Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Temperature Test Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of an Improved RELAP5-3D Model for the High Temperature Test Facility

High-temperature gas-cooled reactors (HTGRs) are rapidly approaching deployment. Confidence in transient analysis of these systems for design, optimization, and licensing calculations requires modeling and simulation tools that have been validated against data relevant to HTGR conditions. The High Temperature Test Facility (HTTF) is an integral effects thermal hydraulics test facility for prismatic HTGRs. In spring and summer of 2019, HTTF was used for a series of experiments that now serve as the basis for the OECD/NEA Thermal Hydraulic Code Validation Benchmark for High Temperature Gas-Cooled Reactors using HTTF Data (HTGR T/H Benchmark). This benchmark contains problems for systems code, computational fluid dynamics (CFD), and coupled systems code/CFD modeling representing lower plenum mixing and both the depressurized and pressurized conduction cooldown (DCC and PCC respectively) transients. Benchmark problems include exercises for code-to-code and code-to-data comparisons as well as an exercise for error scaling between HTTF and the Modular High Temperature Gas-Cooled Reactor, which serves as the basis for the HTTF design. Previous analysis as part of the HTGR T/H benchmark used a RELAP5-3D model developed at Idaho National Laboratory (INL) and demonstrated an ability to reproduce trends in the measured data but difficulties reproducing experimental values within their uncertainty. These difficulties were largely attributed to assumptions made during the development of the initial RELAP5-3D model, which predated the HTTF experiments. A significant cause of difficulty reproducing the measured temperatures may be the radial nodalization of the previous RELAP5-3D model. The new model provides a finer nodalization to assess the impact of radial nodalization and allows for asymmetric heating within the core, which was a feature of multiple HTTF experiments. In this paper, we present the new RELAP5-3D model of HTTF. In addition to describing the new model, this paper compares the new and old models and provides results for a full-power steady state, a DCC, and a PCC in HTTF. These analyses are based on the code-to-code comparison exercises for the DCC and PCC problems of the HTGR T/H benchmark. We present the results of these exercises from the new model and compare them to the results of the old model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of an Improved RELAP5-3D Model for the High Temperature Test Facility

High-temperature gas-cooled reactors (HTGRs) are rapidly approaching deployment. Confidence in transient analysis of these systems requires modeling and simulation tools that have been validated against data relevant to HTGR conditions. The High Temperature Test Facility (HTTF) is an integral effects thermal hydraulics test facility for prismatic HTGRs. In spring and summer of 2019, HTTF was used for a series of experiments that now serve as the basis for the Organization of Economic Cooperation and Development / Nuclear Energy Agency Thermal Hydraulic Code Validation Benchmark for High Temperature Gas-Cooled Reactors using HTTF Data (HTGR T/H Benchmark). Previous analyses as part of the HTGR T/H benchmark used a RELAP5-3D model developed at Idaho National Laboratory (INL) and demonstrated an ability to reproduce trends in the measured data but difficulties reproducing experimental values within their uncertainty. These difficulties were largely attributed to assumptions made during the development of the initial RELAP5-3D model, which predated the HTTF experiments. A significant cause of difficulty reproducing the measured temperatures may be the radial nodalization of the previous RELAP5-3D model. In this paper, we present a new RELAP5-3D model of HTTF with finer radial nodalization built to assess the impact of radial heat transfer. We describe the new model and compare it against the old one at full-power steady state and for the pressurized conduction cooldown (PCC) transient. These analyses are based on the code-to-code comparison exercise for the PCC problem of the HTGR T/H benchmark. We compare maximum block temperature as the primary figure of merit and include discussion on intracore natural circulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of the High Temperature Test Facility Using RELAP-7

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is an electrically heated, helium cooled, experimental facility. The HTTF was modeled using RELAP-7 in both 1-D and 3-D for validation. Due to core symmetry, 1/6th of the HTTF core was modeled in 3-D using the coupled heat conduction and forced convection capabilities of RELAP-7. This served as a validation case for RELAP-7 and its capabilities to model advanced nuclear technologies such as high temperature gas-cooled reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of Oregon State University High Temperature Test Facility Experiments Using Pronghorn

