ART Graphite Irradiation Update
From Advanced Graphite Creep to High Dose Graphite
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
From Advanced Graphite Creep to High Dose Graphite
SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf
This report documents all preirradiation examination material property measurement data for the graphite specimens which were to be used within the fifth Advanced Graphite Capsule (AGC-5) irradiation capsule. The AGC-5 capsule was to be the fifth in six planned irradiation capsules comprising the AGC test series that was designed to irradiate graphite specimens in a temperature range of 600 – 1100°C and medium dose levels to 7 dpa. This would provide quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades for use within very high temperature reactor designs (VHTR). However, due to the lack of commercial interest in building a VHTR design within the USA, the graphite irradiation program was redirected by DOE Advanced Reactor Technology (ART) to re-irradiate the existing specimens from AGC-1 through AGC-4 in the remaining AGC capsules to achieve higher dose levels (15 dpa) at a lower irradiation temperature range (600-800°C). These new irradiation capsules have been designated as the High Dose Graphite (HDG) capsules. This new low temperature, high dose irradiation program favors the current high temperature reactor (HTR) design of interest to the US commercial nuclear community. This report summarizes the measurements from material property tests on the designated AGC-5 specimens. Similar to past AGC runs the specimens were categorized as major graphite grades (IG-110, NBG-17, NBG-18, PCEA and 2114), smaller experimental samples (thermal diffusivity sized specimens of major grades). It is anticipated that some AGC-5 specimens may be required for use within the new HDG-1 capsule. Any specimens from this pre-irradiation testing campaign will be identified in the future HDG-1 Pre-Irradiation Data Report. AGC-5 specimen testing was conducted at Idaho National Laboratory (INL) from December 2015 to February 2018.
This report documents all pre-irradiation examination material-property measurement data for graphite specimens that are going to be used within the first high dose graphite (HDG) -1 irradiation capsule. The two new HDG capsules signify a major change to the AGC Experiment. HDG-1 and HDG-2 will replace the last two Advanced Graphite Creep (AGC) capsules (AGC-5 and AGC-6) which were designed to irradiate graphite at the extreme upper operational temperatures for a very-high-temperature reactor (VHTR) design, 1100°C. These very high temperature AGC-5 and AGC-6 capsules have been repurposed to re-irradiated specimens (from AGC-2, AGC-3, and AGC-4) at the lower temperatures of 600°C and 800°C. HDG-1 will be irradiated at 600°C and HDG-2 will be irradiated at 800°C. By re-irradiating the previous AGC specimens a total maximum neutron dose of around 15 dpa (displacements per atom) can be achieved for all major graphite grades at irradiation temperatures of 600°C and 800°C. Specimens in the HDG-1 capsule are made up of previously irradiated specimens from the AGC-2 capsule and unirradiated specimens prepared for the now discontinued AGC-5 capsule. Utilizing the irradiated specimens, a maximum neutron dose of around 15 dpa is anticipated. These new maximum dose levels will provide irradiated material property data over a total neutron dose range of 1-15 dpa at a temperature of 600°C when combined with the previous AGC-1 and AGC-2 irradiation data. This will provide quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades for use within high temperature reactor designs. Similar to previous AGC test trains, HDG-1 includes the major graphite grades (IG-110, NBG-17, NBG-18, PCEA, and 2114) as well as adding the very fine-grain grade IG-430 which is of interest to the Molten Salt Reactor (MSR) designs. Also new to the HDG-1 capsule are 90 smaller geometry specimens designated as pencil specimens. These specimens take up only one third the space of a standard creep size specimen. This increased number of specimens will enhance property measurement statistics because they will provide 3 times the control specimen data at a position that would otherwise only have a single measurement.
