Engineering PapersSearch

SEARCH · Engineering Papers

Results for “HOT ELECTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electron-phonon relaxation in hot-electron detectors below 1 K

Recently proposed submillimeter hot-electron direct detecors based on normal metals and superconductors rely on the thermal coupling between electrons and phonons. The sensitivity of the detectors can be greatly enhanced if the coupling is made very weak at subkelvin temperatures.

hot-electron

A Low-Noise NbTiN Hot Electron Bolometer Mixer

Hot electron bolometer (HEB) mixer elements, based on niobium titanium nitride (NbTiN) thin film technology, have been fabricated on crystalline quartz substrates over a 20 nm thick AlN buffer layer. The film was patterned by optical lithography, yielding bolometer elements that measure about 1 micrometer long and between 2 and 12 micrometers wide. These mixer chips were mounted in a fixed-tuned waveguide mixer block, and tested in the 600 and 800 GHz frequency range. The 3-dB output bandwidth of these mixers was determined to be about 2.5 GHz and we measured a receiver noise temperature of 270 K at 630 GHz using an intermediate frequency of 1.5 GHz. The receiver has excellent amplitude stability and the noise temperature measurements are highly repeatable. An 800 GHz receiver incorporating one of these mixer chips has recently been installed at the Sub-Millimeter Telescope in Arizona for field test and for astronomical observations.

Tong, C. Edward

Characterization of MgB2 Superconducting Hot Electron Bolometers

Hot-Electron Bolometer (HEB) mixers have proven to be the best tool for high-resolution spectroscopy at the Terahertz frequencies. However, the current state of the art NbN mixers suffer from a small intermediate frequency (IF) bandwidth as well as a low operating temperature. MgB2 is a promising material for HEB mixer technology in view of its high critical temperature and fast thermal relaxation allowing for a large IF bandwidth. In this work, we have fabricated and characterized thin-film (approximately 15 nanometers) MgB2-based spiral antenna-coupled HEB mixers on SiC substrate. We achieved the IF bandwidth greater than 8 gigahertz at 25 degrees Kelvin and the device noise temperature less than 4000 degrees Kelvin at 9 degrees Kelvin using a 600 gigahertz source. Using temperature dependencies of the radiation power dissipated in the device we have identified the optical loss in the integrated microantenna responsible as a cause of the limited sensitivity of the current mixer devices. From the analysis of the current-voltage (IV) characteristics, we have derived the effective thermal conductance of the mixer device and estimated the required local oscillator power in an optimized device to be approximately 1 microwatts.

Superconducting Devices

Microwave Mixing and if Bandwidth in Sub-Micron Long High -T(sub c) Hot - Electron Bolometers

The hot-electron bolometer (HEB) mixer made from a high-T(sub c) superconductor (HTS) was introduced recently as a competing alternative to a Schottky mixer. The HEB mixer would require 100-times less LO power and thus would be a desirable candidate for long-term observational missions such as atmospheric remote-sensing and planetary science. The required cooling temperatures between 65 K and 75 K can be achieved with available space-qualified coolers or even with passive radiative coolers.

Harnack, Oliver

Efficient Size-Dependent Hot Electron Transfer from Au to TiO 2 Nanoparticles

Harvesting of plasmon-induced hot carriers at the metal/semiconductor interface offers a promising and innovative avenue for solar energy conversion. However, their practical implementation is often hampered by their limited efficiencies. Herein, we have demonstrated a highly efficient plasmonic hot electron transfer with a quantum efficiency (QE) of up to 57 ± 4% from 5.25 nm Au nanoparticles (NPs) to TiO 2 films under 400 nm ultrafast laser excitation. The observed hot electron transfer QEs decrease at larger particle sizes, to 20% for 9.1 nm Au, and show negligible changes with excitation wavelengths at 400, 500, and 600 nm. Analysis of the size and excitation wavelength dependent hot electron transfer QEs suggests they contain contributions of interband absorption, indirect plasmon-induced hot electron transfer (PHET), and direct plasmon-induced interfacial charge transfer transition (PICTT) pathways, and QEs of all three pathways increase at smaller Au size. Our result suggests that reducing plasmon particle sizes is a promising approach for efficient plasmonic hot-carrier extraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Hot electron preheat effects in two-photon polymerization plastic lattice laser-driven shock-tube experiments on the OMEGA laser

