Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Hubbard model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Engineering 2D Square Lattice Hubbard Models in 90° Twisted GeX/SnX (X =S, Se) Moiré Superlattices

Because of the large-period superlattices emerging in moiré two-dimensional (2D) materials, electronic states in such systems exhibit low energy flat bands that can be used to simulate strongly correlated physics in a highly tunable setup. While many investigations have thus far focused on moiré flat bands and emergent correlated electron physics in triangular, honeycomb, and quasi-one-dimensional lattices, tunable moiré realizations of square lattices subject to strong correlations remain elusive. Here, in this work, we propose a feasible scheme to construct moiré square lattice systems by twisting two or more layers of 2D materials in a rectangular lattice by 90°. We demonstrate the concept with twisted GeX/SnX (X =S, Se) moiré superlattices and calculate their electronic structures from first principles. We show that the lowest conduction flat band in these systems can be described by a square lattice Hubbard model with parameters which can be controlled by varying the choice of host materials, number of layers, and external electric fields. In particular, twisted double bilayer GeSe realizes a square lattice Hubbard model with strong frustration due to the next-nearest-neighbor hopping that could host unconventional superconductivity, in close analogy to the Hubbard model for copper-oxygen planes of cuprate high-temperature superconductors. The presented scheme uses 90° twisted 2D materials with rectangular unit cells as a promising platform for realizing the physical phenomena of square lattice Hubbard models, establishing a new route for studying its rich phase diagram of magnetism, charge order, and unconventional superconductivity in a highly tunable setting.

2-dimensional systems

Ferrimagnetism of ultracold fermions in a multiband Hubbard system

Strongly correlated materials feature multiple electronic orbitals, which are crucial to accurately understanding their many-body properties. In such multiband models, quantum interference can lead to flat energy bands with large degeneracy that gives rise to itinerant magnetic phases. Here, we report on signatures of a ferrimagnetic state realized in a Lieb lattice with ultracold fermions, characterized by antialigned magnetic moments with antiferromagnetic correlations, and concomitant with a finite spin polarization. The signatures remain robust when increasing repulsive interactions from the weakly interacting to the Heisenberg regime and emerge when continuously tuning the lattice unit cell from a square to a Lieb geometry. Our flexible approach paves the way toward exploring exotic phases, such as quantum spin liquids in kagome lattices and heavy fermion behavior in Kondo models.

Lebrat, Martin [Harvard Univ., Cambridge, MA (Unit

Entanglement Structure of Non-Gaussian States and How to Measure It

Rapidly growing capabilities of quantum simulators to probe quantum many-body phenomena require new methods to characterize increasingly complex states. Here, we present a protocol that constrains quantum states using experimentally measured correlation functions. This method enables measurement of a quantum state’s entanglement structure, opening a new route to study entanglement-related phenomena. Our approach extends Gaussian state parameterizations by systematically incorporating higher-order correlations. We show the protocol’s usefulness in conjunction with current and forthcoming experimental capabilities, focusing on weakly interacting fermions as a proof of concept. Here, the lowest nontrivial expansion quantitatively predicts early time thermalization dynamics, including signaling the onset of quantum chaos indicated by the entanglement Hamiltonian.

Fermi gases

Quantum control of Hubbard excitons

Quantum control of the many-body wavefunction is a central challenge in quantum materials research, as it could yield a precise control knob to manipulate emergent phenomena. Floquet engineering, the coherent dressing of quantum states with periodic non-resonant optical fields, has become an important strategy for quantum control. Most applications to solid-state systems have targeted weakly interacting or single-ion states, leaving the manipulation of many-body wavefunctions largely unexplored. Here, in this work, we use Floquet engineering to achieve quantum control of a strongly correlated Hubbard exciton in the one-dimensional Mott insulator Sr 2 CuO 3 . A nonresonant midinfrared optical field coherently dresses the exciton wavefunction, driving its rotation between bright and dark states. We use resonant third-harmonic generation to quantify ultrafast π/2 rotations on the Bloch sphere spanned by these exciton states. Our work advances the quest towards programmable control of correlated states and exciton-based quantum sensing.

