Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Identification of Hip BMD Loss and Fracture Risk Markers Through Population-Based Serum Proteomics: HIP BMD LOSS & FRACTURE RISK MARKERS BY POPULATION-BASED SERUM PROTEOMICS

Accelerated bone loss significantly increases the risk of osteoporosis and fracture. The mechanisms underlying bone loss remain incompletely understood, and there are few available biomarkers. We utilized a novel proteomics approach to identify serum peptides and proteins associated with bone loss in 1967 older men who were randomly chosen from the Osteoporotic Fracture in Men Study (MrOS study) (age ≥ 65 yrs). Men had 2-3 measures of femoral neck BMD over an average follow-up of 4.6 years. Change in BMD was estimated and then categorized into three groups: maintained BMD (n=453), expected loss (n=1185) and accelerated loss (n=237). A liquid chromatography–ion mobility separation-mass spectrometry (LC-IMS-MS) proteomics platform was used to identify and quantify peptides from serum proteins. The whole cohort was randomly divided into discovery (N= 960) and validation (N= 915) sub-cohorts. Linear regression models and a random forest approach were used to discover differentially abundant individual peptides and a proteomic signature that distinguished individuals with accelerated bone loss from those who maintained BMD. Network analyses were performed using the MetaCore knowledgebase. We identified 12 peptides that were associated with BMD loss in both discovery (P< 0.1 FDR) and replication sub-cohorts (P<0.05). Those 12 peptides mapped to the following proteins: ALS, LYVE1, RNAS1, C2, ICOSL, C163A, C7, HEMO, CD14, CERU, CRAC1 and CD59. Meta-analysis of peptidesassociated with bone loss identified 6 additional proteins including GRP78, IGF-2, SHBG, ENPP2, IBP2 and IBP6. We also identified a proteomic signature that was predictive of BMD loss with a discriminative value similar to serum bone marker carboxy-terminal collagen crosslink peptide (CTX). Interestingly, combining the proteomic signature with CTX significantly improved the ability to discriminate men with accelerated loss. In summary, we have identified potential new biomarkers for bone loss that provide a more in depth understanding of its pathophysiology.

59 BASIC BIOLOGICAL SCIENCES↗

Hip Abductor Strength Asymmetry: Relationship to Upper Extremity Injury in Professional Baseball Players

Background: Hip strength is an important factor for control of the lumbo-pelvic-hip complex. Deficits in hip strength may affect throwing performance and contribute to upper extremity injuries. Hypothesis: Deficits in hip abduction isometric strength would be greater in those who sustained an upper extremity injury and hip strength would predict injury incidence. Study Design: Prospective cohort study. Level of Evidence: Level 3. Methods: Minor League baseball players (n = 188, age = 21.5 ± 2.2 years; n = 98 pitchers; n = 90 position players) volunteered. Hip abduction isometric strength was assessed bilaterally with a handheld dynamometer in side-lying position, expressed as torque using leg length (N·m). Hip abduction strength asymmetry was represented by [(trail leg/lead leg) × 100]. Overuse or nontraumatic throwing arm injuries were prospectively tracked. Poisson regression models were used to estimate relative risk ratios associated with hip asymmetry; confounders, including history of prior overuse injury in the past year, were included. Results: Hip abduction asymmetry ranged from 0.05% to 57.5%. During the first 2 months of the season, 18 players (n = 12 pitchers) sustained an upper extremity injury. In pitchers, for every 5% increase in hip abduction asymmetry, there was a 1.24 increased risk of sustaining a shoulder or elbow injury. No relationship between hip abduction strength and injury was observed for position players. Conclusion: Hip abduction asymmetry in pitchers was related to subsequent upper extremity injuries. The observed risk ratio indicates that hip abduction asymmetry may contribute a significant but small increased risk of injury. Clinical Relevance: Hip abduction muscle deficits may affect pitching mechanics and increase arm stress. Addressing hip asymmetry deficits that exceed 5% may be beneficial in reducing upper extremity injury rates in pitchers.

Sport Sciences↗

SU-E-J-230: Effect of Metal Hip Prosthesis On the Accuracy of Electromagnetic Localization and Tracking

