The greater the wetting angle, the more hydrophobic the surface is against the fluid. Hydrophobicity properties can be caused by one of two means, either through physical properties or chemical properties [\citenum{NARBUTT2020121}]. Physical hydrophobicity due to the surface of a solid creating surface roughness/patterning, minimizing the contact area between the fluid and the surface. This can be observed throughout nature, such as the surface of lotus leaves or butterfly wings. This physical property can be induced on a variety of surfaces, namely through laser etching, allowing a surface to be finely lineated to imitate these natural surfaces while controlling quantity, depth, and patterns of the etching on the surface [\citenum{10.1063/1.4905616}]. Physical hydrophobicity is therefore dependent on several variables, including the surface that the fluid is on and properties of the fluid itself, such as density and surface tension, both of which are dependent on temperature and/or pressure. Chemical hydrophobicity [\citenum{MadeiraHydrophobocicicici}] is due to the inherent chemical properties of the materials being used. This is most commonly due to the molecular structures changing the polarity of the materials. Depending on a nonpolar material will repel a polar material, proving to be hydrophobic, conversely if the polarity of the materials is the same (polar – polar, nonpolar – nonpolar), they will attract each other. Cryogenics refers to the behavior of materials at very low temperatures (<\ang{-100} C) [\citenum{ZOHURI20181}]. In space applications many things are inherently cryogenic, therefore this is an important field. There has been little research in how hydrophobicity changes at cryogenic temperatures. Cryogenic fluids are commonly used as fuels for spacecraft, therefore, integrating a hydrophobic surface can increase the transfer rate of the fuel. To test this, several experiments were set up to determine the hydrophobic properties of cryogenic fluids, including nitrogen (LN2), argon (LAr), oxygen (LOx), hydrogen (LH2), and methane (CH4), at cryogenic temperatures. Etched Wafer Testing A silicon wafer cut from a crystal of silicon [100] was used to model the potential hydrophobicity of various cryogenic fluids. Silicon [100] references to the crystallographic orientation of the silicon crystals in the wafer. These wafers were then laser etched to create a surface that is more likely to be hydrophobic. To test the hydrophobicity of the wafers at cryogenic temperatures, the temperatures of the wafers must be reduced to the same temperature as the cryogenic fluid being used to prevent rapid boil-off. To achieve this a double-walled vacuum insulated glass chamber was utilized. The chamber is open, with a double-walled glass that can be placed in a vacuum to remove condensation from the outside to allow easier viewing of the experiment. Furthermore, the silicon wafer's temperature must be lowered to the temperature of LN2, as well as maintain the temperature throughout the experiment. To achieve this a piece of 6061 aluminum was used, creating a stand-off for the wafer and it would allow for the insulation of the temperature of the wafers. The container was then filled with LN2 and once the LN2 stabilized the vaporization and the levels of LN2 dropped under the height of the wafer, the wafer was then allowed to air dry. Once the wafer was dry from the LN2, drops of LN2 were placed on the surface of the wafer for observation. During the first trial, the LN2 that was dropped on the surface displayed nonhydrophobic behaviors, spreading out along the surface, with a minimal wetting angle (too small to be measured). This process was repeated for liquid argon. Further testing with other cryogenic liquids will require different testing apparatuses due to being more volatile. Furthermore, several papers [\citenum{voltvolt7}] have suggested that running a voltage can induce a hydrophobic effect throughout a surface, further testing will include a voltage (constant and oscillating) to determine if voltage influences inducing hydrophobicity at cryogenic temperatures. Chemical Testing Coating the interior walls of the fuel tanks and fuel lines can successfully create a hydrophobic surface. The inherent problem is finding a material that can be used to coat the surface, furthermore, at these temperatures, the coating will remain solid, which could pose issues in maintaining the hydrophobic properties. To test this water (polar) is hydrophobic against oils and fats (nonpolar), therefore the same experiment as the etched wafer testing was conducted to determine if the hydrophobic properties will persist as the nonpolar material remains solid and the polar material remains a fluid. The water remained hydrophobic, allowing testing can expand to the cryogenic fluids. However, another hurdle is faced in finding a chemically opposite material to the cryogenic fluids being tested. As many of the cryogenic fluids being tested are diatomic, they are inherently nonpolar, therefore, the material used for the hydrophobic coating must be polar. Polar greases and lubricants are difficult to come by, however, lithium stearate, appears to be a potential candidate for creating a coated hydrophobic surface for cryogenic fluids at cryogenic temperatures.

