Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High Throughput, High Precision Hot Testing Tool for HBLED Wafer Level Testing

The Socrates research effort developed an in depth understanding and demonstrated in a prototype tool new precise methods for teh characterization of color characteristics and flux from individual LEDs for the production of uniform quality lighting. This effort was focused on improving the color quality and consistency of solid state lighting and potentially reducing characterization costs for all LED product types. The patented laser hot testing method was demonstrated to be far more accurate than all current state of the art color and flux characterization methods in use by the solid state lighting industry today. A seperately patented LED grouping method (statistical binning) was demonstrated to be a useful approach to improving utilization of entire lots of large color and flux distributions of manufactured LEDs for high quality color solid-state lighting. At the conclusion of the research in late 2015 the solid-state lighting industry was however generally satisfied with its existing production methods for high quality color products for the small segment of customers that demand it, albeit with added costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

System and method for rapid, high throughput, high pressure synthesis of materials from a liquid precursor

The present disclosure relates to a system and method for synthesis of condensed, nano-carbon materials to create nanoparticles. In one embodiment the system may have a source of liquid precursor, a flow control element and a shock wave generating subsystem. The flow control element is in communication with the source of the liquid precursor and creates a jet of liquid precursor. The shock wave generating subsystem drives a shock wave through at least a substantial portion of a thickness of the jet of liquid precursor to sufficiently compress the jet of liquid precursor, and to increase a pressure and a temperature of the jet of liquid precursor, to create solid state nanoparticles.

Armstrong, Mike↗

System and method for rapid, high throughput, high pressure synthesis of materials from a liquid precursor

The present disclosure relates to a system and method for synthesis of condensed nano-materials to at least one of create nanoparticles or modify existing nanoparticles. In one embodiment the system may have a source of liquid precursor, with the liquid precursor including a compound therein. A flow control element and a compression wave generating subsystem are also included. The flow control element is in communication with the source of the liquid precursor and creates a jet of liquid precursor. The compression wave generating subsystem drives a compression wave through at least a substantial portion of a thickness of the jet of liquid precursor to sufficiently compress the jet of liquid precursor, and to increase pressure and temperature of the jet of liquid precursor, to at least one of create nanoparticles or modify existing nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Two-dimensional material based layer transfer (2DLT) for low-cost, high-throughput, high-efficiency solar cells

The objective of this project is to develop two-dimensional material-based layer transfer (2DLT) for high-efficiency, low-cost III-V solar cells. More specifically, in short term, the team will develop 2DLT for cost-cost, high-throughput GaAs single-junction solar cells. The team will develop ultraclean high yield graphene transfer on GaAs and optimize the remote homoepitaxy process to obtain dislocation-free single-crystalline GaAs on graphene whose crystalline quality is identical to that of the GaAs wafer [1,2]. The team will develop the 2DLT process for a solar cell with highest achievable efficiency. The team will also strive to target GaAs solar cells with efficiency of 25~29% before and after the transfer, and reuse the substrate multiple times without CMP by damage-free transfer process enabled by 2DLT. Our team is partnered with industrial collaborators to obtain World record efficiency of flexible GaAs solar cells. Once the concept is fully realized for the GaAs solar cells, the team will expand the concept for multiple-junction solar cell targeting 35% efficiency with the 2DLT process in other projects.

14 SOLAR ENERGY↗

Management of metadata and automation for mail-in measurements with the APS 11-BM high throughput, high-resolution synchrotron powder diffractometer.

A high-resolution and high-throughput synchrotron powder diffractometer has been automated for use with samples that are mailed in by Advanced Photon Source users. Implementation of a relational database with web interfaces for both outside users and beamline staff, which is integrated into the facility-wide proposal and safety system, allows all aspects of beamline management to be integrated. This system permits users to request kits for mounting samples, to provide sample safety information, to obtain their collected data and to provide usage information upon project completion in a quick and simple manner. Beamline staff use a separate interface to note receipt of samples, schedule and collect diffraction data, post-process and quality-check data, and dispose of samples. The design of the software and database are discussed in detail.