This report documents all pre-irradiation examination material-property measurement data for graphite specimens that are going to be used within the first high dose graphite (HDG) -1 irradiation capsule. The two new HDG capsules signify a major change to the AGC Experiment. HDG-1 and HDG-2 will replace the last two Advanced Graphite Creep (AGC) capsules (AGC-5 and AGC-6) which were designed to irradiate graphite at the extreme upper operational temperatures for a very-high-temperature reactor (VHTR) design, 1100°C. These very high temperature AGC-5 and AGC-6 capsules have been repurposed to re-irradiated specimens (from AGC-2, AGC-3, and AGC-4) at the lower temperatures of 600°C and 800°C. HDG-1 will be irradiated at 600°C and HDG-2 will be irradiated at 800°C. By re-irradiating the previous AGC specimens a total maximum neutron dose of around 15 dpa (displacements per atom) can be achieved for all major graphite grades at irradiation temperatures of 600°C and 800°C. Specimens in the HDG-1 capsule are made up of previously irradiated specimens from the AGC-2 capsule and unirradiated specimens prepared for the now discontinued AGC-5 capsule. Utilizing the irradiated specimens, a maximum neutron dose of around 15 dpa is anticipated. These new maximum dose levels will provide irradiated material property data over a total neutron dose range of 1-15 dpa at a temperature of 600°C when combined with the previous AGC-1 and AGC-2 irradiation data. This will provide quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades for use within high temperature reactor designs. Similar to previous AGC test trains, HDG-1 includes the major graphite grades (IG-110, NBG-17, NBG-18, PCEA, and 2114) as well as adding the very fine-grain grade IG-430 which is of interest to the Molten Salt Reactor (MSR) designs. Also new to the HDG-1 capsule are 90 smaller geometry specimens designated as pencil specimens. These specimens take up only one third the space of a standard creep size specimen. This increased number of specimens will enhance property measurement statistics because they will provide 3 times the control specimen data at a position that would otherwise only have a single measurement.
The main goal of the High dose graphite 1 Advanced test reactor experiment was to study nuclear grade graphite at high fluences. Additional supplementary optical fiber instrumentation was added to this long duration experiment for instrumentation development purposes. The supplementary instrumentation consisted of two pure silica core, fluorine doped cladding optical fibers each etched with 9 fiber Bragg gratings, one fiber being heat treated for 9 hours at 750 C and 16 hours at 750 C, the other being heat treated for 24 hours at 550 C and 48 hours at 650 C. Fiber Bragg gratings are known to have issues of measurement drift when in high temperature and high radiation environments like what is encountered in the Advanced test reactor. At the culmination of this experiment, the optical fibers saw ~1.3E21 n/cm2 total fluence, which is at the highest fluences that fiber Bragg gratings have been studied to date. Reported here is the analysis of this data including radiation induced shift and changes in sensitivity.
The Graphite Technology Development Project provides data to support the design of graphite core components within specific reactor service conditions of the next generation of high-temperature, gas-cooled nuclear reactors. Physical, mechanical, and thermal properties of nuclear grade graphite were characterized for specimens that were unirradiated, irradiated, and irradiated under various stress conditions. The material properties include diameter, length, mass, density, compressive strength, tensile strength, flexural strength, modulus, resistivity, thermal diffusivity, and thermal expansion coefficient. Baseline graphite specimens are unirradiated from different grades (2114, IG-110, NBG-17, NBG-18, and PCEA) and different types used in different characterization tests (compressive, flexural, tensile, one-inch cylinder, and quarter-inch cylinder). The Advanced Graphite Creep (AGC) irradiation specimens are from a much larger number of grades and cylinder types (creep, piggyback, and pencil). For baseline graphite, characterization data for 7,756 specimens extracted from thirteen graphite billets were captured to the NDMAS database. For AGC experiments, four irradiation campaigns have been completed: AGC-1, AGC-2, AGC-3, and AGC-4. The ongoing HDG-1 (High-Dose Graphite) experiment, which began irradiation with Cycle 168B on August 26, 2020, includes specimens previously irradiated in AGC-2 in addition to the specimens originally destined for AGC-5.. Besides the characterization data, the AGC data includes irradiation monitoring and physics data representing the irradiation conditions of AGC specimens. Currently, all data for AGC-1, AGC-2, and AGC-3 have been captured to the NDMAS database. Only AGC-4 pre-irradiation and irradiation monitoring data have been captured, and HDG-1 pre-irradiation data are in process of being captured for unirradiated specimens. To date, a total of 38,149 material property records have been captured into NDMAS database for baseline and AGC specimens. All characterization data are qualified for use according to their perspective data verification reports. For the AGC irradiation campaigns, a total of 41,502 qualified physics calculation records were added for AGC-1, AGC-2, and AGC-3. Finally, a total of 173,698,505 AGC irradiation monitoring data records (thermocouple temperature, gas flow rate, gas pressure, gas moisture, applied load, and specimen displacement) have been captured to NDMAS; the majority of those records (~94%) are qualified data records.
