Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Head”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tensile Tests of Round-head, Flat-head, and Brazier-head Rivets

An investigation was conducted to determine the tensile strength of round-head (AN43C), flat-head(AN442), and brazier-head (AN4556) aluminum-alloy rivets because of the scarcity of information on the tensile strength of rivets. The results of the investigation are presented as curves that show the variation of the ratio of the tensile strength of the rivet to the tensile strength of the rivet crank with the ratio of the sheet thickness to the rivet diameter for the different types of rivet.

Schuette, Evan H

Effects of vestibular loss on head stabilization in response to head and body perturbations

Control of head position during postural responses is important to facilitate both the interpretation of vestibular signals and the stabilization of gaze. In these experiments, we compared head stabilization for two different postural tasks: 1) in response to perturbations at the head, and 2) in response to perturbations induced at the support surface, which perturb both body and head position. To determine whether normal vestibular function is necessary for head stabilization in these two tasks, responses to forward and backward mechanical perturbations of the head and body were compared for 13 normal subjects and 4 patients with profound bilateral vestibular loss (two with vestibular loss in adulthood and two in infancy). Normal subjects showed little neck muscle activity for body perturbations, but large, early activations in both neck extensors and flexors for head perturbations. In contrast, vestibular patients showed excessive neck muscle activation for body perturbations and reduced or absent neck muscle activity for head perturbations. Patients with vestibular loss in adulthood also showed increased head acceleration in response to both head and body perturbations, but patients with vestibular loss in infancy showed more normal head accelerations. For body perturbations, the differences in head acceleration between patients and normals were greater for later head acceleration peaks, indicating poor head control during the execution of the postural response. Trunk angle changes were also higher in the patients for forward body perturbations, indicating that poorer control of trunk position could have contributed to their poorer head stabilization. These results indicate that the vestibular system plays an important role in head and trunk stabilization for both head and body perturbations. However, the more normal head accelerations of the patients with infant vestibular loss also indicate that other mechanisms, possibly involving neck reflexes, can at least partially substitute for the vestibular system to provide head and trunk stabilization.

NASA Discipline Neuroscience

Head perturbations during walking while viewing a head-fixed target

Inexpensive, head-fixed computer displays are now available that subjects can wear during locomotion. Our hypothesis is that viewing a head-fixed visual display will change the character- istics of rotational head perturbations during natural walking. Using a 3-axis angular rate sensor, we measured head rotations during natural or treadmill walking, in 10 normal subjects and 2 patients with deficient vestibular function, as they attempted to view (1) a stationary target at optical infinity; and (2) a target at a distance of 20 cm rigidly attached to the head. Normal subjects and patients showed no significant change in the predominant frequency of head rotations in any plane (ranging 0.7-5.7 Hz) during the two different viewing tasks. Mean peak head velocities also showed no difference during the two viewing conditions except in the yaw plane, in which values were greater while viewing the near target. Predominant frequencies of head rotations were similar in the pitch plane during natural or treadmill walking; however, peak velocities of pitch head rotations were substantially greater during natural walking. One vestibular patient showed modest increases of head velocity during natural walking compared with normal subjects. Rotational head perturbations that occur during natural walking are largely unaffected when subjects view a head-fixed target. There is need to study how such perturbations, which induce vestibular eye movements, affect vision of head-fixed displays.

Das, Vallabh E.

Image data rate converter having a drum with a fixed head and a rotatable head

A data-rate converter is disclosed comprising a rotatable data-storing drum with at least one fixed read/record head and a rotatable read/record head. The latter is rotatable in a circular path about the drum axis of rotation. The drum is positionable in any one of a plurality of axial positions with respect to the heads, so that at least one drum track is aligned with the fixed head in one drum position and with the rotatable head in another drum position. When a track is aligned with the fixed head, data may be recorded therin or read out therefrom at a rate which is a function of drum rotation, while when aligned with the rotatable head, data may be recorded or read out at a rate which is a function of the rates and directions of rotation of both the drum and the head.

Billingsley, F. C.

