Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HLC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development and Flight Demonstration of a HUMS-Based Helicopter Limit Cueing (HLC) System

A prototype helicopter limit cueing (HLC) system was designed, installed, and evaluated in flight test in early 2002. This paper describes the design, cueing methodology, and interim flight test results of this project. The system described in this paper used available Health and Usage Monitoring System (HUMS) parameters and a simple and cost-effective mechanical spring/electric motor combination to achieve a tactile cue that warned the pilot of impending exceedences of the transmission torque limit. Three high-workload maneuvers were used to evaluate the prototype HLC system. Results indicate that with an appropriate design, inadvertent over-torque events could be eliminated with a HLC system while reducing pilot workload.

Augustin, M.↗

Induction of Three-Dimensional Growth of Human Liver Cells in Simulated Microgravity

We previously reported that a NASA-developed bioreactor that simulates microgravity environment and creates the unique environment of low shear force and high-mass transfer is conducive for maintaining long term 3-D cell cultures of functional hepatocytes (60 days). However, significant further expansion of liver mass, or the remodeling of liver in vitro was jeopardized by the appearance of apoptotic zones in the center of large cell aggregates. To optimize oxygenation and nutritional uptake within growing cellular aggregates we cultured primary human liver cells (HLC) in a bioreactor in the presence or absence of microcarriers and biodegradable scaffolds. Also, to promote angiogenesis, HLC were cultured with or without microvascular endothelial cells. HLC were harvested from human livers by collagenase perfusion. While microcarriers did not affect cell growth, HLC cultured with biodegradable scaffolds made from polyglycolic acid (PGA) formed aggregates up to 3 cm in length. Culturing cells with PGA scaffolds increased the efficiency of cell self-assembly and the formation of larger cell aggregates. Based on histological evaluation it appears that the degree of apoptotic cells was diminished as compared to cultures without scaffolds. Histology of HLC with PGA-scaffolds revealed cell distribution between the fibers of the scaffolds, and cell-cell and cell-fiber interactions. Analyses of HLC spheroids revealed tissue-like structures comprised of hepatocytes, biliary epithelial cells and/or progenitor liver cells that were arranged as bile duct-like structures along nascent vascular sprouts. Electron microscopy revealed groups of cohesive hepatocytes and bile canaliculi with multiple microvilli and tight cellular junctions. Hepatocytes were further organized into tight clusters surrounded by complex stromal structures and reticulin fibers. Also, we observed higher levels of albumin mRNA expression when hepatocytes were co-cultured with endothelial cells. To evaluate viability and microsomal deethylation activity of hepatocytes we assessed the metabolism of midazolam by gas chromatography. Samples that were collected from HLC cultured in the bioreactor contained higher levels of midazolam metabolites (1-OH-midazolam and 4-OH-midazolam) than samples collected from conventional cultures. In summary, we have shown that co-culture of HLC with endothelial cells and/or culturing in the presence of PGA scaffolds provides additional advantages in maintaining functional activity of 3-D hepatocyte cultures that resemble liver tissue. This cell culture system may facilitate studies of liver regeneration and cell-to-cell interactions that occur in vivo and suggest the feasibility of using this approach for pre-clinical metabolic screening of novel drug candidates.

Pellis, Neal R.↗

Optimization of Lyot Coronagrah focal plane masks for improved low-order wavefront sensing

The WFIRST Coronagraph uses a Low-Order Wavefront Sensing and Control (LOWFS/C) subsystem to stabilize the stellar wavefront. This is true for the Hybrid Lyot Coronagraph (HLC), the Shaped Pupil Coronagraph (SPC) spectrograph, and the SPC wide field of view modes. For the SPC spectrograph, we have found via modeling and simulations that a focal plane mask (FPM) with an elliptical phase dimple can reduce the LOWFS errors significantly compared to the conventional, circular phase dimple. For HLC designs, we concurrently optimized the FPM parameters and deformable mirror shapes using our open-source software toolbox, the Fast Linearized Coronagraph Optimizer (FALCO). This process resulted in new FPMs with non-uniform central-area phase modulation. We have found in numerical simulations that such FPMs still provide sufficient LOWFS performance. In this paper, we will present the LOWFS performance for several new HLC and SPC FPM designs.

