Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hanford tank waste treatment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation into Na and Cs activity coefficients in high salt solutions to support Cs removal in Hanford tank waste

The treatment of Hanford tank waste is one of the most technically challenging environmental cleanup activities for the U.S. Department of Energy to date. To expedite the processing of liquid waste stored in underground tanks in southeastern Washington state, it is necessary to remove the significant dose contributor, 137 Cs. Toward this effort, ion exchange with crystalline silicotitanate (CST) has been employed as part of the Tank Side Cesium Removal system. The model used to predict Cs exchange onto CST was developed using activity coefficients calculated from the Bromley equation. A series of batch contact tests that varied in [Na] were conducted to look at the impact of Na concentration on Cs distribution. Experimental distribution ratios ( K d ) were compared to the distribution ratios predicted using three different activity coefficient models: (1) commercially available HSC software, (2) the Bromley equation, and (3) a simplified approach adapted from Marcos-Arroyo et al. Ultimately, the Bromley method underpredicted the effect of ionic strength on the Na activity coefficient ( γ Na+ ), HSC overestimated the impact of ionic strength on the expected performance due to the Cs activity coefficient ( γ Cs+ ), but the simplified approach predicted the experimental K d values quite well in a binary matrix. In conclusion, expansion of this approach in complex matrices is necessary for application to Hanford tank waste.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A History of Hanford Tank Waste, Implications for Waste Treatment and Disposal

More than 40 years of plutonium processing have left almost 56 million gallons of mixed radioactive waste sequestered in 177 underground tanks on the Hanford Site. Three different processing technologies were employed for plutonium purification in addition to uranium scavenging and fission product removal from the tank waste. All of these chemical processes have contributed to a complex waste stream that varies from tank to tank that presents downstream processing challenges to render the waste into a safe form for long-term storage. The current disposition pathway for Hanford tank waste is vitrification. To maximize waste loading and minimize the number of high-level waste canisters stored in a geologic repository, pretreatment of the waste is required. Both pretreatment and vitrification operations are impacted by the waste composition.

Separations, filtration, ion exchange↗

Review of Mercury in the SRS Tank Waste Storage and Treatment Processes for Applicability to Hanford Waste Processing

The Savannah River Site (SRS) and Hanford produced large quantities of plutonium and other radioisotopes. The separations processes recovered plutonium and produced large quantities of High- Level Waste (HLW) that accumulated at each site in large, underground storage tanks. SRS has been retrieving the stored HLW, pretreating the waste for immobilization, and immobilizing the waste in glass or grout waste forms since the mid-1990s. Treatment of the waste at Hanford is expected to start in the early 2020s. Mercury is present in both the SRS and Hanford tank waste. SRS has recently completed an evaluation of mercury speciation throughout the tank waste treatment and immobilization flowsheet. This study was reviewed to determine what information from the study can be applied to the Hanford tank waste treatment program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance-based simulants for Hanford radioactive waste treatment process testing

Radioactive wastes from nuclear fuel processing are stored in large underground storage tanks at the Hanford Nuclear Reservation. Treatment and remediation require that waste feed from the storage tanks be delivered to the Hanford Tank Waste Treatment and Immobilization Plant continually for the duration of the treatment mission. Furthermore, the complex physical and chemical processes required for this mission, the significant scale, and the hazardous nature of the waste necessitate the use of simulants in process testing. A new class of simulants, “performance-based simulants,” has been developed to match the process performance of the simulant to actual waste performance data.

