At least 19 records

Evolving HPC and Application Design Toward a Coupled Data Assimilation System at NASA Suitable for Emerging Exascale Platforms

The prediction capabilities of global models have continuously evolved from the traditional medium-range global weather prediction application to span scales in support of hourly prediction of convective scale storms to seasonal Earth system prediction. This evolution has increased the demands on the system infrastructure design and workflow to achieve the required performance on modern high-performance computing (HPC) platforms. The planned evolution of the Goddard Earth Observing System (GEOS) modeling and assimilation system will stress the capabilities of conventional HPC overwhelming the available compute cycles at the NASA Center for Climate Simulation (NCCS) at the NASA Goddard Space Flight Center in the coming 5-10 years. This has led to the re-design of key elements of the assimilation and modeling systems to achieve significant gains in performance on anticipated Exacale platforms. The transition of the assimilation system to the Joint Effort for Data assimilation Integration (JEDI) framework has positioned GEOS to exploit new efficient algorithms for data assimilation (DA) in a fully-coupled Earth system context. The suitability of the GEOS model to leverage a domain specific language (DSL) approach and artificial intelligence (AI) is being explored to accelerate computational performance and data exchange efficiency of the coupled Earth system model. The storage and processing of large data volumes produced by these advance systems is being redesigned with a data-centric cloud-based approach. We will highlight the recent efforts in these areas and emphasize the demand for further development and re-design to achieve the science objectives in support of NASA's Earth system modeling and assimilation missions.

Putman, Bill

Position Paper - pFLogger: The Parallel Fortran Logging framework for HPC Applications

In the context of high performance computing (HPC), software investments in support of text-based diagnostics, which monitor a running application, are typically limited compared to those for other types of IO. Examples of such diagnostics include reiteration of configuration parameters, progress indicators, simple metrics (e.g., mass conservation, convergence of solvers, etc.), and timers. To some degree, this difference in priority is justifiable as other forms of output are the primary products of a scientific model and, due to their large data volume, much more likely to be a significant performance concern. In contrast, text-based diagnostic content is generally not shared beyond the individual or group running an application and is most often used to troubleshoot when something goes wrong. We suggest that a more systematic approach enabled by a logging facility (or logger) similar to those routinely used by many communities would provide significant value to complex scientific applications. In the context of high-performance computing, an appropriate logger would provide specialized support for distributed and shared-memory parallelism and have low performance overhead. In this paper, we present our prototype implementation of pFlogger a parallel Fortran-based logging framework, and assess its suitability for use in a complex scientific application.

Fortran

POSITION PAPER - pFLogger: The Parallel Fortran Logging Framework for HPC Applications

In the context of high performance computing (HPC), software investments in support of text-based diagnostics, which monitor a running application, are typically limited compared to those for other types of IO. Examples of such diagnostics include reiteration of configuration parameters, progress indicators, simple metrics (e.g., mass conservation, convergence of solvers, etc.), and timers. To some degree, this difference in priority is justifiable as other forms of output are the primary products of a scientific model and, due to their large data volume, much more likely to be a significant performance concern. In contrast, text-based diagnostic content is generally not shared beyond the individual or group running an application and is most often used to troubleshoot when something goes wrong. We suggest that a more systematic approach enabled by a logging facility (or 'logger') similar to those routinely used by many communities would provide significant value to complex scientific applications. In the context of high-performance computing, an appropriate logger would provide specialized support for distributed and shared-memory parallelism and have low performance overhead. In this paper, we present our prototype implementation of pFlogger - a parallel Fortran-based logging framework, and assess its suitability for use in a complex scientific application.

Clune, Thomas L.

Methodology and Application of HPC I/O Characterization with MPIProf and IOT

Combining the strengths of MPIProf and IOT, an efficient and systematic method is devised for I/O characterization at the per-job, per-rank, per-file and per-call levels of HPC programs running on the NASA Advanced Supercomputing Center. This method is applied to answer four I/O questions in this paper. A total of 13 MPI programs and 15 cases, ranging from 24 to 5968 ranks, are analyzed to establish the I/O landscape from answers to the four questions. Four of the 13 programs use MPI I/O and the behavior of their collective writes depends on the specific implementation of the MPI library used. The SGI MPT library, the prevailing MPI library for our systems, was found to gather small writes from a large number of ranks to perform larger writes by a small subset of collective buffering ranks. The number of collective buffering ranks invoked by MPT depends on the Lustre stripe count and the number of nodes used for the run. A demonstration of varying the stripe count to achieve double-digit speedup of one program's I/O was presented. Another program, which concurrently opens private files by all ranks and could potentially create a heavy load on the Lustre servers, was identified. The ability to systematically characterize I/O for a large number of programs running on a supercomputer, seek I/O optimization opportunity and identify programs that could cause a high load and instability on the filesystems is important for pursuing exascale in a real production environment.

