Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hamming Window”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution

We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.

Computer simulation↗

Short time Fourier analysis of the electromyogram - Fast movements and constant contraction

Short-time Fourier analysis was applied to surface electromyograms (EMG) recorded during rapid movements, and during isometric contractions at constant forces. A portion of the data to be transformed by multiplying the signal by a Hamming window was selected, and then the discrete Fourier transform was computed. Shifting the window along the data record, a new spectrum was computed each 10 ms. The transformed data were displayed in spectograms or 'voiceprints'. This short-time technique made it possible to see time-dependencies in the EMG that are normally averaged in the Fourier analysis of these signals. Spectra of EMGs during isometric contractions at constant force vary in the short (10-20 ms) term. Short-time spectra from EMGs recorded during rapid movements were much less variable. The windowing technique picked out the typical 'three-burst pattern' in EMG's from both wrist and head movements. Spectra during the bursts were more consistent than those during isometric contractions. Furthermore, there was a consistent shift in spectral statistics in the course of the three bursts. Both the center frequency and the variance of the spectral energy distribution grew from the first burst to the second burst in the same muscle. The analogy between EMGs and speech signals is extended to argue for future applicability of short-time spectral analysis of EMG.

Hannaford, Blake↗

Qualitative Features Extraction from Sensor Data using Short-time Fourier Transform

The information gathered from sensors is used to determine the health of a sensor. Once a normal mode of operation is established any deviation from the normal behavior indicates a change. This change may be due to a malfunction of the sensor(s) or the system (or process). The step-up and step-down features, as well as sensor disturbances are assumed to be exponential. An RC network is used to model the main process, which is defined by a step-up (charging), drift, and step-down (discharging). The sensor disturbances and spike are added while the system is in drift. The system runs for a period of at least three time-constants of the main process every time a process feature occurs (e.g. step change). The Short-Time Fourier Transform of the Signal is taken using the Hamming window. Three window widths are used. The DC value is removed from the windowed data prior to taking the FFT. The resulting three dimensional spectral plots provide good time frequency resolution. The results indicate distinct shapes corresponding to each process.

Amini, Abolfazl M.↗

Non-Stationary Power System Forced Oscillation Analysis using Synchrosqueezing Transform

Non-stationary forced oscillations (FOs) have been observed in power system operations. However, most detection methods assume that the frequency of FOs is stationary. In this paper, we present a methodology for the analysis of nonstationary FOs. Firstly, Fourier synchrosqueezing transform (FSST) is used to provide a concentrated time-frequency representation of the signals that allows identification and retrieval of non-stationary signal components. To continue, the Dissipating Energy Flow (DEF) method is applied to the extracted components to locate the source of forced oscillations. The methodology is tested using simulated as well as real PMU data. In conclusion, the results show that the proposed FSST-based signal decomposition provides a systematic framework for the application of DEF Method to non-stationary FOs.

42 ENGINEERING↗

Effects of signal analysis parameters and noise removal on measured aircraft spectra

Special techniques must be applied when analyzing acoustic noise data from nonstationary sources such as aircraft flyover measurements. Since the Fourier transform is time dependent, the noise signal is divided into short time segments by introducing a window function so that the spectral characteristics remain reasonably stationary. Reducing the window width reduces the frequency resolution while increasing the window duration can lead to spectral smearing. A trade-off must be made between time resolution and frequency resolution. The effects of varying the window duration on narrow-band acoustic spectra and thus the frequency bin width are addressed in this study. The influence of window functions (rectangular, Hamming, etc.) are also investigated. Both a tonal noise source, XV-15 aircraft in the airplane mode, and a broadband noise source, a F-18 aircraft, are considered. When dealing with flight test data, not only is the signal nonstationary, often it is contaminated by both ambient background noise and internal noise generated by the data acquisition system and power generators. Since generator noise is highly tonal, this can be particularly troublesome when computing tone-corrected perceived noise level (PNLT). A scheme is presented in this paper to eliminate unwanted background and internal noise.

Kelly, Jeffrey J.↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Mechanism of Quantum Speedup in Novel Population Transfer Protocol for Binary Optimization Problems

We consider a novel quantum population transfer protocol to solve binary optimization problems that exploits quantum many-body dynamics in the delocalized regime. Hard optimization problems are characterized by energy landscape with a large number of local minima separated by large Hamming distances which scale with the problem size. This landscape gives rise to an interesting computational primitive: given an initial bit-string, we are to produce other bit-strings within certain narrow range of energies around the initial state. We consider a specific model we call "impurity band": a system of n qubits in a transverse field, where a number of bitstrings $M<<2^n$ selected at random are assigned random energies distributed in a narrow window of width $W<<1$ around the mean energy $-n$. We demonstrate the existence of the many-body delocalized regime in this model when the spectrum of the model splits into many-body minibands, and a typical eigenstate wave function is a superposition of peaks centered at a large number of local minima. The typical width of the minibands in energy determines the efficiency of the population transfer protocol. We demonstrate theoretically that the population transfer protocol achieves Grover type speedup in the unstructured impurity band model.

Kechedzhi, Kostyantyn↗

A New Definition for Ground Control

LandForm(R) VisualFlight(R) blends the power of a geographic information system with the speed of a flight simulator to transform a user's desktop computer into a "virtual cockpit." The software product, which is fully compatible with all Microsoft(R) Windows(R) operating systems, provides distributed, real-time three-dimensional flight visualization over a host of networks. From a desktop, a user can immediately obtain a cockpit view, a chase-plane view, or an airborne tracker view. A customizable display also allows the user to overlay various flight parameters, including latitude, longitude, altitude, pitch, roll, and heading information. Rapid Imaging Software sought assistance from NASA, and the VisualFlight technology came to fruition under a Phase II SBIR contract with Johnson Space Center in 1998. Three years later, on December 13, 2001, Ken Ham successfully flew NASA's X-38 spacecraft from a remote, ground-based cockpit using LandForm VisualFlight as part of his primary situation awareness display in a flight test at Edwards Air Force Base, California.

