Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Power RF Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Low pressure and high power rf sources for negative hydrogen ions for fusion applications (ITER neutral beam injection) (invited)

The international fusion experiment ITER requires for the plasma heating and current drive a neutral beam injection system based on negative hydrogen ion sources at 0.3 Pa. The ion source must deliver a current of 40 A D{sup -} for up to 1 h with an accelerated current density of 200 A/m{sup 2} and a ratio of coextracted electrons to ions below 1. The extraction area is 0.2 m{sup 2} from an aperture array with an envelope of 1.5x0.6 m{sup 2}. A high power rf-driven negative ion source has been successfully developed at the Max-Planck Institute for Plasma Physics (IPP) at three test facilities in parallel. Current densities of 330 and 230 A/m{sup 2} have been achieved for hydrogen and deuterium, respectively, at a pressure of 0.3 Pa and an electron/ion ratio below 1 for a small extraction area (0.007 m{sup 2}) and short pulses (<4 s). In the long pulse experiment, equipped with an extraction area of 0.02 m{sup 2}, the pulse length has been extended to 3600 s. A large rf source, with the width and half the height of the ITER source but without extraction system, is intended to demonstrate the size scaling and plasma homogeneity of rf ion sources. The source operates routinely now. First results on plasma homogeneity obtained from optical emission spectroscopy and Langmuir probes are very promising. Based on the success of the IPP development program, the high power rf-driven negative ion source has been chosen recently for the ITER beam systems in the ITER design review process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Current Density, Long Life Cathodes for High Power RF Sources

This program was tasked with improving the quality and expanding applications for Controlled Porosity Reservoir (CPR) cathodes. Calabazas Creek Research, Inc. (CCR) initially developed CPR cathodes on a DOE-funded SBIR program to improve cathodes for magnetron injection guns. Subsequent funding was received from the Defense Advanced Research Projects Agency. The program developed design requirements for implementation of the technology into high current density cathodes for high frequency applications. During Phase I of this program, CCR was awarded the prestigious 2011 R&D100 award for this technology. Subsequently, the technology was presented at numerous technical conferences. A patent was issued for the technology in 2009. These cathodes are now marketed by Semicon Associates, Inc. in Lexington, KY. They are the world’s largest producer of cathodes for vacuum electron devices. During this program, CCR teamed with Semicon Associates, Inc. and Ron Witherspoon, Inc. to improve the fabrication processes and expand applications for the cathodes. Specific fabrications issues included the quality of the wire winding that provides the basic structure and the sintering to bond the wires into a robust, cohesive structure. The program also developed improved techniques for integrating the resulting material into cathodes for electron guns.

43 PARTICLE ACCELERATORS↗

Analysis of RF high power sources for 1MW – range, 10 MeV CW industrial accelerator.

Cobalt-60 is the dominant source of ionizing radiation for sterilizing products in the $200B/year medical device industry. Security and accessibility concerns around this radioactive material - sourced from countries including Russia and China - present national security and economic risks. There is a continued national urgency to replace such high-risk sources with low-risk alternatives such as electron or x-ray beams driven by accelerators. While e-beam sources have been in use for many years, they still represent a small portion of the market. X-ray sources are becoming economical alternatives. Meeting the processing capacity required to replace Co-60 requires a step-change in the capability, efficiency, and overall operating cost of electron accelerators to make adoption feasible. The radiofrequency (RF) power that drives accelerating cavities represents significant capital and operating costs for these accelerators. For accelerator-based systems to be a viable alternative for these applications, RF systems must be economical to manufacture, deploy, and operate.

43 PARTICLE ACCELERATORS↗

Neutral particle dynamics in a high-power RF source

Previous studies on the spatial discharge structure in the SPIDER source of negative hydrogen/deuterium ions carried out at low applied power are extended towards description of the discharge maintenance under the conditions of the actual rf power deposition of 100 kW planned for a single driver of the source. In addition to the expected higher electron density, the results show strong increase of the electron temperature and of the temperatures of the neutral species (hydrogen atoms and molecules). In the discussions, not only the spatial distribution of the plasma parameters but also that of the fluxes in the discharge (particle and energy fluxes) is involved. The obtained results come in confirmation of basic concepts for low-pressure discharge maintenance: (i) mutually related electron density and temperature as a display of the generalized Schottky condition, (ii) discharge behavior governed by the fluxes, i.e. strong nonlocality in the discharge, and (iii) a non-ambipolarity in the discharge regime, which originates from shifted maxima of the electron density and temperature and shows evidence in a vortex electron flux and in a dc current in a rf discharge, the latter resulting from a shift in the positions of the maxima of the electron density and plasma potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of a high-power RF source of negative hydrogen ions for neutral beam injection into controlled fusion devices

An injector of hydrogen atoms with an energy of 0.5–1 MeV and equivalent current of up to 1.5 A for purposes of controlled fusion research is currently under design at the Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences. Within this project, a multiple-aperture RF surface-plasma source of negative hydrogen ions is designed. The source design and results of experiments on the generation of a negative ion beam with a current of >1 A in the long-pulse mode are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of CW High Power Sources and RF Components for the Tore Supra LHCD System

The upgraded 3.7 GHz Lower Hybrid Current Drive (LHCD) system for the Tore Supra (TS) tokamak is in the process of installation. When complete, it will permit long pulse injection (1000s) at coupled power level up to 6, 5 MW. Steady state operation of high power RF sources and components is challenging and requires careful validation before the system can be commissioned on the tokamak.Results on the validation of CW klystrons, improvements on the RF components forming part of the power generation circuit and the development of an RF water load to sustain CW pulses under 700 kW RF power are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of 26 GHz Dielectric-Based Wakefield Power Extractor

High frequency, high power rf sources are needed for many applications in particle accelerators, communications, radar, etc. In this article we present a design of a 26 GHz high power rf source based on the extraction of wakefields from a relativistic electron beam. The extractor is designed to couple out rf power generated from a high charge electron bunch train traversing a dielectric loaded waveguide. Using a 20 nC bunch train (bunch length of 1.5 mm) at the Argonne Wakefield Accelerator (AWA) facility, we can obtain a steady 26 GHz output power of 148 MW. The extractor has been fabricated and bench tested, with the first high power beam experiments to be performed in the coming year.

