HVAC System Performance for Energy Codes (Technical Brief)

The prescriptive path is likely the most widely used approach for commercial code compliance in the United States. Though easy to implement, the prescriptive approach does not discriminate between high-performing and poorly performing heating, ventilation, air conditioning (HVAC) system configurations that are both minimally compliant. To meet aggressive energy and carbon reduction goals, energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. HVAC System Performance is a discipline performance path and provides a simpler solution to HVAC system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution that could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A web-based calculation tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach has also been evaluated by the ASHRAE Standard 90.1 Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Residential HVAC Systems: Evaluating How the Usage of Smart Diagnostic Tools for Quality Installation and Commissioning Impacts System Performance and HVAC Contractor Businesses

The adoption of digital quality installation and fault detection tools has the potential to transform the $14 billon residential heating, ventilating, and air conditioning (HVAC) service and installation industry. Increased market penetration can be accelerated by providing an increased understanding of the energy and economic value proposition of the usage of these tools. In tandem with energy and HVAC system performance impact research and analysis, the Southface Team investigated the economic business implications for HVAC service and installation contractors adopting the use of measureQuick (mQ), a smart diagnostic app that aids in quality installation and fault detection and works agnostically with Bluetooth-enabled HVAC technician tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lessons learned from the development and implementation of a workforce training curriculum for advanced controls for high performance HVAC systems

Over the past decade, academic research on advanced controls has slowly transitioned into new software platforms, giving rise to various companies developing and deploying these innovative products, including solutions for light commercial HVAC systems. However, the current workforce remains widely unprepared to install, maintain and operate these systems, particularly complex software-based control platforms, as most workforce training programs still focus on traditional building automation for large commercial buildings. This paper presents the development and piloting of curriculum for three key types of professionals: ● Technicians (trade-level): installing and maintaining modern high-performance HVAC systems and controls ● Programmers (undergrad-level): developing and implementing advanced controls ● Engineers and energy professionals (undergrad/grad-level): managing and evaluating system performance We share details of the material developed including training videos, open-source software, instruction manuals. We also present the results of a pilot implementation of the training materials with real students.

Casillas, Armando↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Are Deep Energy Retrofits in Commercial Buildings Including Window Upgrades?

U.S. Commercial buildings account for about 20% of total U.S. energy consumption. Because the thermal performance of windows significantly affects building energy efficiency and HVAC system performance, best practice guidance often includes window and envelope improvements in conjunction with HVAC upgrades to optimize energy use and improve occupant comfort. It is an open question, however, regarding how often these best practices are implemented in the field. This paper aims to address that gap by conducting a literature review and a series of interviews with commercial building auditing and management professionals to explore the factors that drive window retrofits in commercial buildings. The paper explores a range of case studies from deep energy retrofits across the globe, comparing projects with and without window retrofits. The primary goals of this review are to: (1) provide data from real-world case studies illustrating the role of windows in deep energy renovations and HVAC upgrades, (2) conduct retrofit cost analyses for windows and high-performance HVAC systems and (3) offer insights into how window upgrade decisions are made and when they are implemented as part of deep energy retrofits. Most of the retrofit studies focused exclusively on high performance HVAC upgrades without considering how window upgrades might further enhance the overall energy efficiency of commercial buildings. Interviews with building industry experts shed light on the key factors influencing deep energy retrofit decisions and what factors tip the scales in favor of including window measures with more comprehensive retrofit projects.

Cort, Katherine↗

Thermal Components Boost Performance of HVAC Systems

As the International Space Station (ISS) travels 17,500 miles per hour, normal is having a constant sensation of free-falling. Normal is no rain, but an extreme amount of shine.with temperatures reaching 250 F when facing the Sun. Thanks to a number of advanced control systems onboard the ISS, however, the interior of the station remains a cool, comfortable, normal environment where astronauts can live and work for extended periods of time. There are two main control systems on the ISS that make it possible for humans to survive in space: the Thermal Control System (TCS) and the Environmental Control and Life Support system. These intricate assemblies work together to supply water and oxygen, regulate temperature and pressure, maintain air quality, and manage waste. Through artificial means, these systems create a habitable environment for the space station s crew. The TCS constantly works to regulate the temperature not only for astronauts, but for the critical instruments and machines inside the spacecraft as well. To do its job, the TCS encompasses several components and systems both inside and outside of the ISS. Inside the spacecraft, a liquid heat-exchange process mechanically pumps fluids in closed-loop circuits to collect, transport, and reject heat. Outside the ISS, an external system circulates anhydrous ammonia to transport heat and cool equipment, and radiators release the heat into space. Over the years, NASA has worked with a variety of partners.public and private, national and international. to develop and refine the most complex thermal control systems ever built for spacecraft, including the one on the ISS.