Source record↗

NASA Tech Briefs, March 2009

Topics covered include: Improved Instrument for Detecting Water and Ice in Soil; Real-Time Detection of Dust Devils from Pressure Readings; Determining Surface Roughness in Urban Areas Using Lidar Data; DSN Data Visualization Suite; Hamming and Accumulator Codes Concatenated with MPSK or QAM; Wide-Angle-Scanning Reflectarray Antennas Actuated by MEMS; Biasable Subharmonic Membrane Mixer for 520 to 600 GHz; Hardware Implementation of Serially Concatenated PPM Decoder; Symbolic Processing Combined with Model-Based Reasoning; Presentation Extensions of the SOAP; Spreadsheets for Analyzing and Optimizing Space Missions; Processing Ocean Images to Detect Large Drift Nets; Alternative Packaging for Back-Illuminated Imagers; Diamond Machining of an Off-Axis Biconic Aspherical Mirror; Laser Ablation Increases PEM/Catalyst Interfacial Area; Damage Detection and Self-Repair in Inflatable/Deployable Structures; Polyimide/Glass Composite High-Temperature Insulation; Nanocomposite Strain Gauges Having Small TCRs; Quick-Connect Windowed Non-Stick Penetrator Tips for Rapid Sampling; Modeling Unsteady Cavitation and Dynamic Loads in Turbopumps; Continuous-Flow System Produces Medical-Grade Water; Discrimination of Spore-Forming Bacilli Using spoIVA; nBn Infrared Detector Containing Graded Absorption Layer; Atomic References for Measuring Small Accelerations; Ultra-Broad-Band Optical Parametric Amplifier or Oscillator; Particle-Image Velocimeter Having Large Depth of Field; Enhancing SERS by Means of Supramolecular Charge Transfer; Improving 3D Wavelet-Based Compression of Hyperspectral Images; Improved Signal Chains for Readout of CMOS Imagers; SOI CMOS Imager with Suppression of Cross-Talk; Error-Rate Bounds for Coded PPM on a Poisson Channel; Biomorphic Multi-Agent Architecture for Persistent Computing; and Using Covariance Analysis to Assess Pointing Performance.

Source record↗

Thermal Performance of Spandrel Assemblies in Glazed Wall Systems: Laboratory Test Design – Challenges and Test Results

Accurate thermal performance calculation procedures for opaque spandrel areas in curtain wall and window wall systems are essential for rating systems when comparing spandrel systems. However, there is a lack of consensus in thermal modeling needed for accurately characterizing heat transfer through spandrel assemblies due to the complex arrangement of materials and structural components. Several studies indicate that conventional 2D thermal simulations may overestimate R-values by 30% compared to physical testing and 3D simulations. Detailed simulations and well-curated laboratory test data are necessary to build confidence in simulation models, which will later be used to develop correlations to improve widely used conventional 2D thermal simulations. This study aims to experimentally test heat transfer through various spandrel assemblies to validate 3D simulation models. Also, the challenges of conducting a thorough testing design along with the solutions would be documented. The team developed a design for testing spandrel assemblies, making appropriate modifications to the existing heat, air, and moisture (HAM) chamber to accommodate the testing needs. Two moveable baffles were designed and fabricated to guide airflow direction parallel to the test article surface. The data acquisition capabilities in the chamber were upgraded to add more than two hundred sensors to the climate and indoor side of the chamber. The goal is to provide a quality dataset for validating complex 3D modeling simulations, which will be used to develop improved thermal simulation techniques that more accurately represent the thermal behavior of spandrel assemblies and their integration within the building envelope. This paper will summarize the results for the boundary conditions of the testing and the temperature variation across different locations of the spandrel assemblies.

Kunwar, Niraj [ORNL] (ORCID:0000000263457652)↗

A Synopsis of AIRS Global-Mean Clear-Sky Radiance Trends From 2003 to 2020

Atmospheric Infrared Sounder (AIRS) aboard the National Aeronautics and Space Administration (NASA) Aqua satellite has been operating since September 2002. Its information content, superb instrument performance, and dense sampling pattern make the AIRS radiances an invaluable data set for climate studies. The trends of global-mean, nadir-view, clear-sky AIRS radiances from 2003 to 2020 are studied here, together with the counterparts of synthetic radiances based on two reanalyzes, European Centre for Medium-Range Weather Forecasts Reanalysis V5 (ECMWF ERA5) and NASA Goddard Earth Observing System V5.4.1 (GEOS-5.4.1; a reanalysis product without assimilation of hyperspectral radiances such as AIRS). The AIRS observation shows statistically significant negative trends in most of its CO2 channels, positive but non-significant trends in the channels over the window regions, and statistically significant positive trends in some of its H2O channels. The best agreements between observed and simulated radiance trends are seen over the CO2 tropospheric channels, while the observed and simulated trends over the CO2 stratospheric channels are opposite. ERA5 results largely agree with the AIRS observation over the H2O channels. The comparison in the H2O channels helps reveal a data continuity issue in the GEOS-5.4.1. Contributions from individual variables to the radiance trends are also assessed by performing separate simulations. This study provides the first synopsis of the global-mean trend of AIRS radiances over all its thermal-IR channels.

CO2↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