43 PARTICLE ACCELERATORS↗

Development of 26GHz dielectric-based wakefield power extractor.

High frequency, high power rf sources are needed for many applications in particle accelerators, communications, radar, etc. In this article we present a design of a 26 GHz high power rf source based on the extraction of wakefields from a relativistic electron beam. The extractor is designed to couple out rf power generated from a high charge electron bunch train traversing a dielectric loaded waveguide. Using a 20 nC bunch train (bunch length of 1.5 mm) at the Argonne Wakefield Accelerator (AWA) facility, we can obtain a steady 26 GHz output power of 148 MW. The extractor has been fabricated and bench tested, with the first high power beam experiments to be performed in the coming year.

36 MATERIALS SCIENCE↗

The IPP RF Source: A High Power, Low Pressure Negative Ion Source For The Neutral Beam Injection System Of ITER

IPP Garching has successfully developed a RF driven negative ion source for the ITER neutral beam injection system. The RF source was chosen recently as the reference source for ITER due to its in principle maintenance-free operation. Current densities of 330 A/m{sup 2} and 230 A/m{sup 2} have been achieved for hydrogen and deuterium, respectively, at a pressure of 0.3 Pa and an electron/ion ratio of less than 1 for a small extraction area (7.0x10{sup -3} m{sup 2}) and short pulses (<4 s). The development concentrates now on extending the pulse length and extending the size of the source on two dedicated test facilities. The pulse length can be extended up to one hour at the long pulse test facility having an extraction area of 0.02 m{sup 2}. The large source test facility is equipped a large RF source with the width and half the height of the ITER beam source in order to demonstrate the homogeneity of a large RF plasma. The paper will give a short overview on the results achieved at the three test facilities of IPP; the underlying physical mechanisms are discussed with an emphasis on electron suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-MW K-Band Harmonic Multiplier: RF Source For High-Gradient Accelerator R and D

A preliminary design is presented for a two-cavity harmonic multiplier, intended as a high-power RF source for use in experiments aimed at developing high-gradient structures for a future collider. The harmonic multiplier is to produce power at selected frequencies in K-band (18-26.5 GHz) using as an RF driver an XK-5 S-band klystron (2.856 GHz). The device is to be built with a TE{sub 111} rotating mode input cavity and interchangeable output cavities running in the TE{sub n11} rotating mode, with n = 7,8,9 at 19.992, 22.848, and 25.704 GHz. An example for a 7{sup th} harmonic multiplier is described, using a 250 kV, 20 A injected laminar electron beam; with 10 MW of S-band drive power, 4.7 MW of 20-GHz output power is predicted. Details are described of the magnetic circuit, cavities, and output coupler.

43 PARTICLE ACCELERATORS↗

The Development of the Electrically Controlled High Power RF Switch and Its Application to Active RF Pulse Compression Systems

In the past decades, there has been increasing interest in pulsed high power RF sources for building high-gradient high-energy particle accelerators. Passive RF pulse compression systems have been used in many applications to match the available RF sources to the loads requiring higher RF power but a shorter pulse. Theoretically, an active RF pulse compression system has the advantage of higher efficiency and compactness over the passive system. However, the key component for such a system an element capable of switching hundreds of megawatts of RF power in a short time compared to the compressed pulse width is still an open problem. In this dissertation, we present a switch module composed of an active window based on the bulk effects in semiconductor, a circular waveguide three-port network and a movable short plane, with the capability to adjust the S-parameters before and after switching. The RF properties of the switch module were analyzed. We give the scaling laws of the multiple-element switch systems, which allow the expansion of the system to a higher power level. We present a novel overmoded design for the circular waveguide three-port network and the associated circular-to-rectangular mode-converter. We also detail the design and synthesis process of this novel mode-converter. We demonstrate an electrically controlled ultra-fast high power X-band RF active window built with PIN diodes on high resistivity silicon. The window is capable of handling multi-megawatt RF power and can switch in 2-300ns with a 1000A current driver. A low power active pulse compression experiment was carried out with the switch module and a 375ns resonant delay line, obtaining 8 times compression gain with a compression ratio of 20.

43 PARTICLE ACCELERATORS↗

Multi-antenna RF Ion Source at a High RF Power Level

A multi-antenna radio-frequency ion source with a Faraday shield is newly tested at a high RF power level in a large area negative ion source of 1/5th scale of the Large Helical Device-NNBI ion source. Inductively coupled dense hydrogen plasmas were generated uniformly over an area of 25x25 cm{sup 2} at an RF input power up to 300 kW for a 10 ms pulse duration. A large negative plasma potential for the non-Faraday shielded antenna was remarkably reduced by introducing a Faraday shield. The positive ion saturation current density measured by Langmuir probe reached 148 mA/cm{sup 2} at 174 kW around the center of the plasma. The optimal hydrogen filling pressure ranged around 0.13 Pa- 0.4 Pa for the positive ions. Ion beam extraction with a single hole ({phi} 0.5 cm) extractor has been studied systematically. A maximum H{sup -} ion beam current density of 1.6 mA/cm{sup 2} was obtained preliminarily. It was confirmed that the plasma profile was controllable by both the number and configuration of the antennas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