Source record↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Achieving Ducts in Conditioned Space

As codes push for greater energy savings, production homebuilders must consider ways to reduce the energy use associated with HVAC system performance. One prominent and effective approach to reduce energy use is the transition of ductwork from unconditioned space (attics, crawlspaces, basements) into conditioned space.

Building America↗

Impact of refrigerant undercharge faults on building indoor conditions and HVAC system operation in residential Buildings: A simulation study

This study investigates the impact of refrigerant undercharge on indoor temperature and HVAC system performance in residential buildings. Simulation models for typical residential buildings in Orlando, FL and Indianapolis, IN were developed using the ResStock database. A refrigerant undercharge fault model was then applied to the simulations with varying levels of fault intensity. The paper offers an extensive analysis, revealing that variations in supply air temperature, equipment runtime, and cooling energy consumption due to the level of refrigerant undercharge faults are notably significant on a summer representative day. Similarly, on a winter representative day, changes in supply air temperature and runtime are significant as well as changes in supplemental heat energy consumption. We find that occupants may remain oblivious to these faults during the cooling season, particularly when the HVAC system is oversized; in that case, supply air temperature data could help detect a fault. Another challenge is that during the heating season, when the supplemental heater operates, it is difficult to identify a refrigerant undercharge fault using only indoor and supply air temperature data. Finally, this study finds that supply air temperature, equipment runtime, and supplemental heater energy consumption data can help in detecting refrigerant undercharge faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical validation of building energy simulation model input parameter for multizone commercial building during the cooling season

This paper presents a critical advancement in Building Energy Modeling (BEM) through an empirical validation approach using a high-quality dataset from a multizone commercial office building in Oak Ridge, TN, USA. BEM is widely utilized in diverse construction applications, but its effectiveness relies on the accuracy of its predictions. The study focuses on empirical validation of input parameters in BEM, including building envelope data, infiltration modeling, and rooftop unit system performance curves. The validation of simulation input parameters leads to substantial improvements in the accuracy of simulation results. Notable both NMBE and cv (RMSE) values are reduced by 0.5 % for indoor air temperature and 17 % for indoor air relative humidity compared to the previous model. At the system level, both NMBE and cv (RMSE) values are reduced by 2 % for fan energy consumption and 4 % for cooling energy consumption, compared to the previous model. A literature review highlights a significant gap in empirical validation studies, which predominantly concentrate on either component-level or whole building validation. Furthermore, many studies employ simplified setups that may not faithfully represent the complexities of multizone commercial buildings. This paper distinguishes itself by emphasizing the critical importance of component-level input parameter validation. It underlines the need to validate data related to building envelope components and HVAC system performance curves, resulting in more accurate simulation outcomes. In conclusion, the utilization of actual multizone commercial building data enhances the study's practical relevance. In summary, this research underscores the pivotal role of input parameter validation in enhancing the accuracy and reliability of BEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fault Dataset Development for VAV Terminal Units: Damper and Airflow Sensor Faults

This report analyzes field data to understand the impact of faults in variable air volume (VAV) terminal units on building indoor conditions and heating, ventilation, and air-conditioning (HVAC) system operations. The Oak Ridge National Laboratory (ORNL) team conducted field tests at the commercial building test facility known as ORNL’s Flexible Research Platform (FRP) building. Two specific faults-damper malfunctions and airflow sensor inaccuracies- were implemented, as these are common faults in VAV terminal units and can significantly impact HVAC system performance by increasing energy consumption, causing occupant discomfort, and raising operational costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY↗

Datasets of a Multizone Office Building under Different HVAC System Operation Scenarios

Abstract This study provides an open-source dataset of the measured weather data, building indoor data, and system data under the different test settings. The test building is the two-story Flexible Research Platform building at the US Department of Energy’s Oak Ridge National Laboratory, in Oak Ridge, Tennessee. Four heating tests and three cooling tests were conducted. The 1-min interval of weather, building indoor data, and system data from each test setting are provided. Actual weather data were collected from a weather station installed on the roof. This paper describes information on the test building and installed sensors, data collection method, and data validation. The provided dataset can be employed to understand HVAC system conditions and building indoor conditions under different HVAC system operations and the performance of building envelope without HVAC system operation using free-floating test data. Additionally, it can be used for empirical validation of the building energy modelling engine.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spinoff 2011