Characterization

Improvement in HPC performance through HIPPI RAID storage

In 1986, RAID (redundant array of inexpensive (or independent) disks) technology was introduced as a viable solution to the I/O bottleneck. A number of different RAID levels were defined in 1987 by the Computer Science Division (EECS) University of California, Berkeley, each with specific advantages and disadvantages. With multiple RAID options available, taking advantage of RAID technology required matching particular RAID levels with specific applications. It was not possible to use one RAID device to address all applications. Maximum Strategy's Gen 4 Storage Server addresses this issue with a new capability called programmable RAID level partitioning. This capability enables users to have multiple RAID levels coexist on the same disks, thereby providing the versatility necessary for multiple concurrent applications.

Homan, Blake

Role of HPC in Advancing Computational Aeroelasticity

On behalf of the High Performance Computing and Modernization Program (HPCMP) and NASA Advanced Supercomputing Division (NAS) a study is conducted to assess the role of supercomputers on computational aeroelasticity of aerospace vehicles. The study is mostly based on the responses to a web based questionnaire that was designed to capture the nuances of high performance computational aeroelasticity, particularly on parallel computers. A procedure is presented to assign a fidelity-complexity index to each application. Case studies based on major applications using HPCMP resources are presented.

Guruswamy, Guru P.

Virtualized Infiniband: Enabling HPC in the Cloud

Presentation describes virtualized infiniband and how it enables doing high performance computing level processing and file systems in a cloud environment. Generic benchmarks are included.

virtualization

Computational Fluid Dynamics Ventilation Study for the Human Powered Centrifuge at the International Space Station

The Human Powered Centrifuge (HPC) is a facility that is planned to be installed on board the International Space Station (ISS) to enable crew exercises under the artificial gravity conditions. The HPC equipment includes a "bicycle" for long-term exercises of a crewmember that provides power for rotation of HPC at a speed of 30 rpm. The crewmember exercising vigorously on the centrifuge generates the amount of carbon dioxide of about two times higher than a crewmember in ordinary conditions. The goal of the study is to analyze the airflow and carbon dioxide distribution within Pressurized Multipurpose Module (PMM) cabin when HPC is operating. A full unsteady formulation is used for airflow and CO2 transport CFD-based modeling with the so-called sliding mesh concept when the HPC equipment with the adjacent Bay 4 cabin volume is considered in the rotating reference frame while the rest of the cabin volume is considered in the stationary reference frame. The rotating part of the computational domain includes also a human body model. Localized effects of carbon dioxide dispersion are examined. Strong influence of the rotating HPC equipment on the CO2 distribution detected is discussed.

Son, Chang H.

A Methodology to Assess the Capability of Engine Designs to Meet Closed-loop Performance and Operability Requirements

Designing a closed-loop controller for an engine requires balancing trade-offs between performance and operability of the system. One such trade-off is the relationship between the 95% response time and minimum high-pressure compressor (HPC) surge margin (SM) attained during acceleration from idle to takeoff power. Assuming a controller has been designed to meet some specification on response time and minimum HPC SM for a mid-life (nominal) engine, there is no guarantee that these limits will not be violated as the engine ages, particularly as it reaches the end of its life. A characterization for the uncertainty in this closed-loop system due to aging is proposed that defines elliptical boundaries to estimate worst-case performance levels for a given control design point. The results of this characterization can be used to identify limiting design points that bound the possible con- troller designs yielding transient results that do not exceed specified limits in response time or minimum HPC SM. This characterization involves performing Monte Carlo simulation of the closed-loop system with controller constructed for a set of trial design points and developing curve fits to describe the size and orientation of each ellipse; a binary search procedure is then employed that uses these fits to identify the limiting design point. The method is demonstrated through application to a generic turbofan engine model in closed- loop with a simplified controller; it is found that the limit for which each controller was designed was exceeded by less than 4.76%. Extension of the characterization to another trade-off, that between the maximum high-pressure turbine (HPT) entrance temperature and minimum HPC SM, showed even better results: the maximum HPT temperature was estimated within 0.76%. Because of the accuracy in this estimation, this suggests another limit that may be taken into consideration during design and analysis. It also demonstrates the extension of the characterization to other attributes that contribute to the performance or operability of the engine. Metrics are proposed that, together, provide information on the shape of the trade-off between response time and minimum HPC SM, and how much each varies throughout the life cycle, at the limiting design points. These metrics also facilitate comparison of the expected transient behavior for multiple engine models.

engine control

A Methodology to Assess the Capability of Engine Designs to Meet Closed-Loop Performance and Operability Requirements