Purpose: To quantify the effect of metal hip prosthesis on the ability to track and localize electromagnetic transponders. Methods: Three Calypso transponders were implanted into two prostate phantoms. The geometric center of the transponders were identified on computed tomography and set as the isocenter. With the phantom stationary on the treatment table and the tracking array 14-cm above the isocenter, data was acquired by the Calypso system at 10 Hz to establish the uncertainty in measurements. Transponder positional data was acquired with unilateral hip prostheses of different metallic compositions and then with bilateral hips placed at variable separation from the phantom. Results: Regardless of hip prosthesis composition, the average vector displacement in the presence of a unilateral prosthesis was < 0.5 mm. The greatest contribution to overall vector displacement occurred in the lateral dimension. With bilateral hip prosthesis, the average vector displacement was 0.3 mm. The displacement in the lateral dimension was markedly reduced compared with a unilateral hip, suggesting that there was a countervailing effect with bilateral hip prosthesis. The greatest average vector displacement was 0.6 mm and occurred when bilateral hip prostheses were placed within 4 cm of the detector array. Conclusion: Unilateral and bilateral hip prostheses did not have any meaningful effect on the ability to accurately track electromagnetic transponders implanted in a prostate phantom. At clinically realistic distances between the hip and detection array, the average tracking error is negligible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-612: Photonuclear Activation of Prosthetic Hips in Radiotherapy

Purpose: To measure the neutron induced activation of a prosthetic hip when exposed to an 18 MV radiotherapy linac beam to assess the potential dose to patients. Methods: A prosthetic hip (Thackray, UK) was placed in a water phantom and irradiated (both in-field and out-of-field) with an 18 MV linac beam. Gamma spectroscopy was used to identify the radioisotopes produced. Following the in-field irradiation where the induced activity is higher, high sensitivity lithium fluoride Thermoluminescence Dosimeters (TLD-100H) (Harshaw, USA) were placed on the surface to measure the dose which would be deposited to nearby tissue resulting from the induced radioactivity. Results: The radioisotopes produced in the hip prosthesis have been identified as {sup 5{sup 2}}V, {sup 5{sup 3}}Fe, and {sup 56}Mn which have half-lives of 3.74, 8.51 and minutes respectively. The 378 and 511 keV characteristic peaks of {sup 5{sup 3}}Fe do not appear in the spectra collected from hips irradiated in the out-of-field region. This isotope is produced by photonuclear interactions within the hip itself. {sup 52}V and {sup 56}Mn appear in spectra collected from hips irradiated either within the photon beam or in the nearby out-of-field region, implying that they are produced by incident neutron radiation produced in components of the linear accelerator.The integrated dose which would be deposited in the tissue immediately surrounding the hip after four hours (1.5 half-lives of the longest lived product) was measured as approximately 100 µGy, following a 10,000 MU irradiation of the prosthesis. A highly accurate measurement of the dose is challenging because of the irregular shape of the prosthesis. Conclusion: The cumulative dose measured at the surface of the hip is 0.0001% of the in-field dose, and is therefore negligible compared with the doses the patient receives as a consequence of their treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fuel Fabrication Capability WBS 01.02.01.05 - HIP Bonding Experiments (Final Report)

The goals of this project were to demonstrate reliable, reproducible solid state bonding of aluminum 6061 alloy plates together to encapsulate DU-10 wt% Mo surrogate fuel foils. This was done as part of the CONVERT Fuel Fabrication Capability effort in Process Baseline Development . Bonding was done using Hot Isotatic Pressing (HIP) of evacuated stainless steel cans (a.k.a HIP cans) containing fuel plate components and strongbacks. Gross macroscopic measurements of HIP cans prior to HIP and after HIP were used as part of this demonstration, and were used to determine the accuracy of a finitie element model of the HIP bonding process. The quality of the bonding was measured by controlled miniature bulge testing for Al-Al, Al-Zr, and Zr-DU bonds. A special objective was to determine if the HIP process consistently produces good quality bonding and to determine the best characterization techniques for technology transfer.

36 MATERIALS SCIENCE↗

Hip Fractures: A Practical Approach to Diagnosis and Treatment

Purpose of Review: To summarize relevant anatomy, imaging, and treatment of hip fractures, and to synthesize a treatment-based approach for description and classification of hip fractures. Recent Findings: Hip fractures are predominantly seen in the elderly, where they are increasing in incidence, and can substantially reduce healthy life-years. The osseous and vascular anatomy of the proximal femur can help to understand the clinical implications of various types of hip fracture. Radiographs are the principal imaging modality for assessment of hip fracture, although there is a clear role for CT and MRI for assessment of radiographically occult fractures. There are multiple classifications of hip fractures in the orthopedic literature; however, these are not commonly used in clinical practice due to complexity, poor reported inter-observer agreement, and relatively few methods of surgical fixation. Summary: A simplified anatomic and treatment-based approach to hip fractures can help guide image interpretation and clinical management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relative Importance of Hip and Sacral Pain Among Long-Term Gynecological Cancer Survivors Treated With Pelvic Radiotherapy and Their Relationships to Mean Absorbed Doses