An evaluation of flight path formats head-up and head-down

Flight path primary flight display formats were incorporated on head-up and head-down electronic displays and integrated into an Advanced Concepts Flight Simulator. Objective and subjective data were collected while ten airline pilots evaluated the formats by flying an approach and landing task under various ceiling, visibility and wind conditions. Deviations from referenced/commanded airspeed, horizontal track, vertical track and touchdown point were smaller using the head-up display (HUD) format than the head-down display (HDD) format, but not significantly smaller. Subjectively, the pilots overwhelmingly preferred (1) flight path formats over attitude formats used in current aircraft, and (2) the head-up presentation over the head-down, primarily because it eliminated the head-down to head-up transition during low visibility landing approaches. This report describes the simulator, the flight displays, the format evaluation, and the results of the objective and subjective data.

Sexton, George A.

Head-up transition behavior of pilots with and without head-up display in simulated low-visibility approaches

To quantify head-up transition behavior with and without a flightpath type head-up display, eight rated B-727 pilots each flew 31 manual and coupled approaches in a simulator with B-727 dynamics and collimated model board external scene. Data were also obtained on the roll played by the head-up display in the coupled-to-manual transition. Various wind shears, low visibilities, and ceilings were tested along with unexpected misalignment between the runway and head-up display symbology. The symbolic format used was a conformal scene. Every pilot except one stayed head-up, flying with the display after descending below the ceiling. Without the display and as altitude decreased, the number of lookups from the instrument panel decreased and the duration of each one increased. No large differences in mean number or duration of transitions up or down were found during the head-up display runs comparing the no-misalignment with the lateral instrument landing system offset misalignment runs. The head-up display led to fewer transitions after the pilot made a decision to land or execute a missed approach. Without the display, pilots generally waited until they had descended below the ceiling to look outside the first time, but with it several pilots looked down at their panel at relatively high altitudes (if they looked down at all). Manual takeover of control was rapid and smooth both with and without the display which permitted smoother engine power changes.

Haines, R. F.

Effect on head-wind profiles and mean head-wind velocity on landing capacity flying constant-airspeed and constant-groundspeed approaches

A study was conducted to determine the effect of head-wind profiles and mean head-wind velocities on runway landing capacity for airplanes flying constant-airspeed and constant-groundspeed approaches. It was determined that when the wind profiles were encountered with the currently used constant airspeed approach method, the landing capacity was reduced. The severity of these reductions increased as the mean head-wind value of the profile increased. When constant-groundspeed approaches were made in the same wind profiles, there were no losses in landing capacity. In an analysis of mean head winds, it was determined that in a mean head wind of 35 knots, the landing capacity using constant-airspeed approaches was 13% less than for the no wind condition. There were no reductions in landing capacity with constant-groundspeed approaches for mean head winds less than 35 knots. This same result was observed when the separation intervals between airplanes was reduced.

Hastings, E. C., Jr.

Active head rotations and eye-head coordination

It is pointed out that head movements play an important role in gaze. The interaction between eye and head movements involves both their shared role in directing gaze and the compensatory vestibular ocular reflex. The dynamics of head trajectories are discussed, taking into account the use of parameterization to obtain the peak velocity, peak accelerations, the times of these extrema, and the duration of the movement. Attention is given to the main sequence, neck muscle EMG and details of the head-movement trajectory, types of head model accelerations, the latency of eye and head movement in coordinated gaze, gaze latency as a function of various factors, and coordinated gaze types. Clinical examples of gaze-plane analysis are considered along with the instantaneous change of compensatory eye movement (CEM) gain, and aspects of variability.

Zangemeister, W. H.

Rat Cardiovascular Responses to Whole Body Suspension: Head-down and Non-Head-Down Tilt

The rat whole body suspension technique mimics responses seen during exposure to microgravity and was evaluated as a model for cardiovascular responses with two series of experiments. In one series, changes were monitored in chronically catheterized rats during 7 days of Head-Down Tilt (HDT) or Non-Head-Down Tilt (N-HDT) and after several hours of recovery. Elevations of mean arterial (MAP), systolic, and diastolic pressures of approx. 20 % (P less than 0.05) in HDT rats began as early as day 1 and were maintained for the duration of suspension. Pulse pressures were relatively unaffected, but heart rates were elevated approx. 10 %. During postsuspension (2-7 h), most cardiovascular parameters returned to presuspension levels. N-HDT rats exhibited elevations chiefly on days 3 and 7. In the second series, blood pressure was monitored in 1- and 3-day HDT and N-HDT rats to evaluate responses to rapid head-up tilt. MAP, systolic and diastolic pressures, and HR were elevated (P less than 0.05) in HDT and N-HDT rats during head-up tilt after 1 day of suspension, while pulse pressures remained un changed. HDT rats exhibited elevated pretilt MAP and failed to respond to rapid head-up tilt with further increase of MAP on day 3, indicating some degree of deconditioning. The whole body suspended rat may be useful as a model to better understand responses of rats exposed to microgravity.

