Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Heat flux sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A high-temperature heat flux sensor using the transverse Seebeck effect in elemental rhenium

Heat flux sensors compatible with hot environments are critical to advance aerospace, materials, and energy generation technologies that cope with extreme thermal conditions. In this work, we report on the development and characterization of a high-temperature heat flux sensor using the transverse Seebeck effect in rhenium single crystals. The sensor leverages refractory alloys and ceramics compatible with temperatures exceeding 1000 °C. The heat flux sensor was characterized from room temperature to 500 °C using a temperature-controlled calibration facility. At constant temperature, the sensor’s voltage output is linear with respect to the absorbed heat flux. The responsivity of the sensor varies with temperature, from 1.3 μV/(W/cm 2 ) at room temperature to −3.2 μV/(W/cm 2 ) at 500 °C, increasing monotonically in magnitude after changing sign from positive to negative at approximately 300 °C. The experimental results are in good agreement with analytical predictions of the sensor’s temperature-dependent responsivity, which suggest a further increase in magnitude up to −7.4 μV/(W/cm 2 ) at 1000 °C. These results highlight the unique characteristics of rhenium as a TSE transducer. The design offers compatibility with a wide range of operating temperatures and yields a measurement sensitivity that increases as the environmental conditions become more challenging.

20 FOSSIL-FUELED POWER PLANTS

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series are: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and to develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

Ben Swartout

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series were: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

TVAC

Thin Film Sensors for Fission Surface Power

Physical sensors fabricated with thin films could result a significant savings in space and weight with improved reliability for monitoring the long-term operation of fission surface power systems. Thin film sensors of 1 µm or less are attractive for FSP applications because they can be incorporated onto component surfaces with minimal machining and the additional weight to a system is minimal compared to thick film-, wire-, or foil-based sensors. The thin, surface fabrication of the sensors is also expected to make them less susceptible to deep dose effects that affect thicker sensors. An overview of thin film sensors using thermocouples and resistive elements designed, fabricated, and demonstrated at GRC for aerospace applications exceeding 900°C is presented.

Physical Sensors

A network of soil moisture, soil temperature, air temperature, net radiation, ground heat flux and ground water for Chicago, Illinois

This dataset contains environmental monitoring data collected using solar-powered Multi-Function Research (MFR) Long Range Wide Area (LoRaWAN)-enabled nodes at 11 sites in Chicago, Illinois, as part of the DOE Urban Integrated Field Lab CROCUS project. The MFR node system consists of an Input/Output Digital Input Module (IB8) interface box (ICT International) providing wired connections for environmental sensors and an MFR-Node-L data logger that manages power, data processing, and LoRaWAN communication. The wireless data are ingested via Sage network (https://sagecontinuum.org/) nodes that contain LoRaWAN antennae. Measurements were collected from 11 MFR nodes deployed across Chicago State University (CSU), Northeastern Illinois University (NEIU), Northwestern University (NU), University of Illinois Chicago (UIC), West Woodlawn "Blacks in Green" (BIG), and Indian Boundary Prairies (IBP). Each MFR node supports a consistent suite of sensors measuring atmospheric, soil, and hydrological variables. Atmospheric measurements include 2m air temperature (°C), 2m vapor pressure deficit (kPa), and 2m shortwave/longwave radiation (incoming and outgoing, W/m²) measured using ATH-VPD and Apogee SN500 sensors. Soil measurements include volumetric water content (VWC, %) and temperature (°C) at four depths (15, 30, 45, and 60 cm below surface) using Meter Teros54 sensors, and heat flux (W/m²) at 10 cm depth using Huske HFP01-05 sensors. At selected locations, Meter Hydros21 sensors measure groundwater depth (mm), specific conductivity (dS/m), and temperature (°C). The dataset includes timestamps, site identifiers with location names, device IDs, Global Positioning System (GPS) coordinates, variable names with units, measurement depths, values, sensor names, and Sage node identifiers. All timestamps are in local Chicago time (CDT/CST). Quality control flags are provided using a 6-bit binary system indicating physical range violations, step spikes, 24-hour flat-line conditions, 6-hour jitter, 7-day ultra-low variance, and persistent high offset. Data is provided in CSV and CF-compliant NetCDF formats. This dataset is part of a larger collection of CROCUS environmental monitoring data, including linked datasets from Air Quality Transmitter (AQT) sensors, Weather Transmitter (WXT) sensors, and Sap Flow Meter (SFM1x) sensors.