Designing a closed-loop controller for an engine requires balancing trade-offs between performance and operability of the system. One such trade-off is the relationship between the 95 percent response time and minimum high-pressure compressor (HPC) surge margin (SM) attained during acceleration from idle to takeoff power. Assuming a controller has been designed to meet some specification on response time and minimum HPC SM for a mid-life (nominal) engine, there is no guarantee that these limits will not be violated as the engine ages, particularly as it reaches the end of its life. A characterization for the uncertainty in this closed-loop system due to aging is proposed that defines elliptical boundaries to estimate worst-case performance levels for a given control design point. The results of this characterization can be used to identify limiting design points that bound the possible controller designs yielding transient results that do not exceed specified limits in response time or minimum HPC SM. This characterization involves performing Monte Carlo simulation of the closed-loop system with controller constructed for a set of trial design points and developing curve fits to describe the size and orientation of each ellipse; a binary search procedure is then employed that uses these fits to identify the limiting design point. The method is demonstrated through application to a generic turbofan engine model in closed-loop with a simplified controller; it is found that the limit for which each controller was designed was exceeded by less than 4.76 percent. Extension of the characterization to another trade-off, that between the maximum high-pressure turbine (HPT) entrance temperature and minimum HPC SM, showed even better results: the maximum HPT temperature was estimated within 0.76 percent. Because of the accuracy in this estimation, this suggests another limit that may be taken into consideration during design and analysis. It also demonstrates the extension of the characterization to other attributes that contribute to the performance or operability of the engine. Metrics are proposed that, together, provide information on the shape of the trade-off between response time and minimum HPC SM, and how much each varies throughout the life cycle, at the limiting design points. These metrics also facilitate comparison of the expected transient behavior for multiple engine models.

systems analysis

Conceptual Design of a Two Spool Compressor for the NASA Large Civil Tilt Rotor Engine

This paper focuses on the conceptual design of a two spool compressor for the NASA Large Civil Tilt Rotor engine, which has a design-point pressure ratio goal of 30:1 and an inlet weight flow of 30.0 lbm/sec. The compressor notional design requirements of pressure ratio and low-pressure compressor (LPC) and high pressure ratio compressor (HPC) work split were based on a previous engine system study to meet the mission requirements of the NASA Subsonic Rotary Wing Projects Large Civil Tilt Rotor vehicle concept. Three mean line compressor design and flow analysis codes were utilized for the conceptual design of a two-spool compressor configuration. This study assesses the technical challenges of design for various compressor configuration options to meet the given engine cycle results. In the process of sizing, the technical challenges of the compressor became apparent as the aerodynamics were taken into consideration. Mechanical constraints were considered in the study such as maximum rotor tip speeds and conceptual sizing of rotor disks and shafts. The rotor clearance-to-span ratio in the last stage of the LPC is 1.5% and in the last stage of the HPC is 2.8%. Four different configurations to meet the HPC requirements were studied, ranging from a single stage centrifugal, two axi-centrifugals, and all axial stages. Challenges of the HPC design include the high temperature (1,560deg R) at the exit which could limit the maximum allowable peripheral tip speed for centrifugals, and is dependent on material selection. The mean line design also resulted in the definition of the flow path geometry of the axial and centrifugal compressor stages, rotor and stator vane angles, velocity components, and flow conditions at the leading and trailing edges of each blade row at the hub, mean and tip. A mean line compressor analysis code was used to estimate the compressor performance maps at off-design speeds and to determine the required variable geometry reset schedules of the inlet guide vane and variable stators that would result in the transonic stages being aerodynamically matched with high efficiency and acceptable stall margins based on user specified maximum levels of rotor diffusion factor and relative velocity ratio.

Veres, Joseph P.

CFD Ventilation Study for the Human Powered Centrifuge at the International Space Station

The Human Powered Centrifuge (HPC) is a hyper gravity facility that will be installed on board the International Space Station (ISS) to enable crew exercises under the artificial gravity conditions. The HPC equipment includes a bicycle for long-term exercises of a crewmember that provides power for rotation of HPC at a speed of 30 rpm. The crewmember exercising vigorously on the centrifuge generates the amount of carbon dioxide of several times higher than a crewmember in ordinary conditions. The goal of the study is to analyze the airflow and carbon dioxide distribution within Pressurized Multipurpose Module (PMM) cabin. The 3D computational model included PMM cabin. The full unsteady formulation was used for airflow and CO2 transport modeling with the so-called sliding mesh concept is considered in the rotating reference frame while the rest of the cabin volume is considered in the stationary reference frame. The localized effects of carbon dioxide dispersion are examined. Strong influence of the rotating HPC equipment on the CO2 distribution is detected and discussed.