Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HYBRID COMPUTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fault Diagnosis of Hybrid Computing Systems Using Chaotic-Map Method

Computing systems are becoming increasingly complex with nodes consisting of a combination of multi-core central processing units (CPUs), many integrated core (MIC) and graphics processing unit (GPU) accelerators. These computing units and their interconnections are subject to different classes of hardware and software faults, which should be detected to support mitigation measures. We present the chaotic-map method that uses the exponential divergence and wide Fourier properties of the trajectories, combined with memory allocations and assignments to diagnose component-level faults in these hybrid computing systems. We propose lightweight codes that utilize highly parallel chaotic-map computations tailored to isolate faults in arithmetic units, memory elements and interconnects. The diagnosis module on a node utilizes pthreads to place chaotic-map threads on CPU and MIC cores, and CUDA C and OpenCL kernels on GPU blocks. We present experimental diagnosis results on five multi-core CPUs; one MIC; and, seven GPUs with typical diagnosis run-times under a minute.

Rao, Nageswara↗

Hybrid computational phantoms of the 15-year male and female adolescent: Applications to CT organ dosimetry for patients of variable morphometry

Currently, two classes of the computational phantoms have been developed for dosimetry calculation: (1) stylized (or mathematical) and (2) voxel (or tomographic) phantoms describing human anatomy through mathematical surface equations and three-dimensional labeled voxel matrices, respectively. Mathematical surface equations in stylized phantoms provide flexibility in phantom design and alteration, but the resulting anatomical description is, in many cases, not very realistic. Voxel phantoms display far better anatomical realism, but they are limited in terms of their ability to alter organ shape, position, and depth, as well as body posture. A new class of computational phantoms - called hybrid phantoms - takes advantage of the best features of stylized and voxel phantoms - flexibility and anatomical realism, respectively. In the current study, hybrid computational phantoms representing reference 15-year male and female body anatomy and anthropometry are presented. For the male phantom, organ contours were extracted from the University of Florida (UF) 14-year series B male voxel phantom, while for the female phantom, original computed tomography (CT) data from two 14-year female patients were used. Polygon mesh models for the major organs and tissues were reconstructed for nonuniform rational B-spline (NURBS) surface modeling. The resulting NURBS/polygon mesh models representing body contour and internal anatomy were matched to anthropometric data and reference organ mass data provided by the Centers for Disease Control and Prevention (CDC) and the International Commission on Radiation Protection (ICRP), respectively. Finally, two hybrid 15-year male and female phantoms were completed where a total of eight anthropometric data categories were matched to standard values within 4% and organ masses matched to ICRP data within 1% with the exception of total skin. To highlight the flexibility of the hybrid phantoms, 10th and 90th weight percentile 15-year male and female phantoms were further developed from the 50th percentile phantoms through adjustments in the body contour to match the total body masses given in CDC pediatric growth curves. The resulting six NURBS phantoms, male and female phantoms representing their 10th, 50th, and 90th weight percentiles, were used to investigate the influence of body fat distributions on internal organ doses following CT imaging. The phantoms were exposed to multislice chest and abdomen helical CT scans, and in-field organ absorbed doses were calculated. The results demonstrated that the use of traditional stylized phantoms yielded organ dose estimates that deviate from those given by the UF reference hybrid phantoms by up to a factor of 2. The study also showed that use of reference, or 50th percentile, phantoms to assess organ doses in underweight 15-year-old children would not lead to significant organ dose errors (typically less than 10%). However, more significant errors were noted (up to {approx}30%) when reference phantoms are used to represent overweight children in CT imaging dosimetry. These errors are expected to only further increase as one considers CT organ doses in overweight and obese individuals of the adult patient population, thus emphasizing the advantages of patient-sculptable phantom technology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Checkpointing for a hybrid computing node

