Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hard X-rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Next-Generation Hard X-ray Missions: SuperHERO and HEROIX

High-energy X-ray observations have transformed our understanding of astrophysical systems where non-thermal processes dominate, from shock-accelerated particles in supernova remnants to relativistic jets and hot coronae in active galactic nuclei. NuSTAR’s pioneering focusing images of the hard X-ray sky have demonstrated the immense scientific potential of this band, while also highlighting how limited angular resolution constrains our ability to fully characterize complex physical processes in faint extended sources and resolving faint sources in crowded sky regions. In this presentation, I will discuss a pathway to overcome these challenges through NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology. Specifically, I will discuss the SuperHERO hard X-ray telescope to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon flight observing the Crab Nebula, and the High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept to achieve an integrated effective area of 570 cm2 at 30 keV with 5 arcsec HPD angular resolution.

AGN↗

Single-shot hard X-ray spectrometer with uniform spatial and spectral response

We demonstrate a single-shot hard X-ray spectrometer based on small-angle scattering from glassy carbon that is insensitive to XFEL beam-dependent spatial and spectral variations. Comparison with established X-ray Thomson scattering diagnostics using stochastic correlation X-ray spectroscopy demonstrates full-bandwidth coverage with meV-scale spectral resolution, enabling reliable single-shot spectroscopic measurements.

47 OTHER INSTRUMENTATION↗

SuperHERO X-ray Telescope Balloon Mission

The SuperHERO hard X-ray telescope will observe extended sources at unprecedented imaging resolution, revealing the origins of non-thermal emission in extreme astrophysical environments. Employing NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon platform, SuperHERO consists of seven identical, co-aligned telescopes with a combined effective area of 45 cm² at 30 keV. SuperHERO was selected in the APRA 2023 call as a five-year mission, with an inaugural two-day flight scheduled from Fort Sumner, New Mexico, in the fall of 2028. For its initial target, SuperHERO will observe the Crab pulsar wind nebula, localizing hard X-ray emission. Mission development is currently underway, with updates and status to be provided in this presentation.

Nick Thomas↗

High EneRgy Observatory for Imaging X-rays (HEROIX) Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) is a next-generation broadband X-ray space telescope concept under development as a Medium-Class Explorer mission. Building on more than three decades of replicated NiCo shell technology at NASA’s Marshall Space Flight Center, HEROIX will deliver 5 arcsecond half-power-diameter imaging resolution in the hard X-ray band. The observatory will incorporate four co-aligned telescopes with advanced multilayer coatings, extending the bandpass into the hard X-ray regime and providing an integrated effective area of 380 cm² at 30 keV. A suite of focal plane detectors will enable imaging capability throughout its 1–80 keV bandpass. This combination of angular resolution and high-energy coverage will open new windows into non-thermal processes in extreme astrophysical environments. HEROIXwill deliver transformative science, advancing the astrophysics community’s understanding of supernova physics, the X-ray binary population of the Galactic Center, accretion-driven galaxy evolution, and the origin of the Cosmic X-ray Background.

Nick Thomas↗

Fe-single atom catalysts facilitate fast electron transfer with MoS 2 /SnS 2 cathodes in lithium–sulfur batteries

Lithium–sulfur batteries (LSBs) emerge as promising next-generation energy storage systems offering cost-effectiveness, environmental friendliness, and high theoretical energy density. The practical implementation of LSBs faces significant hindrances due to the shuttle effect and sluggish redox reactions. To address these challenges, single-atom catalyst (SAC) based combination materials from d-block elements can offer increased active catalytic sites, rapid charge transfer, accelerated electron migration, and fast sulfur redox conversion kinetics of lithium polysulfides (LiPSs). In this study, we fabricated three different LSB cathodes: pure S, S@MoS 2 /SnS 2 , and S@Fe–MoS 2 /SnS 2 . These cathodes were then used to explore the cycle life, capacity, rate capability, and redox kinetic reactions of LiPSs while assessing the influence of Fe-SACs on their performance. As a result, LSBs with S@Fe–MoS 2 /SnS 2 cathodes demonstrate an extended cycle life of 1000 cycles at a C-rate of 0.2C, maintaining a capacity close to 500 mA h g −1 , the highest initial discharge capacity of 1622 mA h g −1 and 1066 mA h g −1 at 0.05C and 0.2C, and excellent rate capabilities of 708 mA h g −1 and 558 mA h g −1 at 1C and 2C, respectively. The synergistic effect of the Fe-SAC-based combination cathode (S@Fe–MoS 2 /SnS 2 ) creates plentiful adsorptive and highly active catalytic sites, resulting in substantially enhanced capacity for adsorbing soluble long-chain LiPSs. This facilitates ultra-fast redox kinetics, surpassing the performance of the S@MoS 2 /SnS 2 and pure S cathodes. In the ex situ analysis, results from powder X-ray diffraction (XRD) to observe the new phase, soft X-ray absorption spectroscopy (XAS) to investigate the electronic structure, and hard X-ray photoelectron microscopy (HAXPES) with different energies (900 eV, 2000 eV, and 6000 eV) to track the chemical-state evolution of Fe-SACs in MoS 2 /SnS 2 cathodes displayed notable electrochemical reversibility involving S 8 ⇄ LiPSs ⇄ Li 2 S conversion even after 1000 cycles. Additionally, in situ, operando Raman analysis can unveil a novel catalytic mechanism of Fe-SACs in MoS 2 /SnS 2 “facilitating rapid electron transfer” during the discharge and charge processes of LSBs involving the conversion of S 8 ⇄ long-chain LiPSs ⇄ Li 2 S 2 /Li 2 S. This study elucidates the working mechanism of Fe-SAC cathodes, offering insights into overcoming the shuttle effect and facilitating sulfur redox kinetics to advance commercial LSBs.