The OSU High Temperature Test Facility is a quarter-scale diameter, 1/64 scale volume test facility meant to replicate thermophysical phenomena in the prototypical General Atomics Modular High Temperature Gas Reactor. Tests pertaining to conduction cooldown events were performed from 2016-2019, providing a large database by which computational methods that are applicable to different length scales can be validated. One of these codes is Pronghorn, which is a coarse-meshed, porous-based subchannel thermal hydraulics code based on the MOOSE application, with the intention of better capturing the physics of both conduction and convection heat transfer within the OSU HTTF core. The goal of this summer project is to develop the framework by which Pronghorn can perform validation exercises of the HTTF core for benchmarking, by generating a mesh appropriate to the geometry of the HTTF core, developing input decks that accurately capture the initial and boundary conditions, materials, and relevant equations to the physics seen in the HTTF core, and using a postprocessor to compare simulation results to various experimental data. While validation of codes is a multi-year project, a mesh has been generated and tested in Pronghorn that meets mass conservation and basic heat transfer principles. The next step is to accurate depict the fluid inlet and outlet boundary conditions, which will be performed using computational fluid dynamics software.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High–Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next–generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds–averaged Navier–Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

97 MATHEMATICS AND COMPUTING↗

High Temperature Test Facility At Scale Testing, Validation, and Demonstration

Theses slides will be used to brief the Tribal DOE and Council Chairman for the project listed below. The High Temperature Test Facility (HTTF) is a demonstration-scale high temperature electrolysis (HTE) system that provides the ability to produce, process, store, and dispense electrolytically produced hydrogen. The system will be designed to accommodate electrolysis systems from various industry partners. The HTTF will be supplied up to 10 MW of power for electrolysis at 5 separate test article locations, each up to 2MW. The system will include post-processing and compression, storage, and capabilities to provide hydrogen for consumption by future end users. The HTTF will also provide the ability to test and demonstrate an HTE system in a configuration that would simulate the use of a nuclear generated steam supply for the high temperature heat source. The HTTF will be located at the Central Facilities Area (CFA) adjacent to CFA-686 on the INL site, 45 miles west of Idaho Falls.

08 HYDROGEN↗

Modeling of the High Temperature Test Facility PG-26 Transient Using RELAP-7

The High Temperature Test Facility (HTTF) is an electrically heated, helium cooled, experimental facility located at Oregon State University (OSU). Modeling of the HTTF PG-26 transient using a multi-app approach utilizing MOOSE and RELAP-7 was conducted. A 3-D model of the HTTF core, reflector, core barrel, and RPV was generated, and 3-D heat conduction throughout the structure was coupled to 1-D fluid flow results from RELAP-7. The model was able to accurately predict peak ceramic core temperatures experienced during the transient which helps validate the capability of RELAP-7 to model advanced gas-cooled nuclear reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Intracore Natural Circulation Study in the High Temperature Test Facility

The development of the Modular High-Temperature Gas-Cooled Reactor is a significant milestone in advanced nuclear reactor technology. One of the concerns for the reactor’s safe operation is the effects of a loss-of-flow accident (LOFA) where the coolant circulators are tripped, and forced coolant flow through the core is lost. Depending on the steam generator placement, loop or intracore natural circulation develops to help transfer heat from the core to the reactor cavity, cooling system. This paper investigates the fundamental physical phenomena associated with intracore coolant natural circulation flow in a one-sixth Computational Fluid Dynamics (CFD) model of the Oregon State University High Temperature Test Facility (OSU HTTF) following a loss-of-flow accident transient. This study employs conjugate heat transfer and steady-state flow along with an SST k-ω turbulence model to characterize the phenomenon of core channel-to-channel natural convection. Previous studies have revealed the importance of complex flow distribution in the inlet and outlet plenums with the potential to generate hot coolant jets. For this reason, complete upper and lower plenum volumes are included in the analyzed computational domain. CFD results also include parametric studies performed for a mesh sensitivity analysis, generated using the STAR-CCM+ software. The resulting channel axial velocities and flow directions support the test facility scaling analysis and similarity group distortions calculation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D validation studies based on the High Temperature Test facility

