Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HYDROGEN GUN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fusion energy

Larry Baylor explains how the US ITER team is working to prevent solar flare-like events at a fusion energy reactor that will be like a small sun on earth

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A high-resolution field-emission-gun, scanning electron microscope investigation of anisotropic hydrogen decrepitation in Nd-Fe-B-based sintered magnets

In this investigation commercial magnets based on (Nd,Dy){sub 14}(Fe,Co){sub 79}B{sub 7} were prepared by a conventional powder-metallurgy route with a degree of alignment equal to {approx}90% and then exposed to hydrogen at a pressure of 1 bar. The magnets, in the form of cylinders, were observed to decrepitate exclusively from the ends. High-resolution electron microscopy was able to identify the presence of crack formation within the Nd{sub 2}Fe{sub 14}B grains, with the cracks running parallel to the c axis of these grains. Based on the concentration profile for hydrogen in a rare-earth transition-metal material, it is clear that the presence of hydrogen-induced cracks running perpendicular to the ends of the magnet provides for a much more rapidly progressing hydrogen front in this direction than from the sides of the magnet. This results in the magnet exhibiting a macroscopic tendency to decrepitate from the poles of the magnet toward the center. This combination of microstructural modification via particle alignment as part of the sintering process and direct observation via high-resolution electron microscopy has led to a satisfying explanation for the anisotropic hydrogen-decrepitation effect.

36 MATERIALS SCIENCE↗

A Simple Design Erosional Plasma Gun Made of a Coaxial Cable with Polyethylene Insulation

Abstract—: A compact pulsed plasma generator of simple design made of a coaxial cable with polyethylene insulation has been described. A plasma gun generates a cloud of carbon-hydrogen plasma with an electron density of more than 10{sup 13} cm{sup –3}, including in a magnetic field produced of up to 500 G and also in the presence of the background plasma with a density of about 10{sup 12} cm{sup –3}, which is produced by an independent source. The high resource of the gun and stability of plasma parameters from one pulse to another allows using such a gun in laboratory experiments simulating dynamic processes in space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

JASPER Article

JASPER stands for Joint Actinide Shock Physics Experimental Research It is located in Area 27 at the NNSS. It houses a two-stage light-gas gun, using up to 3.5 kg gun powder in the first stage; the second stage uses hydrogen, helium, or nitrogen drive gasses to accelerate 28mm diameter, ≈ 25 g mass projectiles to reach launch velocities between 1.8-7.6 km/s. (7.6km/s ~ 17000 mph) The facility is operated by NSTec, and LLNS leads the scientific program, target design, fabrication, and engineering.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Energetic beams of negative and neutral hydrogen from intense laser plasma interaction

We present observations of intense beams of energetic negative hydrogen ions and fast neutral hydrogen atoms in intense (5 × 10{sup 19} W/cm{sup 2}) laser plasma interaction experiments, which were quantified in numerical calculations. Generation of negative ions and neutral atoms is ascribed to the processes of electron capture and loss by a laser accelerated positive ion in the collisions with a cloud of droplets. A comparison with a numerical model of charge exchange processes provides information on the cross section of the electron capture in the high energy domain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental characterization of a transition from collisionless to collisional interaction between head-on-merging supersonic plasma jets

We present results from experiments on the head-on merging of two supersonic plasma jets in an initially collisionless regime for the counter-streaming ions. The plasma jets are of either an argon/impurity or hydrogen/impurity mixture and are produced by pulsed-power-driven railguns. Based on time- and space-resolved fast-imaging, multi-chord interferometry, and survey-spectroscopy measurements of the overlapping region between the merging jets, we observe that the jets initially interpenetrate, consistent with calculated inter-jet ion collision lengths, which are long. As the jets interpenetrate, a rising mean-charge state causes a rapid decrease in the inter-jet ion collision length. Finally, the interaction becomes collisional and the jets stagnate, eventually producing structures consistent with collisional shocks. These experimental observations can aid in the validation of plasma collisionality and ionization models for plasmas with complex equations of state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Testing of a Prototype Eddy Current Actuated Valve for the ITER Shattered Pellet Injection System