Cryogenics↗

Surfactant Facilitated Spreading of Aqueous Drops on Hydrophobic Surfaces

Microgravity technologies often require aqueous phases to spread over nonwetting hydrophobic solid/surfaces. At a hydrophobic surface, the air/hydrophobic solid tension is low, and the solid/aqueous tension is high. A large contact angle forms as the aqueous/air tension acts together with the solid/air tension to balance the large solid/aqueous tension. The aqueous phase, instead of spreading, is held in a meniscus by the large angle. Surfactants facilitate the wetting of water on hydrophobic surfaces by adsorbing on the water/air and hydrophobic solid/water interfaces and lowering the surface tensions of these interfaces. The tension reductions decrease the contact angle, which increases the equilibrium wetted area. Hydrocarbon surfactants (i.e. amphiphiles with a hydrophobic chain of methylene groups attached to a large polar group to give aqueous solubility) do not reduce significantly the contact angles of the very hydrophobic surfaces such as parafilm or polyethylene. Trisiloxane surfactants (amphiphiles with a hydrophobe consisting of methyl groups linked to a trisiloxane backbone in the form of a disk ((CH3)3-Si-O-Si-O-Si(CH3)3)) and an extended ethoxylate (-(OCH2CH2)n-) polar group in the form of a chain with seven or eight units) can significantly reduce the contact angle of water on a very hydrophobic surface and cause rapid and complete (or nearly complete) spreading (lermed superspreading). The overall goal of the research described in this proposal is to establish and verify a theory for how trisiloxanes cause superspreading, and then use this knowledge as a guide to developing more general hydrocarbon based surfactant systems which superspread and can be used in microgravity. We propose that the trisiloxane surfactants superspread when the siloxane adsorbs, the hydrophobic disk parts of the molecule adsorb onto the surface removing the surface water. Since the cross sectional area of the disk is larger than that of the extended ethoxylate chain, the disks can form a space filling mat on the surface which removes a significant amount of the surface water. The water adjacent to the hydrophobic solid surface is of high energy due to incomplete hydrogen bonding; its removal significantly lowers the tension and reduces the contact angle. Hydrocarbon surfactants cannot remove as much surface water because their large polar groups prevent the chains from cohering lengthwise. In our report last year we presented a poster describing the preparation of model very hydrophobic surfaces which are homogeneous and atomically smooth using self assembled monolayers of octadecyl trichlorosilane (OTS). In this poster we will use these surfaces as test substrates in developing hydrocarbon based surfactant systems which superspread. We studied a binary hydrocarbon surfactant systems consisting of a very soluble large polar group polyethylene oxide surfactant (C12E6 (CH3(CH2)11(OCH2CH2)6OH) and a long chain alcohol dodecanol. By mixing the alcohol with this soluble surfactant we have found that the contact angle of the mixed system on our test hydrophobic surfaces is very low. We hypothesize that the alcohol fills in the gaps between adjacent adsorbed chains of the large polar group surfactant. This filling in removes the surface water and effects the decrease in contact angle. We confirm this hypothesis by demonstrating that at the air/water interface the mixed layer forms condensed phases while the soluble large polar group surfactant by itself does not. We present drop impact experiments which demonstrate that the dodecanol/C12E6 mixture is effective in causing impacting drops to spread on the very hydrophobic model OTS surfaces.