In the spring and summer of 2019, experiments were conducted at the High Temperature Test Facility (HTTF) that form the basis of an upcoming high-temperature gas-cooled reactor (HTGR) thermal hydraulics (T/H) benchmark. HTTF is an integral effects test facility for HTGR T/H modeling validation. This paper presents RELAP5-3D models of two of those experiments: PG-27, a pressurized conduction cooldown (PCC); and PG-29, a depressurized conduction cooldown (DCC). These models used the RELAP5-3D model of HTTF originally developed by Paul Bayless as a starting point. The sensitivity analysis and uncertainty quantification code, RAVEN was used to perform calibration studies for the steady-state portion of PG-27. Here we developed four PG-27 calibrations based on steady-state conditions. These calibrations all used an effective thermal conductivity equal to 36 % of the measured thermal conductivity, but they differed with respect to the frictional pressure drops and radial conduction models. These models all captured the trends in steady-state temperature distributions and transient temperature behavior well. All four calibrations show room for improvement in predicting the transient temperature rise. The smallest error in temperature rise during the transient was a 21 % underprediction, and the largest was a 48 % underprediction. The errors in transient temperature rise are largely a result of a mismatch in power density between the RELAP5-3D model and the experiment due to the location of active heater rods along the boundary between heat structures in the model. The best of these calibrations was applied to PG-29 to model the DCC. Once again, temperatures during the transient were underpredicted but trends in temperature were captured. The RELAP5-3D model captured trends in the data but could not reproduce measured temperatures exactly. This result is not attributed to deficiencies in the experimental data or to RELAP5–3D itself. Rather, this result likely arises due to the some of the assumptions and decisions made when the RELAP5-3D model was first developed, prior to the execution of HTTF experiments. An agreement in prediction of temperature trends but challenges reproducing HTTF temperatures within measurement uncertainty is consistent with previous analyses of HTTF in the literature. Future RELAP5-3D validation activities centered around HTTF may be able to provide greater insight into the code’s capabilities for HTGR modeling with a more finely nodalized model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation Studies of RELAP5-3D for High-Temperature Gas-Cooled Reactor Analysis Using a Refined RELAP5-3D Model of the High Temperature Test Facility

RELAP5-3D has been used extensively for high-temperature gas-cooled reactor (HTGR) analysis, but such analysis lies outside the validation basis for the code. Oregon State University (OSU) and the United States Department of Energy’s (DOE) Advanced Reactor Technologies (ART) – Gas-cooled reactor campaign worked together to design and operate the High Temperature Test Facility (HTTF) at OSU to provide validation data for prismatic HTGR thermal hydraulics analysis. Work using a previous RELAP5-3D model of HTTF demonstrated the ability to reproduce trends in HTTF data but an inability to reproduce the values measured in multiple experiments within the uncertainty. It was hypothesized that a new model with a finer radial nodalization would perform better for HTTF analysis. In this paper, we present the development of that more refined model and analyze HTTF experiments PG-27 and PG-29, a pressurized (PCC) and depressurized conduction cooldown (DCC) transient. Comparing PG-27 results to experimental data shows a better prediction of steady state and transient temperatures; however, a deeper dive reveals that better transient temperature predictions are a result of better initial conditions. The transient temperature rise in the core is comparable between the two models, but the legacy model predicts temperatures in the reflectors better. The new model demonstrates the ability to predict unique temperatures in each sector of the core during PG-29, capturing the azimuthal asymmetry; however, the temperature predictions still differ from measured temperatures. One hypothesis is that differences between the assumed and actual power distribution leads to the underprediction of the individual block temperatures. These results suggest that gaps and uncertainties in the measured boundary conditions for the HTTF tests do not allow to fully validate RELAP5-3D for prismatic HTGR analyses. The authors suspect that some of the differences between predicted and measured temperatures may be a result of uncertainties associated with HTTF itself rather than RELAP5-3D. We demonstrated improved validation for steady-state analysis, but significantly improved transient performance has yet to be recognized.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Representativity error scaling of models of the high temperature test facility

Error scaling is a critical step toward the validation of modeling capabilities for high-temperature gas-cooled reactors (HTGRs). Extensive effort is being made to bring HTGRs into the validation basis of numerous thermal-hydraulics codes. Here, this paper demonstrates how systems-level codes can be leveraged to perform error scaling analyses between an experimental facility and a plant-to-be facility. Specifically, we focus on two conduction cooldown experiments from the High Temperature Test Facility (HTTF) and the General Atomics 350 MW th modular high-temperature gas-cooled reactor (MHTGR-350). The error scaling methodology employed in this study is representativity, which in the context of this work was used to quantify how well experiments captured the physics of the plant facility by comparing sensitivity vectors between the two facilities. In addition, two different RELAP5–3D models of the HTTF were included in the comparison to determine if modeling methodologies notably impact the representativity results. The key figures of merit are the maximum block temperature and the coolant outlet temperature. The time-dependent maximum block temperature had a low representativity of below 0.1 for both models across both transients. The coolant outlet temperature had a higher representativity of around 0.6 for both models during the pressurized conduction cooldown, but it was below 0.2 for the depressurized conduction cooldown. Overall, the HTTF experiments were not representative of the transients in the MHTGR-350. However, these results can play a significant role in informing future potential experiments for HTGR systems that iterate on what the HTTF accomplished.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Code Benchmark of Depressurized Conduction Cooldown Transient in the High Temperature Test Facility