36 MATERIALS SCIENCE

Healable Coatings as a Mechanism to Repair Leading Edge Erosion in Wind Energy

Wind turbine blades are highly engineered structures designed to face temperature extremes and high winds. However, erosion of the blade's leading edge and subsequent repair remains a significant and costly challenge for the wind energy industry. Repair of these leading edges can lead to large amounts of downtime for the turbine and significant operational inefficiencies. In this work, the strength of adhesion and healing ability of a commercially available vitrimer (Mallinda's VITRIMAX) was compared to that of a thermoplastic resin, which has previously been demonstrated in wind energy applications (Arkema's Elium) to evaluate their efficacy as surface coatings for wind turbine blades, particularly their leading edges. Vitrimers are a class of inherently reprocessable thermosets, and it was theorized that vitrimer-based leading edge coatings could enable more robust and efficient wind turbine blades with decreased operational downtime and safer maintenance practices. It was found that the VITRIMAX adhered better to the wind blades' surfaces than both the manufacturer's paint and Elium, with increases in pull-off strength of adhesion ranging from 24% to 83% above that of the original paint. Furthermore, the VITRIMAX adhered strongly to the underlying composite of each blade with strength of adhesion values increasing in ranges from 42% to 97% above that of the original paint. Finally, the vitrimer coating showed an 88% decrease in surface roughness compared to end-of-life blade materials, and initial healing demonstrations in which coatings were manually scratched and subsequently healed exhibited an ~84.5% decrease in scratch depths.

Hubbard, Amber [ORNL]

Tritium Betavoltaic Powered Sensor Platforms: Power Augmentation with Scintillating Particles

Betavoltaics (BV) are long-life power sources that typically convert beta particle radiation into electricity. Largely, the radioactive decays within the source go unharvested by the device. This work seeks to augment the power generation of BV devices by integration of scintillating particles within the radiative getter to convert beta emission which would otherwise not leave the getter into usable light for power generation. Silica-covered barium fluoride scintillating particles were integrated into a tritiated water getter. Power generation was increased from 100s of nW to µW levels with the addition of 0.2 wt. % particles into the getter. Nanowatt-scale sensor platforms were demonstrated with the µW BV devices and the maximum possible lifetime of such platforms was estimated. As this technique enables higher power density BV devices from conventional Si semiconductors (compared to wider bandgap BVs), the further implementation may lower the barrier-to-deployment of these long-life power/sensor platforms.

42 ENGINEERING

Hybrid Bio-Based Composites: Enabling Cellulose Nanofiber (CNF) Incorporation into Composites via Macroscale Natural Fiber Carriers

Cellulose nanofibers (CNFs) have significant potential in composites as additives to improve mechanical properties, melt rheology, and more. However, agglomeration of CNFs is a key challenge in composite melt processing as obtaining nano-level dispersion of CNFs often requires cost- and energy-intensive processes (e.g., solvent exchange or freeze drying) due to the strong hornification tendencies of CNF. Herein, we avoid these challenges by using a natural fiber carrier method to integrate CNF into thermoplastic composites. Fibers are co-dried to create a hybrid fiber feedstock for compounding in which natural fibers are decorated with dispersed nanofibers. The hybridized fibers result in up to a 24% increase in tensile strength and up to a 35% increase in Young’s modulus compared to composites only containing natural fibers. The lignocellulosic nanofibers are found to outperform their purely cellulosic counterpart, which is theorized to be due to either an increased propensity for fibrillation of the lignocellulosic fibers or the increased hydrophobicity of the fibers due to the presence of lignin. Surface analysis of fiber feedstocks, via streaming potential measurements and dynamic light scattering (DLS), confirmed a significant change in the feedstock hydrophobicity before and after hybridization. While mild additions of CNF (1 wt.% on the macroscale fiber) do not impact the composite melt viscosity, the viscosity is found to increase at higher CNF loadings (5 wt.% on the macroscale fiber), indicating its utility as a rheology modifier. Lastly, use of these materials as novel feedstocks for medium-scale additive manufacturing in high-fidelity part production was demonstrated.

bio-based

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Data-Driven Method for Modeling Creep-Fatigue Stress- Strain Behavior Using Neural ODEs

In this paper, we introduce a data-driven machine learning approach for modeling one-dimensional stress–strain behavior under cyclic loading, utilizing experimental data from the nickel-based Alloy 617. The study employs uniaxial creep–fatigue test data acquired under various loading histories and compares two distinct neural network-based ODE models. The first model, known as the black-box model, comprehensively describes the strain–stress relationship using a Neural ODE equation. To interpret this black-box model, we apply the Sparse Identification of Nonlinear Dynamical Systems (SINDy) technique, transforming the black-box model into an equation-based model using symbolic regression. The second model, the Neural flow rule model, incorporates Hooke’s Law for the linear elastic component, with the nonlinear part characterized by a Neural ODE. Both models are trained with experimental data to accurately reflect the observed stress–strain behavior. We conduct a detailed comparison with the standard Chaboche model, which includes three back stresses. Our results demonstrate that the neural network-based ODE models precisely capture the experimental creep–fatigue mechanical behavior, exceeding the standard Chaboche model’s accuracy. Furthermore, an interpretable model derived from the black-box neural ODE model through symbolic regression achieves accuracy comparable to the Chaboche model, enhancing its interpretability. The results highlight the potential of neural network-based ODE models to depict complex creep–fatigue behavior, eliminating the necessity for experts to define a specific, material-focused model form.

creep-fatigue