Purpose: To investigate the relative importance of patient-reported hip and sacral pain after pelvic radiotherapy (RT) for gynecological cancer and its relationship to the absorbed doses in these organs. Methods and Materials: We used data from a population-based study that included 650 long-term gynecological cancer survivors treated with pelvic RT in the Gothenburg and Stockholm areas in Sweden with a median follow-up of 6 years (range, 2-15) and 344 population controls. Symptoms were assessed through a study-specific postal questionnaire. We also analyzed the hip and sacral dose-volume histogram data for 358 of the survivors. Results: Of the survivors, one in three reported having or having had hip pain after completing RT. Daily pain when walking was four times as common among the survivors compared to controls. Symptoms increased in frequency with a mean absorbed dose >37.5 Gy. Also, two in five survivors reported pain in the sacrum. Sacral pain also affected their walking ability and tended to increase with a mean absorbed dose >42.5 Gy. Conclusions: Long-term survivors of gynecological cancer treated with pelvic RT experience hip and sacral pain when walking. The mean absorbed dose was significantly related to hip pain and was borderline significantly related to sacral pain. Keeping the total mean absorbed hip dose below 37.5 Gy during treatment might lower the occurrence of long-lasting pain. In relation to the controls, the survivors had a lower occurrence of pain and pain-related symptoms from the hips and sacrum compared with what has previously been reported for the pubic bone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HIGH PRECISION ABUNDANCES OF THE OLD SOLAR TWIN HIP 102152: INSIGHTS ON Li DEPLETION FROM THE OLDEST SUN

We present the first detailed chemical abundance analysis of the old 8.2 Gyr solar twin, HIP 102152. We derive differential abundances of 21 elements relative to the Sun with precisions as high as 0.004 dex ({approx}<1%), using ultra high-resolution (R = 110,000), high S/N UVES spectra obtained on the 8.2 m Very Large Telescope. Our determined metallicity of HIP 102152 is [Fe/H] = -0.013 {+-} 0.004. The atmospheric parameters of the star were determined to be 54 K cooler than the Sun, 0.09 dex lower in surface gravity, and a microturbulence identical to our derived solar value. Elemental abundance ratios examined versus dust condensation temperature reveal a solar abundance pattern for this star, in contrast to most solar twins. The abundance pattern of HIP 102152 appears to be the most similar to solar of any known solar twin. Abundances of the younger, 2.9 Gyr solar twin, 18 Sco, were also determined from UVES spectra to serve as a comparison for HIP 102152. The solar chemical pattern of HIP 102152 makes it a potential candidate to host terrestrial planets, which is reinforced by the lack of giant planets in its terrestrial planet region. The following non-local thermodynamic equilibrium Li abundances were obtained for HIP 102152, 18 Sco, and the Sun: log {epsilon} (Li) = 0.48 {+-} 0.07, 1.62 {+-} 0.02, and 1.07 {+-} 0.02, respectively. The Li abundance of HIP 102152 is the lowest reported to date for a solar twin, and allows us to consider an emerging, tightly constrained Li-age trend for solar twin stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Creep-Fatigue Properties of Additional 316H PM-HIP Materials Fabricated from Different Powder Compositions and Processing Routes

The process of powder metallurgy (PM) hot isostatic pressing (HIP) works by consolidating powdered materials at relatively high temperature and pressure to form near-net-shaped components. Ideally, PM-HIP production methods can reduce component lead time and improve designs for high-temperature reactors and/or microreactors. To introduce PM-HIP into Section III, Division 5 of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, it is necessary to show adequate material properties regarding creep, high-temperature low-cycle fatigue, and creep fatigue. However, prior work has shown that the creep-fatigue cycles to failure for PM-HIP 316H stainless steel are greatly reduced compared to the conventional, wrought product. This work continued creep-fatigue analysis on a 316H stainless steel with lower oxygen and nitrogen contents and at different HIP parameters than previously analyzed. The objective was to better understand what is causing the reduced PM-HIP 316H performance so improvements can be made PM-HIP 316H creep-fatigue lifetimes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Powder Metallurgy HIP Process Study and Mechanical Property Evaluations for IN740H

The effects of hot isostatic pressing (HIP) parameters and powder size distribution (PSD) on the resulting microstructure and properties of powder metallurgy (P/M) IN740H have been investigated. Properties can be substantially tailored through the appropriate management of these parameters. Applying a thermal presoak to the input powder prior to the sintering stage of HIP can significantly increase average grain size and coarse grain fraction, enabling a trade for improved creep resistance at the expense of tensile strength. Here, powder thermal presoak was found to have a larger impact on microstructure and properties than the use of a coarser PSD alone. Additionally, substantial grain growth and grain boundary migration is observed in P/M IN740H at HIP temperatures above 1260°C. Given its inherently finer grain size, P/M HIP IN740H typically outperforms its cast and wrought counterparts in tensile response. Creep life at 700–800°C was inferior to wrought due to PPBs coincident with grain boundaries which served as cavity nucleation sites, leading to lower creep ductility. The ability to adjust the microstructure toward a more balanced creep and tensile behavior allows P/M HIP IN740H to be considered for high-temperature applications in advanced ultra-supercritical steam and supercritical carbon dioxide power cycles.