Hanford tank waste treatment↗

Considerations on Managing Flowsheet and Technology for DFLAW Production

This report evaluates best practices for flowsheet and technology (F&T) management and makes recommendations for Hanford tank waste treatment operations initially for Direct Feed Low Activity Waste (DFLAW). Establishing practicing F&T management operations prior to hot commissioning the Hanford Waste Treatment Plant is desirable to ensure focused F&T leadership and F&T capabilities and competencies are immediately ready to sustain DFLAW production operations. Management of F&T is characterized by the five programmatic elements important to sustained operations and leads to recommendations for Hanford tank waste treatment operations:

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY22 Development of Improved Grout Waste Forms for Supplemental Low Activity Waste Treatment

About 54 to 56 million gallons of radioactive mixed waste is currently stored in underground tanks at the United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. This waste will be separated into low- and high activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products for subsequent disposal. The ILAW product will be disposed of in an engineered facility at the Hanford site while the IHLW product is designed for acceptance into a national deep geological disposal facility for high level nuclear waste. Treatment of the tank waste will take place in the Hanford Tank Waste Treatment and Immobilization Plant (WTP), which is under construction. However, since the WTP Low Activity Waste (LAW) Vitrification Facility was not designed to process the entire inventory of Hanford LAW, up to half of the retrieved Hanford LAW will require supplemental immobilization. Immobilizing LAW in a cementitious waste form known as Cast Stone has been investigated as a possible candidate supplemental immobilization technology

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology and Innovation Roadmap

This Technology and Innovation Roadmap outlines the Hanford Tank Waste Operations & Closure, LLC (H2C) strategic approach for advancing the Hanford Tank Waste Treatment Mission (HTWTM) through technology development. Our focus is on addressing technology needs that address risks, enhance efficiency, ensure worker safety, and uphold environmental standards. This Roadmap identifies key technology initiatives essential for the successful completion of the Hanford Site tank waste cleanup. Updated annually, it incorporates insights from the U.S. Department of Energy (DOE), the Integrated Tank Disposition Contractor (ITDC) H2C, recognized national lab experts, and fieldwork specialists. The Roadmap includes approximately 100 technology elements, each detailed in Technology Element Description Summaries (TEDS) and summarized in catalog sheets. These elements are crucial for aligning technology development activities with mission objectives across the HTWTM. With the initiation of the Direct-Feed Low-Activity Waste (DFLAW) program and the operation of the Tank Side Cesium Removal (TSCR) system, our focus now shifts to the support of scaled up production in East Area; applying similar and exploring new treatment alternatives to West Area Tank Waste; and advancing retrieval, delivery and treatment technologies for waste managed as high-level waste (HLW) across the Hanford tank farms. This transition is reflected in the technology and maturation (TM&E) charts, which highlight the evolving technology priorities. This document serves as a guide for navigating the challenges and opportunities in technology development at the Hanford Site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the Sulfur-Saturated Melt Versions of the HFG1 Study Glasses

The U.S. Department of Energy (DOE) is responsible for building the Hanford Tank Waste Treatment and Immobilization Plant (WTP) at the Hanford Site in Washington to remediate 55 million gallons of radioactive waste that is temporarily stored in 177 underground tanks. The Office of River Protection (ORP) has requested that the Savannah River National Laboratory (SRNL) contribute to current glass studies to support successful startup of the WTP, due to SRNL’s recognized capabilities and expertise for glass waste form development. As part of this effort, the Pacific Northwest National Laboratory (PNNL) is developing, batching, and fabricating simulated high-level waste (HLW) glasses to generate the associated property data needed to validate or identify areas of potential characterization improvements in the current glass property/ composition models. Currently, the models cover only a small fraction of the waste compositions projected in the Hanford tank farm; therefore, the models must be expanded to include high fluoride compositions to successfully complete the WTP mission. SRNL support of this work is defined in the Task Technical and Quality Assurance Plan (TTQAP). This report provides results from the chemical analyses of a series of sulfur-saturated melt (SSM) versions of simulated nuclear waste glasses fabricated at PNNL. The glasses were selected as part of a broader study of the influence of glass composition on chemical durability, sulfur retention, and other properties. The glasses were designated the High Fluoride Glasses-1 (HLG1).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Product Consistency Test Results for the HFG1 Glasses

