Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hard X-rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Next-Generation Hard X-ray Missions: SuperHERO and HEROIX

High-energy X-ray observations have transformed our understanding of astrophysical systems where non-thermal processes dominate, from shock-accelerated particles in supernova remnants to relativistic jets and hot coronae in active galactic nuclei. NuSTAR’s pioneering focusing images of the hard X-ray sky have demonstrated the immense scientific potential of this band, while also highlighting how limited angular resolution constrains our ability to fully characterize complex physical processes in faint extended sources and resolving faint sources in crowded sky regions. In this presentation, I will discuss a pathway to overcome these challenges through NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology. Specifically, I will discuss the SuperHERO hard X-ray telescope to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon flight observing the Crab Nebula, and the High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept to achieve an integrated effective area of 570 cm2 at 30 keV with 5 arcsec HPD angular resolution.

AGN↗

Hard X-rays from Sco X-1

Hard X rays from Sco X-1, discussing high energy excess with large temporal variations

Boldt, E.↗

SuperHERO X-ray Telescope Balloon Mission

The SuperHERO hard X-ray telescope will observe extended sources at unprecedented imaging resolution, revealing the origins of non-thermal emission in extreme astrophysical environments. Employing NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon platform, SuperHERO consists of seven identical, co-aligned telescopes with a combined effective area of 45 cm² at 30 keV. SuperHERO was selected in the APRA 2023 call as a five-year mission, with an inaugural two-day flight scheduled from Fort Sumner, New Mexico, in the fall of 2028. For its initial target, SuperHERO will observe the Crab pulsar wind nebula, localizing hard X-ray emission. Mission development is currently underway, with updates and status to be provided in this presentation.

Nick Thomas↗

High EneRgy Observatory for Imaging X-rays (HEROIX) Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) is a next-generation broadband X-ray space telescope concept under development as a Medium-Class Explorer mission. Building on more than three decades of replicated NiCo shell technology at NASA’s Marshall Space Flight Center, HEROIX will deliver 5 arcsecond half-power-diameter imaging resolution in the hard X-ray band. The observatory will incorporate four co-aligned telescopes with advanced multilayer coatings, extending the bandpass into the hard X-ray regime and providing an integrated effective area of 380 cm² at 30 keV. A suite of focal plane detectors will enable imaging capability throughout its 1–80 keV bandpass. This combination of angular resolution and high-energy coverage will open new windows into non-thermal processes in extreme astrophysical environments. HEROIXwill deliver transformative science, advancing the astrophysics community’s understanding of supernova physics, the X-ray binary population of the Galactic Center, accretion-driven galaxy evolution, and the origin of the Cosmic X-ray Background.

Nick Thomas↗

Supernova 1987A

Supernova 1987A (February 23, 1987) in the Large Magellanic Cloud is the brightest supernova to be observed since SN 1604 AD (Kepler). Detection of a burst of neutrinos indicates that a neutron star was formed. Radioactive decay of about 0.07 solar mass of Co-56 is responsible for the observed optical light as well as hard X-rays and gamma-ray lines. Ultraviolet, optical, and infrared 'light echoes' and soft X-rays provide information on the distribution of circumstellar matter and the evolution of the progenitor star.

Mccray, Richard↗

Changes Found on Run-In and Scuffed Surfaces of Steel Chrome Plate, and Cast Iron

A study was made of run-in and scuffed steel, chrome-plate, and cast-iron surfaces. X-ray and electron diffraction techniques, micro-hardness determinations, and microscopy were used. Surface changes varied and were found to include three classes: chemical reaction, hardening, and crystallite-size alteration. The principal chemical reactions were oxidation and carburization.

IRON, CAST - WEAR RESISTANCE↗

Fundamental Effects of Aging on Creep Properties of Solution-Treated Low-Carbon N-155 Alloy

A method is developed whereby the fundamental mechanisms are investigated by which processing, heat treatment, and chemical composition control the properties of alloys at high temperatures. The method used metallographic examination -- both optical and electronic --studies of x-ray diffraction-line widths, intensities, and lattice parameters, and hardness surveys to evaluate fundamental structural conditions. Mechanical properties at high temperatures are then measured and correlated with these measured structural conditions. In accordance with this method, a study was made of the fundamental mechanism by which aging controlled the short-time creep and rupture properties of solution-treated low-carbon n-155 alloy at 1200 degrees F.

Frey, D N↗

Measurements of Total Hemispherical Emissivity of Several Stably Oxidized Nickel-Titanium Carbide Cemented Hard Metals from 600 F to 1,600 F

The total hemispherical emissivity of several nickel-titanium carbide cemented hard metals have been measured over a temperature range from 600 F to l,600 F. A variety of cemented hard metals were obtained from the Kennametal Corporation. A brief discussion of the apparatus employed and the procedures used for this investigation is included. The results of the tests of specimens in the as-received and polished states indicate a nearly constant emissivity for each material tested over the temperature range considered and only slight differences in emissivity values for the different materials. Values obtained on the stably oxidized specimens range from 0.90 to 0.94 at 6000 F and o.88 to 0.92 at 1,600 F for the as-received specimens and from 0.82 to 0.89 at 600 F and 0.85 to 0.87 at 1,600 F for the polished specimens. The surface analysis of the oxidized materials as obtained by X-ray diffraction methods and metallographic techniques are presented as an aid to reproducing the surface on which these measurements were made.

Wade, William R.↗