We present simulations of Omega shock tube experiments designed to investigate hot electron preheat effects in 3D-printed, two-photon polymerization (2PP) plastic lattices. Preheat is inferred in the experiments from the expansion of a plastic witness disk embedded in the lattice. Using the Eulerian radiation-hydrodynamics code xRAGE, we model shock propagation and preheat from both radiative and hot electron energy sources to evaluate their relative impact. To simulate the transport of laser-generated hot electrons, the nonlocal electron heat transport model proposed by Schurtz, Nicolaï, and Busquet (SNB) is extended with a hot electron source term and an energy cascade algorithm. We explore how variations in ablator, lattice geometry, and laser drive affect the shock velocity and witness disk expansion. Simulations show that the inclusion of a 5 μm gold layer reduces shock pressure by 60% and shock speeds by 30%–40% but does not significantly reduce the hot electron preheat, and that different lattice geometries lead to enhanced shock velocities—up to 40% faster than in homogeneous foams. However, radiative and conductive preheat from classical mechanisms alone fail to match experiment. By including a hot electron source term, we reproduce experimental observables such as disk expansion rates and spatial radiographic features. We find that a hot electron population corresponding to 4%–8% of the incident laser energy with T hot = 50 keV produces expansion which agrees with the experimental data, suggesting hot electron preheat is the most plausible explanation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Effects of a magnetic field on hot electron generation from laser-plasma instabilities

We performed two-dimensional simulations of turbulent laser-plasma instabilities in the presence and absence of external magnetic fields using the Laser Plasma Simulation Environment (LPSE) code. The results demonstrate that, in the presence of a magnetic field, the transition from ballistic to gyrating electron motion enhances the energy transfer from electron plasma waves to the electron population. Although stronger magnetic fields produce a larger population of hot electrons, these electrons tend to remain confined near the quarter-critical density, where the instabilities also localize, thereby reducing the potential for hot electron transport deeper into the target. Additionally, we present a scaling analysis that quantifies hot electron generation as a function of plasma electron temperature, density scale length, and applied magnetic field strength. These findings may have important applications for controlling hot electron flux and mitigating preheat in inertial confinement fusion targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

A Superconducting Hot Electron Bolometer Mixer for 530 GHz

This paper describes a superconducting hot electron bolometer mixer that uses diffusion rather than interactions with phonons as a cooling mechanism for the hot electrons. The bolometer is a 0.14 µm; wide niobium microbridge with a length less than 0.5 µm;. The submicron length ensures rapid diffusion of the hot electrons into contacting gold films. This mechanism is believed to be fast enough to allow mixer operation with intermediate frequencies of several GHz. An electron cooling time of 55 ps is inferred from DC resistance versus temperature measurements, indicating a roll-off frequency close to 3 GHz. Initial receiver measurements using a two-tuner waveguide mixer confirm heterodyne mixing at 532 GHz with an intermediate frequency of 1.4 GHz.

bolometer

Record Low NEP in the Hot-Electron Titanium Nanobolometers

We are developing hot-electron superconducting transition-edge sensors (TES) capable of counting THz photons and operating at T = 0.3K. We fabricated superconducting Ti nanosensors with Nb contacts with a volume of approx. 3x10(exp -3) cu microns on planar Si substrate and have measured the thermal conductance due to the weak electron-phonon coupling in the material G = 4x10(exp -14) W/K at 0.3 K. The corresponding phonon-noise NEP = 3x10(exp -19) W/Hz(sup 1/2). Detection of single optical photons (1550nm and 670nm wavelength) has been demonstrated for larger devices and yielded the thermal time constants of 30 microsec at 145 mK and of 25 microsec at 190 mK. This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with (nu) > 1 THz where NEP approx. 3x10(exp -20) W/Hz(sup 1/2) is needed for spectroscopy in space.

transition edge sensors

Effect of hot electrons on the polar wind

A semikinetic model is used to describe the steady state collisionless flow of H(+), O(+), and electrons along diverging geomagnetic field lines in the high-latitude topside ionosphere. The effect that hot electron populations have on the polar wind is emphasized. Several such populations are considered, including the polar rain, polar showers, and polar squall. Hot electron densities and temperatures are calculated from the characteristic energy and flux measurements. The results indicate that the hot/cold electron temperature ratio varies from 10 to 10,000 and that the hot/cold electron density ratio varies from 0.001 to 0.1 at the baropause. For higher hot electron temperatures and a greater percentage of hot electrons, there is a discontinuity in the kinetic solution, which indicates the presence of a sharp transition corresponding to a contact surface between the hot and cold electrons. Along this surface, a double-layer potential barrier exists which reflects the cold ionospheric electrons and prevents their penetrations to higher altitudes.