Kumar, Nitin↗

Surfactant Facilitated Spreading of Aqueous Drops on Hydrophobic Surfaces

Microgravity technologies often require aqueous phases to spread over nonwetting hydrophobic solid surfaces. Surfactants facilitate the wetting of water on hydrophobic surfaces by adsorbing on the water/air and hydrophobic solid/water interfaces and lowering the surface tensions of these interfaces. The tension reductions decrease the contact angle, which increases the equilibrium wetted area. Hydrocarbon surfactants; (i.e., amphiphiles with a hydrophobic moiety consisting of an extended chain of (aliphatic) methylene -CH2- groups attached to a large polar group to give aqueous solubility) are capable of reducing the contact angles on surfaces which are not very hydrophobic, but do not reduce significantly the contact angles of the very hydrophobic surfaces such as parafilm, polyethylene or self assembled monolayers. Trisiloxane surfactants (amphiphiles with a hydrophobe consisting of methyl groups linked to a trisiloxane backbone in the form of a disk ((CH3)3-Si-O-Si-O-Si(CH3)3) and an extended ethoxylate (-(OCH2CH2)a-) polar group in the form of a chain with four or eight units) can significantly reduce the contact angle of water on a very hydrophobic surface and cause rapid and complete (or nearly complete) spreading (termed superspreading). The overall goal of the research described in this proposal is to establish and verify a theory for how trisiloxanes cause superspreading, and then use this knowledge as a guide to developing more general hydrocarbon based surfactant systems which superspread. We propose that the trisiloxane surfactants superspread because their structure allows them to strongly lower the high hydrophobic solid/aqueous tension when they adsorb to the solid surface. When the siloxane adsorbs, the hydrophobic disk parts of the molecule adsorb onto the surface removing the surface water. Since the cross-sectional area of the disk is larger than that of the extended ethoxylate chain, the disks can form a space-filling mat on the surface which removes a significant amount of the surface water. In this presentation, we report the results of measurements of the molecular packing and rates of kinetic exchange of the trisiloxane surfactants at the air/water interface in order to confirm our picture of trisiloxane packing, and provide additional insight into the superspreading process. We used the pendant bubble technique as a Langmuir trough to measure the trisiloxane equation of state which relates the tension to the surface concentration. From these measurements we obtain accurate values for the maximum packing density. We find that trisiloxanes with 4 and 8 ethoxylate groups have the same maximum packing concentration, indicating that the maximum packing is controlled by the cross section of the head group. For trisiloxanes with larger than eight ethoxylates, the maximum packing increases with ethoxylate number, indicating that the disposition of the ethoxylate chain (i.e., its effective size) is controlling. This supports our picture of superspreading: The superspreading ability of trisiloxanes decreases considerably for trisiloxanes with larger than eight ethoxylates; the packing measurements indicate that for the higher ethoxylate number trisiloxanes, the compact nonpolar head groups are pushed apart by the ethoxylate chain. They leave spaces of surface water on adsorption and do not lower the solid tension as much as their lower chain analogues. Finally the report measurements of the dynamic tension reduction accompanying the adsorption of trisiloxanes onto an initially clean interface using the pendant bubble technique, and we obtain from these relaxations, the equation of state and a mass transfer model, the rate constants for kinetic exchange. We find that the rate constants for desorption of trisiloxanes are generally much slower than for analogous aliphatic polyethoxylate surfactants with identical ethoxylate chain lengths. When an aqueous drop of a superspreader solution is placed on a hydrophobic surface and begins to spread, the lower desorption rates allows the tension at the drop center to remain reduced relative to the tension of the expanding periphery, thus strengthening Marangoni forces which can assist the spreading. Marangoni forces can be especially significant in the case of superspreaders because their maximum equilibrium reduction in tension is several dynes/cm lower than for aliphatic surfactants.

Kumar, Nitin↗

Hydrophobic pockets built in polymer micelles enhance the reactivity of Cu 2+ ions

We report the hydrophobicity-enhanced reactivity of Cu2+ ions as an ester hydrolase. Using a dipicolylamine (DPA) containing reversible addition–fragmentation chain transfer agent, the synthetic sequence, either hydrophobic or hydrophilic first in amphiphilic block copolymers of polystyrene-block-poly(N'N-dimethylacrylamide) (PS-b-PDMA), was varied to control the location of the binding motif, DPA, in the hydrophobic core or on the hydrated corona of polymer micelles. The hydrophobicity of Cu 2+ sites showed a significant impact (as large as 60 times more activity) on their catalytic efficiency towards ester hydrolase. With two different kinetic modes, including Michaelis–Menten and the reverse saturation kinetics models, the binding constant Kb of the substrates to Cu 2+ sites were quantitatively analyzed and we demonstrate that hydrophobicity favors the binding of the substrates to Cu2+ sites at polymer micelles with smaller sizes, however, K b decays exponentially with micellar diameters. Despite the diffusion barrier, hydrophobicity shows a profound impact on the catalytic rate constant kc that measures the single conversion rate of bound substrates to products. There is a 16–20 times kinetic enhancement in the hydrolase activity, completely endowed by the hydrophobic microenvironment of Cu 2+ sites compared to micelles with similar sizes. Our results indicate how the hydrophobicity of Cu 2+ -containing micelles can impact the catalytic efficiency and potentially illustrate a promising way toward the design of bioinspired catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D RNA nanocage for encapsulation and shielding of hydrophobic biomolecules to improve the in vivo biodistribution