According to an aspect, a method for checkpointing in a hybrid computing node includes executing a task in a processing accelerator of the hybrid computing node. A checkpoint is created in a local memory of the processing accelerator. The checkpoint includes state data to restart execution of the task in the processing accelerator upon a restart operation. Execution of the task is resumed in the processing accelerator after creating the checkpoint. The state data of the checkpoint are transferred from the processing accelerator to a main processor of the hybrid computing node while the processing accelerator is executing the task.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-13: A Feasibility Study of the Use of Hybrid Computational Phantoms for Improved Historical Dose Reconstruction in the Study of Late Radiation Effects for Hodgkin's Lymphoma

Purpose: Radiation-induced cancer effects are well-documented following radiotherapy. Further investigation is needed to more accurately determine a dose-response relationship for late radiation effects. Recent dosimetry studies tend to use representative patients (Taylor 2009) or anthropomorphic phantoms (Wirth 2008) for estimating organ mean doses. In this study, we compare hybrid computational phantoms to patient-specific voxel phantoms to test the accuracy of University of Florida Hybrid Phantom Library (UFHP Library) for historical dose reconstructions. Methods: A cohort of 10 patients with CT images was used to reproduce the data that was collected historically for Hodgkin's lymphoma patients (i.e. caliper measurements and photographs). Four types of phantoms were generated to show a range of refinement from reference hybrid-computational phantom to patient-specific phantoms. Each patient is matched to a reference phantom from the UFHP Library based on height and weight. The reference phantom is refined in the anterior/posterior direction to create a ‘caliper-scaled phantom’. A photograph is simulated using a surface rendering from segmented CT images. Further refinement in the lateral direction is performed using ratios from a simulated-photograph to create a ‘photograph and caliper-scaled phantom’; breast size and position is visually adjusted. Patient-specific hybrid phantoms, with matched organ volumes, are generated and show the capabilities of the UF Hybrid Phantom Library. Reference, caliper-scaled, photograph and caliper-scaled, and patient-specific hybrid phantoms are compared with patient-specific voxel phantoms to determine the accuracy of the study. Results: Progression from reference phantom to patient specific hybrid shows good agreement with the patient specific voxel phantoms. Each stage of refinement shows an overall trend of improvement in dose accuracy within the study, which suggests that computational phantoms can show improved accuracy in historical dose estimates. Conclusion: Computational hybrid phantoms show promise for improved accuracy within retrospective studies when CTs and other x-ray images are not available.

60 APPLIED LIFE SCIENCES↗

Spatially hybrid computations for streamer discharges with generic features of pulled fronts: I. Planar fronts

Streamers are the first stage of sparks and lightning; they grow due to a strongly enhanced electric field at their tips; this field is created by a thin curved space charge layer. These multiple scales are already challenging when the electrons are approximated by densities. However, electron density fluctuations in the leading edge of the front and non-thermal stretched tails of the electron energy distribution (as a cause of X-ray emissions) require a particle model to follow the electron motion. But present computers cannot deal with all electrons in a fully developed streamer. Therefore, super-particle have to be introduced, which leads to wrong statistics and numerical artifacts. The method of choice is a hybrid computation in space where individual electrons are followed in the region of high electric field and low density while the bulk of the electrons is approximated by densities (or fluids). We here develop the hybrid coupling for planar fronts. First, to obtain a consistent flux at the interface between particle and fluid model in the hybrid computation, the widely used classical fluid model is replaced by an extended fluid model. Then the coupling algorithm and the numerical implementation of the spatially hybrid model are presented in detail, in particular, the position of the model interface and the construction of the buffer region. The method carries generic features of pulled fronts that can be applied to similar problems like large deviations in the leading edge of population fronts, etc.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A High-Performance Hybrid Computing Approach to Massive Contingency Analysis in the Power Grid