Barakat, A. R.

A Hot-electron Direct Detector for Radioastronomy

A hot-electron transition-edge superconducting bolometer with adjustable thermal relaxation speed is proposed. The bolometer contacts are made from a superconductor with high critical temperature which blocks the thermal diffusion of hot carriers into the contacts. Thus electron-phonon interaction is the only mechanism for heat removal. The speed of thermal relaxation for hot electrons in a nanometer-size superconducting bolometer with T(sub c) = 100-300 mK is controlled by the elastic electron mean free path l. The relaxation rate behaves as T(sup 4)l at subkelvin temperatures and can be reduced by a factor of 10-100 by decreasing 1. Then an antenna- or wave guide-coupled bolometer with a time constant approx. = 10(exp -3) to 10(exp -4) s will exhibit photon-noise limited performance at millimeter and submillimeter wavelengths. The bolometer will have a figure-of-merit NEPtau = 10(exp -22) - 10(exp -21) W/Hz at 100 mK which is 10(exp 3) to 10(exp 4) times better (ie: smaller) than that of a state-of-the-art bolometer. A tremendous increase in speed and sensitivity will have a significant impact for observational mapping applications.

Karasik, Boris S.

Electrical NEP in Hot-Electron Titanium Superconducting Bolometers

We are presenting the current progress on the titanium (Ti) hot-electron transition-edge devices. The ultimate goal of this work is to develop a submillimeter Hot-Electron Direct Detector (HEDD) with the noise equivalent power NEP = 10(sup -1) - 10(sup -20) W/Hz(sup 1/2) for the moderate resolution spectroscopy and Cosmic Microwave Background (CMB) studies on future space telescope (e.g., SPICA, SAFIR, SPECS, CMBPol) with cryogenically cooled (approximately 4-5 K) mirrors. Recently, we have achieved the extremely low thermal conductance (approximately 20 fW/K at 300 mK and approximately 0.1 fW/K at 40 mK) due to the electron-phonon decoupling in Ti nanodevices with niobium (Nb) Andreev contacts. This thermal conductance translates into the "phonon-noise" NEP approximately equal to 3 x 10(sup -21) W/Hz(sup 1/2) at 40 mK and NEP approximately equal to 3 x 10(sup -19) W/Hz(sup 1/2) at 300 mK. These record data indicate the great potential of the hot-electron detector for meeting many application needs. Beside the extremely low phonon-noise NEP, the nanobolometers have a very low electron heat capacitance that makes them promising as detectors of single THz photons. As the next step towards the practical demonstration of the HEDD, we fabricated and tested somewhat larger than in Ref.1 devices (approximately 6 micrometers x 0.35 micrometers x 40 nm) whose critical temperature is well reproduced in the range 300-350 mK. The output electrical noise measured in these devices with a low-noise dc SQUID is dominated by the thermal energy fluctuations (ETF) aka "phonon noise". This indicates the high electrothermal loop gain that effectively suppresses the contributions of the Johnson noise and the amplifier (SQUID) noise. The electrical NEP = 6.7 x 10(sup -18) W/Hz(sup 1/2) derived from these measurements is in good agreement with the predictions based on the thermal conductance data. The very low NEP and the high speed (approximately microns) are a unique combination not found in other detectors.

transition-edge sensor

THz Hot-Electron Photon Counter

We present a concept for the hot-electron transition-edge sensor capable of counting THz photons. The main need for such a sensor is a spectroscopy on future space telescopes where a background limited NEP approx. 10(exp -20) W/H(exp 1/2) is expected at around 1 THz. Under these conditions, the rate of photon arrival is very low and any currently imaginable detector with sufficient sensitivity will operate in the photon counting mode. The Hot-Electron Photon Counter based on a submicron-size Ti bridge has a very low heat capacity which provides a high enough energy resolution (approx.140 GHz) at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range would be approx. 30 dB. The sensor couples to radiation via a planar antenna and is read by a SQUID amplifier or by a 1-bit RSFQ ADC. A compact array of the antenna-coupled counters can be fabricated on a silicon wafer without membranes.

radiation detectors