Chicago

Development of a High-Intensity Heat Flux Gauge and Characterization Facility (Final Report)

Sandia National Laboratories (SNL) and Hukseflux Thermal Sensors (HTS) collaborated to advance the design and calibration of high-intensity heat flux gauges capable of measuring 2500 kW/m². An industry trade study was first conducted and highlighted the need for enhanced gauge designs and calibration methodology & services suited for high-intensities and broadband flux. We then developed, tested, and evaluated three prototype gauge designs along with four distinct coating types, each designed to extend the measurable flux range of existing HTS products to higher intensity levels. Following a down selection process, the project team refined the focus to a final product design, incorporating updated features to enhance its robustness during high flux exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Meteorological and Soil Data from Ecohydrology Sensor Towers at Pump House and Snodgrass Mountain in East River Watershed, Colorado, 2019-2025

This data package includes hourly meteorological and soil sensor data at eight ecohydrology monitoring sites in East River Watershed, Colorado as part of the Watershed Function Scientific Focus Area (WFSFA) research led by Lawrence Berkeley National Lab (LBNL). Four field sites were located on the hillslope of East River (ER) near Pump House (PH) at Mount Crested Butte (ER-PHS1 to 4), and the other four are in the Snodgrass Mountain (SG) area (SG-EHS5 to 8). In terms of vegetation cover, three sites are in montane grasslands (ER-PHS1, ER-PHS2, and SG-EHS5), three are below evergreen conifer canopy (ER-PHS3, SG-EHS6, and SG-EHS7), and two are below deciduous aspen canopy (ER-PHS4 and SG-EHS8). The monitoring period began in October 2019 at the East River sites, in October 2020 at SG-EHS5 and SG-EHS6, and in October 2021 at SG-EHS7 and SG-EHS8. In September 2024, all four East River sites were fully retired. The four Snodgrass Mountain sites remain active. Each site is equipped with a comprehensive suite of meteorological sensors on a tripod and soil sensors that measure weather, energy fluxes, and soil variables. This data package includes measurements from ten different types of sensors and up to thirteen individual sensors per site, including (1) a weather station (measurement height ranges from 2.8~3.8 meters (m) above ground), (2) a quantum sensor for photosynthetic active radiation (PAR) (2.4~3.3m), (3) a net radiometer (1.7~2.1m), (4) an infrared radiometer (1.6~2.2m), (5) a sonic distance sensor (1.5~1.9m), (6) a soil carbon dioxide (CO2) flux chamber (0m), (7) a soil heat flux plate (-0.05m below ground), (8) a soil oxygen sensor (-0.3m), (9) a soil water potential sensor (-0.3m), and (10) soil water content sensors at 3~4 depths (-1.15 ~ -0.1m). A total of twenty-three variables is reported in this data package, including (1) atmospheric variables: air temperature (TA), atmospheric pressure (PA), vapor pressure (VP), and vapor pressure deficit (VPD), (2) precipitation variables: rain precipitation (P) and snow depth (D_SNOW), (3) energy fluxes variables: four-component net radiation (NETRAD) (shortwave/longwave incoming/outgoing radiation, SW_IN, SW_OUT, LW_IN, LW_OUT), photosynthetic photon flux density (PPFD), and soil heat flux (G), (4) soil variables: soil water content (SWC), soil water potential (SWP), soil temperature (TS), soil bulk electrical conductivity (COND_SOIL), and soil gaseous oxygen concentration (O2_SOIL), (5) wind variables: two-dimensional wind speed (WS), gust speed (WS_MAX), and wind direction (WD), and (6) surface variables: surface infrared temperature (T_CANOPY) and soil CO2 flux (CO2_SOIL). Please see the Methods section for data processing and QA/QC steps taken to generate the hourly datasets. The following files are included in this data package (notes on version: v{x}-{y}, where x is the metadata version, and y is the data version, when applicable): (1) “metadata_site_v{x}-{y}.csv” - a site metadata file that summarizes location information of all sites, including site ID, description, coordinates, timeframe, elevation, and vegetation cover, (2) “metadata_instrument_v{x}-{y}.csv” - an instrument metadata file that summarizes sensor information of all sites, including sensor manufacturer and model, measurement height, and sampling and averaging interval of all variables, (3) "data_{SITE_ID}_v{x}-{y}.csv" - eight data files that contain hourly data of each site indicated by {SITE_ID} in the filename, (4) “/figure/data_{SITE_ID}_v{x}-{y}.png" - eight figures that help visualize data of each site indicated by {SITE_ID} in the filename, (5) “/photo/*” - photos of each site indicated by {SITE_ID} in the filename, and (6) four file level metadata (flmd.csv) and data dictionary (*_dd.csv) files that summarize file, header, column, and variable information of all files. Notes: (1) Measurement height: Each variable name is followed by conventional positional qualifiers “H_V_R”, where H indicates the relative horizontal positions of that specific variable, V the vertical positions, and R the replicates. In this data package, only the vertical qualifier V varies, and V increases from the highest vertical position (V=1) to the lowest. Variables with the same qualifier are not necessarily measured by the same sensor, and the same variable with the same qualifier across different sites are not necessarily measured at the same height. Please refer to “metadata_instrument.csv” for the sensor information and measurement heights, and whether a variable is measured below the canopy. (2) Variable availability: Snow depth is not available at ER-PHS3 and SG-EHS7. SWC, soil temperature, and soil bulk EC at the deepest depth (<-1m) are not available at SG-EHS6 and SG-EHS7. The missing value code for numeric variables is -9999, except for SWP. For SWP, the missing value code is +9999, because SWP values are negative. (3) Sampling frequency: Please refer to “metadata_instrument.csv” for the increase of sampling frequency of some variables from 30-min to 1-min at ER-PHS1 to 4 in July 2020. (4) Sensors: While the methods of each sensor are not detailed, all sensors are commercially available, and their methods can be found in their manuals. Please refer to “metadata_instrument.csv” for the sensor manufacturer and model information. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES

Upper ocean mixing, surface heat fluxes, and heat content variability in the upper 150 m during Hurricane Laura (2020)

Observations (from thermistor sensors and a hurricane glider) and model-based temperature were used to answer questions including the following: 1) What physical and environmental conditions explain the rapid intensification of Hurricane Laura? 2) How did the pre-existing warm mixed layer at Stone mooring (StM) influence the degree of cooling in the mixed layer? 3) How did vertical mixing, surface heat fluxes, and advective processes collectively shape the mixed layer heat evolution at StM? Observations measured by thermistor sensors showed that Hurricane Laura induced a cooling of -1.2oC in the mixed layer when Hurricane Laura’s wind speed increased to 47 m/s on 26 August. This contrasts with the -1.04oC mixed layer temperature change estimated from model-based temperature. At StM, the presence of a 31oC warm mixed layer and elevated heat content (60-80kJ/cm2) effectively preconditioned the upper ocean ahead of Hurricane Laura’s passage. After Hurricane Laura passed, turbulent mixing associated with the storm transported the heat anomalies downward into subsurface layers. In addition, this study shows that a surface heat flux of 5.04 kJ/cm2 supported the intensity of Hurricane Laura as it traversed over the StM. Using a mixed layer heat balance model, this study shows that entrainment flux and surface flux mostly contributed to the observed change in the mixed layer temperature.

Tsai, Senam

Surface Energy Balance System (SEBS) Instrument Handbook

A Surface Energy Balance System (SEBS) has been installed collocated with each deployed ECOR system at the Southern Great Plains (SGP), North Slope of Alaska (NSA), Tropical Western Pacific (TWP), ARM Mobile Facility 1 (AMF1), and ARM Mobile Facility 2 (AMF2). The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

54 ENVIRONMENTAL SCIENCES

Surface Energy Balance System (SEBS) Instrument Handbook

A surface energy balance system (SEBS) has been installed collocated with each deployed eddy correlation flux measurement system (ECOR) after 2010 at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility Southern Great Plains (SGP) observatory, North Slope of Alaska (NSA) observatory, Eastern North Atlantic (ENA) observatory, and the first, second, and third ARM Mobile Facilities (AMF1, AMF2, AMF3). A SEBS was also deployed at the Tropical Western Pacific (TWP) site, before it was decommissioned. Data from these sites, including the retired TWP, are available in the ARM Data Center. The SEBS consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil temperature, soil moisture, and soil heat flow measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

54 ENVIRONMENTAL SCIENCES

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION

A large-eddy simulation exploration of the assumptions used in retrieving entrainment from a mixing diagram approach with ground-based remote sensors