The U.S. Department of Energy (DOE) is responsible for building the Hanford Tank Waste Treatment and Immobilization Plant (WTP) at the Hanford site in Washington to remediate 55 million gallons of radioactive waste that is temporarily stored in 177 underground tanks. The Office of River Protection (ORP) has requested that the Savannah River National Laboratory (SRNL) contribute in areas of recognized capabilities and expertise for glass waste form development to support successful startup of the WTP. As part of this effort, the Pacific Northwest National Laboratory (PNNL) is developing, batching, and fabricating simulated high-level waste (HLW) glasses to generate the associated property data needed to validate or identify areas of potential characterization improvement in the current glass property/composition models. Currently, the models cover only a small fraction of the waste compositions projected in the Hanford tank farm; therefore, the models must be expanded to include high fluoride compositions to successfully complete the WTP mission. SRNL support of this work is defined in the Task Technical and Quality Assurance Plan (TTQAP). This report provides the results of the Product Consistency Test (PCT) leachates from the High Fluoride Glasses-1 (HFG1), a series of simulated nuclear waste glasses fabricated at PNNL. The series included quenched (Q) and canister-centerline cooled (CCC) versions of the glasses. The glasses were selected as part of a broader study of the influence of glass composition on chemical durability, sulfur retention, and other properties. These data will be used to validate or identify areas of potential characterization improvements in the current glass property/composition models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zero Valent Iron for Reductive Removal of Technetium-99 from Aqueous Sulfate Solutions - 20347

This research investigates the reductive removal of technetium-99 ({sup 99}Tc) by zero valent iron (ZVI) from low activity waste (LAW) off-gas condensate simulant as a secondary treatment after recovery from vitrification planned at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Due to its high volatility, only a fraction of Tc{sup (VII)} will be incorporated into glass waste forms. Volatilized Tc will be captured by an off-gas treatment system with current plans to recycle off-gas condensate back to the vitrification facility. The scheme with off-gas recycling will increase Tc loading in the glass waste, but will also increase the concentrations of sulfate, halides, and other problematic constituents impeding overall LAW processing and increasing volume of the glass product. This study focuses on Tc{sup (VII)} removal by ZVI as a feasible pathway to minimize off-gas condensate recycling, which may result in a reduction in the volumes of LAW waste to be immobilized and subsequent cost savings. ZVI is an established treatment agent for redox-active contaminants such as trichloroethylene, nitrate, arsenic, chromium, phenol, and others. It is a commercially available and cost-effective material. Our previous experiments showed that ZVI is very efficient for the reductive removal of {sup 99}Tc. In this work we studied ZVI oxidation under aerobic conditions at pH 7 with 0.1 M Na{sub 2}SO{sub 4} solution (ionic strength, IS, 0.3 M) in the presence and absence of {sup 99}Tc. The concentration of {sup 99}Tc and the changes in pH, dissolved oxygen (DO), and oxidation-reduction potential (ORP) of the simulated solutions were monitored over 8 days. The formation of iron oxide phases was probed by X-ray diffraction (XRD). Obtained results suggest that ZVI contact time with {sup 99}Tc containing solutions for 6 hours resulted in nearly complete removal of {sup 99}Tc from the aqueous phase. XRD analysis showed that the oxidation of ZVI is rapid with formation of magnetite (Fe{sub 3}O{sub 4}) with minor percentage of goethite and maghemite. This work is a part of a larger set of studies investigating the feasibility of {sup 99}Tc reductive removal from the LAW off-gas condensate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Project Development of an Electrochemical Denitration and Caustic Generation System for HLW Pretreatment at Hanford - 26350