Reliably mitigating disruptions is essential for ITER to meet its long-term operational research plan without damage to the in-vessel components. Currently, the shattered pellet injection (SPI) technique is the most effective radiator of thermal energy and has been chosen for the baseline disruption mitigation system (DMS) for ITER. The SPI process uses cryogenic temperatures to desublimate material into the barrel of a pipe gun forming a solid cylindrical pellet. Pellets for ITER will initially be hydrogen and hydrogen-neon mixtures. Once formed, pellets are dislodged and accelerated using high-pressure gas (40-60 bar) delivered by a fast-opening valve. The solenoid valves currently used for SPI experiments will not operate in an ITER environment due to the large background magnetic field. An ITER prototype fast-opening valve, called a flyer plate valve (FPV), has been designed and has undergone a wide range of testing. The FPV operates by pulsing current through a pancake coil that is closely coupled with a ``flyer plate.'' The flyer plate is an aluminum plate in which eddy currents are generated creating a repulsive force from the pancake coil. The force generated in the flyer plate rapidly lifts the valve tip off the seat and delivers a pulse of gas to the rear of the pellet, breaking it free from the barrel and accelerating the pellet downstream to its intended target. The design of the valve has been iterated on over the lifetime of this project, as the DMS for ITER shifted from massive gas injection (MGI) to SPI. The most recent design has been tested, and operational ranges have been mapped. The valve must survive 3000+ cycles in an ITER-like magnetic field. The principal functional requirement of this valve is to reliably dislodge and accelerate hydrogen (or H-Ne mixture) pellets into ITER. The valve was mated with an ITER SPI test stand and has been shown to be capable of launching pellets reliably. The valve and power supply design will be discussed in this article, along with the various testing setups used to determine the feasibility of this valve for use on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multiple gap plasma cathode electron gun and its electron beam analysis in self and trigger breakdown modes

In the present paper, a pseudospark discharge based multiple gap plasma cathode electron gun is reported which has been operated separately in self and trigger breakdown modes using two different gases, namely, argon and hydrogen. The beam current and beam energy have been analyzed using a concentric ring diagnostic arrangement. Two distinct electron beams are clearly seen with hollow cathode and conductive phases. The hollow cathode phase has been observed for ∼50 ns where the obtained electron beam is having low beam current density and high energy. While in conductive phase it is high current density and low energy electron beam. It is inferred that in the hollow cathode phase the beam energy is more for the self breakdown case whereas the current density is more for the trigger breakdown case. The tailor made operation of the hollow cathode phase electron beam can play an important role in microwave generation. Up to 30% variation in the electron beam energy has been achieved keeping the same gas and by varying the breakdown mode operations. Also, up to 32% variation in the beam current density has been achieved for the trigger breakdown mode at optimized trigger position by varying the gas type.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Capillary Guided Laser Plasma Accelerator Experiments at LBNL

Laser wakefield acceleration experiments were carried out by using a hydrogen-filled capillary discharge waveguide. For a 15 mm long, 200 {mu}m diameter capillary, quasi-monoenergetic e-beams up to 300 MeV were observed. By de-tuning discharge delay from optimum guiding performance, self-trapping was found to be stabilized. For a 33 mm long, 300 {mu}m capillary, a parameter regime with high energy electron beams, up to 1 GeV, was found. In this regime, the electron beam peak energy was correlated with the amount of trapped electrons.