Topics include: Bioreactors Drive Advances in Tissue Engineering; Tooling Techniques Enhance Medical Imaging; Ventilator Technologies Sustain Critically Injured Patients; Protein Innovations Advance Drug Treatments, Skin Care; Mass Analyzers Facilitate Research on Addiction; Frameworks Coordinate Scientific Data Management; Cameras Improve Navigation for Pilots, Drivers; Integrated Design Tools Reduce Risk, Cost; Advisory Systems Save Time, Fuel for Airlines; Modeling Programs Increase Aircraft Design Safety; Fly-by-Wire Systems Enable Safer, More Efficient Flight; Modified Fittings Enhance Industrial Safety; Simulation Tools Model Icing for Aircraft Design; Information Systems Coordinate Emergency Management; Imaging Systems Provide Maps for U.S. Soldiers; High-Pressure Systems Suppress Fires in Seconds; Alloy-Enhanced Fans Maintain Fresh Air in Tunnels; Control Algorithms Charge Batteries Faster; Software Programs Derive Measurements from Photographs; Retrofits Convert Gas Vehicles into Hybrids; NASA Missions Inspire Online Video Games; Monitors Track Vital Signs for Fitness and Safety; Thermal Components Boost Performance of HVAC Systems; World Wind Tools Reveal Environmental Change; Analyzers Measure Greenhouse Gasses, Airborne Pollutants; Remediation Technologies Eliminate Contaminants; Receivers Gather Data for Climate, Weather Prediction; Coating Processes Boost Performance of Solar Cells; Analyzers Provide Water Security in Space and on Earth; Catalyst Substrates Remove Contaminants, Produce Fuel; Rocket Engine Innovations Advance Clean Energy; Technologies Render Views of Earth for Virtual Navigation; Content Platforms Meet Data Storage, Retrieval Needs; Tools Ensure Reliability of Critical Software; Electronic Handbooks Simplify Process Management; Software Innovations Speed Scientific Computing; Controller Chips Preserve Microprocessor Function; Nanotube Production Devices Expand Research Capabilities; Custom Machines Advance Composite Manufacturing; Polyimide Foams Offer Superior Insulation; Beam Steering Devices Reduce Payload Weight; Models Support Energy-Saving Microwave Technologies; Materials Advance Chemical Propulsion Technology; and High-Temperature Coatings Offer Energy Savings.

Source record↗

Infrared-Fused Vision-Based Thermoregulation Performance Estimation for Personal Thermal Comfort-Driven HVAC System Controls

Thermal comfort is one of the primary factors influencing occupant health, well-being, and productivity in buildings. Existing thermal comfort systems require occupants to frequently communicate their comfort vote via a survey which is impractical as a long-term solution. Here, we present a novel thermal infrared-fused computer vision sensing method to capture thermoregulation performance in a non-intrusive and non-invasive manner. In this method, we align thermal and visible images, detect facial segments (i.e., nose, eyes, face boundary), and accordingly read the temperatures from the appropriate coordinates in the thermal image. We focus on the human face since it is often clearly visible to cameras and is not merged into a hot background (unlike hands). We use a regularized Gaussian Mixture model to track the thermoregulation changes over time and apply a heuristic algorithm to extract hot and cold indices. We present a personalized and a generalized comfort modeling method, selected based on the availability of the occupant historical indices measurements in a neutral environment, and use the time-series of the hot and cold indices to define corrections to HVAC system operations in the form of setpoint constraints. To evaluate the efficacy of our proposed approach in responding to thermal stimuli, we designed a series of controlled experiments to simulate exposure to cold and hot environments. While applying personalized modeling showed an acceptable average accuracy of 91.3%, the generalized model’s average accuracy was only 65.2%. This shows the importance of having access to physiological records in modeling and assessing comfort. We also found that individual differences should be considered in selecting the cooling and heating rates when some knowledge of the occupant’s overall thermal preference is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seminar 44, Innovative and New Ideas: BAS Best Practices for O&M Success Coaching Operators for Effective Use of Data

Regardless of a building’s inherent energy efficiency, changes in building operator behavior reduces building energy consumption by 14% on average. Giving operators readily available and easily digestible data regarding the performance of their HVAC systems increases the likelihood of energy saving actions. Many Building Automations Systems do not excel at creating user-friendly time series trend charts. This presentation presents examples of a solution to this issue developed under an award by the Department of Energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