The USA DOE Advanced Reactor Technologies (ART) graphite R&D program supporting HTR design is one of the longest running nuclear graphite R&D programs. Significant progress has been made in several areas of research within this extensive program including unirraidated and irradiated testing of nuclear graphite, oxidation results and modeling, fracture behavior, irradiation damage studies, and several international collaboration studies. The latest results in these research areas as well as a discussion of a new direction in nuclear graphite irradiation for the USA program will be presented. Recently, the USA made a decision to support moderate to high dose irradiation of nuclear graphite (0.5 to 15 dpa). This will provide irradiation data for graphite HTR core components up to 15 dpa for numerous nuclear graphite grades. The irradiation plan and a tentative schedule for this new irradiation direction will be presented in detail.
Here. a novel dual-reflection configuration is introduced for the International Tokamak Experimental Reactor (ITER) core x-ray spectrometer to fit the allocated space where it will be placed accompanied by moving the detectors backward to reduce the incident radiation dose. The highly oriented pyrolytic graphite, which has a mosaic structure of microscopic crystallites, is chosen for the front reflector motivated by higher x-ray throughput and stronger misalignment tolerance compared to the perfect crystal reflector. In the ITER core x-ray spectrometer, a combination of several reflector-deflected Lines of Sight (LOSs) and a direct LOS is proposed for the first time named X-Ray Crystal Spectroscopy Core (XRCS-Core). The system is optimized to observe lines from externally seeded xenon and the intrinsic tungsten impurity, meeting both port integration needs and measurement requirements. Its spectral performance is simulated using an analytical-raytracing mixed code——XRSA, showing good imaging quality with a spectral resolution higher than 8000. The XRCS-Core system is thought to be applicable in various ITER scenarios through the assessment taking into account the spectrometers’ specifications and the chosen lines’ emissivity in different plasma parameters.
A vein structure, which becomes more pronounced with increasing ion dose, was found on the surface of polycrystalline HOPG (highly oriented pyrolytic graphite) implanted by ex situ C + (up to 1.8 × 10 17 ions/cm 2 ), and in situ Ar + in a transmission electron microscope (TEM). These veins are found to be independent of the crystallographic orientations and are associated with the formation of pores. Underneath the veins, a triangular-shaped core was formed with the graphite platelet inside the core displaced up towards the surface. A macro-scale ‘ruck&tuck’ geometry was thus generated at these triangle structure boundaries. Progressive movement of dislocations along basal planes during irradiation was observed, and a mechanistic model was proposed on this basis to explain the vein formation. A small increase of c-spacing was observed with irradiation but it is believed that macro-scale vein formation plays a more vital role in the dimensional and property changes in polycrystalline graphite, especially when a stress gradient is present. Here, the model proposed also explains the change of thermal expansion in HOPG with irradiation. Together with Heggie’s ‘ruck&tuck’ and Barsoum’s ‘ripplocations’ models, the present model is considered to have provided an additional experimentally proven mechanism responsible for irradiation behaviour in graphite materials.
Research examining radiation damage and its effects in graphite began in the 1940’s during the development of moderated nuclear reactors. Interest in this topic is expanding because of emerging applications associated with fullerenes and carbon nanostructures as well as its long-standing use as a fission moderator. In this work, we report the measurements of the full phonon density of states of irradiated nuclear graphite using inelastic neutron scattering experiments at room temperature. The samples were previously exposed to different levels of neutron doses and irradiation temperatures. The phonon density of states of perfect and defected graphite supercells including different configurations of vacancies and interstitials were calculated using first-principles direct method. Despite high neutron irradiation doses, the scattering measurements show that the induced damage is localized, and the layered structure is preserved. In conclusion, a comparison of the measured phonon densities of states of irradiated samples with those calculated of defected supercells indicates that the main changes observed are mainly attributed to formation of vacancies.