43 PARTICLE ACCELERATORS↗

GROMACS 4.5: A high-throughput and highly parallel open source molecular simulation toolkit

In this study, molecular simulation has historically been a low-throughput technique, but faster computers and increasing amounts of genomic and structural data are changing this by enabling large-scale automated simulation of, for instance, many conformers or mutants of biomolecules with or without a range of ligands. At the same time, advances in performance and scaling now make it possible to model complex biomolecular interaction and function in a manner directly testable by experiment. These applications share a need for fast and efficient software that can be deployed on massive scale in clusters, web servers, distributed computing or cloud resources. As a result, we present a range of new simulation algorithms and features developed during the past 4 years, leading up to the GROMACS 4.5 software package. The software now automatically handles wide classes of biomolecules, such as proteins, nucleic acids and lipids, and comes with all commonly used force fields for these molecules built-in. GROMACS supports several implicit solvent models, as well as new free-energy algorithms, and the software now uses multithreading for efficient parallelization even on low-end systems, including windows-based workstations. Together with hand-tuned assembly kernels and state-of-the-art parallelization, this provides extremely high performance and cost efficiency for high-throughput as well as massively parallel simulations.

97 MATHEMATICS AND COMPUTING↗

Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers would ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode, also known as multiple reaction monitoring (MRM), is capable of quantitatively measuring hundreds of candidate protein biomarkers from a relevant clinical sample in a single analysis. The specificity, reproducibility and sensitivity could be as good as ELISA. Furthermore, SRM MS can also quantify protein isoforms and post-translational modifications, for which traditional antibody-based immunoassays often don’t exist.

Environmental Molecular Sciences Laboratory↗

Development and operation of a high-throughput accurate-wavelength lens-based spectrometer

A high-throughput spectrometer for the 400–820 nm wavelength range has been developed for charge exchange recombination spectroscopy or general spectroscopy. A large 2160 mm{sup −1} grating is matched with fast f/1.8 200 mm lenses, which provide stigmatic imaging. A precision optical encoder measures the grating angle with an accuracy ≤0.075 arc sec. A high quantum efficiency low-etaloning CCD detector allows operation at longer wavelengths. A patch panel allows input fibers to interface with interchangeable fiber holders that attach to a kinematic mount at the entrance slit. Computer-controlled hardware allows automated control of wavelength, timing, f-number, automated data collection, and wavelength calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustic transfer of protein crystals from agarose pedestals to micromeshes for high-throughput screening

An acoustic high-throughput screening method is described for harvesting protein crystals and combining the protein crystals with chemicals such as a fragment library. Acoustic droplet ejection (ADE) is an emerging technology with broad applications in serial crystallography such as growing, improving and manipulating protein crystals. One application of this technology is to gently transfer crystals onto MiTeGen micromeshes with minimal solvent. Once mounted on a micromesh, each crystal can be combined with different chemicals such as crystal-improving additives or a fragment library. Acoustic crystal mounting is fast (2.33 transfers s{sup −1}) and all transfers occur in a sealed environment that is in vapor equilibrium with the mother liquor. Here, a system is presented to retain crystals near the ejection point and away from the inaccessible dead volume at the bottom of the well by placing the crystals on a concave agarose pedestal (CAP) with the same chemical composition as the crystal mother liquor. The bowl-shaped CAP is impenetrable to crystals. Consequently, gravity will gently move the crystals into the optimal location for acoustic ejection. It is demonstrated that an agarose pedestal of this type is compatible with most commercially available crystallization conditions and that protein crystals are readily transferred from the agarose pedestal onto micromeshes with no loss in diffraction quality. It is also shown that crystals can be grown directly on CAPs, which avoids the need to transfer the crystals from the hanging drop to a CAP. This technology has been used to combine thermolysin and lysozyme crystals with an assortment of anomalously scattering heavy atoms. The results point towards a fast nanolitre method for crystal mounting and high-throughput screening.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A reactor for high-throughput high-pressure nuclear magnetic resonance spectroscopy

The design of a reactor for operando nuclear magnetic resonance (NMR) monitoring of high-pressure gas-liquid reactions is described. The Wisconsin High Pressure NMR Reactor (WiHP-NMRR) design comprises four modules: a sapphire NMR tube with titanium tube holder rated for pressures as high as 1000 psig (68 atm) and temperatures ranging from −90 to 90 °C, a gas circulation system that maintains equilibrium concentrations of dissolved gases during gas-consuming or gas-releasing reactions, a liquid injection apparatus that is capable of adding measured amounts of solutions to the reactor under high pressure conditions, and a rapid wash system that enables the reactor to be cleaned without removal from the NMR instrument. The WiHP-NMRR is compatible with commercial 10 mm NMR probes. Reactions performed in the WiHP-NMRR yield high quality, information-rich, and multinuclear NMR data over the entire reaction time course with rapid experimental turnaround.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holistic digital gamma-ray spectroscopy methods and instrumentation for high-throughput high-resolution applications