Operating the electrical power grid to prevent power black-outs is a complex task. An important aspect of this is contingency analysis, which involves understanding and mitigating potential failures in power grid elements such as transmission lines. When taking into account the potential for multiple simultaneous failures (known as the N-x contingency problem), contingency analysis becomes a massively computational task. In this paper we describe a novel hybrid computational approach to contingency analysis. This approach exploits the unique graph processing performance of the Cray XMT in conjunction with a conventional massively parallel compute cluster to identify likely simultaneous failures that could cause widespread cascading power failures that have massive economic and social impact on society. The approach has the potential to provide the first practical and scalable solution to the N-x contingency problem. When deployed in power grid operations, it will increase the grid operator’s ability to deal effectively with outages and failures with power grid components while preserving stable and safe operation of the grid. The paper describes the architecture of our solution and presents preliminary performance results that validate the efficacy of our approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mechanisms in the Synthesis of S -Alcohols with 1,4-NADH Biomimetic Co-factor N-Benzyl-1,4-dihydronicotinamide using Horse Liver Alcohol Dehydrogenase: A Hybrid Computational Study

The enantioselective reduction of prochiral ketones catalyzed by horse liver alcohol dehydrogenase (HLADH), was investigated via a hybrid computational approach, for molecular reactions involved in chiral synthesis of S-alcohols, when the natural co-factor, 1,4-dihyronicotinamide adenine dinucleotide, 1,4-NADH, was replaced with biomimetic co-factor, N-benzyl-1,4-dihydronicotinamide, 1. We surmised that different hydride and proton transfer mechanisms were involved using co-factor, 1. An alternative mechanism, where the hydride transfer step occurred, via an η 1 -keto-S-η 2 -5,6-1,4-dihydronicotinamide-Zn(II) complex, was previously investigated with a model of the HLADH-Zn(II) catalytic site (J. Organometal. Chem. 2021, 943, 121810). Presently, we studied canonical and alternative mechanisms compared to models of the entire enzyme structure. We disproved the η 2 -Zn(II) complex, and discovered a canonical hydride transfer from biomimetic 1,4-NADH, 1, to the Zn(II) bound prochiral ketone substrate, followed by a new proton relay, consisting of a water chain connecting His51 to Ser48 that accomplished the S-alkoxy anion's protonation to yield the final S-alcohol product. The HLADH catalysis, with biomimetic co-factor, 1, that replaced the ribose group, the 5'-diphosphate groups, and the adenine nucleotide with a N-benzyl group, has provided a new paradigm for the design of other structures of 1,4-NADH biomimetic co-factors, including their economic value in biocatalysis reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Autonomic Management of Application Workflows on Hybrid Computing Infrastructure

In this paper, we present a programming and runtime framework that enables the autonomic management of complex application workflows on hybrid computing infrastructures. The framework is designed to address system and application heterogeneity and dynamics to ensure that application objectives and constraints are satisfied. The need for such autonomic system and application management is becoming critical as computing infrastructures become increasingly heterogeneous, integrating different classes of resources from high-end HPC systems to commodity clusters and clouds. For example, the framework presented in this paper can be used to provision the appropriate mix of resources based on application requirements and constraints. The framework also monitors the system/application state and adapts the application and/or resources to respond to changing requirements or environment. To demonstrate the operation of the framework and to evaluate its ability, we employ a workflow used to characterize an oil reservoir executing on a hybrid infrastructure composed of TeraGrid nodes and Amazon EC2 instances of various types. Specifically, we show how different applications objectives such as acceleration, conservation and resilience can be effectively achieved while satisfying deadline and budget constraints, using an appropriate mix of dynamically provisioned resources. Our evaluations also demonstrate that public clouds can be used to complement and reinforce the scheduling and usage of traditional high performance computing infrastructure.