36 MATERIALS SCIENCE↗

High-resolution bandpass x-ray imaging with crystal reflectors: Overcoming geometric aberrations

The imaging problem of a specular reflector is revisited. Retaining terms through the second order in the reflector surface expansion, we derive the form of the aberration-limiting aperture for arbitrary magnification, assuming no bandwidth limitations. A permissible relative aperture size of the reflector is limited by a set relative aberration tolerance and scales with the tangent of the central glancing angle of incidence. These limiting aberrations become practically insignificant near backscattering. The results extend to x-ray diffracting crystals in symmetric Bragg geometry shaped as an ellipsoid of revolution. This geometry permits polychromatic imaging for hard x-rays over a bandwidth defined by the accepted range of Bragg angles, thereby suppressing aberrations of higher orders. We assess ellipsoidal crystal imagers using ray tracing simulations for two high-magnification designs with Bragg angles far from and close to backscattering. Finally, in both cases, the ellipsoidal crystals produce images of higher quality compared to those formed by equivalent toroidal crystal imagers.

Bragg reflection↗

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

Impact of the Annealing Temperature on the Local Se Distribution and Optical Properties in CdSexTe1-x Solar Cells by Multimodal X-ray Microscopy

The introduction of Se in CdTe solar-cell absorbers has led to multiple beneficial effects in the devices, including an increased short-circuit current and an extended charge-carrier lifetime. A critical manufacturing step of CdSexTe1-x solar cells is CdCl2 annealing at high temperatures, during which Se diffuses through the absorber layer. Understanding the local Se distribution in the absorber and its impact on optical properties of the material is key for the further development of this thin-film solar cell technology. In a multimodal x-ray scanning microscopy approach, we investigated the impact of the annealing temperature of CdSexTe1-x solar cells on the Se distribution and on optical characteristics of the material. For this purpose, we exploited an upgraded x-ray excited optical luminescence (XEOL) detection unit that enables simultaneous spectrally and temporally resolved XEOL mapping at synchrotron facilities that are ideal for studying thin-film solar-cell materials with hard x-rays featuring high penetration depth and lateral resolution.

14 SOLAR ENERGY↗

Establishing the Stability of Cross-Linked Poly(ethylene oxide) Blended with Poly(pentyl malonate) against Lithium Metal Anodes

This work focuses on an electrolyte obtained by infusing linear poly(pentyl malonate) (PPM) chains into cross-linked poly(ethylene oxide) (PEO). A lithium salt is added to enable ion transport. Obtaining this electrolyte is only possible because PPM is miscible with PEO irrespective of salt concentration. The properties of this electrolyte are compared against two benchmarks: an electrolyte obtained by infusing linear PEO into cross-linked PEO and cross-linked PEO with no added linear polymer. Measurements of storage moduli and ion transport efficacies are found to be similar across the three electrolytes, suggesting similar stability behavior against lithium metal anodes, based on current theoretical models. Instead, the PPM infused electrolyte outperforms the other two electrolytes. In the cycling tests, the current supported by the PPM infused electrolyte was a factor of 20 higher than that of the PEO infused electrolyte and a factor of 4 higher than that of the cross-linked PEO electrolyte. In the unidirectional plating experiments, the other two electrolytes fail after about 4 h or less, while the PPM containing electrolyte did not fail during the 140 h testing period. Insight into the nature of failure modes was obtained using synchrotron hard X-ray microtomography.