Musacchia, X. J.

Adapted head- and eye-movement responses to added-head inertia

Adaptation to inertia added to the head was studied in men by mounting masses on a rigidly attached helmet until two- to ten-fold increases of inertia were produced, while an overhead suspension compensated for the weights. The observed changes in the eye and head movement coordination included increased head movement latencies, as well as changes in the eye movement amplitude, and later stabilizing alternate contractions of the neck muscles. Oscillopsia, or continual displacement or instability of the visual world, which is a symptom of a breakdown of space constancy, was prominent and consistent in the perceptual reports of the subjects. Although adaptation resulting from adding inertia to the head occurred much faster than that induced by adding prisms or lenses, it has similar perceptual and motor components that may be objectively studied in detail.

Gauthier, G. M.

Eye and head motion during head turns in spaceflight

Eye-head motion was studied pre-, in- and postflight during single voluntary head turns. A transient increase in vestibulo-ocular reflex (VOR) gain occurred early in the flight, but later trended toward normal. This increased gain was produced by a relative increase in eye counterrotation velocity. Asymmetries in gain with right and left turns also occurred, caused by asymmetries in eye counterrotation velocities. These findings were remarkably similar to those from Soviet primate studies using gaze fixation targets, except the human study trended more rapidly toward normal. These findings differ substantially from those measuring VOR gain by head oscillation, in which no significant changes were found inflight. No visual disturbances were noted in either test condition or in normal activities. These head turn studies are the only ones to date documenting any functional change in VOR in weightlessness.

Thornton, William E.

Rat cardiovascular responses to whole body suspension - Head-down and non-head-down tilt

Two experiments aimed at examining the versatility of the whole body suspension (WBS) system as a ground-based model for cardiovascular effects of microgravity are described. The first experiment studied heart rate and arterial pressure responses in rats during a 7-day period of head-down tilt (HDT) or nonhead-down tilt (NHDT) and after removal from whole body suspension (WBS). Mean arterial (MAP), systolic, and diastolic pressures increased about 20 percent in HDT rats on the fist day, heart rates were elevated about 10 percent. During postsuspension most cardiovascular parameters returned to presuspension levels. The second experiment evaluated responses to rapid head-up tilt in HDT and NHDT rats. It was observed that, while pulse pressures remained unchanged, MAP, systolic and diastolic pressures, and HR were elevated in HDT and NHDT rats during head-up tilt after one day of suspension. The WBS rats are considered to be useful as a model to better understand responses of rats exposed to microgravity.

Musacchia, X. J.

Performance Comparison Between a Head-Worn Display System and a Head-Up Display for Low Visibility Commercial Operations

Research, development, test, and evaluation of flight deck interface technologies is being conducted by NASA to proactively identify, develop, and mature tools, methods, and technologies for improving overall aircraft safety of new and legacy vehicles operating in Next Generation Air Transportation System (NextGen). Under the Vehicle Systems Safety Technologies (VSST) project in the Aviation Safety Program, one specific area of research is the use of small Head-Worn Displays (HWDs) as an equivalent display to a Head-Up Display (HUD). Title 14 of the US Code of Federal Regulations (CFR) 91.175 describes a possible operational credit which can be obtained with airplane equipage of a HUD or an "equivalent" display combined with Enhanced Vision (EV). If successful, a HWD may provide the same safety and operational benefits as current HUD-equipped aircraft but for significantly more aircraft in which HUD installation is neither practical nor possible. A simulation experiment was conducted to evaluate if the HWD, coupled with a head-tracker, can provide an equivalent display to a HUD. Comparative testing was performed in the Research Flight Deck (RFD) Cockpit Motion Facility (CMF) full mission, motion-based simulator at NASA Langley. Twelve airline crews conducted approach and landing, taxi, and departure operations during low visibility operations (1000' Runway Visual Range (RVR), 300' RVR) at Memphis International Airport (Federal Aviation Administration (FAA) identifier: KMEM). The results showed that there were no statistical differences in the crews performance in terms of touchdown and takeoff. Further, there were no statistical differences between the HUD and HWD in pilots' responses to questionnaires.