Method of real-time adaptive digital pulse signal processing for high count rate gamma-ray spectroscopy applications includes receiving a preamplifier signal at a pulse deconvolver, the preamplifier signal including resolution deterioration resulting from pulse pile-up. The method further includes generating a deconvoluted signal, by the pulse deconvolver, from the preamplifier signal, the deconvoluted signal having less resolution deterioration as compared to the received preamplifier signal. The method furthermore includes shaping of the deconvoluted signal by a trapezoid filter, the shaping comprising adjusting a shaping parameter of the trapezoid filter for an incoming signal based on a time separation from a subsequent incoming signal.

Hawari, Ayman I.↗

HTESP (High-throughput electronic structure package): A package for high-throughput ab initio calculations

High-throughput ab initio calculations are the indispensable parts of data-driven discovery of new materials with desirable properties, as reflected in the establishment of several online material databases. The accumulation of extensive theoretical data through computations enables data-driven discovery by constructing machine learning and artificial intelligence models to predict novel compounds and forecast their properties. Efficient usage and extraction of data from these existing online material databases can accelerate the next stage materials discovery that targets different and more advanced properties, such as electron–phonon coupling for phonon-mediated superconductivity. However, extracting data from these databases, generating tailored input files for different ab initio calculations, performing such calculations, and analyzing new results can be demanding tasks. Here, in this work, we introduce a software package named “HTESP” (High-Throughput Electronic Structure Package) written in Python and Bash languages, which automates the entire workflow including data extraction, input file generation, calculation submission, result collection and plotting. Our HTESP will help speed up future computational materials discovery processes.

36 MATERIALS SCIENCE↗

High-throughput cancer hypothesis testing with an integrated PhysiCell-EMEWS workflow

BackgroundCancer is a complex, multiscale dynamical system, with interactions between tumor cells and non-cancerous host systems. Therapies act on this combined cancer-host system, sometimes with unexpected results. Systematic investigation of mechanistic computational models can augment traditional laboratory and clinical studies, helping identify the factors driving a treatment's success or failure. However, given the uncertainties regarding the underlying biology, these multiscale computational models can take many potential forms, in addition to encompassing high-dimensional parameter spaces. Therefore, the exploration of these models is computationally challenging. We propose that integrating two existing technologiesone to aid the construction of multiscale agent-based models, the other developed to enhance model exploration and optimizationcan provide a computational means for high-throughput hypothesis testing, and eventually, optimization.ResultsIn this paper, we introduce a high throughput computing (HTC) framework that integrates a mechanistic 3-D multicellular simulator (PhysiCell) with an extreme-scale model exploration platform (EMEWS) to investigate high-dimensional parameter spaces. We show early results in applying PhysiCell-EMEWS to 3-D cancer immunotherapy and show insights on therapeutic failure. We describe a generalized PhysiCell-EMEWS workflow for high-throughput cancer hypothesis testing, where hundreds or thousands of mechanistic simulations are compared against data-driven error metrics to perform hypothesis optimization.ConclusionsWhile key notational and computational challenges remain, mechanistic agent-based models and high-throughput model exploration environments can be combined to systematically and rapidly explore key problems in cancer. These high-throughput computational experiments can improve our understanding of the underlying biology, drive future experiments, and ultimately inform clinical practice.

Agent-based model↗

A high-throughput de novo sequencing approach for shotgun proteomics using high-resolution tandem mass spectrometry

High-resolution tandem mass spectra can now readily be acquired with hybrid instruments, such as LTQ-Orbitrap and LTQ-FT, in high-throughput shotgun proteomics workflows. In this study, a new de novo sequencing algorithm, Vonode, has been developed specifically for such high-resolution tandem mass spectra. To fully exploit the high mass accuracy, sparse noise, and low background of these spectra, a unique scoring system is used to evaluate sequence tags based mainly on mass accuracy information of fragment ions. Consensus sequence tags were inferred for 11,422 spectra with an average peptide length of 5.5 residues from a total of 40,297 input spectra acquired in a 24-hour proteomics measurement of Rhodopseudomonas palustris. The accuracy of inferred consensus sequence tags was 84%. The performance of Vonode was shown to be superior to the PepNovo v2.0 algorithm, especially in term of the number of de novo sequenced spectra.

59 BASIC BIOLOGICAL SCIENCES↗