Kim, Hyunjoo↗

SU-E-CAMPUS-I-02: Estimation of the Dosimetric Error Caused by the Voxelization of Hybrid Computational Phantoms Using Triangle Mesh-Based Monte Carlo Transport

Purpose: Computational voxel phantom provides realistic anatomy but the voxel structure may result in dosimetric error compared to real anatomy composed of perfect surface. We analyzed the dosimetric error caused from the voxel structure in hybrid computational phantoms by comparing the voxel-based doses at different resolutions with triangle mesh-based doses. Methods: We incorporated the existing adult male UF/NCI hybrid phantom in mesh format into a Monte Carlo transport code, penMesh that supports triangle meshes. We calculated energy deposition to selected organs of interest for parallel photon beams with three mono energies (0.1, 1, and 10 MeV) in antero-posterior geometry. We also calculated organ energy deposition using three voxel phantoms with different voxel resolutions (1, 5, and 10 mm) using MCNPX2.7. Results: Comparison of organ energy deposition between the two methods showed that agreement overall improved for higher voxel resolution, but for many organs the differences were small. Difference in the energy deposition for 1 MeV, for example, decreased from 11.5% to 1.7% in muscle but only from 0.6% to 0.3% in liver as voxel resolution increased from 10 mm to 1 mm. The differences were smaller at higher energies. The number of photon histories processed per second in voxels were 6.4×10{sup 4}, 3.3×10{sup 4}, and 1.3×10{sup 4}, for 10, 5, and 1 mm resolutions at 10 MeV, respectively, while meshes ran at 4.0×10{sup 4} histories/sec. Conclusion: The combination of hybrid mesh phantom and penMesh was proved to be accurate and of similar speed compared to the voxel phantom and MCNPX. The lowest voxel resolution caused a maximum dosimetric error of 12.6% at 0.1 MeV and 6.8% at 10 MeV but the error was insignificant in some organs. We will apply the tool to calculate dose to very thin layer tissues (e.g., radiosensitive layer in gastro intestines) which cannot be modeled by voxel phantoms.

60 APPLIED LIFE SCIENCES↗

Hybrid Computing Technique for Nuclear Facility Design with Best Estimate Source Terms - 12313

When overall source term representing a variety of spent fuels or rad-wastes with different irradiation and decay profile is estimated, there are some restrictions in conventional analysis tools. A hybrid computing program that employs several functional modules was developed to support R and D action plan on an advanced fuel cycle adopting a pyro-process in connection with a sodium-cooled fast reactor in South Korea. Requirements for the advanced program were first defined, followed by development of several functional modules. With the developed modules, it was possible to carry out a source term assessment taking into account respective physical, irradiation, and aging characteristics of each spent fuel. And it was found that typical conservativeness in the design of nuclear facilities can be minimized through the hybrid technique and program proposed in this study. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential of Hybrid Computational Phantoms for Retrospective Heart Dosimetry After Breast Radiation Therapy: A Feasibility Study

Purpose: Current retrospective cardiovascular dosimetry studies are based on a representative patient or simple mathematic phantoms. Here, a process of patient modeling was developed to personalize the anatomy of the thorax and to include a heart model with coronary arteries. Methods and Materials: The patient models were hybrid computational phantoms (HCPs) with an inserted detailed heart model. A computed tomography (CT) acquisition (pseudo-CT) was derived from HCP and imported into a treatment planning system where treatment conditions were reproduced. Six current patients were selected: 3 were modeled from their CT images (A patients) and the others were modelled from 2 orthogonal radiographs (B patients). The method performance and limitation were investigated by quantitative comparison between the initial CT and the pseudo-CT, namely, the morphology and the dose calculation were compared. For the B patients, a comparison with 2 kinds of representative patients was also conducted. Finally, dose assessment was focused on the whole coronary artery tree and the left anterior descending coronary. Results: When 3-dimensional anatomic information was available, the dose calculations performed on the initial CT and the pseudo-CT were in good agreement. For the B patients, comparison of doses derived from HCP and representative patients showed that the HCP doses were either better or equivalent. In the left breast radiation therapy context and for the studied cases, coronary mean doses were at least 5-fold higher than heart mean doses. Conclusions: For retrospective dose studies, it is suggested that HCP offers a better surrogate, in terms of dose accuracy, than representative patients. The use of a detailed heart model eliminates the problem of identifying the coronaries on the patient's CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A hybrid computational strategy to address WGS variant analysis in >5000 samples