43 PARTICLE ACCELERATORS↗

High-intensity laser-driven proton acceleration enhancement from hydrogen containing ultrathin targets

Laser driven proton acceleration experiments from micron and submicron thick targets using high intensity (2 × 10{sup 21} W/cm{sup 2}), high contrast (10{sup −15}) laser pulses show an enhancement of maximum energy when hydrogen containing targets were used instead of non-hydrogen containing. In our experiments, using thin (<1μm) plastic foil targets resulted in maximum proton energies that were consistently 20%–100% higher than when equivalent thickness inorganic targets, including Si{sub 3}N{sub 4} and Al, were used. Proton energies up to 20 MeV were measured with a flux of 10{sup 7} protons/MeV/sr.

36 MATERIALS SCIENCE↗

Ultrahigh-intensity optical slow-wave structure for direct laser electron acceleration

We report the development of corrugated slow-wave plasma guiding structures with application to quasi-phase-matched direct laser acceleration of charged particles. These structures support guided propagation at intensities up to 2x10{sup 17} W/cm{sup 2}, limited at present by our current laser energy and side leakage. Hydrogen, nitrogen, and argon plasma waveguides up to 1.5 cm in length with a corrugation period as short as 35 {mu}m are generated in extended cryogenic cluster jet flows, with corrugation depth approaching 100%. These structures remove the limitations of diffraction, phase matching, and material damage thresholds and promise to allow high-field acceleration of electrons over many centimeters using relatively small femtosecond lasers. We present simulations that show that a laser pulse power of 1.9 TW should allow an acceleration gradient larger than 80 MV/cm. A modest power of only 30 GW would still allow acceleration gradients in excess of 10 MV/cm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Secondary emission electron gun using external primaries

An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

47 OTHER INSTRUMENTATION↗

Comparison of cryogenic (hydrogen) and TESPEL (polystyrene) pellet particle deposition in a magnetically confined plasma

Here, a cryogenic pellet injector (PI) and tracer encapsulated solid pellet (TESPEL) injector system has been operated in combination on the stellarator TJ-II. This unique arrangement has been created by piggy-backing a TESPEL injector onto the backend of a pipe-gun–type PI. The combined injector provides a powerful new tool for comparing ablation and penetration of polystyrene TESPEL pellets and solid hydrogen pellets, as well as for contrasting subsequent pellet particle deposition and plasma perturbation under analogous plasma conditions. For instance, a significantly larger increase in plasma line-averaged electron density, and electron content, is observed after a TESPEL pellet injection compared with an equivalent cryogenic pellet injection. Moreover, for these injections from the low-magnetic-field side of the plasma cross-section, TESPEL pellets deposit electrons deeper into the plasma core than cryogenic pellets. Finally, the physics behind these observations and possible implications for pellet injection studies are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Twin-Screw Extruder Development for the ITER Pellet Injection System

The ITER pellet injection system is comprised of devices to form and accelerate pellets, and will be connected to inner wall guide tubes for fueling, and outer wall guide tubes for ELM pacing. An extruder will provide a stream of solid hydrogen isotopes to a secondary section, where pellets are cut and accelerated with a gas gun into the plasma. The ITER pellet injection system is required to provide a plasma fueling rate of 120 Pa-m3/s (900 mbar-L/s) and durations of up to 3000 s. The fueling pellets will be injected at a rate up to 10 Hz and pellets used to trigger ELMs will be injected at higher rates up to 20 Hz. A twin-screw extruder for the ITER pellet injection system is under development at the Oak Ridge National Laboratory. A one-fifth ITER scale prototype has been built and has demonstrated the production of a continuous solid deuterium extrusion. The 27 mm diameter, intermeshed, counter-rotating extruder screws are rotated at a rate up to ≈5 rpm. Deuterium gas is pre-cooled and liquefied and solidified in separate extruder barrels. The precooler consists of a deuterium gas filled copper coil suspended in a separate stainless steel vessel containing liquid nitrogen. The liquefier is comprised of a copper barrel connected to a Cryomech AL330 cryocooler, which has a machined helical groove surrounded by a copper jacket, through which the pre-cooled deuterium condenses. The lower extruder barrel is connected to a Cryomech GB-37 cryocooler to solidify the deuterium (at ≈15 K) before it is forced through the extruder die. The die forms the extrusion to a 3 mm x 4 mm rectangular cross section. Design improvements have been made to improve the pre-cooler and liquefier heat exchangers, to limit the loss of extrusion through gaps in the screws. This paper will describe the design improvements for the next iteration of the extruder prototype.