Arthur, Jarvis J., III

Comparison of susceptibility to motion sickness during rotation at 30 rpm in the earth-horizontal, 10 deg head-up, and 10 deg head-down positions

Normal persons rotated about an earth-horizontal axis vary in their susceptibility to motion sickness. An experimental study was conducted to measure intraindividual differences in susceptibility in 12 subjects when rotated 10 deg head up and 10 deg head down as well as in the horizontal position. Subjects assumed the test-position 60 min prior to rotation, thus providing an opportunity for translocation of body fluids. Physiological and psychological measurements were conducted throughout the experiment. There were no intraindividual differences in susceptibility to motion sickness in the three positions tested, although there were significant differences in vital capacity, demonstrating the expected fluid shifts. It was concluded that, in the sample of subjects tested, short-term effects of fluid shifts greater than those that would be manifested in zero gravity had no definite effect on motion sickness susceptibility.

Graybiel, A.

Field of view effects on a simulated flight task with head-down and head-up sensor imagery displays

Field-of-view (FOV) effects are investigated in simulated flights with sensor imagery appearing on a head-up display (HUD) and a head-down display (HDD). The pilots fly a simulated slalom course and are given information from a sensor image with a 25-, 40-, or 50-deg FOV and no additional information. The factors which most significantly affect performance are thereby identified, and the speed of flying, level of training, and FOV are found to be the most important characteristics. FOV affects performance regardless of the choice of HUD or HDD, and the narrow FOV caused the pilots to fly closer to the obstacles than the wider FOVs. No statistically significant difference between the use of HUD and HDD is identified, but the pilots appear to regard the displays in general as the entire world and not as a 'window on the world'.

Brickner, Michael S.

Orthostatic function during a stand test before and after head-up or head-down bedrest

The effects of head-down or head-up bedrest at -5, +10, +20, or +42 deg (simulating 0, 1/6, 1/3, and 2/3 g, respectively) for 6 hrs on four different days on the orthostatic tolerance were investigated by measuring relevant physiological reactions to orthostatic test taken before and after bedrest sessions. The multivariate analysis of variance statistical analyses indicates that there was no angle effect on any of the cardiovascular parameters monitored during the last 3 min of the stand test, suggesting that partial gravity loads would have no effect on the cardiovascular deconditioning exhibited postflight. There was, however, a significant elevation in the heart rate post-bedrest, and the heart rate increased on standing. Results from the stand test pre- and post-bedrest at -5 deg (but not at +10, +20, and +42 deg) were similar to those observed after space flight.

Lathers, Claire M.

Head-Mounted and Head-Up Display Glossary

One of the problems in head-up and helmet-mounted display (HMD) literature has been a lack of standardization of words and abbreviations. Several different words have been used for the same concept; for example, flight path angle, flight path marker, velocity vector, and total velocity vector all refer to the same thing. In other cases, the same term has been used with two different meanings, such as binocular field-of-view which means the field-of-view visible to both left and right eyes according to some or the field-of-view visible to either the left or right eye or both according to others. Many of the terms used in HMD studies have not been well-defined. We need to have a common language to ensure that system descriptions are communicated. As an example, the term 'stabilized' has been widely used with two meanings. 'Roll-stabilized' has been used to mean a symbol which rotates to indicate the roll or bank of the aircraft. 'World-stabilized' and 'head-stabilized' have both been used to indicate symbols which move to remain fixed with respect to external objects. HMDs present unique symbology problems not found in HUDs. Foremost among these is the issue of maintaining spatial orientation of the symbols. All previous flight displays, round dial instruments, HDDs, and HUDs have been fixed in the cockpit. With the HMD, the flight display can move through a large angle. The coordinates use in transforming from the real-world to the aircraft to the HMD have not been consistently defined. This glossary contains terms relating to optics and vision, displays, and flight information, weapons and aircraft systems. Some definitions, such as Navigation Display, have been added to clarify the definitions for Primary Flight Display and Primary Flight Reference. A list of HUD/HMD related abbreviations is also included.

Newman, Richard L.