Ribonucleic acid (RNA) nanotechnology platforms have the potential of harboring therapeutics for in vivo delivery in disease treatment. However, the nonspecific interaction between the harbored hydrophobic drugs and cells or other components before reaching the diseased site has been an obstacle in drug delivery. In this work, we report an encapsulation strategy to prevent such nonspecific hydrophobic interactions in vitro and in vivo based on a self-assembled three-dimensional (3D) RNA nanocage. By placing an RNA three-way junction (3WJ) in the cavity of the nanocage, the conjugated hydrophobic molecules were specifically positioned within the nanocage, preventing their exposure to the biological environment. The assembly of the nanocages was characterized by native polyacrylamide gel electrophoresis (PAGE), atomic force microscopy (AFM), and cryogenic electron microscopy (cryo-EM) imaging. The stealth effect of the nanocage for hydrophobic molecules in vitro was evaluated by gel electrophoresis, flow cytometry, and confocal microscopy. The in vivo sheathing effect of the nanocage for hydrophobic molecules was assessed by biodistribution profiling in mice. The RNA nanocages with hydrophobic biomolecules underwent faster clearance in liver and spleen in comparison to their counterparts. Therefore, this encapsulation strategy holds promise for in vivo delivery of hydrophobic drugs for disease treatment.

59 BASIC BIOLOGICAL SCIENCES↗

Performance of hydrophobic physical solvents for pre-combustion CO 2 capture at a pilot scale coal gasification facility

Here, in this paper, we present the first pilot plant data for hydrophobic physical solvents for CO 2 and H 2 S removal from coal-derived H 2 -rich syngas. Four physical solvents were tested under pre-combustion CO 2 capture conditions at bench scale and pilot plant scale: one baseline hydrophilic solvent and three hydrophobic solvents. The solvents were: (1) polyethylene-glycol-dimethyl ether (PEGDME), a hydrophilic solvent analog for the commercial process Selexol, (2) tributyl- phosphate (TBP), a commercially available hydrophobic solvent, (3) polyethylene glycol-poly(dimethylsiloxane) (PEG-PDMS-3), and (4) diethyl sebacate (CASSH-1), a novel, computationally screened hydrophobic solvent developed by the National Energy Technology Laboratory (NETL). All solvents were studied under pure gas (CO 2 /N 2 /H 2 /CH 4 ) equilibrium conditions at NETL followed by pilot plant testing with syngas at the University of North Dakota Energy & Environmental Research Center (UND EERC). Long term performance of CASSH-1 and PEDGME was then assessed with results compared to process simulation predictions. Within experimental uncertainties, all solvents showed comparable CO 2 absorption performance at above room temperature operation while the hydrophobic solvents had limited water uptake and low vapor pressure, which alleviates concerns related to corrosion, water absorption, and solvent loss to evaporation. These results indicate low viscosity, low vapor pressure hydrophobic solvents are a promising option for lower cost CO 2 capture from high pressure syngas applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aging of Limestones and Silane–Siloxane-Based Protective Hydrophobics: The Impact of Heating–Cooling and Freeze–Thaw Cycles

Stones are traditionally used in construction and architectural applications as building elements due to their aesthetic and technical/structural performance. Like other environmental factors (rain, humidity, moisture, salt presence, biological activity, etc.), heating–cooling and freeze–thaw cycles significantly threaten the longevity of stone materials. Hence, considering the socio-economic and cultural value of stones, preventive actions such as hydrophobic coatings are applied to prevent or mitigate damage. The scope of this study is the performance assessment of limestones with different characteristics and the efficiency of various commercial silane/siloxane-based hydrophobic coatings when exposed to thermal variation and freeze–thaw. For that purpose, the standards EN 14066:2013 (determination of resistance to aging by thermal shock) and EN 12371:2010 (determination of frost resistance) were followed. Open porosity and static contact angles were estimated to assess the stone durability and water protection capabilities of the hydrophobics. Additionally, sound speed propagation velocity, quality of building material index, elastic modulus and flexural strength were measured to evaluate the variation of mechanical properties. Static contact angle revealed that the coatings maintained an efficient level of hydrophobicity even after thermal-shock and freeze–thaw weathering tests. The study also revealed a critical interaction between freeze–thaw cycles, hydrophobic coatings and structural integrity of the stones, mostly on more porous ones. When they are subjected to harsh environmental conditions, untreated porous limestones keep structural cohesion, allowing for the natural absorption and release of water during freezing and thawing. On the contrary, when limestones are treated, the hydrophobic coatings can moderately obstruct the water release due to the partial saturation of the porous framework by the products. It also probably resulted from the different mechanical behavior between the inner matrix and layer of stone coated, resulting in a premature breakout and mechanical damage of the stone.