Gido, Lily [University of California, Berkeley]↗

Real-space imaging of the electron-pair density hole in molecular Auger–Meitner decay

Electrons in matter can rearrange extremely quickly under external perturbations, underpinning subsequent structural and chemical transformations. Coulomb interactions between neighbouring electrons often shape this response, giving rise to correlated motion and strongly affecting the distribution of electrons in the system. Here we show that non-resonant hard X-ray scattering can directly access changes in the radial electron-pair density during the rapid rearrangement of core and valence electrons. We do this by studying sulfur hexafluoride molecules undergoing Auger–Meitner decay. We exploit a second-order interaction between the X-ray photons and the molecules to trigger and probe the decay dynamics with a single pulse, capturing the electron loss and redistribution before the molecules dissociate. The experiment shows that changes in electron-pair densities can be isolated and measured on ultrafast timescales, providing insight into the real-space evolution of highly excited and short-lived electronic states.

Simmermacher, Mats [University of Oxford (United K↗

Multiscale and multidimensional modeling of particle acceleration and transport in solar flares

Multi-messenger, multi-viewpoint, and time-resolved observations of solar flares are now providing unprecedented constraints on particle acceleration sites, energy conversion, and energy transport. The interpretation of current observations, including microwave imaging spectroscopy from EOVSA, hard x-ray (HXR) imaging from Solar Orbiter/STIX, gamma-ray diagnostics from Fermi, and in situ measurements from Parker Solar Probe and Solar Orbiter, collectively demands modeling frameworks that go beyond traditional spatially unresolved, one-zone models or single-mechanism descriptions. This review surveys multiscale and multidimensional modeling approaches, including kinetic, magnetohydrodynamic (MHD), and macroscopic particle models, that are being developed to meet the need. Kinetic simulations reveal that three-dimensional (3D) effects, including field-line chaos and self-generated turbulence, are essential for sustained power-law particle acceleration. MHD simulations now capture flux-rope eruptions, plasmoid-unstable current sheets, and turbulent flare regions in realistic magnetic topologies. Macroscopic models coupling MHD with energetic-particle models produce spatially resolved electron distributions and synthetic HXR and microwave emissions for direct comparison with observations. Despite these advances, outstanding challenges remain in bridging kinetic and global scales, improving MHD simulations and macroscopic particle models, and achieving quantitative model-observation closure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Light-tight Skipper-CCDs for X-Ray Detection in Space

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising technology for space-based X-ray astronomy. In this scenario, optical and near-infrared photons may saturate the sensor, distorting the reconstructed signal. We present a light-tight shield for skipper-CCDs to suppress optical backgrounds while preserving X-ray detection efficiency. We deposited thin aluminum layers on the CCD surface using an e-beam evaporator and evaluated their blinding performance across wavelengths from 650 to 1000 nm using a monochromator, as well as the X-ray transmission using an 55 Fe source. We find that 50 and 100 nm layers provide >99.6% light suppression, with no efficiency loss for 5.9 and 6.4 keV X-rays. In addition, we used Geant4 simulations to extend these results to a broader energy range and quantify the efficiency loss for different aluminum thicknesses. Results show that thin aluminum coatings are an effective, low-cost solution for optical suppression in skipper-CCDs intended for X-ray detection and space instrumentation.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron beam irradiation effects on bulk metals: a comparative study of polycrystalline versus single-crystalline structures

This study investigates the effects of electron beam (e-beam) irradiation on the mechanical and structural properties of eight bulk metallic samples, comprising both polycrystalline (PC) and single-crystalline (SC) forms of Ni, Cr, V, and Ti. These metals were evaluated as potential candidates for beam exit windows in high-power (MW-class) particle accelerators. The primary objective is to identify metals capable of withstanding the conditions of high-power/MW-class e-beam accelerators and serve effectively as exit windows. Selection criteria were based on each metal’s intrinsic properties, power dissipation capability, and irradiation-induced changes in mechanical behavior, including hardness, elastic modulus, and defect density. Comprehensive characterization was conducted using field-emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM–EDS), X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), selected area electron diffraction (SAED), and nanoindentation, performed both before and after exposure to a ~¿66 kGy dose from a 10 MeV e-beam accelerator. Results revealed that e-beam irradiation induced hardening in PC Ni, whereas PC Ti, commonly used in beam exit windows, exhibited softening. The observed softening in PC Ti is attributed to grain coarsening, elongation, and the formation of twins and twin boundaries, in contrast to the smaller, compressed grains in the pristine (Pr) PC Ti samples, consistent with the Hall–Petch relationship. The stresses due to twinning are small and insignificant in influencing the overall hardening of the PC Ti irradiated sample when compared to the stresses due to the dislocation density. Conversely, SC Ti samples exhibited irradiation-induced hardening. The SC Ti irradiated samples developed additional irradiation-induced modifications in crystallographic texture of (100), (101), (110), (200), (112), (004), and (211) as evidenced from the XRD results, which could probably explain the hardening effect that is caused by irradiation.