36 MATERIALS SCIENCE↗

Comparing structure-property evolution for PM-HIP and forged alloy 625 irradiated with neutrons to 1 dpa

The nuclear power industry has growing interest in qualifying powder metallurgy with hot isostatic pressing (PM-HIP) to replace traditional alloy fabrication methods for reactor structural components. But there is little known about the response of PM-HIP alloys to reactor conditions. This study directly compares the response of PM-HIP to forged Ni-base Alloy 625 under neutron irradiation doses ~0.5–1 displacements per atom (dpa) at temperatures ranging ~321–385 °C. Post-irradiation examination involves microstructure characterization, ASTM E8 uniaxial tensile testing, and fractography. Up through 1 dpa, PM-HIP Alloy 625 appears more resistant to irradiation-induced cavity nucleation than its forged counterpart, and consequently experiences significantly less hardening. This observed difference in performance can be explained by the higher initial dislocation density of the forged material, which represents an interstitial-biased sink that leaves a vacancy supersaturation to nucleate cavities. These findings show promise for qualification of PM-HIP Alloy 625 for nuclear applications, although higher dose studies are needed to assess the steady-state irradiated microstructure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pyrolysis and catalytic pyrolysis as a recycling method of waste CDs originating from polycarbonate and HIPS

Highlights: • Thermal and catalytic pyrolysis is a powerful method for recycling of WEEEs. • Liquid products obtained from the pyrolysis of PC or HIPS found in waste CDs are very different. • Mainly phenols are obtained from pyrolysis PC based wastes while aromatics from HIPS. • Use of MgO catalyst increases the amount of phenols from CD recycling compared to ZSM-5. • Use of MgO or ZSM-5 catalysts reduces the amount of styrene recovered from HIPS. - Abstract: Pyrolysis appears to be a promising recycling process since it could convert the disposed polymers to hydrocarbon based fuels or various useful chemicals. In the current study, two model polymers found in WEEEs, namely polycarbonate (PC) and high impact polystyrene (HIPS) and their counterparts found in waste commercial Compact Discs (CDs) were pyrolysed in a bench scale reactor. Both, thermal pyrolysis and pyrolysis in the presence of two catalytic materials (basic MgO and acidic ZSM-5 zeolite) was performed for all four types of polymers. Results have shown significant recovery of the monomers and valuable chemicals (phenols in the case of PC and aromatic hydrocarbons in the case of HIPS), while catalysts seem to decrease the selectivity towards the monomers and enhance the selectivity towards other desirable compounds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Formed HIP Can Processing

The intent of this report is to document a procedure used at LANL for HIP bonding aluminum cladding to U-10Mo fuel foils using a formed HIP can for the Domestic Reactor Conversion program in the NNSA Office of Material, Management and Minimization, and provide some details that may not have been published elsewhere. The HIP process is based on the procedures that have been used to develop the formed HIP can process, including the baseline process developed at Idaho National Laboratory (INL). The HIP bonding cladding process development is summarized in the listed references. Further iterations with Babcock & Wilcox (B&W) to refine the process to meet production and facility requirements is expected.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MRP: Qualification of Powder Metallurgy Hot Isostatic Pressed (PM HIP) Materials for Elevated-Temperature Nuclear Construction

PM HIP is a mature technology that offers many advantages that are attractive to the microreactor industry. The elevated-temperature creep-fatigue properties of the PM HIP 316H SS bar that has been characterized are reduced compared to the wrought material. Work will be carried out in fiscal year 2022 to identify the mechanisms responsible for the reduced creep-fatigue properties. Confirmatory testing of optimized material will be conducted to demonstrate long-term PM HIP properties comparable to the wrought-product form. The lessons learned for PM HIP 316H SS will be applied to the procurement and confirmatory testing of PM HIP Alloy 800H.

316H stainless steel↗

A comparison of plastic and visco-plastic constitutive models for accurate predictions in PM-HIP

Powder metallurgy hot isostatic pressing (PM-HIP) is an advanced manufacturing process that can efficiently produce near net shape parts with high material utilization and uniform microstructures. While the PM-HIP process is used frequently to produce small-scale components, its application to large-scale components is still limited due to inadequate understanding of its complex processes that cause unpredictable post-HIP shape distortions. A computational model can be a cost-effective alternative to exhaustive experimentation required to understand the PM-HIP process fully. Therefore, we present a comparison of plastic and visco-plastic models that are frequently used to model the PM-HIP process. We show that the predictions of powder densification behavior and shape distortions obtained from both the models are similar under most conditions and agree well with experimental observations.

Sarkar, Subrato [ORNL]↗