Abstract Background The decreasing costs of sequencing are driving the need for cost effective and real time variant calling of whole genome sequencing data. The scale of these projects are far beyond the capacity of typical computing resources available with most research labs. Other infrastructures like the cloud AWS environment and supercomputers also have limitations due to which large scale joint variant calling becomes infeasible, and infrastructure specific variant calling strategies either fail to scale up to large datasets or abandon joint calling strategies. Results We present a high throughput framework including multiple variant callers for single nucleotide variant (SNV) calling, which leverages hybrid computing infrastructure consisting of cloud AWS, supercomputers and local high performance computing infrastructures. We present a novel binning approach for large scale joint variant calling and imputation which can scale up to over 10,000 samples while producing SNV callsets with high sensitivity and specificity. As a proof of principle, we present results of analysis on Cohorts for Heart And Aging Research in Genomic Epidemiology (CHARGE) WGS freeze 3 dataset in which joint calling, imputation and phasing of over 5300 whole genome samples was produced in under 6 weeks using four state-of-the-art callers. The callers used were SNPTools, GATK-HaplotypeCaller, GATK-UnifiedGenotyper and GotCloud. We used Amazon AWS, a 4000-core in-house cluster at Baylor College of Medicine, IBM power PC Blue BioU at Rice and Rhea at Oak Ridge National Laboratory (ORNL) for the computation. AWS was used for joint calling of 180 TB of BAM files, and ORNL and Rice supercomputers were used for the imputation and phasing step. All other steps were carried out on the local compute cluster. The entire operation used 5.2 million core hours and only transferred a total of 6 TB of data across the platforms. Conclusions Even with increasing sizes of whole genome datasets, ensemble joint calling of SNVs for low coverage data can be accomplished in a scalable, cost effective and fast manner by using heterogeneous computing platforms without compromising on the quality of variants.

59 BASIC BIOLOGICAL SCIENCES↗

Ensuring statistical reproducibility of ocean model simulations in the age of hybrid computing

Novel high performance computing systems that feature hybrid architectures require large scale code refactoring to unravel underlying exploitable parallelism. Such redesign can often be accompanied with machine-precision changes as the order of computation cannot always be maintained. For chaotic systems like climate models, these round-off level differences can grow rapidly. Systematic errors may also manifest initially as machine-precision differences. Isolating genuine round off level differences from such errors remains a challenge. Here, we apply two-sample equality of distribution tests to evaluate statistical reproducibility of the ocean model component of US Department of Energy's Energy Exascale Earth System Model (E3SM). A 2-year control simulation ensemble is compared to a modified ensemble as a test case - after a known non-bit-for-bit change in a model component is introduced - to evaluate the null hypothesis that the two ensembles are statistically indistinguishable. To quantify the false negative rates of these tests, we conduct a formal power analysis using a targeted suite of short simulation ensembles. The ensemble suite contains several perturbed ensembles, each with a progressively different climate than the baseline ensemble - obtained by perturbing the magnitude of a single model tuning parameter, the Gent and McWilliams κ, in a controlled manner. The null hypothesis is evaluated for each of perturbed ensembles using these tests. The power analysis informs on the detection limits of the tests for given ensemble size allowing model developers to evaluate the impact of an introduced non-bit-for-bit change to the model.

Mahajan, Salil↗

Hardware-accelerated Components for Hybrid Computing Systems

We present a study on the use of component technology for encapsulating platform-specific hardwareaccelerated algorithms on hybrid HPC systems. Our research shows that component technology can have significant benefits from a software engineering pointof- view to increase encapsulation, portability and reduce or eliminate platform dependence for hardwareaccelerated algorithms. As a demonstration of this concept, we discuss our experience in designing, implementing and integrating an FPGA-accelerated kernel for Polygraph, an application in computational proteomics.