Riggs, A.J. Eldorado↗

Zernike Wavefront Sensor Modeling Development for LOWFS on WFIRST-AFTA

WFIRST-AFTA design makes use of an existing 2.4m telescope for direct imaging of exoplanets. To maintain the high contrast needed for the coronagraph, wavefront error (WFE) of the optical system needs to be continuously sensed and controlled. Low Order Wavefront Sensing (LOWFS) uses the rejected starlight from an immediate focal plane to sense wavefront changes (mostly thermally induced low order WFE) by combining the LOWFS mask (a phase plate located at the small center region with reflective layer) with the starlight rejection masks, i.e. Hybrid Lyot Coronagraph (HLC)'s occulter or Shaped Pupil Coronagraph (SPC)'s field stop. Zernike wavefront sensor (ZWFS) measures phase via the phase-contrast method and is known to be photon noise optimal for measuring low order aberrations. Recently, ZWFS was selected as the baseline LOWFS technology on WFIST/AFTA for its good sensitivity, accuracy, and its easy integration with the starlight rejection mask. In this paper, we review the theory of ZWFS operation, describe the ZWFS algorithm development, and summarize various numerical sensitivity studies on the sensor performance. In the end, the predicted sensor performance on SPC and HLC configurations are presented.

Zernike phase contrast↗

WFIRST/AFTA Coronograph Contrast Performance Sensitivity Studies: Simulation Versus Experiment

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory, we have investigated through modeling and simulations the sensitivity of dark hole contrast in a Hybrid Lyot Coronagraph (HLC) for several error cases, including lateral and longitudinal translation errors of two deformable mirrors, DM1 and DM2, lateral and/or longitudinal translation errors of an occulting mask and a Lyot-Stop, clocking errors of DM1 and DM2, and the mismatch errors between the testbed and the model sensitivity matrices. We also investigated the effects of a control parameter, namely the actuator regularization factor, on the control efficiency and on the final contrast floor. We found several error cases which yield contrast results comparable to that observed on the HLC testbed. We present our findings in this paper.

Coronagraphy↗

Shaped Pupil Coronagraphy for WFIRST: High-Contrast Broadband Testbed Demonstration

The Shaped Pupil Coronagraph (SPC) is one of the two operating modes of the WFIRST (Wide-Field InfraRed Survey Telescope) coronagraph instrument. The SPC provides starlight suppression in a pair of wedge-shaped regions over an 18 percent bandpass, and is well suited for spectroscopy of known exoplanets. To demonstrate this starlight suppression in the presence of expected on-orbit input wavefront disturbances, we have recently built a dynamic testbed at JPL (Jet Propulsion Lab.) analogous to the WFIRST fight instrument architecture, with both Hybrid Lyot Coronagraph (HLC) and SPC architectures and a Low Order Wavefront Sensing and Control (LOWFS/C) subsystem to apply, sense, and correct dynamic wavefront disturbances. We present our best up-to-date results of the static SPC mode demonstration from the testbed, along with model comparisons and performance under realistic dynamical conditions. HLC results will be reported separately.

Cady, Eric↗

Sensitivity of WFIRST Coronagraph Broadband Contrast Performance to DM Actuator Errors

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory (JPL), we have investigated the sensitivity of a Hybrid Lyot Coronagraph (HLC) broadband contrast performance to DM actuator errors and actuator limits. Considered case include drifts in actuator gains or actuator response curves, paired actuators, as well as the limits imposed by a neighboring-actuator rule. Actual data about the actuator drifts and the knowledge about the paired-actuators obtained in several DM characterization experiments conducted at JPL, as well as the neighboring-actuator rule implemented on the OMC testbed were used in simulations. We obtained good agreement between the model prediction and the testbed measurement in terms of static HLC contrast floor and contrast chromaticity.

Sidick, Erkin↗

WFIRST/AFTA coronograph contrast performance sensitivity studies: simulation versus experiment

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory, we have investigated through modeling and simulations the sensitivity of dark hole contrast in a Hybrid Lyot Coronagraph (HLC) for several error cases, including lateral and longitudinal translation errors of two deformable mirrors, DM1 and DM2, lateral and/or longitudinal translation errors of an occulting mask and a Lyot-Stop, clocking errors of DM1 and DM2, and the mismatch errors between the testbed and the model sensitivity matrices. We also investigated the effects of a control parameter, namely the actuator regularization factor, on the control efficiency and on the final contrast floor. We found several error cases which yield contrast results comparable to that observed on the HLC testbed. We present our findings in this paper.