Entrainment is a crucial component of the atmospheric boundary layer (BL) moisture and heat budget. While usually thought of as only entrainment flux, entrainment within the mixed layer budget equation is really composed of two terms: the flux of a property across the boundary separating the BL from the free troposphere and the change in the concentration of a property as the depth of the BL changes. In a recent study, Wakefield et al. (2023) used ground-based remote-sensing observations to estimate entrainment flux as the residual of a mixing diagram framework that was applied to the daytime convective boundary layer. This present work uses large-eddy simulation (LES) to examine how well this residual assumption for entrainment fluxes alone compares to the actual sum of those two entrainment terms derived from spatial averages of the LES output. We highlight the importance of the second entrainment term in closing the mixed layer budget and show that the residual assumption does not represent entrainment flux only but rather a total entrainment term when the boundary layer depth is changing.

Rosenberger, Tessa E. [Cleveland State Univ., Clev

AmeriFlux FLUXNET-1F US-GL1 Stannard Rock

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-GL1 Stannard Rock. This is the FLUXNET version of the carbon flux data for the site US-GL1 Stannard Rock produced by applying the standard ONEFlux (1F) software. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris [Environment and Climate Change Cana

Synthesizing intermetallic thermoelectric materials using metal flux growth method

With zero energy poverty by 2050 goals, exploring innovative energy technologies is essential. Thermoelectric materials (TEMs) have the potential to harness waste heat and convert it to electricity (e.g., for spacecraft power, sensors, and cryogenic cooling). Two limitations of thermoelectric compounds are their low efficiency and limited pool of materials. Optimizing the efficiency of TEMs is challenging due to the interdependent relationship between electrical and thermal conductivity. A deeper understanding of electronic properties and lattice thermal conductivity is necessary to “understand, predict and ultimately control” the thermoelectric properties of TEMs. Understanding the influence of light-atom-doping and intrinsic defects on the electronic properties of the f-element containing TEMs are important questions that need to be answered to design and synthesize TEMs with optimal parameters. The purpose of this work is to understand how doping f-element based TEMs with light elements, such as carbon and boron, would impact the crystal structure, bond lengths, band gaps, and thermoelectric characteristics. High-quality f¬-element containing intermetallic single crystals are grown in metal flux media. In molten metal flux growth method, one or more low-melting metals such as aluminum, gallium, tin, and bismuth are used in excess as the reaction medium. As these are solution-state reactions, we can use lower temperatures than solid-state reactions and isolate the kinetic products instead of the thermodynamically stable compound. Then these are characterized using X-ray diffraction, scanning electron microscopy, energy dispersive spectroscopy, magnetization, electrical and thermal conductivities, and thermoelectric power.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C

Application of a Physics-Informed Convolutional Neural Network for Monitoring the Temperature Fields in High-Temperature Gas Reactors

Here, this work presents current advances in applying a physics-informed convolutional neural network (CNN) to evaluate temperature distributions in advanced reactors. Our goal is to demonstrate that the CNN can reconstruct temperature fields within the solid region of a prismatic fuel assembly in a high-temperature gas reactor (HTGR) with sensor data available in only a few cooling channels. Before that, we showcase the superior performance of the physics-informed CNN in comparison to a purely data-driven multilayer perceptron (MLP), considering a canonical heated channel setup. This analysis shows the advantages of our approach and justifies its choice. The datasets employed here are obtained upon numerical simulations performed with codes under the Nuclear Energy Advanced Modeling and Simulation program. This work is important, as industry experience indicates that the assembly material in HTGR concepts is prone to large thermal-mechanical loads nearing operational limits. This makes it crucial to characterize peak temperatures and their distributions near hot spots. Modern thermocouples are unreliable in these types of harsh environments because of the high neutron fluxes and elevated temperatures involved. The CNN-based field reconstruction represents an attractive solution, enabling sensor arrays in less aggressive locations and augmenting indirect predictions for less accessible regions. The results show that the CNN reduces prediction errors by orders of magnitude in comparison to the MLP, considering the simple yet well-representative heated channel case. In the case of the HTGR fuel assembly, the CNN can successfully reconstruct temperature fields over various cooling regimes. Furthermore, we also explore the algorithm’s ability to detect abnormalities. Interestingly, the CNN proves it has the capacity to detect blockage in one of the noninstrumented cooling channels.

Machine learning