Here, an experimental methodology using photothermal radiometry is developed for the accurate measurement of bulk thermal diffusivity of nuclear fuels and materials irradiated to high doses. Under these conditions, nuclear fuels, such as uranium oxide, and moderator materials, such as graphite, become friable, which requires characterization techniques that can accommodate irregularly shaped fragments. Photothermal radiometry, a good candidate for this application, involves locally heating a sample by using a laser and measuring the temperature field by monitoring blackbody radiation. The interaction volume for this study, less than a millimeter, is carefully chosen to sample a statistically significant number of large-scale structural features, such as pores and gas filled bubbles, and is small enough that the sample fragments can be treated as a thermal half-space. The thermal diffusivity standards considered in this study cover a range of thermal diffusivities representative of both fresh and spent nuclear fuels. We also consider a sample having a porous microstructure representative of large-scale structures found in materials irradiated to high doses. Our measurement methodology circumvents complex thermal wave models that address optical diffraction, nonlinear transfer function associated with blackbody radiation, and finite sample size effects. Consequently, the large measurement uncertainty associated with modeling these effects can be avoided. While the emphasis here is on nuclear fuels and materials, this measurement approach is well suited to measure thermal transport in a variety of technologically important materials associated with advanced synthesis techniques. Examples range from small, exotic single crystals grown using hydrothermal growth techniques to additively manufactured components having complex geometries.
To address the challenges of increased beam power and target survivability associated with next-generation particle production beam lines, high dose, high-energy proton beam conditions are simulated using irradiation from low-energy ion beams. A low-energy ion irradiation study of POCO ZXF-5Q graphite under conditions similar to those of the NuMI NT-02 neutrino production target at the Fermi National Accelerator Laboratory is reported. Helium ion irradiation was performed at 100 ∘ C to a maximum damage level of 0.9 displacements per atom (DPA). Irradiation induced hardening, swelling of the irradiated region, inter-plane lattice expansion, and intraplane lattice contraction with increasing ion fluence was observed using micromechanical (nanoindentation, atomic force microscopy) and electron microscopy (high-resolution imaging, selected area diffraction) characterization. Similar changes were also observed in post irradiation examination of the NT-02 target indicating that ion irradiation can be a valuable tool for estimating radiation damage in proton beam targets. Caution must be exercised though, because the hardening, lattice alteration, and swelling occur to different magnitudes for a given damage level. The observed hardening and embrittlement were greater for ion irradiated graphite. For He ion irradiated samples the lattice spacing changes were smaller at low damage levels (78% less expansion and 71% less contraction at 0.1 DPA) and larger at high damage levels (38% more expansion and 5% more contraction at 0.9 DPA) relative to that observed in the NT-02 target. The magnitude of swelling was 8.5× greater under ion irradiation which is influenced by the differing damage gradients and inclusion of implanted He ions in the region of interest.
Exposure of graphite targets to high intensity proton beams at neutrino production facilities causes changes in the target material that can result in a shortened operation lifetime. The dominant factors in this process are currently thought to be mechanical in nature resulting primarily from microstructural effects that lead to thermal and structural changes in bulk material properties. As currently planned beam facilities with increased proton energy and intensity begin to come online it will be important to thoroughly understand these processes, and ideally to be able to predict the effects of new beam designs on target properties. Direct analysis of targets exposed to existing high-energy proton beams is complicated by several factors, such as very limited access to proton beam facilities, high associated costs, irradiation times on the order of months, and the resulting radioactivity of irradiated samples that requires special facilities for post-irradiation examination. Much of the existing literature concerning irradiation damage in graphite has been focused on the needs of the nuclear engineering community, however high-energy proton targets operate in a much different environment. In comparison to graphite irradiated in a nuclear reactor, graphite used in proton beam targets receives a higher dose rate, have greater gas production, and experience short irradiation pulses as opposed to continuous irradiation. Low-energy ion irradiation offers a method of inducing similar levels of radiation damage to high-energy protons while avoiding many of the difficulties and limitations associated with high-energy proton beams and the corresponding activated specimen testing. My research described in this thesis focused on investigating how low-energy ion irradiation could be used to induce the same or similar types of microstructural alteration and mechanical property degradation as that seen in high-energy neutrino production target graphites by varying damage le vels and irradiation temperatures prior to post-irradiation characterisation.