Nemati, Bijan↗

WFIRST Coronagraph: Digging Dark-Holes with Partially Corrected Pupil Phase

The WFIRST coronagraph employs two sequential deformable mirrors to compensate for phase and amplitude errors in the coronagraph optical system. In such a system the actuators of the deformable mirrors would be used for two purposes: To flatten the overall wavefront errors at a system pupil, and to create "dark-holes". The actuators have limited stroke ranges. Therefore, if the pupil phase errors are relatively large, flattening them completely could use up a significant portion of the actuator stroke, sometimes leaving insufficient stroke for creating the dark-holes. We have investigated the impact of partially-corrected pupil phase errors on a Hybrid Lyot Coronagraph (HLC) broadband contrast performance. The predicted broadband contrast floor and the contrast chromaticity agree well with those measured on the HLC testbed.

Poberezhskiy, Ilya↗

Hybrid Lyot Coronagraph for WFIRST: High Contrast Testbed Demonstration in Flight-like Low Flux Environment

In order to validate required operation of the proposed Wide-Field InfraRed Survey Telescope (WFIRST) coronagraph instrument, we have built a testbed in Jet Propulsion Laboratory (JPL), which is analogous to the baseline WFIRST coronagraph instrument architecture. Since its birth in 2016, this testbed, named as Occulting Mask Coronagraph (OMC) testbed, has demonstrated several crucial technological milestones: Broadband high contrast demonstration in both Hybrid Lyot Coronagraph (HLC) and Shape Pupil Coronagraph (SPC) modes while the Low Order Wavefront Sensing and Control (LOWFS/C) subsystem senses and corrects the dynamic flight-like wavefront disturbances. In this paper, we present up-to-date progress of HLC mode demonstration in the OMC testbed. While injecting the flight-like low photon flux starlight with expected Line of Sight (LoS) and Wavefront Error (WFE) perturbation to the OMC testbed, we demonstrate generating high contrast dark hole images. We first study the expected photon flux in actual flight environment, and estimate detection noise and estimation accuracy of the complex electric field if the wavefront sensing algorithm is used based on the pair-wise difference imaging. Then, we introduce our improved scheme to mitigate this photon-starved flight-like low flux environment. As a result, we generate a dark hole that meets the WFIRST raw contrast requirements using the 2nd magnitude star light. We establish the key ideas, describe test setups, and demonstrate test results with data analysis.

Wilson, Daniel↗

ROMAN CGI Testbed WFSC Modeling and Validation

Optical diffraction and wavefront sensing and control (WFSC) models validated against the high-fidelity Roman Space Telescope Coronagraph Instrument (CGI) testbed play a key role in mask design selection and the verification of many requirements that cannot be accomplished until the observatory is in orbit. We have been steadily improving our model fidelity for the as-built CGI testbed system, demonstrating recently good agreement between measurements and model predictions while validating the Hybrid Lyot Coronagraph’s (HLC) performance using the in-orbit high order wavefront sensing and control (HOWFSC) operational scenario. We present modeling and testbed validation results that explain the reason many testbed WFSC iterations were needed for HLC in the past. A new, direct application of model-generated deformable mirror (DM) solutions has since been successfully demonstrated on the testbed with significant speed and performance improvement. The benefit of using such a solution opens up new model-based WFSC approaches for CGI. This can greatly reduce flight risk from potentially insufficient ground solution generation due to schedule or cost constraints or from unexpected post-delivery changes.

Poberezhskiy, Ilya↗

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST-AFTA

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) is a lenslet array based integral field spectrometer (IFS) designed for high contrast imaging of extrasolar planets. PISCES will be used to advance the technology readiness of the high contrast IFS baselined on the Wide-Field InfraRed Survey Telescope/Astrophysics Focused Telescope Assets (WFIRST-AFTA) coronagraph instrument. PISCES will be integrated into the high contrast imaging testbed (HCIT) at the Jet Propulsion Laboratory (JPL) and will work with both the Hybrid Lyot Coronagraph (HLC) and the Shaped Pupil Coronagraph (SPC) configurations. We discuss why the lenslet array based IFS was selected for PISCES. We present the PISCES optical design, including the similarities and differences of lenslet based IFSs to normal spectrometers, the trade-off between a refractive design and reflective design, as well as the specific function of our pinhole mask on the back surface of the lenslet array to reduce the diffraction from the edge of the lenslets. The optical analysis, alignment plan, and mechanical design of the instrument will be discussed.