Meitner, Steven J↗

Wavefront Measurement for Laser-Guiding Diagnostic

The wavefront of a short laser pulse after interaction in a laser-plasma accelerator (LPA) was measured to diagnose laser-guiding quality. Experiments were performed on a 100 TW class laser at the LOASIS facility of LBNL using a hydrogen-filled capillary discharge waveguide. Laser-guiding with a pre-formed plasma channel allows the laser pulse to propagate over many Rayleigh lengths at high intensity and is crucial to accelerate electrons to the highest possible energy. Efficient coupling of laser energy into the plasma is realized when the laser and the channel satisfy a matched guiding condition, in which the wavefront remains flat within the channel. Using a wavefront sensor, the laser-guiding quality was diagnosed based on the wavefront of the laser pulse exiting the plasma channel. This wavefront diagnostic will contribute to achieving controlled, matched guiding in future experiments.

43 PARTICLE ACCELERATORS↗

Experimental characterization of a coaxial plasma accelerator for a colliding plasma experiment

We report experimental results of a single coaxial plasma accelerator in preparation for a colliding plasma experiment. The utilized device consisted of a coaxial pair of electrodes, accelerating the plasma due to J×B forces. A pulse forming network, composed of three capacitors connected in parallel, with a total capacitance of 27 μF was set up. A thyratron allowed to switch the maximum applied voltage of 9 kV. Under these conditions, the pulsed currents reached peak values of about 103 kA. The measurements were performed in a small vacuum chamber with a neutral-gas prefill at gas pressures between 10 Pa and 14 000 Pa. A gas mixture of ArH{sub 2} with 2.8% H{sub 2} served as the discharge medium. H{sub 2} was chosen in order to observe the broadening of the H{sub β} emission line and thus estimate the electron density. The electron density for a single plasma accelerator reached peak values on the order of 10{sup 16} cm{sup −3}. Electrical parameters, inter alia inductance and resistance, were determined for the LCR circuit during the plasma acceleration as well as in a short circuit case. Depending on the applied voltage, the inductance and resistance reached values ranging from 194 nH to 216 nH and 13 mΩ to 23 mΩ, respectively. Furthermore, the plasma velocity was measured using a fast CCD camera. Plasma velocities of 2 km/s up to 17 km/s were observed, the magnitude being highly correlated with gas pressure and applied voltage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Twin-Screw D-2 Extruder for the ITER Pellet Injection System

A twin-screw extruder for the ITER pellet injection system is under development at the Oak Ridge National Laboratory. The extruder will provide a stream of solid hydrogen isotopes to a secondary section, where pellets are cut and accelerated with single-stage gas gun into the plasma. A one-fifth ITER scale prototype extruder has been built to produce a continuous solid deuterium extrusion. Deuterium gas is precooled and liquefied before being introduced into the extruder. The precooler consists of a copper vessel containing liquid nitrogen surrounded by a deuterium gas filled copper coil. The liquefier is comprised of a copper cylinder connected to a Cryomech AL330 cryocooler, which is surrounded by a copper coil that the precooled deuterium flows through. The lower extruder barrel is connected to a Cryomech GB-37 cryocooler to solidify the deuterium (at approximate to 15 K) before it is forced through the extruder nozzle. A viewport located below the extruder nozzle provides a direct view of the extrusion. A camera is used to document the extrusion quality and duration. A data acquisition system records the extruder temperatures, torque, and speed, upstream, and downstream pressures. This paper will describe the prototype twin-screw extruder and initial extrusion results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