An engineering-scale electrochemical processing skid is proposed to perform the denitration of Hanford tank waste, which would help to mitigate a key process concern with the direct feed processing of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The reduction of nitrates and organic compounds in the waste feed will directly reduce hazardous NOx and ammonia gases generated during the vitrification process, which in turn will aid in addressing potential regulatory and safety challenges associated with processing large volumes of tank waste. This paper highlights the past legacy work, project layout, accomplishments from Phase 1 and research and development envisioned for Phase 2. An innovative electrochemical denitration and caustic generation (EDCGe) process was demonstrated for the pretreatment of tank waste at the Savannah River Site (SRS) in the early 2000s. The denitration electrolyzer, off-gas abatement system, and caustic generator electrolyzer are being developed with the intent that the denitration electrolyzer will convert nitrate and nitrite anions to nitrogen gas while also yielding other gaseous byproducts, which may include N2O, NH3, VOCs, and H2. The gaseous byproducts will be managed via a tandem off-gas catalyst-bed treatment system. The caustic generation electrolyzer will recycle NaOH from the feed to produce a clean caustic stream for use within the batching tanks at Hanford, aiding in the preparation of waste for WTP. The reduction in hazardous emissions and improved waste treatment processes provides a robust solution for nuclear waste management, contributing to environmental safety and regulatory compliance. The EDCGe technology is being adapted, modified, and updated for the preparation of the Direct Feed-High Level Waste (DF-HLW) flowsheet at Hanford. Phase 1 demonstrated a bench-scale proof-of-concept for reactions involving the denitration electrolyzer and gas phase abatement of ammonia. The electrochemical technology is drawing on the scientific outcomes that were reported in the legacy work. The results from Phase 1 demonstrated the viability of the EDCGe system in reducing the nitrogen species of simple non-radioactive waste simulants. Commercially available alloys used as electrode materials and membranes are being studied for the denitration and caustic generation electrolyzers. The continuation of this project holds promise for broader applications, such as energy-efficient ammonia production, and contributes significant advancements in nuclear waste management. Additional material discovery has been investigated into ceramic Na super ion conductive (NaSICON) materials and off-gas abatement catalyst discovery. NaSICON is of interest for selective transport of Na within the electrolyzers to make a clean caustic stream. Future integration and optimization efforts, informed by Phase 1 results and ongoing research, will continue to drive advancements in nuclear waste management technology. The technology developed for the EDCGe treatment of tank waste will also have broader potential to inform other fields, such as energy-efficient ammonia production, as well as ammonia abatement catalysis through the lessons learned in electrochemical nitrate reduction. The applications and benefits of this research extend beyond Hanford and the Savannah River Site, supported by a collaborative team of scientists and engineers from national labs, academia, and industry, ensuring a comprehensive approach to solving complex waste treatment challenges. The team is leveraging advanced electrochemical technologies, machine learning, novel catalysts tailored for gaseous nitrogen species, and cutting-edge reactor systems to enhance the process efficiency and effectiveness of the denitration process.

Rodene, Dylan [Savannah River National Laboratory ↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (K d ) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this K d corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137 Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137 Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation (Rev.1)

The Hanford Tank Waste Treatment and Immobilization Plant Low Activity Waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of discovering that sampling locations do not meet the qualification criteria on the full-scale stacks. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. For this analysis, the range of qualified flow rates listed is conservatively based on the average DV through 6 DV for LV-S1, LV-S2, and LV-C2, and 1/3 DV to 3 DV for LV-S3. Table S1 lists the operating flow rates along with the conservative lower and upper qualified stack flow rates for each of the LAW facility stacks. For each stack, the operating flow is below the upper qualified stack.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Product Consistency Test Results for the LAW Phase 5 Glasses

This report provides the results of the Vapor Hydration Test solutions and the Product Consistency Test leachates from the Low-Activity Waste Phase 5 glasses, a series of simulated nuclear waste glasses fabricated at the Pacific Northwest National Laboratory. The series included quenched and canister-centerline cooled versions of the glasses. These data will be used in the development of enhanced property/composition models for waste glass vitrification at Hanford. Several of the blanks had detectable amounts of sodium and/or silicon. The measured concentrations (mg/L) of boron, sodium, and silicon for the low-activity test reference material glass included with the Product Consistency Tests were much lower than the expected low-activity test reference material test results. A review of the Product Consistency Test data indicated that there was generally little difference between the normalized values based on targeted or measured glass composition. Heat treatment had various impacts on the normalized concentration values. Most of the glasses had NC B , NC Na , and NC Si values that were greater than the Hanford Tank Waste Treatment and Immobilization Plant low-activity waste constraint of 4 g/L. The release rates for boron, sodium, and silicon were highly correlated for the study glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