Lisci, Carla (ORCID:000000032179130X)↗

How hydrophobicity, side chains, and salt affect the dimensions of disordered proteins

Abstract Despite the generally accepted role of the hydrophobic effect as the driving force for folding, many intrinsically disordered proteins (IDPs), including those with hydrophobic content typical of foldable proteins, behave nearly as self‐avoiding random walks (SARWs) under physiological conditions. Here, we tested how temperature and ionic conditions influence the dimensions of the N‐terminal domain of pertactin (PNt), an IDP with an amino acid composition typical of folded proteins. While PNt contracts somewhat with temperature, it nevertheless remains expanded over 10–58°C, with a Flory exponent, ν , >0.50. Both low and high ionic strength also produce contraction in PNt, but this contraction is mitigated by reducing charge segregation. With 46% glycine and low hydrophobicity, the reduced form of snow flea anti‐freeze protein (red‐sfAFP) is unaffected by temperature and ionic strength and persists as a near‐SARW, ν ~ 0.54, arguing that the thermal contraction of PNt is due to stronger interactions between hydrophobic side chains. Additionally, red‐sfAFP is a proxy for the polypeptide backbone, which has been thought to collapse in water. Increasing the glycine segregation in red‐sfAFP had minimal effect on ν . Water remained a good solvent even with 21 consecutive glycine residues ( ν > 0.5), and red‐sfAFP variants lacked stable backbone hydrogen bonds according to hydrogen exchange. Similarly, changing glycine segregation has little impact on ν in other glycine‐rich proteins. These findings underscore the generality that many disordered states can be expanded and unstructured, and that the hydrophobic effect alone is insufficient to drive significant chain collapse for typical protein sequences.

59 BASIC BIOLOGICAL SCIENCES↗

Molecular Dynamics Investigation of Nanoscale Hydrophobicity of Polymer Surfaces: What Makes Water Wet?

The wettability of a polymer surface–related to its hydrophobicity or tendency to repel water–can be crucial for determining its utility, such as for a coating or a purification membrane. While wettability is commonly associated with the macroscopic measurement of a contact angle between surface, water, and air, the molecular physics that underlie these macroscopic observations are not fully known, and anticipating relative behavior of different polymers is challenging. To address this gap in molecular-level understanding, we use molecular dynamics simulations to investigate and contrast interactions of water with six chemically distinct polymers: polytetrafluoroethylene, polyethylene, polyvinyl chloride, poly(methyl methacrylate), Nylon 66, and polyvinyl alcohol. We show that several prospective quantitative metrics for hydrophobicity agree well with experimental contact angles. Moreover, the behavior of water in proximity to these polymer surfaces can be distinguished with analysis of interfacial water dynamics, extent of hydrogen bonding, and molecular orientation–even when macroscopic measures of hydrophobicity are similar. The predominant factor dictating wettability is found to be the extent of hydrogen bonding between polymer and water, but the precise manifestation of hydrogen bonding and its impact on surface-water structure varies. In the absence of hydrogen bonding, other molecular interactions and polymer mechanics control hydrophobic ordering. Furthermore, these results provide new insights into how polymer chemistry specifically impacts water-polymer interactions and translates to surface hydrophobicity. Such factors may facilitate the design or processing of polymer surfaces to achieve targeted wetting behavior, and presented analyses can be useful in studying the interfacial physics of other systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Significant Differences in Solvation Thermodynamics of C1–C3 Oxygenates in Hydrophilic versus Hydrophobic Pores of a Hydrophilic Ti-FAU Zeolite Model

The rates of catalytic reactions have been observed to be dramatically different in zeolites, depending on if they are hydrophobic or hydrophilic. Hypotheses aimed at explaining this behavior have pointed to various solvent molecule and zeolite properties as having influence on entropy. Herein, the influence of various solvent and adsorbate properties on the solvation energies, entropies, and free energies of eleven C1-C3 oxygenates in hydrophobic and hydrophilic pores within a hydrophilic model of Ti-FAU zeolite are tested. The results indicate significant variation in the calculated solvation thermodynamics depending on the adsorbate type, as well as if it is bound within a hydrophobic or hydrophilic pore. Further, while solvation energies are related to solvent-adsorbate interactions, solvation entropies have multiple contributions, and these differ depending on if the adsorbate is in a hydrophobic or hydrophilic pore. Specifically, solvation entropies in hydrophobic pores are related to solvent structural properties, whereas solvation entropies in hydrophilic pores are related to adsorbate polarity. Here, the large range of results obtained from two different pores within one zeolite model with minimal unique adsorption sites suggests that solvation behavior in zeolites is complicated and that the phenomena that control observed performance depend on the zeolite, reaction, and solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