This paper presents results from modeling of a depressurized conduction cooldown (DCC) transient at the High Temperature Test Facility (HTTF) as part of the OECD-NEA Thermal Hydraulics Code Validation Benchmark for High-Temperature Gas-Cooled Reactors using HTTF Data . This paper briefly describes the benchmark and the models being used. It then presents a comparison of steady state and transient results based on the Problem 2 Exercise 1A and 1B definitions. We compare block and helium temperature distributions, mass flow distribution, and energy balance in steady state. All models show comparable mass flow distributions and energy balances. The temperatures within the core and outer regions are comparable in all models too, but inner reflector temperatures can vary significantly. Despite that, we find that the models are in good agreement for the full-power steady state. In the DCC, we look at block temperature at the core midplane and RCCS water exit temperature. The INL and ANL models are found to be in excellent agreement with one another on block temperature over time, while the agreement when the KAERI and NRG models are added into consideration is good. Differences in the transient heat removal from the RCCS cause the differences in block temperature over time in these models. The CNL models show similar trends to the INL, ANL, KAERI, and NRG models, but the temperatures are high because the volumes used in calculating the average temperature include the heater rods in the CNL models only. The HUN-REN model shows results that suggest significantly lower heat removal in the RCCS which merit further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RAVEN Template for Dynamic Representativity Analysis of the High Temperature Test Facility

These slides present a walkthrough of the template that has been developed for using RAVEN to perform representativity analysis using models of the High Temperature Test Facility and the General Atomics Modular High Temperature Gas-cooled Reactor. The presentation provides participants in the HTTF benchmark with a walkthrough on how to use RAVEN for their sensitivity analysis and how to read results from the MHTGR-350 to perform representativity

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation of the High Temperature Test Facility (HTTF) Core Using the 2D Ring Model with SAM

A two-dimensional ring model is developed with SAM to model the core of the High Temperature Test Facility (HTTF) at the system level. The ring model simplifies the complex structure of the HTTF core by converting the hexagonal rows of heaters and flow channels into layers of concentric annular rings. The ring model is first compared against a 3D-1D model where the solid structures are fully resolved in three dimensions while the fluid structures are modeled as one-dimensional flows. Comparison between the 3D-1D and the ring models shows that the latter can predict major parameters reasonably well under steady-state normal operating condition, but the heater temperatures are underpredicted. Adjustment is made to the effective thermal conductivity of the ceramic core of the ring model to improve the heater temperature predictions. Furthermore, the ring model is also used to simulate a transient Pressurized Conduction Cooldown (PCC) condition and is benchmarked with the experimental data from the HTTF Test PG-27. Good agreement is obtained between the experimental data and the predictions by the ring model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Best-estimate Modeling of the High Temperature Test Facility with RELAP5-3D

Prismatic HTGRs are a concept of interest for near-term deployment. While plenty of validation data exist for standalone neutronics or multiphysics modeling, the availability of integral effects thermal hydraulics validation data is more limited. The High Temperature Test Facility provides such data and is used as the basis for the High-Temperature Gas-Cooled Reactor Thermal Hydraulics Benchmark. This presentation presents results of best-estimate modeling of HTTF experiments PG-27 and PG-29 using the RELAP5-3D ring model developed at Idaho National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF)

HTTF at Oregon State University (OSU) Reference: General Atomics? modular high-temperature gas-cooled reactor Helium cooled, electrically heated Prismatic graphite blocks in the core and reflectors Alumina ceramic blocks are used to simulate the core and top and bottom reflectors One-fourth scale in length and diameter Most of the coolant channels in the core are full scale Lower pressure compared to the prototype reactor Over 500 instruments Designed primarily to investigate depressurized conduction cooldown (DCC) transients

97 MATHEMATICS AND COMPUTING↗