Defect evolution in nuclear graphite has been studied in real time using high-temperature in situ transmission electron microscopy. In situ electron-irradiation was conducted at 800 °C on a 200 kV transmission electron microscope with a dose rate, given in terms of displacements per atom per second, of approximately 1.46 × 10 –3 dpa/s. Defect domains consisting of ordered arrangements of pentagons, hexagons, and heptagons exist intrinsically in nuclear graphite and in addition are readily produced via electron-irradiation; however, at elevated temperatures these defect domains undergo atomic rearrangements resulting in the formation of carbon nanostructures via curling and closure of the basal planes. The formation of fullerenes and other structures due to thermal annealing or high-temperature electron-irradiation has been observed in disordered regions of the microstructure and interstitially between basal planes. Furthermore, these defect structures result in localized swelling and expansion of crystallites along the c axis; thus, it is proposed as one of the many atomic mechanisms involved in the dimensional change of nuclear graphite subjected to high-temperature irradiation.
Irradiation-induced defect evolution in graphite is particularly important for its application in graphite-moderated nuclear reactors. The evolution of defects directly influences macroscopically observed property changes in irradiated nuclear graphite which, in turn, can govern the lifetime of graphite components. This article reports novel defect structures and the irradiation response of microstructural features occurring in high-temperature irradiated nuclear graphite IG-110. High resolution transmission electron microscopy (HRTEM) was used to characterize specimens neutron-irradiated at a high temperature (≥ 800°C) at doses of 1.73 and 3.56 atomic displacements per atom (dpa). Concentric shelled and fullerene-like defects were found to result in swelling along the c-axis and contraction along the a/b-axis of crystallites. Furthermore, such defects are shown to occur within, and partially fill, Mrozowski cracks prior to turnaround dose. In addition, in situ TEM under similar irradiation conditions was used to capture the real-time dynamic evolution of defects, providing unambiguous analysis of the evolution of the graphite structures during irradiation. Here, the results suggest the mainstream theory for radiation damage in nuclear graphite (which assumes additional basal plane formation as the sole reason) to be an incorrect interpretation of defect evolution contributing to irradiation-induced property changes at higher temperatures.
Introduction Comparison of Graphite Oxidation Rates for Irradiated and Unirradiated NBG-25 (Rebecca Smith and Austin Matthews, INL) Annealing effect over range of oxidation temperatures Irradiation effect (~6.5 dpa) over range of oxidation temperatures Dose dependency of irradiation effect Generation IV International Forum High Level Deliverable Summary of DOE ART Historic Oxidation Research (Cristian Contescu, ORNL) Publications issued over the last ~10 years Acute and chronic oxidation ASME Graphite Oxidation Task Force (C. Contescu, Paul Ryan, ORNL, Joe Bass, A. Matthews, R. Smith, INL) Collaborative effort headed by ORNL and engaging INL and others Initial review of relevant oxidation discussion in ASME code ASTM Activities (C. Contescu) Virtual Meetings New and Revised Standards
Microstructural changes induced by neutron irradiation of superfine grain graphite G347A (Tokai Carbon, Japan) were examined by nitrogen adsorption at 77K and by three microscopy techniques (SEM, TEM and FIB-SEM tomography). The specimens were irradiated at doses of up to 30 dpa, covering stages before and after the turnaround fluence at three temperatures (300, 450, 750 °C) of their irradiation envelope. The initial graphite densification at low fluences did not produce any detectable effect in the pore size range (<350 nm) measured by gas adsorption. However, graphite irradiated at high fluences, after turnaround, showed severe structural changes. At all three temperatures and high irradiation fluences, gas adsorption revealed significant increase of the volume of narrow mesopores (<5–20nm) and up to five times increase of BET surface area, both in linear relationship with the relative volume expansion. Analysis of microscopy images showed multiplication of fine macropores (>50 nm) at high irradiation fluences and more structural changes on multiple scales, from nanometers to microns. This work demonstrates the unique ability of gas adsorption techniques to analyze open pores with sizes between sub-nanometer and sub-micron in bulk nuclear graphite, with supporting microscopy results.