Wide-Field InfraRed Survey Telescope Astrophysics ↗

The peculiar behaviour of the 5780 and 5797 DIBs in HD25137

The interstellar environment close to the high latitude molecular cloud Lynds 1569 (L1569, Lynds 1962), also known as MBM 18 (Magnani, Blitz and Mundy, 1985), has been analyzed by Penrase et al. (1990) and Penrase (1993). Their observations of the CH, CH(sup+), and CN molecular features, are consistent with a region having a high molecular and reduced dust content. They also observed the background star HD 24263- located 8 degrees far from the center of L1569 - reporting a CH rich line of sight and the presence of two intervening clouds from a sodium lines spectra. The infrared excess which has been revealed by the IRAS survey at 12 microns might suggest the presence of PAH's molecules, the well know candidate for the Unidentified Infrared Bands and Diffuse Interstellar Bands. This interesting scenario led to the investigation of the behavior of the diffuse interstellar bands toward HD 25137, which is supposed to be a background object for L1569 (Penrase et al., 1990); as well as the field star HD 24263. As part of a wider observational program devoted to study the HLC's special environments, the observations of the diffuse interstellar bands (DIB's) at 5780 and 5797 lambda lambda in the direction of the two above mentioned stars, HD 24263 and HD 25137 are presented here.

Porceddu, Ignazio↗

The high-latitude cloud MBM 7. I. H I and CO observations

The high-latitude cloud (HLC) MBM 7 has been observed in the 21 cm H I line and the 12CO(1-0) and 13CO(1-0) lines with similar spatial resolutions. The data reveal a total mass approximately 30 M solar for MBM 7 and a complex morphology. The cloud consists of a cold dense core of 5 M solar surrounded by atomic and molecular gas with about 25 M solar, which is embedded in hotter and more diffuse H I gas. We derive a total column density N(H I + 2H2) of 1 x 10(21) cm-2 toward the center and 1 x 10(20) cm-3 toward the envelope of MBM 7. The CO line indicates the existence of dense cores [n(H2) > or = 2000 cm-3] of size (FWHM) approximately 0.5 pc. The morphology suggests shock compression from the southwest direction, which can form molecular cores along the direction perpendicular to the H I distribution. The H I cloud extends to the northeast, and the velocity gradient appears to be about 2.8 km s-1 pc-1 in this direction, which indicates a systematic outward motion which will disrupt the cloud in approximately 10(6) yr. The observed large line widths of approximately 2 km s-1 for CO suggest that turbulent motions exist in the cloud, and hydrodynamical turbulence may dominate the line broadening. Considering the energy and pressure of MBM 7, the dense cores appear not to be bound by gravity, and the whole cloud including the dense cores seem to be expanding. The distance to HLCs suggest that they belong to the galactic plane, since the scale height of the cloud is < or approximately equal to 100 pc. Compared to the more familiar dense dark clouds, HLCs may differ only in their small mass and low density, with their proximity reducing the filling factor and enhancing the contrast of the core and envelope structure.

Non-NASA Center↗

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST/AFTA

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) is a prototype lenslet array based integral field spectrometer (IFS) designed for high contrast imaging of extrasolar planets. PISCES will be used to advance the technology readiness of the high contrast IFS baselined on the Wide-Field InfraRed Survey TelescopeAstrophysics Focused Telescope Assets (WFIRSTAFTA) coronagraph instrument. PISCES will be integrated into the high contrast imaging testbed (HCIT) at the Jet Propulsion Laboratory and will work with both the Hybrid Lyot Coronagraph (HLC) and the Shaped Pupil Coronagraph (SPC). We will present the PISCES optical design, including the similarities and differences of lenslet based IFSs to normal spectrometers, the trade-off between a refractive design and reflective design, as well as the compatibility to upgrade from the current 1k x 1k detector array to 4k x 4k detector array. The optical analysis, alignment plan, and mechanical design of the instrument will be discussed.

Integral Field Spectrometer↗