36 MATERIALS SCIENCE↗

Mechanical Behavior of Neutron Irradiated Refractory Multi-Principal Element Alloys Processed via Spark Plasma Sintering

The search for advanced materials capable of withstanding the extreme conditions of Generation IV reactors is a critical area in materials science research. These reactors operate under severe environments, including high temperatures, corrosion, stress, and irradiation damage. Consequently, there is a need for innovative alloy systems to ensure the reliability and longevity of proposed Generation IV reactor components. Refractory multi-principal-element alloys (RMPEA) have emerged as a promising candidate due to their exceptional properties. These alloys, characterized by their composition of multiple principal elements in near-equiatomic ratios, exhibit superior resistance to irradiation damage, reduced void swelling, enhanced microstructural stability, and minimal irradiation-induced hardening. While initial studies on RMPEAs have shown promising results, most research has been limited to thin films, nanocrystalline microstructures, and ion irradiation, which do not accurately represent the behavior of bulk materials. To address this gap, our research focused on the neutron irradiation of bulk RMPEAs. We aim to conduct comprehensive post-irradiation examinations (PIE) of RMPEAs irradiated at the Advanced Test Reactor at Idaho National Laboratory. The RMPEAs were synthesized using spark plasma sintering (SPS) with mechanically alloyed metallurgical powder. The RMPEA specimens are a MoNbTi alloy system with additions of -Zr, and -ZrV. Furthermore, PIE consisted of mechanical testing and advanced materials characterization. The mechanical testing consisted of sub-sized tensile testing, micro- and nano- indentation. Microstructural characterization included scanning electron microscopy and transmission electron microscopy. Mechanical testing coupled with advanced microscopy techniques provides insight into phase morphology and its effects on the mechanical properties of the RMPEA specimens. The results indicate that both pristine and irradiated RMPEA specimens exhibited brittle behavior during tensile testing, which can be attributed to their heterogeneous microstructure. The SPS manufacturing process did not include any post treatment, which resulted in a heterogeneous microstructure. Energy-dispersive X-ray spectroscopy revealed the presence of intermetallic such as laves phases within the microstructure. Specifically, Ti-rich precipitates were observed in the MoNbTi specimen, while Mo-rich precipitates were found in the MoNbTiZrV specimen. Nano-hardness testing of pristine samples showed that the laves phases exhibited higher hardness values compared to the matrix phase, suggesting that precipitate hardening is likely the dominant hardening mechanism in these specimens. The results from this work will be used to build a finite element model to predict mechanical behavior of future MPEA compositions. Thus, enabling for a streamlined approach to developing novel MPEAs for the nuclear industry.

36 - MATERIALS SCIENCE↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

High hardness and oxidation-resistant Cr-containing medium entropy ZrTaW diboride

This study reports the successful synthesis of a Cr-containing (Zr 0.30 Ta 0.34 Cr 0.06 W 0.30 )B 2 medium-entropy boride (MEB) via an in-situ reactive borothermal reduction route from oxide precursors. High-energy ball milling was employed to homogenize the precursor mixture prior to reactive densification. X-ray diffraction confirmed the formation of a predominantly AlB₂-type hexagonal diboride structure together with a secondary (W X , M 1-X )B monoboride phase. Microstructural characterization revealed compositional heterogeneity and localized W-rich regions associated with the secondary phase. The synthesized medium-entropy boride exhibited enhanced mechanical properties, which are attributed to lattice distortion and solid-solution strengthening effects. Thermogravimetric analysis revealed complex multistage oxidation behavior, and the oxidation resistance was compared with conventional ultra-high-temperature diborides. The results demonstrate the strong relationship between oxide-derived processing, compositional complexity, phase evolution, and oxidation behavior, highlighting the potential of medium-entropy borides for high-temperature structural applications

36 MATERIALS SCIENCE↗