97 MATHEMATICS AND COMPUTING↗

Performance Optimization of a Beam Dynamics PIC Code On Hybrid Computer Architectures

The self-consistent multi-particle tracking based on particle-in-cell method (PIC) has been widely used in particle accelerator beam dynamics study. However, the PIC simulation is time-consuming and needs to use modern parallel computers for high resolution applications. In this paper, we implemented and optimized a parallel beam dynamics PIC code on two types of hybrid parallel computer architectures: one is the GPU and GPU cluster, while the other is the "Knight Landing" CPU cluster.

Liu, Zhicong↗

NREL's Journey with HPC in the Cloud and Hybrid Computing

This is a planned lightning talk at the NLIT Summit 2025 conference. This would serve as somewhat of a progress update to the presentation I gave at re:Invent 2024 back in November which can be seen here: https://www.youtube.com/watch?t=2133&v=NMq3kL9qObU&feature=youtu.be (my section begins at the included timestamp value). This presentation discusses our usage of Cloud-hosted HPC systems, and in what circumstances they benefit our researchers strategically. We have been making incremental progress in this area since that recording, so for this presentation I would include our latest experiences and observations as we are beginning to implement a hybrid HPC solution. We're in the midst of a cross-team effort of implementing a prototype hybridization solution which would allow users to strategically burst jobs to the cloud. In this talk for NLIT, I would detail lessons-learned, non-starters, architecture diagrams, and other implementation details that may benefit those interested as we continue our experimentation. Our prototype may not be complete by the time of this presentation, but even in the discovery phase of our anticipated design we've discovered a lot of information from others who have worked on hybrid solutions that are worth sharing.

97 MATHEMATICS AND COMPUTING↗

Dual-solver hybrid computational approaches for design and analysis of vertical lift vehicles

Abstract The cost of Reynolds-Averaged Navier-Stokes simulations can be restrictive to implement in aeromechanics design and analysis of vertical lift configurations given the cost to resolve the flow on a mesh sufficient to provide accurate aerodynamic and structural loads. Dual-solver hybrid methods have been developed that resolve the configuration and the near field with the Reynolds-Averaged Navier-Stokes solvers, while the wake is resolved with vorticity-preserving methods that are more cost-effective. These dual-solver approaches can be integrated into an organisation’s workflow to bridge the gap between lower-fidelity methods and the expensive Reynolds-Averaged Navier-Stokes when there are complex physics present. This paper provides an overview of different dual-solver hybrid methods, coupling approaches, and future efforts to expand their capabilities in the areas of novel configurations and operations in constrained and turbulent environments.

Engineering↗

A Multi-Compartment Hybrid Computational Model Predicts Key Roles for Dendritic Cells in Tuberculosis Infection

Tuberculosis (TB) is a world-wide health problem with approximately 2 billion people infected with Mycobacterium tuberculosis (Mtb, the causative bacterium of TB). The pathologic hallmark of Mtb infection in humans and Non-Human Primates (NHPs) is the formation of spherical structures, primarily in lungs, called granulomas. Infection occurs after inhalation of bacteria into lungs, where resident antigen-presenting cells (APCs), take up bacteria and initiate the immune response to Mtb infection. APCs traffic from the site of infection (lung) to lung-draining lymph nodes (LNs) where they prime T cells to recognize Mtb. These T cells, circulating back through blood, migrate back to lungs to perform their immune effector functions. We have previously developed a hybrid agent-based model (ABM, labeled GranSim) describing in silico immune cell, bacterial (Mtb) and molecular behaviors during tuberculosis infection and recently linked that model to operate across three physiological compartments: lung (infection site where granulomas form), lung draining lymph node (LN, site of generation of adaptive immunity) and blood (a measurable compartment). Granuloma formation and function is captured by a spatio-temporal model (i.e., ABM), while LN and blood compartments represent temporal dynamics of the whole body in response to infection and are captured with ordinary differential equations (ODEs). In order to have a more mechanistic representation of APC trafficking from the lung to the lymph node, and to better capture antigen presentation in a draining LN, this current study incorporates the role of dendritic cells (DCs) in a computational fashion into GranSim.

59 BASIC BIOLOGICAL SCIENCES↗